검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 1,791

        281.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A behavior of FRP(Fiber Reinforced Polymer) panel in a steel frame structure was evaluated through the finite element analysis in this study. In order to numerical analysis, a experimental test results was used to develop a three dimensional finite element model of steel frame specimen. Numerical results of the steel frame specimen was well predicted the experimental behavior of steel frame specimen. Based on the developed three dimensional finite element model of steel frame specimen, the behavior of FRP panel in the steel frame specimen was evaluated. From the numerical analysis results, strength of the steel frame specimen with FRP panel was governed by FRP panel. Also, diagonal compression behavior governed the FRP panel in the steel frame specimen in the numerical analysis results.
        4,000원
        282.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, a study on noise reduction characteristics of the precast floating track system, being developed as measures to mitigate noise and vibration of existing as well as constructing elevated railroad stations, is presented using numerical analysis. One of the most prominent sound analysis program, Virtual Lab., is utilized in investigating noise reduction performance of the precast floating track system, and structural velocity data, obtained from vibration analysis on a model-updated elevated railroad station considering vehicle-track-structure interaction, are used for the input of the sound analysis. The sound analysis is performed using the finite element method, and noise reduction performance before and after installing the precast floating track system is compared at three enclosed areas in the Daecheon Station, selected as a representative of elevated railroad stations in this nation. From the comparison result, it is seen that the precast floating track system can decrease noise by average of 5dB∼8dB when the Saemaeul train passing through the station and 10dB∼15dB when the KTX train passing through. Also, the noise reduction characteristics is different depending on the type of train and the distance from the track.
        4,000원
        283.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        When reinforcing an existing reinforced concrete beam-column building with a precast concrete panel, special connection between the PC member and the RC member is required to solve the time dependent deformation of the RC member and to receive the large shear forces. The aim of this study is to obtain the shear strength of upper connection between the existing RC beam-column and infilled PC wall panels in experimentally and theoretically. Thus, the static shear loading tests were conducted on the 6 specimens with the plate connection. Shear failure was resulted from the weakest portion of interior PC panel, exterior RC, and the connection, when the PC portion which located at the center of specimen was pulled upward from the bottom. T he experimental result was compared with analytical result from ACI 318M-14 Chapter 17 for the shear strength of post-installed anchor and PCI Handbook 7th edition 6.8 Structural Steel Corbel (PCI Design Handbook 7th edition, 2010) for the strength of cast-in H-beam. The analytical and experimental results show final failure at the same location. The failure loading of experiment showed larger than average 6% to that of the analysis.
        4,500원
        286.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In order to modeling seismic isolation system such as lead-rubber bearing (LRB), bilinear model is widely used by many researchers. In general, an actual force-displacement relationship for LRB has a smooth hysteretic shape. So, Bouc-Wen model with smooth hysteretic shape represents more accurately actual hysteretic shape than bilinear model. In this study, seismic responses for seismically isolated nuclear power plant (NPP) with LRB modelled by Bouc-Wen and bilinear models are compared with those of NPP without seismic isolation system. To evaluate effect of earthquake characteristics for seismic responses of NPP isolated by LRB, 5 different site class earthquakes distinguished by Geomatrix 3rd Letter Site Classification and artificially generated earthquakes corresponding to standard design spectrum by Reg. Guide 1.60 are used as input earthquakes. From the seismic response results of seismically isolated NPP, it can be observed that maximum displacements of seismic isolation modelled by Bouc-Wen model are larger than those by bilinear model. Seismic responses of NPP with LRB is significantly reduced than those without LRB. This reduction effect for seismic responses of NPP subjected to Site A (rock) earthquakes is larger than that to Site E (soft soil) earthquakes.
