In this study, an evaluation system that can be used to evaluate the feasibility of developing and supplying hydrothermal energy for the operation of large-scale complex facilities was developed. To this end, this study derived factors to be considered when selecting a location for the use of hydrothermal energy using raw water from multi-purpose dams and regional water supply systems through literature survey and expert interviews. The evaluation indicators derived from this study are divided into four sectors: hydrothermal energy utilization factors, location factors, planning factors, and disaster safety factors, and are composed of 10 mid-level indicators and 34 detailed planning indicators. The relative importance of all factors was derived using the Analytic Hierarchy Process (AHP) technique, and the developed evaluation indicators and relative importance were applied to four multi-purpose dam regions in the country. As a result, it was found that in the development and use of hydrothermal energy utilizing regional raw water supply line the urban planning conditions of the supply site can have a greater impact on the location selection results than the hydrothermal energy development itself. Due to the characteristics of the evaluation indicators developed in this study and their nature as comprehensive indicators, it is believed that the results should be applied to determine the overall adequacy of site selection in the early stages of hydrothermal energy development. In the future, it is believed that it will be necessary to analyze the problems in supplying and operating hydrothermal energy using raw water from multi-purpose dams and regional water resources. Based on the analysis the evaluation system developed in this study is expected to be improved and supplemented.
In this study, non-destructive technologies that can be applied to evaluate the integrity of valve materials, safety against internal pressure caused by corrosion, and the blocking function of large-diameter water valves during operation without requiring specimen collection or manpower entering the inside of the valve were tested to assess the reliability of the technologies and their suitability for field application. The results showed that the condition of the graphite structure inside the valve body can be evaluated directly through the optical microscope in the field without specimen collection for large-diameter water butterfly valves, and the depth of corrosion inside the valve body can be determined by array ultrasound and the tensile strength can be measured by instrumented indentation test. The reliability of each of these non-destructive techniques is high, and they can be widely used to evaluate the condition of steel or cast iron pipes that are significantly smaller in thickness than valves. Evaluation of blocking function of the valves with mixed gas showed that it can be detected even when a very low flow rate of mixed gas passes through the disk along with the water flow. Finally, as a result of evaluating the field applicability of non-destructive technologies for three old butterfly valves installed in the US industrial water pipeline, it was found that it is possible to check the material and determine the suitability of large-diameter water valves without taking samples, and to determine the corrosion state and mechanical strength. In addition, it was possible to evaluate safety through the measurement results, and it is judged that the evaluation of the blocking function using mixed gas will help strengthen preventive response in the event of an accident.
In this study, based on the System Dynamics (SD) methodology, the interrelationship between the factors inherent in the operation of the New Technology Certification System (NTCS) in Korea was identified by a causal map containing a feedback loop mechanism in connection with ‘new technology development investment’, ‘commercialization of new technology’, and ‘sales by new technology’. This conceptualized causal map was applied to the simulation of the operations of the New Excellent Technology and Environmental Technology Verification System (NET&ETV) run by the Ministry of Environment among various NTCSs in Korea. A SD computer simulation model was developed to analyze and predict the operational performance of the NET&ETV in terms of key performance indices such as ‘sales by new technology’. Using this model, we predicted the future operational status the NET&ETV and found a policy leverage that greatly influences the operation of the NET&ETV. Also the sensitivity of the key indicators to changes in the external variables in the model was analyzed to find policy leverage.
In this paper the potential of the principal component analysis(PCA) technique for the application of detecting leaks in water pipe networks was evaluated. For this purpose the PCA was conducted to evaluate the relevance of the calculated outliers of a PCA model utilizing the recorded pipe flows and the recorded pipe leak incidents of a case study water distribution system. The PCA technique was enhanced by applying the computational algorithms developed in this study which were designed to extract a partial set of flow data from the original 24 hour flow data so that the effective outlier detection rate was maximized. The relevance of the calculated outliers of a PCA model and the recorded pipe leak incidents was analyzed. The developed algorithm may be applied in determining further leak detection field work for water distribution blocks that have more than 70% of the effective outlier detection rate. However, the analysis suggested that further development on the algorithm is needed to enhance the applicability of the PCA in detecting leaks by considering series of leak reports happening in a relatively short period.
In this paper a concept of the paradigm shift in the operations of Water and Wastewater systems regarding the production and usage of water was introduced. Based on this concept the interrelationships between the water quality in the upper basin of NakDong River relative to Busan and the degree of satisfaction of the customers on the water supply service in Busan were modeled using the System Dynamics modeling methodology. SamRangJin basin area was determined as the upper basin of Busan after analyzing the relationships between the water quality of MoolGeum water intake point and water quality data of various mid- and upper water intake points along NakDong River. The amount of contaminants generated in SamRangJin basin was modeled using the Gross Regional Domestic Product in the area and the treated amount was calculated using the efficiency of wastewater treatment and the degree of improvement of environmental condition per investment. The water quality at MoolGeum water intake point was modeled to take the effects of the remaining amount of contaminants after treatment and the non-point source contaminants in SamRangJin basin. Using the developed System Dynamics model the effects of the investment for the improvement of environmental condition in SamRangJin basin were compared to the case of alternate water source development for Busan in terms of the degree of satisfaction of the customers on the water supply service in Busan.
