검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 105

        41.
        2017.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES: The purpose of this study is to evaluate different types of Ground Penetrating Radar (GPR) testing for characterizing the road cavity detection. The impulse and step-frequency-type GPR tests were conducted on a full-scale testbed with an artificial void installation. After analyzing the response signals of GPR tests for detecting the road cavity, the characteristics of each GPR response was evaluated for a suitable selection of GPR tests. METHODS: Two different types of GPR tests were performed to estimate the limitation and accuracy for detecting the cavities underneath the asphalt pavement. The GPR signal responses were obtained from the testbed with different cavity sizes and depths. The detection limitation was identified by a signal penetration depth at a given cavity for impulse and step-frequency-type GPR testing. The unique signal characteristics was also observed at cavity sections. RESULTS: The impulse-type GPR detected the 500-mm length of cavity at a depth of 1.0 m, and the step-frequency-type GPR detected the cavity up to 1.5 m. This indicates that the detection capacity of the step-frequency type is better than the impulse type. The step-frequency GPR testing also can reflect the howling phenomena that can more accurately determine the cavity. CONCLUSIONS : It is found from this study that the step-frequency GPR testing is more suitable for the road cavity detection of asphalt pavement. The use of step-frequency GPR testing shows a distinct image at the cavity occurrences.
        4,000원
        42.
        2017.10 구독 인증기관·개인회원 무료
        본 연구는 도로함몰과 관련된 연구 중 위험도 등급에 따른 소성변형 특성을 파악하기 위해 수행되었다. 도로함몰 위험도 등급 A, B에 해당하는 지표면으로부터 60cm, 90cm 하부에 모의 동공(얼음)을 설치하였으며, 동공의 크기는 그림 1과 같이 너비와 높이는 50cm, 길이는 100cm, 200cm로 각각 설계하였다. 또한, 배수층을 20cm 설치하여 배수가 가능하도록 설계하였다. 포장가속시험은 4ton의 축하중으로 10km/h의 속도로 운영하였으며, 1,000회, 2,000회, 6,000회, 10,000회 운행 시 마다 소성변형량 변화를 측정하였다. 그 결과 동공의 크기보다는 동공의 깊이가 소성변형에 영향을 크게 미치는 것으로 파악되었다. 그림 1의 1,3번 동공은 폭과 높이는 유사하지만 길이가 각각 1m, 2m로 위험도 등급에서 B, A이다. 하지만, 소성변형량을 비교했을 때 각 횟수마다 비슷한 경향을 보이며 증가하는 추세를 볼 수 있었다. 또한, 2번 동공의 경우 포장층에 가깝게 동공이 형성되어 1,3번 동공과 달리 소성변형량 증가 추세가 다른 동공들에 비해 월등히 빨랐으며, 6,000회 이상 포장가속시험을 수행하기 어려울 정도로 소성변형이 심하게 나타났다. 포장가속시험 수행 결과 동공 생성 초기에 소성변형량 변화폭이 가장 크며, 동공 길이보다는 심도에 포장층이 영향을 크게 받는 것으로 나타났다.
        44.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        OBJECTIVES : The objective of this study is to analyze the nonlinear behavior of block pavements using multi-load level falling weight deflectometer (FWD) deflections. METHODS: Recently, block pavements are employed not only in sidewalks, but also in roadways. For the application of block pavements in roadways, the structural capacities of subbase and subgrade are important factors that support the carry traffic load. Multi-load level FWD testing was conducted on block pavements to analyze their nonlinear behavior. The deflection ratio due to the increase in load was analyzed to estimate the nonlinearity of block pavements. Finite element method with nonlinear soil model was applied to simulate the actual nonlinear behavior of the block pavement under different levels of load. RESULTS: The results of the FWD testing show that the center deflections in block pavements are approximately ten times greater than that in asphalt pavements. The deflection ratios of the block pavement due to the increase in the load range from 1.2 to 1.5, indicating that the deflection increased by 20~50%. The material coefficients of the nonlinear soil model were determined by comparing the measured deflections with the predicted deflections using the finite element method. CONCLUSIONS: In this study, the nonlinear behavior of block pavements was reviewed using multi-load level FWD testing. The deflection ratio proposed in this study can estimate the nonlinearity of block pavements. The use of nonlinear soil model in subbase and subgrade increases the accuracy of predicting deflections in finite element method.
