        36.
        2025.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Most reinforced concrete (RC) school buildings constructed in the 1980s have seismic vulnerabilities due to low transverse reinforcement ratios in columns and beam-column joints. In addition, the building structures designed for only gravity loads have the weak-columnstrong- beam (WCSB) system, resulting in low lateral resistance capacity. This study aims to investigate the lateral resistance capacities of a two-story, full-scale school building specimen through cyclic loading tests. Based on the experimental responses, load-displacement hysteresis behavior and story drift-strain relationship were mainly investigated by comparing the responses to code-defined story drift limits. The test specimen experienced stress concentration at the bottom of the first story columns and shear failure at the beam-column joints with strength degradation and bond failure observed at the life safety level specified in the code-defined drift limits for RC moment frames with seismic details. This indicates that the seismically vulnerable school building test specimen does not meet the minimum performance requirements under a 1,400-year return period earthquake, suggesting that seismic retrofitting is necessary.
        4,000원
        37.
        2025.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, static and dynamic analyses were conducted on three atypical building models to evaluate the displacement response reduction performance based on the outrigger system installation location in a atypical building that incorporated both tapered and twisted shapes. Three 60-story models were developed with a fixed 3-degree taper and twist angles of 1, 2, and 3 degrees per story. Outrigger systems were installed at 10-story intervals and additionally between the 20th and 40th floor at 1-story intervals. The results indicated that, although there were variations depending on the seismic loads, the displacement response reduction performance was generally most effective when the outriggers were installed in the upper stories (41st to 60th floors) of the analytical models.
        4,000원
        38.
        2025.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper aims to quantify the retrofit effect of the Bolt Prefabricated Concrete-Filled Tube reinforcement method on non-seismic school reinforced concrete building through static cyclic loading experiments. To achieve the objective, two-story specimens including a non-retrofitted frame(NRF) and a Bolt Prefabricated Concrete-Filled Tube Reinforcement Frame(BCRF) were tested under static cyclic loading, and the lateral resistant capacities were compared in terms of maximum strength, initial stiffness, effective stiffness, and total energy dissipation. In addition, the load-displacement curves were compared to the story drift limit specified in Seismic Performance Evaluation and Retrofit Manual for School Facilities to investigate if the retrofitted frame was satisfied in target performance(life safety). Experimental results showed that BCRF successfully met the target performance, with a 200% increase in maximum strength and a 300% increase in energy dissipation capacity. Additionally, both initial stiffness and effective stiffness improved by more than 30% compared to NRF. Furthermore, BCRF exhibited an effect that delayed the occurrence of bond failure.
        4,000원
        40.
        2025.03 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        This study was conducted through experiments by producing an image output evacuation guide light linked with a smoke detector. To summarize the results, first, the biggest recognition distance of the door at 30% smoke concentration was found to be the image output evacuation guide light. This is because of visual impairment and fear caused by indoor smoke, and in the process of finding the light of the emergency exit, accurate recognition of the evacuation behavior was searched even at the farthest distance, and it is judged that the time required for evacuation was short. Second, the biggest recognition distance of the door at 70% smoke concentration was the image output evacuation guide light, which showed the longest recognition distance. It is judged that even in smoke with many evacuees, the door is accurately recognized while seeing the light of the image output evacuation guide light and exits safely. Third, when the smoke concentration was 100%, the smoke rose and the evacuation guide light at the top of the door was not identified as thick smoke, and the image output evacuation guide light was displayed on the bottom of the passage, indicating that the evacuee accurately recognized the door and escaped safely to the outside even from a long distance.