Aging water pipe networks hinder efficient management of important water service indices such as revenue water and leakage ratio due to pipe breakage and malfunctioning of pipe appurtenance. In order to control leakage in water pipe networks, various methods such as the minimum night flow analysis and sound waves method have been used. However, the accuracy and efficiency of detecting water leak by these methods need to be improved due to the increase of water consumption at night. In this study the Principal Component Analysis (PCA) technique was applied to the night water flow data of 426 days collected from a water distribution system in the interval of one hour. Based on the PCA technique, computational algorithms were developed to narrow the time windows for efficient execution of leak detection job. The algorithms were programmed on computer using the MATLAB. The presented techniques are expected to contribute to the efficient management of water pipe networks by providing more effective time windows for the detection of the anomaly of pipe network such as leak or abnormal demand.
In this paper, a System Dynamics(SD) computer simulation model has been developed to assess the effects of developing and providing an alternate water source. A water service index was also developed to estimate the level of overall customer satisfaction on water supply service. Data from the Busan water supply service and the Korea Development Institute regarding the Nak Dong river bank storage development were utilized during the modeling processes. Some important indicators of the system under study were analyzed by the simulations of development of the alternate water source for Busan. The developed SD model and the water service index can be further utilized as a tool that can assess the extent and timing of an additional service improvement project.
본 논문에서는 상수관로의 효율적인 유지 관리를 위해 상수도 기술진단에서 점수평가법으로 도출된 관망성능평가결과를 이용한 상수도 관로의 내구연수 및 잔존수명 산정 방법을 제시하였다. 본 연구에서 잔존수명은 ‘모델에 의해 추정된 매설 후 최적교체시기까지 경과년수’를 의미하는 ‘내구연수’와 매설 후 경과년수의 차이로 정의하였으며, 내구연수는 관망성능평가기준으로 제시된 노후관로 판정기준 점수에 도달하는 시점으로 정의하였다. 연구대상지역의 관망성능평가에 사용된 평가항목들과 노후도 점수를 상수도 관로의 잔존수명 추정을 위한 다중회귀모델의 변수로 사용하였다. 잔존수명의 산정에 필요한 내구연수를 추정하기 위하여 구축된 회귀모델에 독립변수로 사용된 노후도 점수를 나타내는 변수의 값으로 노후관로 판정기준 점수에 해당하는 값을 대입하였다. 개발된 회귀모델을 이용하여 연구대상지역 상수도 관로의 내구연수 및 잔존수명을 산정하였으며 그 결과를 지방공기업법에서 제시하고 있는 내용연수와 비교하여 분석하였다.
본 논문에서는 시스템 다이내믹스(System Dynamics, SD) 방법론에 입각하여 하수도 시스템의 운영지표들과 이에 영향을 미치는 외부변수들로 구성된 피드백 루프 메커니즘(Feedback Loop Mechanism)을 관로유지관리와 연관하여 규명하고, 외부변수의 변화에 따른 운영지표의 변화를 예측함으로써 하수도 시스템의 효율적인 운영 및 유지관리 방안을 모색할 수 있는 SD 컴퓨터 모의 모형(Computer Simulation Model)을 개발하였다. 개발된 모형에 부산광역시 하수도 시스템의 과거 운영 자료를 적용함으로써 모형을 검증하였고, 미래의 운영 상황을 예측하였다. 그 결과, 하수도보급률은 이미 목표치에 거의 도달하여 큰 변동이 없을 것으로 예측되었으며, 하수처리효율과 하수처리량, 요금현실화율은 점차 증가할 것으로 예측되었다. 또한 정책 지렛대의 발견을 위해 시스템에 큰 영향을 미치는 주요 운영지표를 선정하여 외부변수의 변화에 대한 민감도 분석을 수행하였는데, 그 결과 관로 유지관리와 연관된 외부변수는 하수처리효율의 변화뿐만 아니라 시설이용률, 하수처리량 등의 변화에도 큰 영향을 미치는 것으로 분석되었다.
