검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 298

        121.
        2014.04 구독 인증기관·개인회원 무료
        The floating PV generation structure installed on the surface of water has been recently issued as a representative items for the low carbon and green growth campaign. Moreover, the studies and developments for the structure and construction improvements of floating PV generation structure have been in progress. For example, in the previous research, the floating PV generation structure consisted of pultruded FRP and SMC FRP members is suggested. In this study, we conduct the analytical and experimental studies for estimating the structural characteristics of SMC FRP vertical members. From the analytical and experimental results, it is found that SMC FRP vertical members used for floating PV generation structure have sufficient structural safety and stability.
        122.
        2013.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Pile foundations constructed by the fiber reinforced polymer plastic piles have been used in coastal and oceanic regions in many countries. Generally, fiber reinforced polymer plastic piles are consisted of filament winding FRP which is used to wrap the outside of concrete pile to increase the axial load carrying capacity or pultruded FRP which is located in the core concrete to resist the bending moment arising due to eccentric loading. In this paper, the analytical procedures of hybrid concrete filled FRP tube flexural members are suggested based on the CFT design method. Moreover, the analytical results are compared with the experimental results to obtained by the previous researches. The results of comparison analyses are performed to estimate the accuracy of the analytical procedure for hybrid FRP-concrete composite compression test, members under eccentrical loading.
        4,000원
        123.
        2013.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        철근 및 FRP Bar를 보강재로 사용한 콘크리트 보의 전단 거동을 실험적으로 평가하였다. 실험 변수는 특성이 다른 보강근을 휨 및 전단 보강한 것과 전단보강근비이다. 콘크리트 보의 전단강도 산정에 일반적으로 널리 이용되는 수정트러스 이론의 타당성을 실험 결과의 분석을 통하여 평가하였다. CFRP 및 GFRP를 휨 및 전단 보강한 콘크리트 보에 그대로 적용하는 것은 적절하지 않음을 알 수 있었다. 실험결과는 FRP Bar를 보강근으로 사용한 콘크리트 보의 전단 문제에 수정트러스 이론을 그대로 적용하는 것은 타당하지 않다는 것을 알 수 있었다.
        4,000원
        125.
        2013.03 구독 인증기관 무료, 개인회원 유료
        철근 콘크리트 구조체는 시간의 경과에 따라 시공 중의 설계 변경 및 시공 불량, 구조물의 완공 후의 용도 변경에 따른 하중 증가, 구조물 지역의 환경변화, 시간의 경과에 따른 재료 특성의 변화 등 구조적, 환경적, 재료적 요인에 의해 내구성에 영향을 받게 된다. 따라서 내구성 및 내력 등의 구조적 성능이 저하된 구조체의 안전성을 확보하고 내구연한을 늘리기 위한 적절한 진단과 보수⋅보강이 필요하다. 다양한 구조물의 보강공법 중, 최근에는 재료의 자중, 구조체 사용 면적 감소, 시공성 저하 등의 문제를 해결하기 위하여 재료 자체가 경량이고 부식이 적은 탄소섬유, 유리섬유, 아라미드 섬유 등과 같은 FRP(Fiber Reinforced polymer)재료를 이용하여 보강하는 공법이 널리 이용되고 있다. 또한, 많은 연구를 통하여 FRP 외부 부착 공법이 철근 콘크리트 구조물에 있어 보, 기둥, 슬래브 등의 주요 부재의 구조적인 보강에 아주 효과적인 것으로 증명되었다. 섬유시트를 구조물에 부착하여 보강하는 방법은 보강재의 탈락으로 인한 보강효과의 상실 및 구조부재의 파괴가 가장 큰 취약점으로 꼽히고 있다. 특히 보강재의 탈락은 서서히 발생하는 것이 아니라 갑자기 일어나는 현상이기 때문에 예측이 어렵고, 콘크리트의 피복과 함께 탈락하게 되는 경우에는 구조부재 자체에도 피해를 끼칠 수 있어 그 위험성이 크다. 따라서 본 기사에서는 FRP로 휨 보강된 철근 콘크리트 보의 파괴 모드를 간략하게 소개하고, 부착 강도 분석 및 보강재 형상에 따른 구조거동 분석에 관한 기존 연구 동향을 살펴보고자 한다. 마지막으로 최근 활발하게 연구되고 있는 FRP 앵커리지 시스템에서도 소개하고자 한다.
