        121.
        2023.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study presents a dry precast concrete (PC) beam-column connection, and its target seismic performance level is set to be emulative to the reinforced concrete (RC) intermediate moment resisting frame system specified in ACI 318 and ASCE 7. The key features include self-sustaining ability during construction with the dry mechanical splicing method, enabling emulative connection performances and better constructability. Test specimens with code-compliant seismic details were fabricated and tested under reversed cyclic loading, which included a PC beam-column connection specimen with dry connections and an RC control specimen. The test results showed that all the specimens failed in a similar failure mode due to plastic deformations in beam members, while the hysteretic response curve of the PC specimen showed comparable and emulative performances compared to the RC specimen. Seismic performance evaluation was quantitatively addressed, and on this basis, it confirmed that the presented system can fully satisfy all the required performance for the intermediate RC moment resisting frame.
        4,000원
        122.
        2023.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문은 CFRP Grid를 철근 대체재로 사용하기 위해 수행된 실험적 및 해석적 연구를 보고한다. CFRP Grid가 철근 대신 적용된 콘크리트 보의 휨거동을 평가하기 위해 총 5개의 콘크리트 실험체가 제작되었다. 실험변수로 CFRP Grid의 보강 겹 수, 피복두께가 고려되었다. 3점 휨실험을 통해 모든 실험체는 휨파괴됨을 확인하였다. 특히, 2겹과 3겹의 CFRP 그리드를 갖는 실험체는 CFRP Grid의 급작스런 파단으로 파괴되었다. 초기 균열하중은 CFRP Grid 보강 겹 수가 증가할수록 증가하였다. 반면 초기균열하중에 대한 피복두께의 영향은 명확하게 나타나지 않았다. 극한하중은 CFRP Grid의 보강 겹수 및 피복두께의 영향이 명확하게 나타났다. CFRP Grid로 보강된 콘크리트 보의 휨거동을 예측하기 위한 유한요소해석 결과는 실험체들의 균열양상 및 파괴모드를 유사하게 예측하였다. 특히, 극한하중, 극한하중에 대응하는 처짐, CFRP Grid의 변형률을 매우 유사하게 예측하는 것으로 나타났다. 따라서 본 연구에서 제안된 해석모델은 CFRP Grid가 철근 대체제로 사용된 콘크리트 보의 휨거동을 예측하기 위해 효과적으로 사용될 수 있을 것으로 판단된다.
        4,000원
        123.
        2023.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 수직 벽체형 콘크리트 구조물의 정밀안전진단을 위한 외관조사시 고품질 정밀영상을 자동화된 방식으로 획득하여 균열손상을 탐지하고 시설물의 상태를 평가하기 위하여 개발된 등벽드론 탑재형 균열진단 시스템에 대한 것이다. 본 논문에서는 영상기반 균열진단 시스템을 이용한 정밀영상 획득기술, 자동화된 영상처리 알고리즘을 이용한 데이터 처리 기법을 제시하였으며, 실험적으로 도출된 지상표본거리를 기반으로 영상처리 자동화 알고리즘을 이용하여 생성된 균열모사 시험벽체의 평면전개 이미지 상 균열손상의 위치 정확도를 평가 분석하였다. 평가분석 결과, 가로축 길이 대비 최대 1.1%, 세로축 길이 대 비 최대 1.4%의 오차율을 보이는 것으로 나타났다. 제안된 영상 내 픽셀 좌표와 지상표본거리를 기반으로 균열손상의 위치를 추정하는 기법은 실측 좌표 대비 평균 1.0% 이하의 위치 오차를 가지는 것으로 평가되었다. 최종적으로 영상기반 진단과 긴급 보수와 같은 일반적인 시설물의 유지관리에 요구되는 위치 정확도를 확보하고 있는 것으로 분석되었다.
        4,000원
        132.
        2023.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : This study investigated the field applicability of pervious concrete to pavement base courses. Pervious concrete was developed at laboratory level, and the compaction methods, field moisture content, and fundamental properties when the material was constructed in the field were studied. METHODS : Field-applied pervious concrete was compacted at different levels using a tandem roller, and cores were taken to investigate the compressive strength, infiltration rate, continued porosity, and freeze-thaw resistance. In addition, the optimum field construction and quality control of the moisture content of a batch plant were measured. RESULTS : The moisture content of pervious concrete has an essential effect on workability and quality control during field test construction. From the test herein, the optimum value at a batch plant was found to be approximately 2.5±0.1%. The compaction level is also a crucial parameter at construction sites because it affects the mechanical and penetration properties. Considering both compressive strength and drainage, the recommended compaction was three times the round trip when a tandem roller was used. The penetration coefficient was 0.88 cm/sec when applying three times the round trip of the tandem roller. The freezing and thawing weight loss rates of the applied pervious concrete satisfied the required condition of 14% or less, regardless the compaction level. CONCLUSIONS : With the suggested mixed proportions of pervious concrete, the recommended compaction was three times the round trip of a tandem roller and a moisture content of approximately 2.5±0.1% from a batch plant. When these conditions were satisfied, the mechanical and drainage properties satisfied the required criteria.
        4,000원
        133.
        2023.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : Advancements in science and technology caused by industrialization have led to an increase in particulate matter emissions and, consequently, severity of air pollution. Nitrogen oxide (NOx), which accounts for 58% of road transport pollutants, adversely affects both human health and the environment. A test-bed was constructed to determine NOx removal efficiency at the roadside. TiO2, a material used to reduce particulate matter, was used to remove NOx. It was applied to a vertical concrete structure using the dynamic pressurized penetration TiO2 fixation method, which can be easily applied to vertical concrete structures. This study was conducted to evaluate the NOx removal efficiency of the dynamic pressurized-penetration TiO2 fixation method in a test-bed under real roadside conditions. METHODS : A test-bed was constructed in order to determine the NOx removal efficiency using the dynamic pressurized penetration TiO2 fixation method on the roadside. The dynamic pressurized-penetration TiO2 fixation method was applied by installing a vertical concrete structure. NOx was injected into the test-bed using an exhaust gas generator. By installing a shading screen, the photocatalytic reaction of TiO2 was suppressed to a maximum concentration of 1000 ppb along the roadside. The removal efficiency was evaluated by measuring NOx concentrations. In addition, illuminance was measured using an illuminance meter. RESULTS : From the results of the analysis of the NOx removal efficiency in the test-bed which the dynamic pressurized type TiO2 fixation method was applied to, an average removal efficiency ranging from 18% to 40% was achieved, depending on the illuminance. Similarly, according to the results of the evaluation of the NO removal efficiency, an average of removal efficiency ranging from 20% to 62% was achieved. Thus, the NOx removal efficiency increased when the illuminance was high. CONCLUSIONS : From the results of the experiment conducted, the efficiency of NOx removal per unit volume was obtained according to the illuminance of TiO2 concrete along an actual road. Field applicability of the dynamic pressurized-penetration-type TiO2 fixation method to vertical concrete structures along roads was confirmed.
        4,000원