        4,000원
        45.
        2016.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : The objective of this study is to evaluate the effect of size and depth of cavities on the pavement failure using the full-scale accelerated pavement testing. METHODS: A full-scale testbed was constructed by installing the artificial cavities at a depth of 0.3 m and 0.7 m from the pavement surface for accelerated pavement testing. The cavities were made of ice with a dimension of 0.5 m*0.5 m*0.3 m, and the thickness of asphalt and base layer were 0.2 m and 0.3 m, respectively. The ground penetrating radar and endoscope testing were conducted to determine the shape and location of cavities. The falling weight deflectometer testing was also performed on the cavity and intact sections to estimate the difference of structural capacity between the two sections. A wheel loading of 80 kN was applied on the pavement section with a speed of 10 km/h in accelerated pavement testing. The permanent deformation was measured periodically at a given number of repetitions. The correlation between the depth and size of cavities and pavement failure was investigated using the accelerated pavement testing results. RESULTS : It is found from FWD testing that the center deflection of cavity section is 10% greater than that of the intact section, indicating the 25% reduction of modulus in subbase layer due to the occurrence of the cavity. The measured permanent deformation of the intact section is approximately 10 mm at 90,000 load repetitions. However, for a cavity section of 0.7 m depth, a permanent deformation of 30 mm was measured at 90,000 load repetitions, which is three times greater than that of the intact section. At cavity section of 0.3 m, the permanent deformation reached up to approximately 90 mm and an elliptical hole occurred at pavement surface after testing. CONCLUSIONS : This study is aimed at determining the pavement failure mechanism due to the occurrence of cavities under the pavement using accelerated pavement testing. In the future, the accelerated pavement testing will be conducted at a pavement section with different depths and sizes of cavities. Test results will be utilized to establish the criteria of risk in road collapse based on the various conditions.
        4,000원
        46.
        2016.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES: The objective of this study was to determine the relationship between the dielectric characteristics of asphalt mixtures and the air voids present in them using ground penetrating radar (GPR) testing. METHODS : To measure the dielectric properties of the asphalt mixtures, the reflection coefficient method and the approach based on the actual thickness of the asphalt layer were used. An air-couple-type GPR antenna with a center frequency of 1 GHz was used to measure the time for reflection from the asphalt/base layer interface. A piece of aluminum foil was placed at the interface to be able to determine the reflection time of the GPR signal with accuracy. An asphalt pavement testbed was constructed, and asphalt mixtures with different compaction numbers were tested. After the GPR tests, the asphalt samples were cored and their thicknesses and number of air voids were measured in the laboratory. RESULTS: It was found the dielectric constant of asphalt mixtures tends to decrease with an increase in the number of air voids. The dielectric constant values estimated from the reflection coefficient method exhibited a slight correlation to the number of air voids. However, the dielectric constant values measured using the approach based on the actual asphalt layer thickness were closely related to the asphalt mixture density. Based on these results, a regression equation to determine the number of air voids in asphalt mixtures using the GPR test method was proposed. CONCLUSIONS: It was concluded that the number of air voids in an asphalt mixture can be calculated based on the dielectric constant of the mixture as determined by GPR testing. It was also found that the number of air voids was exponentially related to the dielectric constant, with the coefficient of determination, R2, being 0.74. These results suggest that the dielectric constant as determined by GPR testing can be used to improve the construction quality and maintenance of asphalt pavements.
        4,000원
        47.
