This study developed a scenario to understand the reaction rate and operational time according to RTI value of rate of rise detector in each type in case of fire mattress. In the results of analyzing the reaction rate and operational time of detector in each scenario, in case when installing a single detector, the elevated temperature per minute was raised to 8℃/min ~ 9℃/min. In case when installing two detectors, it was raised to 9℃/min ~ 10℃/min. In case when installing three detectors, it was raised to 10℃/min. The horizontal distance between detector and mattress was 1.8m~2.5m. Whenever the number of detectors was increased, the horizontal distance was decreased. The operational time of detector was within maximum 540 seconds and minimum 420 seconds. As the research tasks in the future, there should be the researches on the effects of reaction rate of detector on the evacuation in case of fire through the result value of RSET by setting up the latency until the detector operates, and the researches on the safety by understanding if the operational time of detector is suitable for the evaluation standard of performancecentered design.
In this paper which was performed to bring public attention to the need for developing an photoelectric smoke detector that detects smokes emitted from diverse fire sources, it was confirmed that the photoelectric smoke detector may not respond to certain smoke types depending on the size and color of smoke particles. The test was performed on a photoelectric smoke detector which is being used generally for specific fire targets specified in UL268, including paper fire, wood fire and flammable liquid fire, while the actual response performance of the fire detector, as well as respective smoke particles collected from different fire source which were photographed with a SEM(Scanning electron microscope) were analyzed in the test for this study.
Fire detectors are designed to minimize loss of life from a fire alarm system as an alarm to help evacuate more quickly until the completion of the evacuation alarm should be continued. the purpose of such alarms in order to achieve the characteristic fire heat release rate reaches a certain level, or when a certain time has elapsed, when the heat detector is to be alarms to answer. Requires a quick response, it is desirable to install the sensor as much as possible, but taking into account the cost of installation problems by engineering approach to minimize the quantity and rapidity of detection capability should be increased. In order to increase the rapidity of fire detectors in a room according to the height of the sensing period is to be maintained the optimum distance of the fire detector detects characteristics should be considered. Differential spot-type heat detectors installed domestic basis, depending on the type of sensor that can detect one sensor area is limited and less than 4m ceiling height regulations and simply double the number in excess of 4m and intended to be installed
Recent research on stand-alone focused on the improvement and development of functions for solving problems such as the limited operating time of stand-alone installed at dwelling and their low reliability caused by false alarms, but it is more urgent to study on the operating range of stand-alone sensor in consideration of the impacts of combustion products on residents because the primary goal of fire safety is minimizing casualties. This study purposed to propose the optimized operating range of stand-alone sensor in consideration of the impacts of combustion products on residents. For this purpose, we made a mathematical approach to the change of temperature over the lapse of time in compartment fires similar to house fires, and established the standards of the body's response against heat and smoke based on literature review. In addition, we surveyed domestic and foreign technological standards for stand-alone sensor, and converted them to standards for residents of the body's response against heat and smoke using mathematical model equations and analyzed them comparatively.
Recently as the testing of fire detector used the testing device for fire detector, there are something the matter in the perception function loss of fire detector, structure and form of the testing device for fire detector. The problem at oxidation of emitting smoke ashes hazardous article part and so on that checking person absorbs be. In this paper the problem or the conventional the examination equipment of fire detectors is analysed and researched. To solve these problems after the theoretical study and design and paint drawing of equipment the prototype of composite examination equipment of fire detectors was made. After compared with the conventional, part that improve of composite examination equipment of fire detectors are verified through the examination. In the future it will be useful the operation state and correct operation time of the fire detectors are measured after the research about the quality of the material and transparency of bellows cover is done.
