검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 385

        202.
        2009.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Estimation of mortality behavior of a industrial property are useful for calculating depreciation and making management decisions relating to property. The common methods of computing depreciation require an estimation of service life, and some methods ma
        4,000원
        203.
        2009.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper considers a multiagent scheduling problem under public information where a machine is shared by multiple agents. Each agent has a local objective among the minimization of total completion time and the minimization of maximum. In this problem.
        4,000원
        212.
        2008.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The small break loss-of-coolant accidents for the HANARO fuel test loop have been predicted by MARS code. Conservative method was used for the prediction of the loss-of-coolant accidents. The maximum peak cladding temperature was calculated as 1286K, which was lower than the design limit temperature (1477K) of nuclear fuels for the HANARO fuel test loop. The maximum peak cladding temperature occurred for the cold leg break in the HANARO pool. The hydrogen generation and oxidation of the fuel cladding were also negligible. Consequently, it is ensured that the emergency cooling water system for the HANARO fuel test loop is appropriate for the small break loss-of-coolant accidents.
        4,000원
        216.
        2008.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 국제적으로 지진 발생 규모가 증대하고 있는 가운데 우리나라에서도 자연대책법상 법적인 기준 내용이 강화되어 전기통신기본법에 따른 통신시설이 지난 2007년 1월 내진설계 대상 범주로 추가되었으며 이에 따라 세부 규격기준 내용 수립을 위한 연구가 추진되고 있다. 본 논문은 통신설비에 적용하여야 할 구체적 규격기준 내용의 수립 방안에 대하여 다룬 것이다. 이를 위하여 법률 고시에 따른 내진설계 대상 통신설비 부류를 소개하고 국내에 있어서 현재까지 연구되어 활용할 수 있는 기반 기술규격으로서의 건축법령상 건축구조설계기준의 설계 절차에 대하여 알아본다. 그리고 제외국 유수 규격 내용의 활용 도입 방안을 검토하였다. 이러한 기존 기술규격들을 바탕으로 실제로 법적 기준상에 도입하여야 할 통신설비 내진설계 적용 방안을 제시한다.
        4,000원
        217.
        2008.04 구독 인증기관 무료, 개인회원 유료
        This study's purpose centers plant management activities that is management system for total plant efficiency's maximization, plant evaluation system that production and safety management activities factor that is enforcing in manufacturing industry can develop evaluation model that can evaluate quantitative activities in process that maximize productivity and safety efficiency wishes to do design.
        4,000원
        218.
        2008.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study's purpose centers plant management activities that is management system for total plant efficiency's maximization, plant evaluation system that production and safety management activities factor that is enforcing in manufacturing industry can develop evaluation model that can evaluate quantitative activities in process that maximize productivity and safety efficiency wishes to do design.
        4,000원
        219.
        2007.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
          The estimation of mortality characteristics of industrial property is an important adjunct to engineering valuation and depreciation estimation. Once the important of depreciation estimation is determined, it is desirable to understand the processes upo
        4,000원
        220.
        2007.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        FTL(Fuel Test Loop) is a facility that confirms performance of nuclear fuel at a similar irradiation condition with that of nuclear power plant. FTL construction work began on August, 2006 and ended on March, 2007. During Construction, ensuring the worker's safety was the top priority and installation of the FTL without hampering the integrity of the HANARO was the next one. The installation works were done successfully overcoming the difficulties such as on the limited space, on the radiation hazard inside the reactor pool, and finally on the shortening of the shut down period of the HANARO. The Commissioning of the FTL is on due to check the function and the performance of the equipment and the overall system as well. The FTL shall start operation with high burn up test fuels in early 2008 if the commissioning and licensing progress on schedule.
        4,000원