        4,000원
        287.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구의 목적은 시스템 식별기술과 칼만필터링을 기반으로 계측된 가속도응답을 이용하여 구조물에 작용하는 모달하중을 역으로 추정하는 기법을 제시하는데 있다. 하중추정 과정에서 가속도응답은 모드응답으로 분해되며 각 모드응답에 대한 모달하중을 역으로 추정한다. 역해석과정에서 발생하는 ill-posed문제를 피하기 위하여 가상진동기에 의해 구조물의 고유진동수와 감쇠비를 보다 정밀하게 구하기 위한 시스템 식별법을 사용하였다. 본 연구에서 제안된 기법의 적용성을 위하여 40층의 철골구조물에 태풍이 작용 했을 때 계측된 가속도를 사용하였다. 적용결과에 의하면 본 연구에서 제안된 하중추정법에 의하여 모달하중 추정이 가능함을 알 수 있었다.
        4,000원
        288.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        OBJECTIVES : Fixed roadside objects are a threat to drivers when their vehicles deviate from the road. Therefore, such roadside objects need to be suitably dealt with to decrease accidents. This study determines the factors affecting the severity of accidents because of fixed roadside objects. METHODS : This study analyzed the crash severity impact of fixed roadside objects by using ordered probit regression as the analysis methodology. In this research, data from 896 traffic accidents reported in the last three years were used. These accidents consisted of sole-car accidents, fixed roadside object accidents, and lane-departure accidents on the national highway of Korea. The accident severity was classified as light injury, severe injury, and death. The factors relating to the road and the driver were collected as independent variables. RESULTS: The result of the analysis showed that the variables of the crash severity impact are the collision location (left side), gender of the driver (female), alcohol use, collision facility (roadside trees, traffic signals, telephone poles), and type of road (rural segments). Additionally, the collision location (left side), gender of the driver (female), alcohol use, collision facility (street trees, traffic signals, telephone poles), and type of road (rural segments), in order of influence, were found to be the factors affecting the crash severity in accidents due to fixed roadside objects. CONCLUSIONS: An alternative solution is urgently required to reduce the crash severity in accidents due to fixed roadside objects. Such a solution can consider the appropriate places to install breakaway devices and energy-absorbing systems.
        4,000원
        290.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, refined finite element (FE) analyses intended to evaluate the capacity of the existing water purification plant structures against seismic force are conducted with an aim to predict possibility generating tension crack and compression crushing. The FE models for three types of main plant structures were constructed to take ground condition, boundary condition, and water interaction into consideration for advanced simulation. The nonlinear dynamic analyses were performed by using ground motion data which have been used for seismic design. Both compression crushing and tention crack, which are distributed over concrete plant structures during peak ground acceleration (PGA), are investigated by analyzing failure possibility controlled with the strain limits. After observing FE analysis results, it is possible to predict tenstion cracking which can be found at some parts of the main structure.
        4,000원
        291.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Fiber-reinforced polymer (FRP) bars have advantages as a construction material, including corrosion resistance, lightweight and high tensile strength. However, FRP rebars have shortcomings, such as low elastic modulus comparing to the steel rebar. With these reasons, FRP bars have not been widely used to reinforced-concrete (RC) structures. To overcome these shortcomings, the steel-hybrid GFRP rebars were developed by the authors at Korea Institute of Civil Engineering and Building Technology (KICT). Mechanical properties of the developed steel-hybrid GFRP rebars were experimentally evaluated through this study. Both tensile and bonding tests were conducted and the mechanical performance was investigated as well as corrosion resistance. As a result of all tests, elastic modulus, tensile strength and boding strength of the steel-hybrid GFRP rebars were all improved in comparison with fully GFRP rebars.
        4,000원
        292.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Lifting plan in the large spacial structure is an important factor influencing the efficiency and economy of the construction process. The purpose of this study was deriving the requirements for lifting techniques as the basic research in the double spoke wheel roof structure construction. In the lift up erection method, management plan of the interference error in the column and outer-ring was needed that occur during lifting roof structure. In the bent erection method, material usage reduction plan was required by the structural design of the temporary bent. In the hybrid erection method, lifting plan was needed that minimizes weather condition and crane usage. All lifting techniques were required Value Engineering model for reduction of cost and construction period.
