        361.
        2012.11 서비스 종료(열람 제한)
        In this study, experimental research was carried out to study the structural performance of slab-column joints designed by the application of reducing of joint regions damage using steel fiber reinforced concrete. Test results showed that specimens(RCFPS series) were increased the maximum load-carrying capacity by 1.12~1.23 times and showed stable hysteresis behavior in comparison with the standard specimen(SRCFP).
        362.
        2012.11 서비스 종료(열람 제한)
        Structural Performance Test of FRP-Concrete Composite Deck according to Existence of Shear Connecting Plates by Long Term Exposure was performed to study the Performance Evaluation. As the result, it was verified that this deck has sufficient serviceability and structural performance as a bridge deck.
        363.
        2012.11 서비스 종료(열람 제한)
        To check the serviceability of K-UHPC structures, we need the guideline for the allowed crack width in various environment. To setup the guideline, direct tensile test of reinforced K-UHPC tensile members was implemented. The test results show very small crack width, and the allowed values for the ordinary concrete can be used for K-UHPC structures.
        364.
        2012.09 KCI 등재 서비스 종료(열람 제한)
        이 논문에서는 대표적 수치해석에의 균열처리 방법으로 손상모델 기반의 분산균열모델을 체택하여 구조내력을 산정하였다. 또한 전력구 구조물의 실구조 모델링을 위해 3차원 해석방법을 택하였으며 3차원 콘크리트 구성모델로는 현재 3차원 모델중 콘크리트의 다축압축, 인장균열을 효과적으로 모사하는 미소면 모델(Microplane model)을 재료모델로 사용하여 비선형 유한요소해석을 수행하였다. SFRC의 인장연화곡선을 얻기 위해 역해석법을 사용하였으며, 역해석으로 구한 인장연화곡선이 실험결과와 아주 잘 일치함을 보였다. 하중-균열폭 관계를 입력값으로 사용한 역해석 결과와 하중-CMOD 관계를 사용한 역해석 결과는 서로 잘 일치하는 경향을 나타냈다. 이 논문에서는 실험으로부터 측정된 균열폭 데이터와 수치해석시의 손상지수와의 관계를 도출하여으며, 이와 같은 결과는 향후 균열탐사를 통한 구조물의 잔존 구조내력 산정에 적용할 수 있으리라 판단된다.
        365.
        2012.09 KCI 등재 서비스 종료(열람 제한)
        이 연구에서는 순환굵은골재를 사용한 철근콘크리트 보의 휨거동을 평가한다. 이를 위하여 골재의 종류와 흡수율이 서로 다른 3개의 실험체를 제작하였다. 모든 실험체는 4점 가력을 받도록 계획하였으며, 전단의 영향이 크도록 전단경간비를 2.5로 계획하였다. 실험체의 모멘트-곡률 관계를 예측하기 위하여 인장증강효과를 고려한 비선형 휨해석을 수행하였으며, 실험체의 전체 거동을 평가하기 위하여 전단의 영향을 고려할 수 있는 비선형 유한요소해석을 수행하였다. 실험결과, 흡수율 6%의 순환굵은골재를 사용한 실험체의 휨강도와 균열특성은 천연골재를 사용한 실험체와 서로 유사함을 확인할 수 있었다. 그리고 실험결과와 해석결과를 비교한 결과, 기존 해석방법을 이용하여 순환굵은골재를 사용한 철근콘크리트 보의 거동을 타당하게 예측할 수 있음을 확인할 수 있었다.
        366.
        2012.05 서비스 종료(열람 제한)
        In this study, three kinds of nondestructive evaluation (NDE) techniques for the effective maintenance of underwater concrete structures are investigated: schmidt hammer-based NDE, indirect ultrasonic waves-base NDE and impact echo method using noncontact air-coupled sensing system. Currently, lots of limitations to implement these techniques to real-world structures are being considered.
        367.