        2016.06 구독 인증기관·개인회원 무료
        최근 아시아 개도국은 경제 활성화에 따른 도로 건설 시장의 확대, 간선도로 및 국도망의 효율적・과학 적 도로 관리를 위한 정책과 전략을 수립하고 있다. 이에 국가발전 인프라 시설 확대, 도로 포장 개선, 관 리 체계 구축과 관련된 많은 연구를 수행하고 있다. 이러한 시대적 흐름에 맞추어 이번 연구를 통하여 도 로 포장 조사 장비 개발, 최적 유지보수 공법 선정을 위한 포장 파손 분석 프로그램 개발로 글로벌 경쟁력 강화와 적정 기술 현장 적용 기회를 마련하고자 하였다. 현재 개발도상국(필리핀, 베트남 등)은 경제 활성화로 인한 교통 인프라를 확충하고 교통 체증을 해소하 고자 기반 시설인 도로 건설 및 교통시스템에 많은 예산을 투자하고 있다. 필리핀의 경우 ROCOND(Road Condition Assessment) 사업을 위한 도로 포장 조사의 자동화를 추진하고자 하며, 자동화 조사와 기존 육 안조사와의 차이점을 분석하고, 조사 자료를 검증 및 보완하기 위한 시범 사업을 올해부터 추진하는 것으 로 파악되었다. 아시아 개도국 맞춤형 도로포장관리 기술을 적용하기 위해 현지 도로 및 경제, 기후 환경 을 고려한 도로 포장 파손 평가 프로그램을 개발하고, 도입 기반을 마련하였다. 또한 필리핀과 베트남의 노동 집약적 도로 포장관리시스템 체계를 자동화로 전환하여 보다 객관적이며 정확한 도로 유지관리 체계 를 구축하는데 기여하고자 하였다. 본 연구에서 개발된 프로그램은 기존의 도로 포장 파손 평가 프로그램 을 검증하여 개도국 실정에 맞게 수정・보완하였다. 세부적으로는 필리핀 현지 국도 유지 관리 및 기능 향 상을 위해 기존 포장관리시스템 조사 자료를 이용하여 개선된 포장 평가 기준과 방법을 수립하고, 향후 개 도국 뿐 아니라 유럽 및 선진국과의 교류 협력을 통해 대한민국의 포장관리시스템 및 포장 파손 평가 프로 그램의 기술을 홍보, 전파하고, 해외 도로 유지관리 시장에 진출 하고자 한다.
        48.
        2016.06 구독 인증기관·개인회원 무료
        최근 대도시에서 빈번하게 발생하는 도로함몰로 인해 국민들의 불안감이 증대되는 가운데 도로함몰 발 생 원인 및 위험도 평가를 위한 기초연구가 필요한 실정이다. 이를 위해 한국건설기술연구원에서 보유한 포장가속시험기(Accelerated Pavement Tester, APT) 운영을 통해 동공 심도 및 크기에 따라 아스팔트 포장체 파손에 미치는 영향을 파악하고자 한다. 먼저 예비실험 및 동공 관련 문헌조사 결과 동공 생성에 얼음이 적합한 것으로 판단되어 테스트베드 구축 시 가로×세로×높이가 50cm×50cm×30cm인 얼음을 주문 제작하여 포장가속시험기 바퀴축의 중앙에 깊이 0.3m와 0.7m 지점에 매설하였다. 동공 매설 깊이 와 크기를 결정한 기준은 일본의 도로함몰 위험도 등급 기준과 서울시에서 발생된 동공의 심도 중 그 빈 도가 높은 위치를 선정하였다. 동공 매설 시 내시경 촬영을 위한 관을 매립하여 동공 생성 여부 및 함몰 진행상황을 모니터링 하였다. 테스트베드 구축한 후 FWD 장비를 이용하여 동공을 매설한 동공구간과 매설하지 않은 건전구간의 구 조적 지지력을 측정하였으며, 동공구간이 건전구간보다 처짐값이 약 10% 정도 낮은 것으로 파악되었다. 1차 포장가속시험 후(운행횟수 90,000회) 소성변형량 측정 결과 건전구간은 약 10mm 정도의 소성변형이 발생했으나 동공구간은 약 30mm정도 발생하여 약 3배의 차이가 나는 것으로 파악되었다.
        49.
