검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 26

        21.
        1988.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        4,000원
        23.
        1998.12 KCI 등재 서비스 종료(열람 제한)
        A recently constructed commercial ship is a complexive integrated system like a small city in which has a generator, power distributing facilities, various radio equipments and high power circuit breakers are installed. Therfore it could make a malfunction of the microprocessor in the various control units which are so important during the ocean voyage of larger ship. This paper has studied whether is properly required or not on the view of the actual electro magnetic compatibility status on the electromagnetic interference and suceptibility test requirments listed on the IACS (International Association of the Classification Society). Through these results, we are looking forward to the new suggestions of the Electro Magnetic Compatibility test in order to reduce the malfunction in the ship regarding test item, test level, and test condition.
        24.
        1997.09 KCI 등재 서비스 종료(열람 제한)
        현재 자동차나 선박등에 사용하는 직류모터 속도 제어용 스위칭 소자는 스위칭 과전압으로 인하여 때때로 손상되거나 오작동을 일으키기쉽다. 본논문은 dc 모터 제어용 반도체 스위칭소자의 내성특성을 개선한 것이다. 이를 위하여, 먼저 저전압 보호소자인 비리스터나 제너 다이오드 등 가운데에서 스위칭 과전압에 대해 내성을 갖는 이상적인 소자를 선택하기 위해 과전압 보호자의 등가회로를 분석 하였다. 나아가서 국제규정에서 정의된 의사 과전압 파형의 적절한 선택, 스위칭 소자의 손상과정과 손상원인을 규명하고, 순시과전압 전류의 변화에 따른 각각의 임피던스 조건을 고려하여 직류모터 제어용 반도체 스위칭 소자의 내성특성 개선하였다.
        25.
        1995.08 KCI 등재 서비스 종료(열람 제한)
        IEC and CISPR have continuously endeavored the measurement method of Immunity Test as international unification, but not established yet. The main reason is that the measurement method and the normalization of threshold to obtain the complicated parameters for Immunity Test are difficult. Thus, the Immunity Test Setups are used differently according to the measured electromagnetic environments. This study developed an Immunity Test System and Algorithm for measurement software suitable for IEC801-3 Regulatons using ready-made amplifier, signal generator, and developes interconnecting interface board interacting with other appratus i.e., RF Switch, Power Meter, Field Sensor and Pre-amp. We are to develope an automated software using Top/Down and OOP(Object Oriented Programming) method.
        26.
        1995.05 KCI 등재 서비스 종료(열람 제한)
        Since the most of the mal-functions in the industrial equipments controlled by processors have been occured by the Electrical Fast Transient(EFT), the International Electrotechnical Commision(IEC) prepare the dummy signal to test the immunity level of the equipments controlled by processors and recommend it for the measuring. In this paper, the defined dummy EFT signal by IEC are analyzed by the spectrum analyzer in the frequency domain and studied the developed countermeasuring parts. The new developed parts are consist of the feedthrough capacitors ( Cy type ) in the input and materials with high permeaility which was wound or inserted in the second layer of the Power Cable in order to increase Common Mode inductance. And it is compared inserted Permalloy to material with high permeability increasing Common Mode inductance. We could gotten a excellent insertion loss on the wide band against EFT signal. Especially, we confirm that countermeasuring Power Cable have been an excellent dynamic characteristics in computer system above the 3.6Kv. This new parts could be effectively used for industrial, MIL, and medical equipments to reduce a mal-functions on the site. Furthermore, these parts also have a good characteristics for EMI countermeasuring over the 60MHz up to several GHz band, they are also expected to be used for all kind of EMS test with IEC801-2, 3, 5 and 6 on the power distributed line.
        1 2