        2012.05 서비스 종료(열람 제한)
        This paper is to investigate the effect of heat curing method on strength development of concrete subjected to -10℃ by preparing mock up specimen, which had slab, wall and column. As expected, the application of heat curing methods had larger strength than non heat curing specimen because of higher maturity. And within 7 days of heat curing, minimum strength to protect from early frost damage was achieved.
        368.
        2012.05 서비스 종료(열람 제한)
        In this study, experimental research was carried out to improve the structural performance of reinforced concrete beam-column joint using high performance FRP materials in existing reinforced concrete building. Test result shows that retrofitting specimen(LBCJ-CRU, CRS, CRUS) designed by the improvement of seismic performance of reinforced concrete beam-column joints load-carrying capacities were increased 1.30~1.54 times in comparison with the standard specimen.
        369.
        2012.05 서비스 종료(열람 제한)
        It has been changed from conservative method that require partial destruction of concrete structure to new method that is nondestructive method or require just tissue of concrete structure for the stability evalution of concrete structures. The estimation technique that is the purpose of this project are very forehanded at the time of state-of-the-art equipments that give diagnosis work efficiency and accuracy is presented in this study. This study included that the discovering a equipment for collection of concrete powder, the suggestion of thermal analysis at the estimation of neutralization of concrete, the estimation technique for suggestion of appropriate repair time, the estimation methods that are to presume carbonation processing amount and to assume damage degree caused by freezing and thawing action.
        370.
        2012.05 서비스 종료(열람 제한)
        In this paper, the applicability of structural health monitoring (SHM) system is evaluated on a full-scale concrete cable-stayed bridge, Hwamyung Bridge in Korea. Firstly, Imote2-platformed wireless sensor node for structural health monitoring is designed to monitor the cable forces by the vibration-impedance-based SHM. Secondly, the experimental setup is presented by filed verification test on Hwamyung Bridge. Finally, the long-term monitoring performance of the wireless sensor system is examined under various weather conditions. Also, the accuracy of cable force monitoring by the wireless sensor system is evaluated for the target bridge.
        371.
        2012.04 KCI 등재 서비스 종료(열람 제한)
        프리캐스트 콘크리트 모듈 단위로 시공되는 플로팅 구조물의 거동은 콘크리트 모듈 접합부의 거동과 밀접한 연관성을 갖는다. 극한하중조건에서의 플로팅 구조물의 구조적 거동을 정확히 예측하기 위해서 모듈 접합부의 구조거동 실험연구를 수행하였다. 모듈 접합부 전단키의 전단거동, 전단강도 및 균열 패턴을 파악하였다. 실험결과는 전단키의 경사각도가 증가함에 따라 전단강도가 증가하는 것을 나타낸다. 또한, 구속응력이 증가함에 따라 전단키의 전단강도가 증가한다. 실험결과와 AASHTO 제안식에 의한 예측값을 비교하였으며, AASHTO 제안식은 실험값을 과소평가하고 있다.
        372.
        2012.02 서비스 종료(열람 제한)
        Image created by stack imaging spectral amplitudes based on the impact-echo (SIBIE) method is largely one-dimensional because a single frequency domain spectrum for wave reflected below a single point of impact is used to create the image. The method has limitations for representing defects in a cross section of a concrete structural element using two-dimensional coordinates. This study focused on defect detection and visualization in a concrete structural element using multiple impacts and accumulated SIBIE. An impactor was used to induce energy at multiple points at positioned at prescribed intervals along the structural element. A modified SIBIE method was applied to the collected data of each point and the modified SIBIE images were accumulated to generate one image (an accumulated SIBIE image). As a result, the defect positions could be represented in the cross section of the structural element using a two-dimensional coordinate system.
        373.