        2016.06 구독 인증기관·개인회원 무료
        본 연구에서는 평택 미8군 차량정비시설 내 콘크리트 포장의 줄눈부 하중전달효율(Load Transfer Efficiency, LTE)을 평가하기 위해 FWD(Falling Weight Deflectometer)를 이용한 조사・평가를 수행하 였다. 본 연구에서는 <그림 1>에서와 같이 FHWA/TX-07/0-5123-2“Guidelines for Evaluation of Existing Pavement for HMA Overlay”에서 제시한 FWD 처짐 하중전달효율 산정식을 사용하였다. FWD를 이용한 콘크리트 슬래브 줄눈부의 하중전달효율을 조사한 결과는 <표 1>에서 보는 바와 같다. 하중전달효율이 80% 이상인 지점은 97개소로 전체의 약 84.3%에 해당한다. 콘크리트 슬래브 시공 당시 줄눈부에 <그림 2>와 같은 배부름현상(Bulging)이 발생하였다. 배부름현상 이 하중전달효율에 미치는 영향을 파악하기 위하여 총 24개 줄눈부에 대하여 순방향과 역방향으로 <그림 2>와 같이 FWD 시험을 수행하였다. <그림 3>은 각 줄눈부에서 Case 1과 Case 2의 하중전달효율을 비교 한 것이다. 그래프에서 보는 바와 같이 LTE 차이가 ±2% 이내인 경우를 (6개 지점) 제외하고 총 18개 줄 눈부 중 15개 줄눈부에서 Case 1이 Case 2보다 LTE가 큰 것으로 나타나 줄눈부 배부름현상이 LTE에 영 향을 주는 것으로 나타났다.
        50.
        2016.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : The applicability of the mechanics-based similarity concept (suggested by Feng et al.) for determining scaled variables, including length and load, via laboratory-scale tests and discrete element analysis, was evaluated. METHODS: Several studies on the similarity concept were reviewed. The exact scaling approach, a similarity concept described by Feng, was applied in order to determine an analytical solution of a free-falling ball. This solution can be considered one of the simplest conditions for discrete element analysis. RESULTS : The results revealed that 1) the exact scaling approach can be used to determine the scale of variables in laboratory tests and numerical analysis, 2) applying only a scale factor, via the exact scaling approach, is inadequate for the error-free replacement of small particles by large ones during discrete element analysis, 3) the level of continuity of flowable materials such as SCC and cement mortar seems to be an important criterion for evaluating the applicability of the similarity concept, and 4) additional conditions, such as the kinetics of particle, contact model, and geometry, must be taken into consideration to achieve the maximum radius of replacement particles during discrete element analysis. CONCLUSIONS : The concept of similarity is a convenient tool to evaluate the correspondence of scaled laboratory test or numerical analysis to physical condition. However, to achieve excellent correspondence, additional factors, such as the kinetics of particles, contact model, and geometry, must be taken into consideration.
        4,000원
        51.
        2016.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : The objective of this study is to determine the optimal frequency of ground penetrating radar (GPR) testing for detecting the voids under the pavement. METHODS : In order to determine the optimal frequency of GPR testing for void detection, a full-scale test section was constructed to simulate the actual size of voids under the pavement. Voids of various sizes were created by inserting styrofoam at varying depths under the pavement. Subsequently, 250-, 500-, and 800-MHz ground-coupled GPR testing was conducted in the test section and the resulting GPR signals were recorded. The change in the amplitude of these signals was evaluated by varying the GPR frequency, void size, and void depth. The optimum frequency was determined from the amplitude of the signals. RESULTS: The capacity of GPR to detect voids under the pavement was evaluated by using three different ground-coupled GPR frequencies. In the case of the B-scan GPR data, a parabolic shape occurred in the vicinity of the voids. The maximum GPR amplitude in the A-scan data was used to quantitatively determine the void-detection capacity. CONCLUSIONS: The 250-MHz GPR testing enabled the detection of 10 out of 12 simulated voids, whereas the 500-MHz testing allowed the detection of only five. Furthermore, the amplitude of GPR detection associated with 250-MHz testing is significantly higher than that of 500-MHz testing. This indicates that 250-MHz GPR testing is well-suited for the detection of voids located at depths ranging from 0.5~2.0 m. Testing at frequencies lower than 250 MHz is recommended for void detection at depths greater than 2 m.