        4,000원
        126.
        2013.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper presents the design, fabrication and performance of a reinforced concrete beam strengthened by GFRP box plate and its possibility for structural rehabilitations. The load capacity, ductility and failure mode of reinforced concrete structures strengthened by FRP box plate were investigated and compared with traditional FRP plate strengthening method. This is intended to assess the feasibility of using FRP box plate for repair and strengthening of damaged RC beams. A series of four-point bending tests were conducted on RC beams with or without strengthening FRP systems the influence of concrete cover thickness on the performance of overall stiffness of the structure. The parameters obtained by the experimental studies were the stiffness, strength, crack width and pattern, failure mode, respectively. The test yielded complete load-deflection curves from which the increase in load capacity and the failure mode was evaluated.
        4,000원
        128.
        2012.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study proposes flexural failure design criteria of continuous slabs enhanced by a hybrid system of fiber reinforced polymer (FRP) and ultra high performance concrete (UHPC). The proposed hybrid retrofit system is designed to be placed at the top surface of the slabs for flexural strengthening of the sections in both positive and negative moment zones. The enhancing mechanisms of the proposed system for both positive and negative moment regions are presented. The neutral axis of the enhanced sections in positive moment zone at flexural failure is enforced to be in UHPC overlay for preventing the compression in FRP. From this condition, a relationship between design parameters of FRP and UHPC is established. Although the capacity of the proposed retrofit system to enhance flexural strength and ductility is confirmed through experiments of one-way RC slabs having two continuous spans, the retrofitted slabs failed in shear. To prevent this shear failure, a design criteria of flexural failure is proposed.
        4,000원
        129.
        2012.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 유리단섬유로 보강된 분사식 섬유보강 복합재료의 인장거동 평가를 위한 실험 및 해석연구를 수행하였다. 이를 위해 다양한 변형율속도(strain rate)에 따른 에폭시수지 및 분사식 섬유보강 복합재료의 인장강도 실험을 수행하였다. 본 연구에 사용된 분사식 섬유보강 복합재료는 15mm 길이로 절단된 유리단섬유가 25% 부피비율로 혼입된 보수·보강용 재 료이다. 에폭시수지의 점탄성 특성을 고려하기 위해 역산모델링(inverse simulation)을 수행하여 변형율속도에 따른 점성변화 를 함수식으로 제안하였다. 역산모델링을 통해 제안된 함수식을 미세역학 기반의 점탄성 손상모델(micromechanics-based viscoelastic damage model; Yang et al., 2012)에 적용하여 분사식 섬유보강 복합재료의 인장거동을 수치적으로 해석하였다. 분사식 섬유보강 복합재료의 인장거동 해석결과와 실험결과를 비교하여 미세역학 기반의 점탄성 손상모델의 정확성을 검증 하였다.
        4,000원
        130.
        2012.04 구독 인증기관·개인회원 무료
        An FRP(fiber reinforced polymer)-concrete hybrid hollow offshore wind power tower was proposed. To design this new-type wind tower, a design program was developed. It can design optimized sections automatically with the consideration of material nonlinearities. When the outer diameter and requested capacities of the hybrid tower are given, the developed program performs axial force-bending moment interaction analyses for one thousand sections of the tower and suggests ten economically optimized designs. The analysis considers material nonlinearities of concrete and FRP, and the confining effect of concrete. By using the developed program, example design processes were performed for a 5.0MW turbine and a 3.6MW turbine. The designing process was performed for the loads of wind power turbine and wind load. The designed section and analysis results showed the developed program suggested rational and satisfactory section designs.
