검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 23

        2.
        2020.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In a previous paper, ambient vibration tests were conducted on a cable stayed bridge with resilient-friction base isolation systems (R-FBI) to extract the dynamic characteristics of the bridge and compare the results with a seismic analysis model. In this paper, a nonlinear seismic analysis model was established for analysis of the bridge to compare the difference in seismic responses between nonlinear time history analysis and multi-mode spectral analysis methods in the seismic design phase of cable supported bridges. Through these studies, it was confirmed that the seismic design procedures of the “Korean Highway Bridge Design Code (Limit State Design) for Cable Supported Bridges” is not suitable for cable supported bridges installed with R-FBI. Therefore, to reflect the actual dynamic characteristics of the R-FBI installed on cable-supported bridges, an improved seismic design procedure is proposed that applies the seismic analysis method differently depending on the seismic isolation effect of the R-FBI for each seismic performance level.
        4,000원
        3.
        2020.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, a field bridge test was conducted to find the dynamic properties of cable supported bridges with resilient-friction base isolation systems (R-FBI). Various ambient vibration tests were performed to estimate dynamic properties of a test bridge using trucks in a non-transportation state before opening of the bridge and by ordinary traffic loadings about one year later after opening of the bridge. The dynamic properties found from the results of the tests were compared with an analysis model. From the result of the ambient vibration tests of the cable supported bridge with R-FBI, it was confirmed that the dynamic properties were sensitive to the stiffness of the R-FBI in the bridge, and the seismic analysis model of the test bridge using the effective stiffness of the R-FBI was insufficient for reflecting the dynamic behavior of the bridge. In the case of cable supported bridges, the seismic design must follow the “Korean Highway Bridge Design Code (Limit State Design) for Cable supported bridges.” Therefore, in order to reflect the actual behavior characteristics of the R-FBI installed on cable-supported bridges, an improved seismic design procedure should be proposed.
        4,200원
        4.
        2013.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문은 교량 하부에서 발생된 화재에 대한 강-콘크리트 합성구조의 전반적·국부적 손상평가를 위한 수치해석적 연구이다. 수치해석의 정확성 및 효율성을 높이기 위해 구성재료의 과도 비선형 열적·열역학적 특성이 고려된 열-구조 연성병렬 화재해석 기법이 제안되고, ANSYS solver와 연결되어 해석이 수행되며, 표준화재시험과 비교·검증된다. 검증된 해석기법을 통해 국내에서 발생된 부천고가교 합성구조에 대한 화재손상해석이 수행된다. 해석결과 강박스 거더의 하부 플랜지 및 복부의 경우 임계온도를 초과하였고 구조적 처짐과 변형 형상이 화재사고 결과와 비교적 잘 일치하였다.
        4,000원
        5.
        2012.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 다채널 자속누설 센서를 이용하여 강케이블의 국부손상을 검색하였다. 먼저 자속누설 기법을 고정된 케 이블 구조물에 적용하기 위해 프로토타입의 8채널 자속누설 센서헤드를 제작하였고, 국부손상이 발생한 케이블을 구현하 기 위하여 PVC 파이프에 강케이블을 채워 강케이블 다발 시편을 제작하였고, 케이블 시편 외부 및 내부에 다양한 크기 및 방향을 가지는 국부손상을 단계적으로 발생시켰다. 이와 같이 제작된 강케이블 시편을 대상으로 각 손상단계에서 자속누설 센서헤드를 이용하여 자속신호를 스캔하고 출력전압으로 표현하였다. 이어서 일반극치분포를 이용해 손상유무를 판단할 수 있는 기준이 되어줄 임계값을 설정하였고, 이를 각 채널에서 계측된 자속신호와 비교하여 객관적인 손상판단을 수행하 였다. 또한 케이블 모니터링에 있어 가장 중요한 정보인 손상의 길이방향 위치를 효과적으로 검색하기 위해 모든 채널의 자속값을 합하여 총합값의 형태로 임계값과 함께 나타내었다. 최종적으로 임계값을 초과한 부분의 길이방향 및 원주방향 위치를 실제 손상과 비교함으로써 본 기법의 국부손상 검색 가능성을 살펴보았다.
        4,000원
        6.
        2018.10 서비스 종료(열람 제한)
        It is important to operate appropriate measurement system of cable bridges for the efficient construction and maintenance. The main results of study on the optimal construction detail method of measurement for individual cable bridge are described. In this paper, the basic guidelines for the cable bridges measurement system is presented such as sensor classification, installation location and performance standard for the installation of the optimal measurement system of cable bridges on expressways.
        7.
        2018.04 서비스 종료(열람 제한)
        It is important to operate appropriate measurement system of cable bridges for the efficient construction and maintenance. The main results of study on the optimal construction detail method of measurement for individual cable bridge are described. In this paper, the basic guidelines for the cable bridges measurement system is presented such as sensor classification, installation location and performance standard for the installation of the optimal measurement system of cable bridges on expressways.
        8.
        2017.09 서비스 종료(열람 제한)
        This study is a method to improve the reliability and effectivity of maintenance. It is necessary to build the integrated management system of BIM throughout the design, construction and maintenance of the structure. In order to apply BIM, it was introduced structural record management from the design stage. And It helps to improve the reliability of maintenance.
        9.