        4,000원
        53.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : The objective of this study is to propose a quality control and quality assurance method for use during asphalt pavement construction using non-destructive methods, such as ground penetrating radar (GPR) and an infrared (IR) camera. METHODS: A 1.0 GHz air-coupled GPR system was used to measure the thickness and in situ density of asphalt concrete overlay during the placement and compaction of the asphalt layer in two test construction sections. The in situ density of the asphalt layer was estimated based on the dielectric constant of the asphalt concrete, which was measured as the ratio of the amplitude of the surface reflection of the asphalt mat to that of a metal plate. In addition, an IR camera was used to monitor the surface temperature of the asphalt mat to ensure its uniformity, for both conventional asphalt concrete and fiber-reinforced asphalt (FRA) concrete. RESULTS: From the GPR test, the measured in situ air void of the asphalt concrete overlay gradually decreased from 12.6% at placement to 8.1% after five roller passes for conventional asphalt concrete, and from 10.7% to 5.9% for the FRA concrete. The thickness of the asphalt concrete overlay was reduced from 7.0 cm to 6.0 cm for the conventional material, and from 9.2 cm to 6.4 cm for the FRA concrete. From the IR camera measurements, the temperature differences in the asphalt mat ranged from 10℃ to 30 ℃ in the two test sections. CONCLUSIONS: During asphalt concrete construction, GPR and IR tests can be applicable for monitoring the changes in in situ density, thickness, and temperature differences of the overlay, which are the most important factors for quality control. For easier and more reliable quality control of asphalt overlay construction, it is better to use the thickness measurement from the GPR.
        4,000원
        54.
        2015.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES: The objective of this study is to analyze the relationship between the FWD back-calculated modulus and dynamic modulus of asphalt layers for existing asphalt pavements. METHODS: To evaluate the dynamic modulus of the asphalt mixture in the existing and new asphalt layers, the uniaxial direct tension test was conducted on small asphalt specimens obtained from the existing asphalt-covered pavements. A dynamic modulus master curve was estimated by using the uniaxial direct tension test for each asphalt layer. The falling weight deflectometer (FWD) testing was conducted on the test sections, and the modulus values of pavement layers were back-calculated using the genetic algorithm and the finite element method based back-calculation program. The relationship between measured and back-calculated asphalt layer moduli was examined in this study. The normalized dynamic modulus was adopted to predict the stiffness characteristics of asphalt layers more accurately. RESULTS: From this study, we can conclude that there is no close relationship between dynamic modulus of first layer and back-calculated asphalt modulus. The dynamic moduli of second and third asphalt layers have some relation with asphalt stiffness. Test results also showed that the normalized dynamic modulus of the asphalt mixture is closely related to the FWD back-calculated modulus with 0.73 of R square value. CONCLUSIONS: The back-calculated modulus of asphalt layer can be used as an indicator of the stiffness characteristics of asphalt layers in the asphalt-covered pavements.
        4,000원
        55.
        2015.10 구독 인증기관·개인회원 무료
        최근 대한민국 국민들에게 인명, 재산 피해는 물론 불안감을 야기시키는 도로함몰이 사회적으로 큰 이 슈가 되고 있다. 최근 5년간 대한민국의 수도 서울에서 발생한 도로침하, 동공발생, 도로함몰 건수는 총 3,328건이며, 점점 증가하는 추세인 것으로 나타났다. 이러한 도로함몰의 원인은 포장하부에 발생한 동 공의 크기가 커짐에 따라 노상의 지지력이 포장 상부의 하중을 견디지 못해 발생하는 것이며, 이를 예방 하기 위해 사전에 의심구간을 탐사하고 대책을 마련해야 한다. 따라서, 국토교통부에서는 각 지자체에 동 공이 의심되는 구간을 접수 받아 한국건설기술연구원에 협조 요청하여 지표투과탐사장비(GPR)를 이용해 현장조사 하였고, 동공이 탐지되는 구간은 즉시 보수하기로 협의하였다. 지표투과 탐사장비 중 가장 널리 사용되는 GPR(Ground Penetrating Radar)은 대상체에 전자기파를 발 사하여 재료의 성질이 바뀌는 경계면에서 파의 에너지 일부가 반사되고 나머지는 통과하는 특성을 이용한 장 비다. 또한 포장 하부의 상태를 비파괴적이고, 연속적으로 파악할 수 있는 장점을 가지고 있다. 이러한 GPR 을 이용한 탐사는 주파수에 따라 그 특성이 달라지며, 김대상 외(2004)는 조사심도 0m 에서 1.5m 이내에서 는 500MHz~1,600MHz의 안테나가 가장 적합하다고 보고하였다. 본 조사는 대한민국 전국 일반국도 10개 노선의 총 19개 지점에서 진행하였고, 포장하부 동공 의심구간에 한국건설기술연구원에서 보유한 500MHz와 1,600MHz의 레이더를 탑재한 GPR 장비로 그림 1과 같이 계측을 수행하였다. 그림 2와 같이 동공이 의심되 는 구간을 파악하여 주파수 별 결과 값을 비교하고, 포장하부 동공탐사에 적합한 주파수 영역을 제시하였다. 향후 본 연구원에서 제작한 실대형 모의동공 Test Bed에서 본 조사에서 획득한 결과를 검증할 예정이다.
