검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 76

        21.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper has proposed a reinforcing method for damaged RC columns with SRF sheets and Aramid rods. In order to verify the effectiveness and performance, two original columns and two reinforced columns with SRF sheets and Aramid rods were developed and tested under lateral cyclic displacement and a constant axial load. The test showed that the improvement of energy dissipation capacity was increased in terms of strength and ductility. In addition, an analytical modeling of the standard specimens was proposed using Response-2000 and ZeusNL program. The results of analytical and experimental studies for two standard columns were compared in terms of loading-displacement curve and energy dissipation capacity based on the nonlinear static analysis.
        4,000원
        22.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, Nonlinear Static Pushover analysis method(NSP) is proposed which apply to RC buildings reinforced by external retrofit fornseismic performance. Based on previous analysis and research, NSP is more developed by connection nonlinearity according to shearnresistance mechanism such as dowel and adhesive resistance as major shear resistance elements. According to the proposed method,nstructural analysis for example buildings was carried out to evaluate seismic performance of buildings. And, it was confirmed thatndepending on shear strain and characteristics of joint resistant of external retrofitting are different from internal retrofitting. Furthermore,nthe strength reduction coefficient of the anchor needs to be considered at the joint design.
        4,300원
        27.
        2008.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        심층혼합처리공법에서 원지반과 개량재에 의해 형성되는 혼합처리토에 산업폐기물중 하나인 폐타이어와 기존 토목공사에서 섬유보강재로 사용되고 있는 강섬유를 혼합하여 보강재 및 개량재의 혼합비에 따른 개량체의 압축강도 특성을 파악하기위해 실내실험을 실시하였다. 개량재(시멘트, 시멘트계 고화재)의 경우는 건토중량에 대한 혼합비를 5%, 10%, 15%로 하였으며, 보강재(폐타이어, 강섬유)의 경우는 건토중량에 대한 혼합비를 0.5%, 1%, 2%로 하였다. 그 결과 개량재의 혼합비가 증가함에 따라 일축압축강도는 증가하였으며, 보강재를 첨가한 경우에는 폐타이어분말의 입자크기와 강섬유의 형상비가 작을수록 강도가 크게 나타났으며, 첨가량이 많아질수록 강도가 저하되는 경향이 나타났다.
        4,000원
        28.
        2019.10 서비스 종료(열람 제한)
        구조물의 내진보강의 필요성이 대두되고 있지만 이를 담당하는 기관이나 사람은 내진구조 비전공자로 효과적으로 내진보강사업을 발주 및 관리, 감독하는데 어려움이 있다. 이러한 문제점을 해결하기위해 분석적 계층화 프로세스를 이용하여 보강대상 건축물의 내진보강공법 우선순위를 제안하는 프로그램을 개발하였다. 이를 통해 담당자는 구조물별, 내진성능 부족요인 별 최적의 내진보강공법을 선정할 수 있을 것으로 기대된다.
        29.
        2019.04 서비스 종료(열람 제한)
        In this paper, a shear behavior of RC beam strengthened by basalt FRCM was investigated. The presence of strengthened with Basalt FRCM was considered as an experimental variable. The experimental result show that the maximum load of beam strengthened by basalt FRCM was increased 75.4% compared with that of non-strengthened beam.
        30.
        2019.04 서비스 종료(열람 제한)
        This paper examined the flexural behavior of section enlargement strengthening columns with prefabricated reinforcement units in the jacket section. The developed strengthening column was particularly effective in enhancing the ductility of the columns.
        33.
        2018.04 서비스 종료(열람 제한)
        In this study, the fatigue behavior of reinforced concrete beams strengthened with prestressed NSM CFRP tendons. One of test objectives is to find out strengthening effect with concrete strength 20MPa, 40MPa. As a result of the study, the fatigue behavior of the concrete beams strengthened with prestressed NSM CFRP tendons were considered to be good.
        34.
        2018.04 서비스 종료(열람 제한)
        This paper analyzed design bearing capacities of pile foundations strengthened by pre-loading method for vertical expansion. The bearing capacities were investigated for two different pre-loading strategies: (1) after partial removals of structural/non-structural elements (e.g. finish, masonry wall etc.); and (2) after vertical expansions. Based on the numerical studies, more than 60% of the existing piles exceeded the design bearing capacities due to the difference of pre-loading strategies, which should be considered in structural design.
        35.
        2018.03 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 TS 내진보강공법의 내진보강 효과 검증을 목적으로 7개의 지진파에 대한 TS 댐퍼(Tension Spring-Damper)로 내진보강된 구조물의 비선형 시간이력해석을 수행하였다. 비선형 시간이력 해석을 통해 얻어진 무보강 구조물의 층간변위비와 에너지소산 양과 비교한 결과 층간변위비가 약 30% 가량 감소하였고, 구조체를 통한 에너지 소산의 양은 반감되었다. 이를 통해 TS 내진보강공법의 제진성능이 우수함을 확인하였다.
        36.
        2018.03 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 TS 내진보강공법의 내진보강 효과를 검증 할 목적으로 TS 댐퍼(Tension Spring-Damper)를 설치한 철근콘크리트 골조를 대상으로 한 반복 주기하중 재하 실험을 수행 하였다. 실험체는 기준 실험체인 무보강 골조 실험체와 3개의 보강 골조 실험체의 총 4개이며, 실험의 변수는 댐퍼 설치 여부, 댐퍼의 형상 및 시공방법이다. 그 결과 창호 내부 삽입 형식의 시공방법이 강도와 강성의 측면에서 2배가량, 외부 부착형식의 시공 방법이 에너지 소산의 측면에서 2배가량의 성능 향상을 나타내어 TS 내진보강공법이 현장 적용성과 내진보강 효과가 우수한 공법임을 확인 할 수 있었다.
        37.
        2017.05 KCI 등재 서비스 종료(열람 제한)
        1980년대에서 1990년대 중반까지 건설된 노후 공동주택 단지의 주차장 부족 현상은 심각하다. 노후 공동주택의 주차장 확대 사례 를 살펴보면 수직으로 지하 주차장을 확장하는 방식이 대부분을 차지하고 있다. 기존 건축물을 증축할 경우 기초의 구조적 안전성 확보는 매우 중요하며, 지하 수직방향 공사의 경우 작업 공간이 협소하기 때문에 안전성, 환경성 및 시공성이 우수한 공법을 적용해야 한다. 도심지 공사는 소음과 진동이 작은 공법과 장비의 사용도 필수적이다. 이 연구는 지하주차장 확대 공사에 필요한 기초보강 공법 선정에 영향을 미치는 요인을 분석하고 영향요인의 가중치를 산정하여 기초보강공법의 적용성을 분석 할 목적으로 수행되었다. 기초보강 공법의 적용성에 영향을 미치는 요인은 전문가 면담조사를 통하여 도출하였고, AHP기법을 통하여 영향요인의 가중치를 산정하였다. 전문가를 대상으로 기초보강 공법의 적 용성을 평가 하였다. 2건의 지하주차장 확대 유형에 대한 사례연구를 실시하여 기초보강공법의 적용성을 비교 분석하였다.
        39.
        2016.10 서비스 종료(열람 제한)
        This is A Study on the Bond Performance of Synthetic Polymer Composite Waterproofing and Anticorrosion Method in accordance with PE Fiber Reinforcement. Test results, A Bond Performance of the Test Specimen was confirmed to have increased 37.5%. By PE Fiber Reinforcement.
        1 2 3 4