        2012.01 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 디지털 이미지 분석기술을 이용하여 콘크리트 구조물의 대표적인 열화인자인 콘크리트의 균열을 검지할 수 있는 기술을 개발하기 위해 형태수리학에 근거한 모폴로지 기법이 도입된 이미지 분석기법을 적용한 균열검출 시스템을 개발하였다. 개발된 시스템에는 분석결과의 효율적인 관리를 고려하여 촬영된 다수의 이미지를 하나의 전체 이미지로 재구성하는 이미지 조합기술이 추가로 적용되었다. 그리고 개발된 시스템의 적용성 및 신뢰도 검증은 균열이 발생된 콘크리트 암거를 이용한 현장검증 실험을 통해 이루어졌으며, 실험에 사용된 촬영장비로는 40m까지 0.2mm의 균열을 검지할 수 있는 성능을 확인하였다. 이미지 분석을 통해 산정된 균열폭의 경우 실측 균열폭과의 차이가 최대 0.08mm로 나타나 일정 수준 이상의 정확도를 구명하였고, 이미지 조합의 경우 추상 패턴 이미지 면에 대한 분할 촬영 이미지를 조합한 결과 실제 전체촬영 원본 이미지와 육안으로 차이를 확인할 수 없을 정도로 우수한 조합결과를 도출하였다.
        374.
        2011.09 KCI 등재 서비스 종료(열람 제한)
        최근 건설되는 교량은 철근 콘크리트 대신에 주로 프리스트레스트 콘크리트 교량이 주종을 이루고 있다. 프리스트레스 콘크리트 (PSC)는 철근 콘크리트 (RC)가 지니는 균열발생 문제, 철근의 부식, 누수 등 내구성에 미치는 약점을 보완할 수 있다. 또한 프리스트레싱으로 인한 인장영역의 보완으로 인하여 구조물의 크기를 줄일 수 있다. 하지만 이러한 구조용 주재료인 고강도 콘크리트의 경우는 밀도가 강도에 비하여 상대적으로 크기 때문에 상대적으로 자중을 증대시키는 문제가 있다. 따라서 자중을 감소시킬 수 있는 경량골재를 활용한 중공형 PPC 거더 (Hollowed Prefabricated Prestressed Concrete girder systems using Light Aggregate, 이하 HPPCLA)는 이러한 문제점을 해결할 수 있는 대안이 될 수 있다. 본 연구에서는 HPPCLA 거더의 성능시험 뿐 만 아니라 수치해석을 수행하였으며, 그 결과 HPPCLA 거더는 전형적인 휨파괴 형상을 나타내었다. 수치해석에서 예상한 바와 같이 PPC 거더의 사용하중인 110 kN에서는 완전한 탄성거동으로 구조물의 사용성에는 무리가 없을 것으로 판단된다.
        375.
        2011.05 KCI 등재 서비스 종료(열람 제한)
        본 논문에서는 비접촉식 충격-반향 기법을 이용한 콘크리트 구조물의 손상 탐지에 있어서 비용 효율성을 높이기 위한 다이나믹 마이크로폰의 적용 가능성에 대하여 알아보았다. 박리 손상이 인공적으로 모사된 콘크리트 슬래브 실험체에 대하여 비접촉 충격-반향 실험을 다이나믹 마이크로폰을 이용하여 수행하였으며 저비용 센서 시스템의 손상 탐지 성능을 분석하였다. 실험 결과 다이나믹 마이크로폰으로 의미있는 신호의 측정이 가능하며, 또한 콘크리트의 박리 손상도 고성능 음압 센서만큼 명확하게 검출 가능하다는 것을 알 수 있었다.
        376.