        56.
        2015.10 구독 인증기관·개인회원 무료
        안테나 기술 및 데이터 처리 기술의 발전으로 인하여 비파괴 시험 장비인 GPR(Ground Penetration Radar; 지표투과탐사장비) 장비의 적용이 확대되고 있다. GPR 장비는 송신기에서 지표면으로 전자기파 를 송출하고, 송출된 전자기파가 매질의 유전율에 따라 수신기로 반사되거나 회절 또는 산란되어 돌아오 는 시간 영역에서의 특성에 기초하여 지표 하부의 층구조 및 매설물을 조사할 수 있는 장비이다. 이러한 GPR 장비는 현재 포장층 두께조사, 지하 동공 및 지질조사, 터널 라이닝 및 구조조사 등 여러 분야에서 적용되고 있다. 외국에서는 GPR 장비의 적용분야 가운데 도로포장분야에서 GPR 장비를 포장층 두께 측정, 박리의 위 치조사, 포장층 밀도예측, 다우웰바 탐지 등에 적용할 수 있다고 알려져 있으나 아직 많이 활성화되어 있 지는 않은 상황이다. 국내에서는 일반국도 도로포장관리시스템(Pavement Management System; PMS) 에서 주로 포장층 두께 측정을 위해 GPR 장비를 활용하면서 그 적용범위를 확대하고자 노력하고 있으며, 500MHz 주파수의 접촉식 GPR 장비와 1.0GHz 주파수의 비접촉식 GPR 장비가 사용되고 있다. 최근 사회적으로 이슈화되고 있는 도로함몰 예방을 위한 동공 조사에 현재 도로포장분야에서 활용중인 GPR 장비를 적용하기 위해서는 먼저 각 주파수별 측정 깊이의 파악이 필요하다. 왜냐하면 측정 주파수가 높으면 해상도는 좋아지지만 전자기파의 측정 깊이가 작아지고, 측정 주파수가 낮으면 해상도는 낮아지지 만 전자기파의 측정 깊이가 커지기 때문이다. 따라서 주파수별로 어느 정도 깊이까지 전자기파가 침투할 수 있는지, 측정된 데이터의 해상도가 어떻게 나타나는지 확인하여 사용목적에 적합하게 사용할 필요가 있다. 본 연구에서는 포장표면에서부터 깊이별로 스티로폼으로 모사한 동공을 설치하고 250MHz, 500MHz, 800MHz 주파수의 접촉식 GPR 장비와 1.0GHz 주파수의 비접촉식 GPR 장비를 사용하여 동일한 구간을 측정한 후, 각각의 B-scan 결과를 비교하였다. 그 결과, 포장층 두께 정도의 깊이를 조사하기 위해서는 1.0GHz 주파수의 비접촉식 안테나를 사용하는 것이 가능하지만, 1.5m 깊이 부근까지의 동공 여부를 조 사하기 위해서는 500MHz 주파수 정도의 접촉식 안테나를 사용해야 하는 것으로 나타났다.
        57.
        2015.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES: This study investigates the mechanical performance of carbon-capturing concrete that mainly contains blast furnace slag. METHODS: The mixture variables were considered; these included Portland cement content, which was varied from 10% to 40% of the blast furnace slag by weight. The specimens were exposed to different conditions such as high N2 and O2 concentrations, laboratory conditions and high CO2 conditions. Mechanical performances, including compressive and flexural strengths and carbon-capturing depth, were evaluated. RESULTS : The slump, air content and unit weight were not affected significantly by the variation in cement content. The strength development when the specimens were exposed to high purity air was slightly greater than that when exposed to high CO2. As the cement content increased the compressive and flexural strength increased but not considerably. The carbon-capturing capacity decreased as the cement content increased. The specimens exposed in the field for 70 days had flexural strength greater than 3 MPa. CONCLUSIONS : The results indicate that cement content is not an important parameter in the development of compressive and flexural strengths. However, the carbon-capturing depth was higher for less cement content. Even after field exposure for 70 days, neither any significant damage on the surface nor any decrease in strength was observed.