        2017.04 서비스 종료(열람 제한)
        To monitor structural responses and detect serious events, an image-based health monitoring technology for existing bridges has been developed. The image-based system allows users to connect and remotely control cameras in real-time. The developed system was successfully tested and verified in the test bed bridges. This paper presents the application examples of it.
        10.
        2017.01 KCI 등재 서비스 종료(열람 제한)
        To monitor structural responses and detect serious events, an image-based health monitoring technology for existing bridges has been developed. The image-based system allows users to connect and remotely control cameras in real-time. The developed system was successfully tested and verified in the test bed bridges. This paper presents the application examples of it.
        11.
        2016.10 서비스 종료(열람 제한)
        Road bridges are affected by de-icing chemicals, which are used to prevent snow and ice on the road. Corrosion of steel girders due to de-icing chemicals are becoming common problems. The deterioration of steel girder ends due to deck joint leakage and occasional spray from passing vehicles usually cause section losses and strength reduction. This report presents th results of a study carried out to repair corroded steel box girder bridge.
        12.
        2016.10 서비스 종료(열람 제한)
        To monitor static and dynamic responses of bridges, an image-based monitoring system using networking Pan-Tilt-Zoom IP (Internet Protocol) cameras has been developed. Verification testing is carried out during the human-excited vibration test of the stay cables in a cable-stayed bridge. As well as identifying the natural frequencies of the stay cable, the reasonable damping ratios are successfully extracted from the acquired images.
        13.
        2016.09 KCI 등재 서비스 종료(열람 제한)
        차량충돌은 가장 빈도가 높은 교량 붕괴의 원인 중 하나로 알려져 있으며, 최근 재해에 대하여 대책 수립 및 관리의 필요성이 공익 안전을 위해 제기되고 있다. 본 연구에서는 차량 충돌로 인한 교량 피해에 대하여 위험도 분석을 실시하였다. 위험도 분석 단계는 세 단계로 구 분하였고, 예비위험분석 단계에서는 충돌의 발생가능성을 확인하며, 기본위험분석 단계에서는 발생가능성, 취약성, 중요도에 대한 위험도 점 수평가를 통한 위험도 등급을 산정하였다. 마지막 상세위험분석 단계에서는 위험도가 높은 등급에 대하여 상세분석을 실시한다. 본 연구에서 는 예비위험분석과 기본위험 단계에 집중하여 위험도 등급 구분을 위한 네 가지의 급간분류법을 적용하였다. 충돌 사례와 분석 결과를 비교하 여 적절한 급간분류법을 결정하고자 하였다. 본 연구에서 사용된 위험도 분석법은 유사한 재난에 대한 대책수립을 위해 사용될 수 있을 것이다.
        14.
        2016.04 서비스 종료(열람 제한)
        Bridges have been collapsed due to disaster, and this has required much of expenses. Vehicle collision cause critical damage on Bridges. This paper focus on vehicle collision risk level for highway bridges. In this study use 4 classification, Natural Break based Interval, Equal Interval, Standard Deviation based Interval and Reliability based Interval.
        15.
        2015.04 서비스 종료(열람 제한)
        To monitor static and dynamic responses of bridges, an image-based monitoring system using networking PTZ IP (Pan-Tilt-Zoom Internet Protocol) cameras has been developed. Triggers to acquire video or still-images are performed when structural events like vibrations or excessive displacements occur. Also, periodic or user-defined triggers can be performed. When a trigger occurs, the system collects bridge members' images along the pre-defined touring route of a group of presets and extracts relative displacements between images.
        16.
        2015.04 서비스 종료(열람 제한)
        본 논문은 최근 화물차량 적재물의 충돌로 인해 고속도로상 강박스거더교 하부에 발생한 손상 현황과 손상 부위별로 제안된 보수‧보강 방안을 살펴보고자 한다.
        17.
        2015.04 서비스 종료(열람 제한)
        This paper aims at optimizing fire risk assessment for highway bridges using different classification schemes. Based on results, highway bridges are categorized into three groups according to fire risk levels and compared to actual cases of fire incidents. From comparisons, it is required to determine the proper classification scheme according to type of risk and data.
        18.
        2014.10 서비스 종료(열람 제한)
        This study examined the collapse of bridge under extreme events. As a result, numerous bridges collapsed by scour, collision, fire and earthquake. The research team studied four cases of previous bridge collapse and restoration following extreme events. Finally, the disaster type factor were selected.
        19.
        2014.04 서비스 종료(열람 제한)
        To monitor dynamic responses of bridges, the vision-based system using commercial video-related equipment is developed. The research and development has been performed for dynamic characteristics extraction of external tendons in PSC box girder bridges. The vision-based dynamic measurement system consists of an industrial camera and notebook computer that can measure tendon's vibrations with 100 fps. The vision-based system was successfully tested and verified in the testbed bridge.
        20.
        2013.10 서비스 종료(열람 제한)
        This study developed a fire risk assessment procedure for the bridges on the highway. The fire risk assessment consists of three part. PRA, SRA, and DRA. with The preliminary risk analysis (PRA), considering the bridge to need analysis. The simplified risk Analysis (SRA) assesses the risk level of the bridge based on bridge information database. detailed risk analysis (DRA) conducts for high risk bridge in the SRA. In SRA, factors which influence fire event occurrence and vulnerability are investigated. based on risk assessment, select proper countermeasures.
        1 2