검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 154

        41.
        2014.07 구독 인증기관·개인회원 무료
        Explicit environmental attitude measures tend to produce strong socially desirable responses (Bruni & Schultz, 2010; Milfont & Duckitt, 2010; Stern & Dietz, 1994) and fail to capture more than what participants consciously recall (e.g., explicit belief, past behavior, Dunlap, Van Liere, Mertig, Jones, 2000; Schultz, Shriver, Tabanico, & Khazian, 2004). A number of studies have highlighted the popularity of environmental issues in common discourse in various countries, which leads individuals to eagerly express pro-environmental explicit attitudes (Dunlap, 1998; Leiserowitz, 2005; Meijers & Stapel, 2011). Therefore, an explicit measure of environmental attitudes would hardly be an unbiased indicator of prior knowledge and experience when testing the effect of subtle feeling on judgments: although a participant explicitly reports favorable attitudes toward environment or related issues, it does not necessarily mean that she or he has knowledge and experience to hinder the regulatory fit effects. Using the Implicit Association Test, we examined whether the extent to which individuals are implicitly biased toward (or against) sustainability moderates the regulatory focus by construal level interaction. Scores from the indirect measure of attitudes served as the indicator of the strength of associations between the concept of sustainability and evaluations that may result form its frequent pairing with desirable consumption patterns or repeated exposure to persuasive messages promoting sustainability. Specifically, we showed that the regulatory focus – construal level fit effect will be greater among individuals who have not formed significant associations about sustainability since these individuals are more likely to rely on feeling right from regulatory fit rather than using prior experience or knowledge.
        42.
        2014.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The friction damper can be used for improving the seismic resistance of existing buildings. The damper is often installed in bracing members. The energy dissipation capacity of the damping systems depends on the type of the structure, the configuration of the bracing members, and the property of dampers. In Korea, there are numerous low- to mid-rise reinforced concrete moment frames that were constructed considering only gravity loads. Those frames may be vulnerable for future earthquakes. To resolve the problem, this study developed a toggle bracing system with a high density friction damper. To investigate the improvement of reinforced concrete frames after retrofit using the developed damped system, experimental tests were conducted on frame specimens with and without the damped system. The results showed that the maximum strength, initial stiffness and energy dissipation capacity of the framed with the damped system were much larger than those of the frame without the damped system.
        4,000원
        43.
        2014.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper is the sequel of a companion paper (I. Performance Evaluation) evaluating the relation between the seismic performance of steel intermediate moment frames (IMFs) and the rotation capacity of connections. The evaluation revealed that the seismic performance of IMFs having the required minimum rotation capacity suggested in the current standards did not meet the seismic performance criteria presented in FEMA 695. Therefore, thepresent study evaluates the causes of the vulnerable seismic performance for steel IMFs and proposes alternatives to satisfy the seismic performance suggested in FEMA 695. To that goal, the results of nonlinear analysis, which are the pushover analysis and the incremental dynamic analysis, are examined and evaluated. As a result, high-rise IMF systems are seen to have the lower collapse margin ratio after connection fracture than row-rise IMF systems and, the actual response isfound to compared tothedesign drift ratio acting on design load design. Finally, the minimum design load values are proposed to meet the seismic performance suggested in FEMA 695 for IMF systems having vulnerable seismic performance.
        4,200원
        44.
        2014.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The current AISC341-10 standard specifiesa value of 0.02 radian for the minimum rotation capacity of connections for the intermediate steel moment frame system. However, despite of the advances realized in the domains of performance evaluation method and analysis method, research onthe minimum rotation capacity of the intermediate steel moment frame systemsatisfying the seismic performance has not been conducted in detail. In this study, the intermediate moment frame systemisdesigned with respect to current standards and the seismic performance in accordance with the rotational capacity of connections is evaluated using the seismic performance evaluation method presented in FEMA-P695. The minimum rotation capacity of intermediate steel moment frames required to satisfy seismic performance as well as the major design values affecting the seismic performance of moment frame areestimated. To that goal, the design parameters are selected and various target frames are designed. The analysis models of the main nonlinear elements are also developed for evaluating seismic performance. The resultsshow that the 20-story structure doesnot meet the seismic performance even if it satisfies the rotation capacity of 0.02 radian.
        4,000원
        45.
        2014.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 2경간 합성바닥슬래브의 기여도를 반영하여 철골모멘트골조의 연쇄붕괴저항성능의 더욱 정확한 평가를 위해 사용할 수 있는 개선된 에너지기반 비선형정적 해석법을 제시하고자 한다. 이를 위해, 우선 재료적/기하학적 비선형 유한요소해석을 수행하여 2경간 합성바닥슬래브의 거동을 살펴보았다. 2경간 합성바닥슬래브의 변형형상을 이상화하여 에너지기반 해석을 위한 근사모델을 개발하였다. 제안모델은 기둥제거 시나리오하에서 2경간 합성바닥슬래브의 일방향 축인장력 및 변형에너지응답을 모델링하는데 쉽게 이용할 수 있음을 보여주고 있다.