        4,200원
        58.
        2015.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES: In this study, alkali-activated blast-furnace slag (AABFS) was investigated to determine its capacity to absorb carbon dioxide and to demonstrate the feasibility of its use as an alternative to ordinary Portland cement (OPC). In addition, this study was performed to evaluate the influence of the alkali-activator concentration on the absorption capacity and physicochemical characteristics. METHODS: To determine the characteristics of the AABFS as a function of the activator concentration, blast-furnace slag was activated by using calcium hydroxide at mass ratios ranging from 6 to 24%. The AABFS pastes were used to evaluate the carbon dioxide absorption capacity and rate, while the OPC paste was tested under the same conditions for comparison. The changes in the surface morphology and chemical composition before and after the carbon dioxide absorption were analyzed by using SEM and XRF. RESULTS: At an activator concentration of 24%, the AABFS absorbed approximately 42g of carbon dioxide per mass of paste. Meanwhile, the amount of carbon dioxide absorbed onto the OPC was minimal at the same activator concentration, indicating that the AABFS actively absorbed carbon dioxide as a result of the carbonation reaction on its surface. However, the carbon dioxide absorption capacity and rate decreased as the activator concentration increased, because a high concentration of the activator promoted a hydration reaction and formed a dense internal structure, which was confirmed by SEM analysis. The results of the XRF analyses showed that the CaO ratio increased after the carbon dioxide absorption. CONCLUSIONS : The experimental results confirmed that the AABFS was capable of absorbing large amounts of carbon dioxide, suggesting that it can be used as a dry absorbent for carbon capture and sequestration and as a feasible alternative to OPC. In the formation of AABFS, the activator concentration affected the hydration reaction and changed the surface and internal structure, resulting in changes to the carbon dioxide absorption capacity and rate. Accordingly, the activator ratio should be carefully selected to enhance not only the carbon capture capacity but also the physicochemical characteristics of the geopolymer.
        4,000원
        59.
        2014.09 구독 인증기관·개인회원 무료
        최근 도로포장 건설은 신설보다는 현재 공용중인 도로포장을 확장하거나 유지보수를 하는 추세이다. 이에 따라 유지보수공법을 적용한 도로포장체에 대한 정확한 지지력 및 공용성 평가가 향후 도로포장의 수명 예측 및 유지보수공법 적용에 매우 중요한 요소가 되고 있다. 본 논문의 목적은 주기적인 유지보수 에 따른 도로포장의 층별 구조적 지지력을 정확하게 평가하기 위한 소형시편 동탄성계수 시험결과와 FWD 비파괴 시험 결과와의 상관관계를 규명하고자 한다. 현장 아스팔트 혼합물의 역학적 물성을 측정하기 위하여 소형시편을 이용한 일축직접인장 시험법을 이 용하여 아스팔트 층별 동탄성계수를 측정하였다. 노스캐롤라이나 주의 6개구간에서 구간별 3~5개 층, 2 개 지점에서 코어하여 소형시편을 채취하였다<그림 1>. 채취한 시편들은 5, 20, 40도에서 25, 10, 5, 1, 0.5, 0.1 Hz 하중조건에서 동탄성계수 시험을 수행하여 동탄성계수 마스터커브를 결정하였다. 본 연구에서는 도로포장층 탄성계수를 역산하기 위하여 유한요소 해석 아스팔트 포장 구조해석 프로그 램을 엔진으로 유전자 알고리즘을 활용한 역산 프로그램을 이용하였다. 본 프로그램은 한국건설기술연구 원에서 개발된 프로그램으로 노스캐롤라이나의 현장 및 실내시험 결과에 적용하였다. 도로포장층 FWD 역산 탄성계수는 아스팔트층의 경우, 탄성계수 범위가 1.5~6GPa이며, 보조기층 탄성계수 범위는 150~850MPa이며 노상층 탄성계수 범위는 60~400MPa이다. 도로포장체의 구조적 지지력은 아스팔트층 의 탄성계수와 두께에 의하여 결정된다. 실내시험을 통하여 결정된 동탄성계수에 두께를 곱한 후 합산한 값을 전체 아스팔트층 두께로 나눈 탄성계수 (Normalized Dynamic Modulus) 산정한 후 FWD 역산탄성 계수와 비교하였다. 본 탄성계수를 사용할 경우 도로포장의 두께의 영향을 고려할 수 있으며 두께가 지지 력 산정에 반영될 수 있다. <그림 2>에 나타난 바와 같이 역산과 실측 탄성계수간의 R square값이 0.73 으로 상관도가 매우 높음을 알 수 있다. 향후에는 FWD 하중 적용시 발생하는 아스팔트 각 층의 주파수 를 산정하여 주파수별 동탄성계수와 FWD 역산 탄성계수간의 상관관계를 검토하고자 한다.
