For the OPR1000, a standard power plant in Korea, an analytical model of the containment building considering voids and deterioration was built with multilayer shell elements. Voids were placed in the vulnerable parts of the analysis model, and the deterioration effects of concrete and rebar were reflected in the material model. To check the impact of voids and deterioration on the seismic performance of the containment building, iterative push-over analysis was performed on four cases of the analytical model with and without voids and deterioration. It was found that the effect of voids with a volume ratio of 0.6% on the seismic performance of the containment building was insignificant. The effect of strength reduction and cross-sectional area loss of reinforcement due to deterioration and the impact of strength increase of concrete due to long-term hardening offset each other, resulting in a slight increase in the lateral resistance of the containment building. To determine the limit state that adequately represents the seismic performance of the containment building considering voids and deterioration, the Ogaki shear strength equation, ASCE 43-05 low shear wall allowable lateral displacement ratio, and JEAC 4601 shear strain limit were compared and examined with the analytically derived failure point (ultimate point) in this study.
원전 구조물의 실시간 모니터링 기술이 요구되고 있지만, 현재 운영 중인 지진 감시계통으로는 동특성 추출 등 시스템 식별이 제한 된다. 전역적인 거동 데이터 및 동특성 추출을 위해서는 다수의 센서를 최적 배치하여야 한다. 최적 센서배치 연구는 많이 진행되어 왔 지만 주로 토목, 기계 구조물이 대상이었으며 원전 구조물 대상으로 수행된 연구는 없었다. 원전 구조물은 미미한 신호대잡음비에도 강건한 신호를 획득하여야 하며, 모드 기여도가 저차 모드에 집중되어 있어 모드별 잡음 영향을 고려해야 하는 등 구조물 특성을 고려 해야 한다. 이에 본 연구에서는 잡음에 대한 강건도와 모드별 영향을 평가할 수 있는 최적 센서배치 방법론을 제시하였다. 활용한 지표 로서 auto MAC(Modal Assurance Criterion), cross MAC, 노드별 모드형상 분포를 분석하였으며, 잡음에 대한 강건도 평가의 적합성을 수치해석으로 검증하였다.
Conditional spectra (CS) are applied to the seismic fragility assessment of a nuclear power plant (NPP) containment building for comparison with a relevant conventional uniform hazard response spectrum (UHRS). Three different control frequencies are considered in developing conditional spectra. The contribution of diverse magnitudes and epicentral distances is identified from deaggregation for the UHRS at a control frequency and incorporated into the conditional spectra. A total of 30 ground motion records are selected and scaled to simulate the probability distribution of each conditional spectra, respectively. A set of lumped mass stick models for the containment building are built considering nonlinear bending and shear deformation and uncertainty in modeling parameters using the Latin hypercube sampling technique. Incremental dynamic analysis is conducted for different seismic input models in order to estimate seismic fragility functions. The seismic fragility functions and high confidence of low probability of failure (HCLPF) are calculated for different seismic input models and analyzed comparatively.
최근 국내 원자력발전소의 격납건물 벽체와 Containment Liner Plate(CLP) 사이에서 다양한 크기의 공극이 발견됨에 따라 원전 격납건물의 보수를 위해 내부 공극의 분포와 크기를 정밀하게 평가할 수 있는 진단기법의 개발이 요구되고 있다. 이에 따라 이 연구에서 는 격납건물 벽체에서의 탄성파 전파거동을 계산하는 2차원 유한요소해석 기법을 제시한다. 격납건물 벽체를 기반으로 해석영역을 구성하고 경계면에서의 반사파를 제거하기 위해 수치적 파동흡수 경계층인 perfectly matched layer를 도입하였다. Galerkin 기반 혼합 유한요소법을 이용해 2차원 유한영역에서 탄성파 파동방정식의 해를 구하여 충격하중에 대한 격납건물 벽체의 변위와 응력을 계산하였다. 제시한 수치적 기법을 이용하여 격납건물 콘크리트 벽체의 CLP 부착 유무와 공동의 위치 및 크기 변화에 따른 탄성파 전파거 동을 살펴보았다. 이 연구의 결과는 원전 격납건물 내부의 공동을 진단하는 탄성파 전체파형 역해석 기법 개발에 활용될 수 있다.
In this study, in order to observe the effect of guide bar installation conditions on the ship’s anchor containment by varying the guide bar installation conditions were comprehensively observed. The proper installation of the guide bar, it is possible to improve the hammering phenomenon that occurs when the anchor chain falls vertically. It was confirmed that the anchor storage condition could be improved not only by the guide bar, but also by adding a welding bead at an appropriate location. The capacity of the power source has a significant effect on the anchor pendulum motion.
A methodology to assess seismic fragility of a nuclear power plant (NPP) using a conditional mean spectrum is proposed as an alternative to using a uniform hazard response spectrum. Rather than the single-scenario conditional mean spectrum, which is the conventional conditional mean spectrum based on a single scenario, a multi-scenario conditional mean spectrum is proposed for the case in which no single scenario is dominant. The multi-scenario conditional mean spectrum is defined as the weighted average of different conditional mean spectra, each one of which corresponds to an individual scenario. The weighting factors for scenarios are obtained from a deaggregation of seismic hazards. As a validation example, a seismic fragility assessment of an NPP containment structure is performed using a uniform hazard response spectrum and different single-scenario conditional mean spectra and multi-scenario conditional mean spectra. In the example, the number of scenarios primarily influences the median capacity of the evaluated structure. Meanwhile, the control frequency, a key parameter of a conditional mean spectrum, plays an important role in reducing logarithmic standard deviation of the corresponding fragility curves and corresponding high confidence of low probability of failure (HCLPF) capacity.