        4,000원
        46.
        2013.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The circular hollow section is usually used for member of main frame to carry the external load in single layer lattice dome. But, the H-shaped section may be used for member of main frame since it is convenient for attaching roof panels. Single layer lattice domes have various buckling characteristics, such as the overall buckling, the member buckling, and nodal buckling. The purpose of this study is to compare buckling characteristics of single-layer lattice domes in which the H-shaped steel section as the existing domestically-produced structural steel is used as main frames to those of domes in which a circular hollow section is used as main frames.
        4,000원
        47.
        2013.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 반강접을 고려한 프레임 구조에서 강재 탄성계수의 불확실성이 프레임 구조의 비선형거동에 미치는 영향을 분석하였다. 강재 탄성계수의 불확실성의 확률분포는 정규분포로 모델링 하였으며, 이러한 확률적 물성치를 반강접 프레임의 비선형 거동에 적용할 수 있는 해석 프로그램을 개발하였다. 프레임의 비선형 거동 인수인 기하학적 비선형, 재료적 비선형, 그리고 접합부의 반강접에 의한 비선형 효과를 고려하여, Monte Carlo Simulation에 기반한 확률론적 해석을 수행하였다. 확률론적 해석을 위해 확률변수를 세 종류로 생성하여 사용하였다. 확정론적 해석의 결과는 기존의 연구 결과와 잘 일치하는 결과를 보였다. 확률론적 해석의 경우, 변위의 분산계수는 구조에 작용하는 하중이 증가함에 따라 증가하는 결과를 나타냈으며, 그 값은 프레임구조의 구조적 특성에 영향을 받는 것으로 나타났다.
        4,000원
        48.
        2013.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study proposed proposes a retrofitting method using an H‐beam frame to improve the seismic performance of non‐seismic designed reinforced concrete frames. To evaluate the seismic performance with the H‐beam frames, a cyclic lateral load test was performed and the experimental result was compared with the bared frame, and a masonry infilled RC frame. The results was were analyzed regarding aspects of the load‐displacement hysteresis behavior, effective stiffness, displacement ductility, and cumulative energy dissipation. AlsoIn addition, it was possible to prove both an increase of in the maximum load capacity, effective stiffness, and energy dissipation capacity using the H‐beam frame.
        4,000원
        49.
        2013.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, the a static experiment of on two reinforced concrete (RC) frame sub‐assemblages was conducted to evaluate the seismic behaviors of existing RC frames that were not designed to support a seismic load. The specimens were a one span and actual‐sized. One of them had two columns with the same stiffness, but the other had two columns with different stiffness values. As Regarding the test results, lots of many cracks occurred on the surfaces of the columns and beam‐column joints for the two specimens, but the cover concrete splitting hardly occurred was minimal until the test ends. In the case of the specimen with the same stiffness offor the two columns, the flexural collapse of the left‐side column occurred. However, in the case of the specimen with different stiffness values for of the two columns, the beam‐column joint finally collapsed, even though the shear strength of the joint was designed to be strong enough to support the lateral collapse load. The nonlinear Nonlinear static analysis of the two specimens was also conducted using the uniaxial spring model, and the analytical results successfully simulated the nonlinear behaviour of the specimens in accordance with the test results.
        4,000원
        50.
        2013.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Due to a high level of system ductility, steel moment resisting frames have been widely used for lateral force resisting structural systems in high seismic zones. Earthquake field investigations after Northridge earthquake in 1994 and Kobe earthquake in 1995 have reported that many steel moment resisting frames designed before 1990's had suffered significant damages and structural collapse. In this research, seismic performance assessment of steel moment resisting frames designed in accordance with the previous seismic provisions before 1990's was performed. Buckling-restrained braces and shear walls are considered for seismic retrofit of the reference buildings. Increasing stiffness and strength of the buildings using buckling-restrained braces and shear walls are considered as options to rehabilitate the damaged buildings. Probabilistic seismic performance assessment using fragility analysis results is used for the criteria for determining an appropriate seismic retrofit strategy. The fragility contour method can be used to provide an intial guideline to structural engineers when various structural retrofit options for the damaged buildings are available.
        4,000원
        51.