        60.
        2014.09 구독 인증기관·개인회원 무료
        공용중인 도로 상태를 조사 및 평가하기 위하여 다양한 종류의 비파괴시험 장비가 활용되고 있다. 이 중 에서 충격하중에 의한 표면처짐량을 측정하는 FWD(Falling Weight Deflectometer)는 포장 하부의 지지 력 평가를 위하여 널리 사용되고 있다. 하지만 표면처짐 또는 지지력만으로 복잡한 포장 하부의 상태를 정 확하게 평가하기에는 한계가 있다. 특히 최근 들어 사회적으로 큰 이슈가 되고 있는 도로함몰(일명 싱크 홀)은 일반적으로 도로하부에 발생한 공동으로 인하여 상부 포장층이 연쇄적으로 함몰되는 현상이다. 도로 함몰은 전조현상 없이 갑작스럽게 발생되기 때문에 이를 사전에 발견하기는 어려운 실정이다. 따라서 이를 사전에 예방하고, 발생 후 올바른 보수를 하기 위해서는 도로 하부에 존재할 수 있는 공동 여부를 비롯한 도로 하부 상태에 대한 철저한 조사가 우선되어야 한다. 석회암지대 또는 광산지대에서 주로 발생하는 대 규모의 싱크홀의 경우 전기비저항, 단층촬영 등과 같은 조사를 통하여 공동에 대한 조사가 가능하다. 하지 만 도로의 경우 조사 연장이 길고 교통통제가 어렵기 때문에 정적인 시험 보다는 이동하면서 조사할 수행 할 수 있는 지표투과레이더(Ground Penetrating Radar, GPR)가 보다 현실적으로 가능성이 높다. 본 연구에서는 두 가지 종류의 GPR을 이용하여 도로함몰이 발생한 현장에 대한 도로 하부 조사 결과를 비교 평가하였다. 조사에는 500MHz 접촉식 GPR과 1000MHz 비접촉식 GPR이 각각 사용되었다. GPR 조사는 도로함몰이 발생된 후 응급보수로 되메움 공사가 완료된 후에 추가적인 공동 여부를 확인하기 위 하여 실시하였다. 그림 1은 1000MHz 비접촉식 GPR 시험 장비와 조사 결과를 나타낸다. 도로함몰이 발 생한 구간의 경우 40~50cm 깊이까지 단면 교란이 발생하였나, 되메움 구간에 추가 공동이 발견되지는 않아 시공은 양호하게 이루어진 것으로 나타났다. 함몰 주변 도로 하부의 경우 60~70cm 깊이에서 체류 수가 존재하는 것으로 나타났다. 본 구간의 경우 도로 하부에 매설된 하수관이 일부 막히고 노후화로 인 한 파손으로 누수가 발생하여 세립분이 빠져나가 공동이 발생된 것으로 추정되었다. GPR 조사 결과 주변 에 추가적인 공동 또는 도로함몰 위험은 없는 것으로 나타났다. 따라서 되메움 후 덧씌우기를 실시하고, 주기적인 현장 점검을 통하여 추가적인 함몰 발생 조짐을 감시하는 것이 바람직하다고 판단된다.
        1 2 3 4 5