        4,000원
        293.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A retractable-roof spatial structure is frequently used for a stadium and sports hall. A retractable-roof spatial structure allows natural lighting, ventilation, optimal conditions for grass growth with opened roof. It can also protects users against various weather conditions and give optimal circumstances for different activities. Dynamic characteristics of a retractable-roof spatial structure is changed based on opened or closed roof condition. A tuned mass damper (TMD) is widely used to reduce seismic responses of a structure. When a TMD is properly tuned, its control performance is excellent. Opened or closed roof condition causes dynamic characteristics variation of a retractable-roof spatial structure resulting in off-tuning. This dynamic characteristics variation was investigated. Control performance of a passive TMD and a smart TMD were evaluated under off-tuning condition.
        4,000원
        294.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The seismic isolation system reduces the seismic vibration that is transmitted from foundation to upper structure. This seismic isolation system can be classified into base isolation and mid-story isolation by the installation location. In this study, the seismic behavior of dome structure with mid-story isolation is analyzed to verify the effect of seismic isolation. Mid-story isolation is more effective than base isolation to reduce the seismic responses of roof structure. Also, this isolation would be excellent in structural characteristics and construction.
        4,000원
        296.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        After an earthquake occurred in the Gyeongju, 2016, many low-story buildings have been questioned in terms of the seismic performance since mostly they have been exempted from the seismic design requirement since 1988. In this study, a 3-story moment resisting frame (MRF) building was analyzed and evaluated the seismic performance. Due to the insufficient seismic performance required for the seismic performance levels, three different seismic retrofit schemes were proposed and their seismic performances were re-evaluated. While steel brace and open shear wall retrofit systems mainly focused on the strength retrofit, the VES damper retrofit system is mainly to enhance the energy dissipation capacity of the system and resultes in the increased ductility. The original building and 3 retrofitted buildings were evaluated using the nonlinear static and nonlinear dynamic analyses and suggestions were proposed. Through the analysis of nonlinear time history and push-over using MIDAS/Gen program, damages of the building in terms of top story and average story drift and effect of reinforcement were analyzed.
        4,000원
        297.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, effectiveness of seismic retrofitting methods using passive damping devices was investigated through numerical analyses of short-period structures under earthquakes which have short-duration and high-frequency impulse characteristics similar to Geyongju earthquakes. Displacement spectra of elastic systems and ductility demand of inelastic systems were evaluated by increasing viscous or friction damping. The damping devices could reduce responses of the structures with shorter structural period than 0.2s. The earthquakes similar to impulse load did not induce the responses of the structures with longer period than 0.4s, and the effects of the damping devices which generates damping forces proportional to structural responses became insignificant.
        4,000원
        298.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, time and frequency domain characteristics of Gyeong-ju earthquakes were investigated, and nonlinear time history analyses were conducted for bi-linear hysteretic structures excited by short-duration ground accelerations. Previous studies showed that larger inelastic displacements than the peak displacement of the corresponding elastic system were observed especially for the structures with structural period shorter than 0.3s, and the similar results could be obtained when long-duration ground accelerations were used as excitation loads. For the short-duration earthquakes, however, the inelastic displacements were not so large and almost identical to the peak elastic displacements.
        4,000원
        299.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The Gyeong-Ju earthquake in the magnitude of 5.8 on the Richter scaleoccurred in September 12, 2016. Because there are many nuclear power plants (NPP) near the epicenter of the Gyeong-Ju earthquake, the seismic stability of nuclear power plants is becoming a social problem. In order to evaluate the safety of seismically isolated NPP, the seismic response of a NPP subjected to the Gyeong-Ju earthquake was compared with those of 30 sets of artificial earthquakes corresponding to the nuclear standard design spectrum (NSDS). A 2-node model and a simple beam-stick model were used for the seismic analysis of seismically isolated NPP structures. Using 2-node model, the effect of internal temperature rise, decrease of shear stiffness, increase of lateral displacement and decrease of vertical stiffness according to nonlinear behavior of lead-rubber bearing (LRB) were evaluated. The displacement response, the acceleration response, and the shear force response of the seismically isolated nuclear containment structure were evaluated using the simple beam-stick model. It can be observed that the seismic responses of the isolated nuclear structure subjected to Gyeong-Ju earthquake is significantly less than those to the artificial earthquakes corresponding to NSDS.
        4,000원