        2012.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        국내 철골모멘트골조를 이전 KBC2005 및 현 KBC2009 기준에 따라 설계한 후 비선형동적해석을 이용하여 FEMA355F의 내진성능평가 절차에 따라 성능을 평가하였다. 그 결과 비선형정적 Push-over 해석을 이용한 역량스펙트럼법과 차이가 있었다. 특히국내 철골모멘트골조는 약패널존을 가지기 때문에 비선형동적해석을 통해서만 보다 정확한 거동을 예측할 수 있었다. 국내 철골모멘트골조는 지반 조건 SB 또는 SC에 위치한다면 층수 및 R값에 관계없이 성능목표를 만족하는 것으로 나타났다. 하지만 지반 조건 SD 또는SE에 위치한다면 성능목표 만족 여부는 명확하지 않았다. 따라서 KBC2005나 KBC2009 어떤 기준을 사용하더라도 지반 조건이 상대적으로 좋다면 국내 철골모멘트골조는 내진성능을 충분히 확보하고 있다고 볼 수 있다.
        4,000원
        52.
        2012.03 구독 인증기관 무료, 개인회원 유료
        The recent progressive collapse analysis method of structures assumes the threat-independent removal of vertical load-carrying elements. In reality, a blast-induced column-missing event will produce the damage on adjacent structural elements and the rapid dynamic response of the structures. In this study, the strain rate effects on the dynamic collapse behavior of blast-damaged steel moment frames are investigated by performing the blast-induced sequential progressive collapse analysis of a three-storey steel moment frame.
        4,000원
        53.
        2011.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 인공지진파 및 기록 지진파를 이용하여, KBC2009 규준으로 설계된 강구조 건물의 거대 건물에 대한 내 력 여유도를 평가하는 것을 목표로 하고 있다. 이 논문에서는 검정에 있어서 콘크리트 슬래브로 층강성이 고정되어 있는 2-D 프레임을 고려하였고, 각각의 프레임을 구성하고 있는 보와 기둥 부재는 각 부재단에 소성힌지를 적용하 였다. 검정에 사용한 해석법은 응답 스펙트럼을 이용한 모드 해석과 기록 및 인공지진파를 이용한 시간이력해석을 선택하여 모델의 거동을 조사하였으며 해석에서는 P-delta 효과를 고려한다.
        4,000원
        54.
        2011.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구의 목적은 에너지 흡수형 강재 댐퍼를 이용하여 손상순서를 제어함으로써 주구조체를 재사용 할 수 있는 철골조시스템을 개발하고, 지진응답특성을 파악하는 것이다. 이를 위하여 강재 댐퍼의 형상을 제안하고, 제안된 강재 댐퍼의 변형 형상과 응력 분포를 알아보기 위하여 범용 유한요소해석 프로그램인 ANSYS(ver.10.0)을 이용한 비선형 유한요소해석을 수행하였다. 또한 지진응답특성을 파악하기 위하여 실대형 사이즈 5.4m×2.4m의 1층 철골조 실험체 4개를 설계 및 제작하여 유사동적 지진응답실험을 수행하였다. 본 연구에서 제안하는 강재 댐퍼를 제진요소로 사용하는 경우, 주구조체에 비하여 높은 강성을 갖는 댐퍼가 소폭의 변위에 먼저 소성화함으로써 이력에 의한 지진에너지를 흡수할 수 있으며, 지진응답에서 유리한 것이 판명되었다.
        4,000원
        55.
        2011.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        현재 국내 철골 모멘트골조 접합부는 대부분 공장제작으로 품질관리가 잘 이루어져 연성능력이 상당한 수준이다. 문헌에 의하면 국내 접합부는 미국 철강협회에서 철골 중간모멘트골조에 대해 제시한 성능 기준을 충분히 만족하고 있다. 그런데 이전 설계기준인 KBC2005에서는 철골모멘트골조에 연성모멘트골조 하나만을 제공하였으나 현 KBC2009 기준은 보통, 중간, 특수모멘트골조로 다양하게 제공하고 있다. 여기서 국내 접합부 형식을 그대로 사용했을 때 어떤 시스템이 적합한지 조사할 필요성이 있다. 따라서 본 연구에서는 KBC2005의 연성모멘트골조와 KBC2009의 중간모멘트골조의 거동을 비교하여 국내에 적합한 설계 방법을 찾고자 하였다. 연구 결과 기존 연성모멘트골조의 설계 계수를 따르더라도 성능목표를 충분히 만족하는 것으로 나타났다.
        4,000원
        56.
        2010.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        안전한 내진설계를 위해서는 부재에 요구되는 소성변형을 평가하여야 한다. 본 연구에서는 복잡한 비선형해석없이 탄성 해석결과에 근거하여 이중골조의 부재소성변형을 평가할 수 있는 빠르고 간편한 방법을 개발하였다. 보, 기둥, 벽체 등의 소성변형은 부재강성, 층간변위비, 모멘트 재분배, 단면치수 및 소성힌지 위치의 함수로 결정된다. 벽체와 보가 모멘트 접합된 경우에는 벽체의 소성변형에 의한 로킹효과를 고려하여 증가된 소성변형을 구한다. 8층 이중골조에 대하여 제안된 방법을 적용하였고, 비선형해석을 통하여 제안된 방법의 정확성을 검증하였다. 제안된 방법은 단순계산으로 부재소성변형을 합리적으로 예측하지만, 정확한 부재소성변형 평가를 위해서는 비탄성 층간변위비의 정확한 예측이 필요한 것으로 나타났다. 제안된 방법은 향후 성능중심 내진설계에 활용할 수 있을 뿐만 아니라 기존 건물의 성능평가에도 활용될 수 있을 것이다.