        131.
        2012.04 구독 인증기관·개인회원 무료
        This study proposes a hybrid system of fiber reinforced polymer (FRP) and ultra high performance concrete (UHPC) to enhance flexural strength of existing reinforced concrete (RC) slabs. The proposed system is designed to be placed at the top surface of the slabs for flexural strengthening of the sections in both positive and negative moment zones. The enhancing mechanisms of the proposed system for both positive and negative moment regions are presented. Moreover, to prevent the compression in FRP of the enhanced sections in positive moment zone at flexural failure, neutral axis of the sections at failure is enforced to be in UHPC overlay. From this condition, a relationship between design parameters of FRP and UHPC is established.
        132.
        2012.04 구독 인증기관·개인회원 무료
        FRP products have been widely used in various fields of industry because of possessing high-strengths, corrosion resistance. Accordingly the waste FRP have also been increased and the effective recycling methods of waste FRP are needed. In this study, polymer mortar specimens were prepared with the various substitution amount of waste FRP powder. For finding the mechanical properties of polymer mortar added with waste FRP powder, compressive strength tests are conducted. From the test, we could find that compressive strength was increased with respect to the amount of waste FRP powder.
        133.
        2012.04 구독 인증기관·개인회원 무료
        Rehabilitation of existing steel structure attached to a steel because cross-section is generally raising. But when the area of reinforcement increases, also increases the weight of steel can cause degradation of the operations. In addition, welding process cause discomfort which due to the interference of other process. To replace the existing method, there are researches and applications for civil steel structures on the outside. In this study, bond performance of FRP and Steel were tested to reinforce steel structures by using AFRP as well as CFRP.
        134.
        2012.04 구독 인증기관·개인회원 무료
        In this study, the performance of a steel-FRP composite bridge safety barrier was evaluated through the vehicle crash test. Glass fiber and polyester resin were used for FRP. The structural strength performance, the passenger protection performance, and the vehicle behavior after crash were evaluated corresponding to the vehicle crash manual. As the result, A steel-FRP composite safety barrier was satisfied with the required performance.
        135.
        2012.04 구독 인증기관·개인회원 무료
        In this paper, we present the results of experimental investigation pertaining to the structural behavior of Tee joint connection composed of pultruded I-shape FRP members. In this study, we focus on the evaluation of load carrying capacity of Tee joint which appeared frequently to fabricate framed structure composed of pultruded FRP members. Through the experimental investigation moment-rotation relationship is found and the result is used to estimate the rotaion stiffness.
        136.
        2011.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 연구는 새로운 형태의 FRP-콘크리트 합성말뚝인 하이브리드 CFFT(HCFFT)를 개발하는 과정의 일부이다. 이 논 문에서는 CFFT와 HCFFT의 압축강도실험을 통하여 구조적 거동을 분석하였다. 압축강도실험에 앞서 PFRP와 FFRP 재료의 역학적 성질을 조사하였다. HCFFT 압축강도실험은 콘크리트 강도와 FFRP의 두께를 변수로 하여 실험을 수 행하였다. 그리고, FFRP 두께를 변수로 PFRP를 제외한 CFFT 실험체를 제작하고 실험을 수행하여 HCFFT와 비교· 분석하였다. 실험 결과, HCFFT의 압축강도는 CFFT에 비하여 11~47% 향상되는 것으로 나타났다. 실험구간내의 필 라멘트 와인딩 FRP 보강두께의 증가에 따른 HCFFT의 압축강도는 선형으로 증가시키는 것으로 나타났다. 또한 실 험체와 동일한 조건의 유한요소해석을 수행하였다. 해석결과는 실험결과에 비하여 모든 시편에서 약간 작은 값을 보였으며, 0.14%에서 17.95%까지의 오차범위 내에 있음을 알 수 있었다.
        4,000원
        137.