본 논문에서는 상수관로의 개량(교체또는갱생) 우선순위를 결정하는데 있어서 평가되어야 할 인자 또는 요소를 관로의 파손이 전체관망에 미치는 영향 및 개별관로의 특성으로 구분하였고, 이들을 퍼지기법을 적용하여 정량적으로 산정할 수 있는 모형을 개발하였다. 퍼지기법으로 산정되는 관로의 파손이 전체관망에 미치는 영향을 관로의 퍼지 중요도로 정의하였으며, 개별관로의 특성은 관로의 퍼지 특성도로 정의하였다. 퍼지 특성도는 다시 퍼지 노후도 및 퍼지 난이도 등으로
본 논문에서는 시스템다이내믹스(System Dynamics, SD) 방법론에 입각하여 상수도 시스템의 운영에 내재된 피드백 루프 메커니즘(feedback loop mechanism)을 상수관로의 유지관리와 연관하여 규명하고, 관로 상태의 변화가 전체 시스템에 미치는 영향을포함한 상수도 시스템의 운영지표를예측하여 상수도 시스템의 효율적인운영 및 유지관리를 지원할 수 있는 SD 컴퓨터 모의 모형(simulation model)을 개발하였다. 개발된 모형은
본 연구에서는 상수관망에서 개별적으로 노후도가 심하여 개량이 필요한 구간을 보다 정확하게 구분하기 위해 새로운 개별관로 정의 방법이 개발되었다. 적절한 관로 최소구성성분 길이를 결정하기 위하여 여러 가지 관로 최소구성성분 길이에 대한 평균 누적파손횟수경사선의 분산값을 비교하여 가장 큰 분산값을 나타내는 관로 최소구성성분 길이인 4 m 를 연구대상 지역의 상수관망에 적용하였으며 관로 ID는 39개로 구분되어졌다. 관로의 경제적 최적교체 시기는 한계파손율과
본 논문에서는 상수관로의 파손자료를 이용하여 관로의 위험률을 산정하기 위해 사용되는 비례위험모형의 관로의 순차적 파손시간 예측정확도를 분석하고 이를 이용하여 관로의 경제적 교체 시간구간을 산정할 수 있는 방법론을 제시하였다. 비례위험모형에 기초한 생존함수를 이용하여 연구대상 관로들의 순차적 파손시간을 예측하고 이들을 기록된 파손시간과의 차이를 분석하였다. 이를 통하여 비례위험모형의 파손시간 예측 오차를 최소화하는 생존확률은 0.70인 것으로 결정되었으며
본 논문에서는 연구대상 지역의 150 mm 주철 상수관로의 첫 번째 파손으로부터 일곱 번째 파손사건에 대한 비례 위험모형을 구축하였다. 모형의 구축과정에서 공변수의 위험률에 대한 비례위험 가정을 검사하여 이를 위배할 경우 시간종속형 공변수로 모형화하였다. 그 결과 첫 번째 파손에 대해서는 관로의 제원 및 연결 방식과 급수인구가, 그리고 두 번째 파손 사건에 대해서는 급수인구의 영향이 시간에 따라 변하는 것으로 나타났다. 각 생존시간군의 기저위험률에 대한
노후수도관 개량사업은 예산상, 시공상 등의 여러 제약조건에 의해서 장기적인 계획 하에 시행되게 된다. 본 연구에서는 연구대상지역에서 1992년부터 1997년 사이에 기록된 누수 위치좌표 약 8,000개를 이용하여 누수 위치들 간의 공간적 상관관계에 대한 계층적 군집분석을 수행한다. 계층적 군집분석방법 중 최단 연결법, 최장 연결법 및 평균 연결법을 적용하여 연구대상지역을 누수위치의 공간적 상관관계에 따라 분할하였으며, 각 군집 방법 별로 분할된 구역들을
상수관망에서 다양한 제수밸브 분포간의 우열성 평가는 상수관망의 신뢰성 확보를 위해 필수적이다. 기존 상수관망에 새로운 제수밸브를 추가할 경우나 새로운 상수관망을 건설할 경우, 본 연구에서는 서로 다른 제수밸브 분포간의 우열성을 평가하여 좀 더 효율적인 제수밸브 분포를 선택할 수 있는 방법을 제안하고자 한다. 제안된 방법은 상수관 및 제수밸브의 파괴 모의를 바탕으로 하며 제수밸브 분포간의 우열성은 상수관망의 신뢰도를 기준으로 하였다. 상수관망의 신뢰도는
본 논문에서는 대수-선형 파손율 모형(log-linear ROCOF)과 와이블 파솔율 모형(Weibull ROCOF)을 이용하여 상수도 주철 배수관로의 파손율을 모형화하고, '수정된 시간 척도'를 이용하여 최적교체시기를 산정할 수 있는 방법이 개발되었다. 두 ROCOF의 모형화를 위하여 개별 관로의 파손시간을 기록한 '파손 시간자료(failure-time data)'와 일정 시간간격 사이에서 발생하는 파손횟수를 기록한 '파손 횟수자료(failure-nu