        2011.05 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 철근 콘크리트 터널 구조물을 해상 대기중 비래염분이 침투하는 터널 내벽과 해수에 항시 접촉하는 터널 외벽으로 구분하여, 몬테카를로 시뮬레이션에 의해 철근 부식 개시 확률을 예측하였다. 염해관련 변수의 변동성을 평가하기 위하여 염소이온 확산계수, 표면 염소이온농도, 피복두께, 임계 염소이온농도를 실제 실험 및 문헌 조사를 통해 확률특성을 구하였다. 그 결과 염소이온 확산계수의 평균치는 3.77×10^(-12) ㎡/s 이었으며, 대상 부재인 터널 내벽과 외벽의 피복두께는 각각 45.5mm, 94.7mm으로 조사되었고, 임계 염소이온농도의 평균은 결합재 단위중량당 0.69%이었다. 각 변수의 확률적 특성에 근거하여 노출기간에 따른 철근위치에서의 염소이온 농도 분포를 구하였다. 재령이 증가할수록 침투 염소이온 농도의 평균값은 증가하며, 변동계수는 감소하게 됨을 알 수 있었다. 또한 확률론적 염해 해석기법을 적용하여 콘크리트 터널 내벽과 외벽에 대해 내구수명 및 부식개시 확률을 평가하였다. 염소이온 침투의 시간의존성을 고려하지 않은 경우 터널 내벽과 외벽에 대해 각각 8년, 12년의 내구수명이 도출되었으나, 시간의존적 모델에서는 178년, 283년의 내구수명이 계산되어 구조물의 설계내구수명(100년)을 만족하고 있음을 보였다. 또한, 시간의존성을 고려하지 않은 경우 100년에서의 부식 개시 확률은 터널 내벽과 외벽에 대해 각각 59.5, 95.5%였으며, 시간의존성 모델에서는 2.9, 0.2%로 계산되었다. 따라서 구조물의 과다설계를 방지하고 보다 합리적인 내구수명 설계 및 평가를 위해서는 염소이온 확산의 시간의존성을 고려하여야 한다. 마지막으로 본 연구에서 문헌 조사를 통해 구한 부식 발생 임계 농도를 현재 콘크리트 관련 기준에 제시한 값과 비교하여 분석하였다.
        377.
        2011.02 서비스 종료(열람 제한)
        필로티 구조는 인구 및 산업시설의 도시 집중화로 인해 부족한 택지 및 용지의 해결을 위하여 도입된 이래, 국내 기존 저층 다세대 주택 및 근린생활시설 등의 주차공간 및 기준층 공간 확보를 위하여 주로 채택되고 있으나, 이들 필로티 구조는 지진발생시 필로티 층의 내진성능 부족으로 층 전체가 붕괴될 가능성이 높다. 하지만 이에 대한 파괴모드 및 손상 메커니즘에 관한 연구가 부족한 실정으로, 본 연구에서는 필로티 구조의 손상 메커니즘을 파악하기 위하여 저층 철근콘크리트 필로티 건축물을 모사한 실험체를 제작하여 실제 지진파를 이용한 진동대 실험을 수행하였다. 실험체는 기존 저층 다세대 주택 및 근린생활시설의 도면을 수집·분석하여 실제 대상 건축물의 구조적 특성 및 동적 응답특성을 가장 잘 모사할 수 있도록 기둥과 코어간 전단력비, 강성비 등을 고려하여 계획하였으며, 총 2개 층으로 1층은 4개의 필로티 기둥과 1개의 계단실 코어벽으로, 2층은 1층에서 연장된 코어벽과 전단벽으로 구성되었다. 실험에 사용한 지진파는 El-Centro NS파(1940년, PGA=350gal)로, 최대가속도를 기준으로 국내 내진설계기준의 지진하중 기준을 고려하여 Scale을 증가시키며 동적가력 하였다. 실험결과, 필로티층에 손상이 집중되었으며 상층부는 강체로 거동하면서 거의 손상이 발생하지 않았다. 필로티 층에서는 가진방향 코어벽체에 최초로 전단균열이 발생한 후 점차 균열이 확대되어 최종 전단파괴 된 반면, 기둥은 상·하부에 미소 휨균열만이 발생하였다. 이는 코어벽체가 기둥보다 전단내력은 더 크지만 단면 형상에 따른 수평강성 또한 커지게 되어 코어벽체와 기둥이 병렬적으로 연결된 본 실험체 경우, 강성이 큰 코어벽체에 하중이 집중되었기 때문이다. 따라서 필로티 구조를 가지는 건축물이 지진하중을 받을 시, 필로티 층에 손상이 집중되며 필로티 층에서는 강성이 큰 코어벽체의 전단파괴가 선행되고 이후 내력을 상실하면 상대적으로 기둥의 내력이 부족하여 전제 수직·수평하중을 부담하지 못하고 층붕괴에 이르는 손상 메카니즘을 가지는 것으로 판단된다.