본 연구에서는 판형태의 압전감지기와 압전작동기가 접착되어 있는 보형태의 스마트구조물의 자유진동제어에 대한 유한요소모형화 방법을 제안한다. 압전재료의 직접압전효과와 역압전효과에 대한 구성방정식을 고려하고 변분원리를 이용하여 스마트보유한요소의 운동방정식을 유도한다. 이러한 2절점 보 유한요소근 등매개변수요소로서 Timoshenko 보이론을 기초로 한다. 따라서, 보형태의 스마트구조물을 제안하는 스마트보 유한요소에 의하여 해석함으로써 전압이 작용되는 압전작동기에 의한 구조물의 제어와 전압을 측정하는 압전감지기에 의한 구조물의 모니터링에 대한 수치적인 시뮬레이션이 가능해진다 이러한 스마트보유한요소와 Constant-gain feed back control 기법을 이용하여 압전감지기와 압전작동기를 이용한 보구조물의 자유진동제어에 대한 유한요소 모델을 제안한다
이 연구의 목적은 대형 구조불의 상설 감지를 위한 감지기의 최적 위치의 얄고리츰윷 개발하는데에 있다. 구조물
의 진동을 이용한 감지 시 스템은 장기적 으로 계 속해서 구조물을 자동으로 감지하는데에 좋은 방법 증의 하나이다.
하지만 구조물의 진동융 정확히 계측하기 위해서 는 감지기의 위치나 감지기의 숫자에 콘 영향을 받는데, 이와 같은
일은 대형 구조물에 있어서 쉽지가 않다. 최적의 감지기 위치와 최소의 감지기로 가장 정확한 데이터를 획득하기
위하여 최적합한 감지기의 위치를 위한 알고려즘이 개발되어 수치 적 그리고 실험적으로 유용성 을 보인다. EOT가
개발되어 모형 교량에 적용하여 EIM과 비교 분석된다 이 들의 비교를 똥하여, 이 연구에서 제안되어진 EOT가 적
은 수의 감지기로 좋은 걸과를 보여, 상설감지의 복적에 적합함을 보여 준다.
화재가 발생하면 열과 연기생성물이 발생하는데 화재로부터 발생되는 온도변화는 일반적인 대기 온도의 변화와 상당한 차이가 있기 때문에 이 온도변화를 감지하여 조기에 화재발생을 포착할 수 있다. 또한 연기가 발생하면 시계(視界)가 줄어드는 것을 감지할 수 있다. 화재를 좀더 정확하게 감지하려면 화재에 의한 화재징후는 기기로 측정할 수 있을 만큼 주위 환경을 변화시키고 이 변화값은 그 환경의 평상시 변수보다 커야 한다. 화재감지기는 화재로부터 발생하는 화재징후인 열, 연기 등을 감지하여 화재발생을 조기에 관계자에게 경보하는 기기이다[1-3].
실제 환경에서는 화재가 아닌 경우에도 화재감지기의 고정된 수치 이상 발생할 수 있고, 화재가 발생했어도 고정된 수치 이하로 열, 연기 등이 발생할 수 있다. 이와 같은 화재감지기의 완벽하지 못한 신뢰성 때문에 경종, 사이렌 등 경보장치의 소음으로 인하여 사람들이 불편을 겪는 경우가 있고, 심지어 화재감지기의 전원을 OFF시키는 경우도 있어 실제 화재가 발생하였을 때 화재로 인한 대참사를 야기시킬 수도 있다.
본 연구는 가연물 종류에 따른 화재감지기의 응답특성을 분석한 연구로 다양한 가연물을 연소시킨 다음 화재감지기의 설치위치 등에 따라 감도특성이 어떻게 변화하는 가를 확인하였다. 가연물 종류는 열이 주로 발생하는 알코올, 연기가 주로 발생하는 면심지와 열과 연기가 다량으로 발생하는 N-heptane을 사용하였고 화재감지기 설치위치는 벽체와 천장으로부터 이격된 거리에 따라 실험을 수행하였다. 그 결과 벽 또는 천장에서 이격거리가 클수록 감도특성이 저하되는 것을 확인하였다.