        2011.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 컴퓨터 시뮬레이션을 통해 강재-FRP 합성 교량용 방호울타리의 성능을 분석하였다. FRP는 Surface veil, DB 그리고 Roving 섬유로 구성하였다. FRP의 적층을 고려하기 위해 LS-DYNA에서 제공하는 재료모델 MAT58을 사용하였다. 강관과 FRP의 접촉조건을 고려하기 위해 Spot weld 옵션을 사용하였다. 실차충돌 실무 업무편람에 따 라 구조적 강도성능, 탑승자 보호성능 및 충돌 후 차량의 거동에 대한 성능평가를 실시하였다. 강재-FRP 합성 방호 울타리는 성능평가를 만족하였다.
        4,000원
        138.
        2011.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 한국산업표준에서 제시하는 콘크리트 강도 시험용 공시체를 이용하여 콘크리트 보강용 FRP의 부착 성능을 평가하기 위한 실험방법을 제안하고 이에 따라 FRP의 부착성능을 평가해 보도록 한다. 따라서 탄소섬유와 유리섬유로 이루어진 FRP를 두 겹으로 보강하여 양생한 철근 콘크리트 보에서 보강재의 탈락이 유도될 수 있도록 실험체를 설계하고, 3점 재하 시 적절한 파괴형상 및 부착강도가 나타나는 지를 실험을 통해 관찰하였다. 실험결과, 보강재의 탈락으로 인한 파괴가 유도되었으므로, 본 연구에서 제안된 실험방법을 통하여 크기가 작은 일반강도 콘 크리트 실험체에서 FRP의 부착강도를 평가할 수 있는 것으로 사료된다.
        4,000원
        140.
        2011.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        콘크리트 포장의 다웰바는 교통하중을 줄눈 넘어 인접한 슬래브로 전달하는 하중전달장치이다. 현재 국내에서 사용되는 다웰바는 원형봉강으로 교통하중과 환경하중으로 인해 반복적으로 발생하는 전단응력과 휨응력에 대해 높은 내구성을 갖고 있다. 그러나, 강재 다웰바는 장기간 공용시 줄눈틈, 포장 하부 등으로 침투한 수분으로 인해 부식이 발생한다. 특히, 겨울철에 사용되는 제설용 염수와 접촉할 경우 부식은 급격히 진행된다. 다웰바에 부식이 발생하면 부피가 증가하여 줄눈의 거동을 방해하며 유효단면적의 감소로 하중전달효과가 떨어질 수 있다. 이와 함께 지속적인 원자재 가격의 상승으로 강재 다웰바의 가격 경쟁력이 크게 낮아지고 있다. 이러한 강재 다웰바의 문제점은 새로운 재료를 사용한 대체 다웰바의 개발로 이어지고 있다. 본 연구에서는 높은 인장강도, 높은 내부식성을 갖춘 FRP(fiber reinforced plastic)를 튜브 형태로 제작하고 그 속을 고강도 무수축 모르타르로 충진한 FRP 튜브 다웰바에 대한 역학적 두께 설계를 실시하였다. 역학적 두께 설계의 기준으로 다웰바와 콘크리트 면 사이에 발생하는 지압응력을 사용하였다. 지압응력의 산정을 위하여 다웰바에 전달되는 교통하중을 이론식과 유한요소해석을 통해 산출하고 실내시험을 통해 FRP 튜브 다웰바의 물성을 측정하였다. 그 결과, 직경 32mm, 40mm FRP 튜브 다웰바 모두 지압응력 기준을 만족하는 것으로 나타났다. 국내 콘크리트 포장은 콘크리트 슬래브 하부에 강성이 큰 린 콘크리트층을 사용하기 때문에 다웰바에 전달되는 교통하중이 적고 이로 인해 지압응력도 낮아져 상대적으로 적은 직경의 FRP 튜브 다웰바의 사용이 가능한 것으로 판단된다.
        4,000원