        378.
        2011.01 KCI 등재 서비스 종료(열람 제한)
        해양환경 하에서 염화물의 침투를 억제하여 부식 위험을 최소화함으로써 콘크리트 구조물의 공용기간을 연장할 수 있다. 효과적으로 구조물을 관리하기 위해 적절하게 유지관리하는 것이 필요하다. 본 연구에서는 효과적인 유지관리 전략을 세우기 위한 보수된 구조물의 유지관리비용 평가와 연계하여 구조물의 사용수명을 정량적으로 평가하는 방법을 제안하였다. Fick의 제2법칙으로부터Crank-Nicolson법에 기초한 유한 차분법을 제안하여 보수되지 않은 콘크리트 구조물과 보수된 콘크리트 구조물의 염화물 이온 분포를 예측하였다. 이를 이용하여 보수에 의해 연장 가능한 사용수명과 목표한 공용기간 동안에 필요한 보수 횟수를 평가하였다. 게다가보수 횟수와 콘크리트 교체 비용을 고려하여 총 유지관리 비용을 산출하였다. 마지막으로 제안된 방법의 적용성 검토를 위해 수치해석예제를 제시하였다.
        379.
        2011.01 KCI 등재 서비스 종료(열람 제한)
        이 연구에서는 나선철근으로 횡구속된 순환골재 콘크리트의 구조적 거동을 평가하였다. 주요 실험변수는 골재의 종류와 나선철근의 철근비로 계획하였다. 총 18체의 실험체를 제작하였으며, 실험체의 직경과 높이는 각각 150mm와 300mm이었다. 실험체는 사용된 굵은 골재의 종류에 따라 2가지로 구분할 수 있으며, 나선철근의 철근비는 0%에서 1.75%까지 변화하도록 계획하였다. 실험체의 축방향 및 횡방향 변형을 측정하기 위하여, 6개의 LVDT를 실험체에 부착하였다. 또한 나선철근의 변형률을 측정하기 위하여 스트레인 게이지를 120도 간격으로 나선철근에 부착하였다. 실험결과로부터, 나선철근으로 횡구속된 순환 골재콘크리트의 구조 성능은 나선철근의 철근비와 관계없이 천연골재 콘크리트와 서로 유사함을 확인하였다.
        380.
        2010.11 KCI 등재 서비스 종료(열람 제한)
        본 연구는 표준실험체인 전단보강근이 없는 철근콘크리트 보(SSS)와 전단보강근이 있는 철근콘크리트 보(BSS), 성능개선실험체로는 전단보강근이 없는 철근콘크리트 보에 고로슬래그미분말을 혼입한 고인성섬유 복합모르타르를 타설한 실험체(SHF시리즈, SHFSC시리즈)로 총 11개의 실험체를 축소 제작하여 실험을 수행하였다. 실험을 통하여 얻어진 결과를 비교․분석하여 하중-변위, 파괴형태, 최대내력, 전단응력 등을 규명함으로써 구조성능의 개선정도를 평가하였다. 고로슬래그미분말을 혼입한 고인성섬유 복합모르타르를 이용한 철근콘크리트 보 실험체(SHF시리즈, SHFSC시리즈)의 경우 전단보강근이 없는 표준실험체(SSS)보다 전단응력은 각각 26%, 28%, 연성능력은 각각 5.27, 5.75배 증가하는 결과를 나타내었다. 또한, 충분한 연성적인 거동과 안정적인 휨인장 파괴를 나타내었다.