        4,200원
        57.
        2010.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        국내 비내진 설계된 RC 골조 외부접합부의 횡저항 능력특성을 연구하기 위하여, 1988년 이후의 건물을 대상으로 실물 크기의 70%의 T형 보-기둥 실험체 4개를 제작하여 보에 횡력을 가력하여 실험을 수행하였다. 작용한 횡력은 총 9단계로 변위를 조절하여 최대 횡변위비 3.5%까지 가력하였고, 각 변위 단계마다 3싸이클의 반복하중을 가력하였다. 실제의 상황과 유사하게 하기 위하여 실험동안 기둥에 압축력을 지속적으로 작용하였다. 실험 결과, 부재가 휨 공칭강도에 도달하여야 하는 내력에 비하여 실험 결과는 85%이하로 나타났고 층간변위비 0.85% 미만에서 모든 실험체의 접합부에서 전단균열이 발생하여 국내 외부접합부가 취약함을 확인할 수 있었다. 또한 접합부 균열발생시 주응력-층간변위비는 Priestly의 제안식과 유사하게 나타났다.
        4,000원
        58.
        2010.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 기둥을 관통하는 슬래브 하부 철근이 중력하중만으로 설계된 포스트텐션 플랫플레이트 골조의 내진성능에 미치는 영향을 평가하였다. 중 약진 지역에서 건물은 흔히 중력하중만을 고려하여 설계되고 있다. 본 연구에서는 중력하중으로 설계된 PT 플랫플레이트 골조의 내진성능에 집중되고 있다. 이를 위하여, 3,6,9층 PT 플랫플레이트 골조는 중력하중만으로 설계하였다. 철근콘크리트 플랫플레이트 골조에서는 취성적인 붕괴를 예방하기 위해서는 기둥을 관통하는 연속된 슬래브 하부철근이 위치하여야 한다. 그러나 PT 플랫플레이트 골조에서는 슬래브 하부 철근에 대해 ACI 318-05에서는 특별한 언급이 없기 때문에 흔히 생략하고 있다. 본 연구는 대산건물을 비선형 시간이력해석 으로 골조 모델의 내진성능에 대해 평가한다. 비선형 시간이력해석은 6개의 지진과 2개의 다른 위험수준 (475, 2475년 주기), 3개의 다른 지역 (보스턴, 시애틀, LA)을 사용하였다. 해석모델은 PT슬래브-기둥 접합부의 파괴 메카니즘과 비선형 거동을 살펴보기 위해 개발되었다. 본 연구는 중력하중으로 설계된 PT 플랫플레이트 골조가 몇몇 내진저항 능력을 보여주고 있다. 또한, PT 플랫플레이트 골조의 내진성능은 기둥을 관통하는 슬래브 하부철근이 위치할 때 눈에 띄게 향상되었다.
        4,000원
        59.
        2010.03 구독 인증기관 무료, 개인회원 유료
        Most of the school buildings were built before the seismic code was established. To consider the sunlight and ventilation to the partition walls are built about 1m height beside columns at typical school buildings. For the reason, columns which is consisted school building occur brittle failure shape by the reduced effective depth. In this study, experimental test for retrofitting effect by Aramid Fiber Reinforced Polymers(AFRP) strips on masonry infilled reinforced concrete(RC) frames is performed. The test results were to ensured enough time to evacuate due to the enhancement of ductility and strength of school buildings to withstand earthquakes using AFRP strips .
        4,000원
        60.
        2010.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 반복 횡하중 하에서 CFRP(Carbon Fiber Reinforced Polymer) Sheet로 보강된 철근콘크리트 프레임면내 조적벽체의 전단내력을 평가하여 국내 조적벽체 학교 건축물에 적합한 CFRP Sheet 보강 방안을 제안하는 것에 그 목적이 있다. 조적 허리벽이 있는 1층, 1경간, 1/2 스케일의 시험체를 4개 제작하여 CFRP Sheet의 보강량을 변수로 실험을 수행하였으며 이를 통하여 보강량에 따른 강도와 강성의 변화를 분석하였다. 실험 결과 CFRP Sheet는 시험체의 내력과 강성을 향상시켰으며 특히 기둥과 조적벽을 모두 보강하는 방법을 통한 보강방법에 있어 그 적용성을 확인할 수 있었다.
        4,000원
        1 2 3 4 5