국가 주도로 2009년부터 개발중인 경수로 사용후핵연료 건식저장시스템은 금속 겸용용기와 콘크리트 저장용기의 두 가지 방식이다. 국외 건식저장시설 운영 시 주요 격납감시 방안으로는 금속 겸용용기인 경우 이중 뚜껑 사이에 압력센서를 설치 하여 실시간 압력변화를 감시하는 방법이 있고 콘크리트 저장용기의 경우는 캐니스터 기반으로 주요 격납 경계인 뚜껑을 이중으로 용접하는 방식으로 구조물(over pack 또는 module)의 공기 유로인 입구 및 출구에 대한 온도 변화를 감시하는 방 법으로 격납을 관리하는 것으로 나타났다. 미국, 독일 등 30 년 이상 안정적으로 저장시설을 관리한 국가의 다양한 적용기 술 및 운영사례를 조사/분석하여 우리가 개발중인 저장시스템에 적용할 수 있는 격납감시 방안을 도출하는데 활용할 수 있 도록 하였다.
원자로 격납건물은 냉각재상실사고와 같이 내부의 과도한 압력이 유발되는 사고에 있어서도 방사성 물질이 외부로 누출되지 않도록 막는 최종의 방벽이다. 이러한 격납건물의 기능적 중요성에 기인하여, 건설 초기 구조건전성시험(SIT)을 수행한다. 이러한 SIT거동을 가장 실제와 가깝게 예측하기 위한 해석 연구를 수행하였다. 해당 연구의 결과는 2편의 논문으로 정리되었는데, 본 논문은 그 중 II편으로 I편의 해석모델 구성 시의 주요 고려사항의 분석 및 예비해석 결과를 반영한 상세 해석 모델의 구성 과정 및 해석 결과를 제시하고 있다. 특히 비부착식 텐던으로 시공된 구조물에서 덕트관에 의한 강성 저감효과 및 덕트관을 사이에 둔 텐던과 콘크리트간의 밀착 여부에 따른 영향을 해석 시 최대한 고려하고자 하였다. 이러한 과정을 통해 구축된 해석 모델에 따른 변위과 신고리 3호기 SIT 측정변위를 비교한 결과, ASME CC-6000 기준을 충분히 만족시키는 결과가 나타남을 확인하였다.
원자로 격납건물은 냉각재상실사고와 같이 내부의 과도한 압력이 유발되는 사고에 있어서도 방사성 물질이 외부로 누출되지 않도록 막는 최종의 방벽이다. 이러한 격납건물의 기능적 중요성에 기인하여, 건설 초기 구조건전성시험(SIT)을 수행한다. 신고리 3호기 SIT 시험 당시 계측된 변위를 예측하기 위한 초기 해석 모델은 일부 위치에서 실제 변위를 과소 평가하는 경향을 보임에 따라 이를 개선하고자 하는 연구가 수행되었다. 해당 연구의 결과를 I 편과 II 편의 논문으로 정리하였으며, 본 I 편에서는 초기 해석모델을 개선해가는 과정에서의 해석모델 구성 시의 주요 고려사항의 분석 및 예비해석 결과를 제시하고 있다. 우선적으로 콘크리트 자체의 해석요소(mesh) 구성과 라이너, 철근, 텐던 등의 요소간의 연결 설정이 중요함을 확인하였다. 또한, 다양한 예비해석의 결과를 통해 비부착식 텐던으로 시공된 구조물에서 덕트관에 의한 강성 저감 효과 및 덕트관을 사이에 둔 텐던과 콘크리트간의 밀착 여부에 따른 강성 영향을 적절히 고려하는 것이 중요함을 확인하였다.
In order to increase the seismic safety of nuclear power plant (NPP) structures in high seismicity regions, seismic isolation techniques can be adapted to NPP structures. In this paper, the applicability of multi-step analysis of seismically isolated NPP containment structures with lead-rubber bearings (LRB) is evaluated. The floor response spectrum of NPP containment structures with equivalent linear LRB and nonlinear LRB are compared. In addition, the force-displacement relationships for equivalent linear LRB and nonlinear LRB are compared.
본 연구에서는 비선형 유한요소 해석 기법을 적용한 격납건물의 내압취약도 평가를 수행하였다. 대상 구조물은 국내 대표적인 가압경수로형 원전 격납건물 중 하나로 하였다. 비선형 극한내압 해석을 위해 대규모 개구부를 고려한 격납건물의 3차원 유한요소 모델을 도출하였다. 재료 특성 및 구조적 성능에 내포된 불확실성을 고려하기 위하여 각 변수들의 변동성에 대한 극한내압 성능의 민감도 해석을 수행하였다. 민감도 해석 결과를 통해 확률론적 내압 취약도 평가를 위한 불확실성 변수 및 분포 특성을 도출하였다. 현재의 텐던 긴장력 상태를 고려하기 위하여 가동 중 검사 보고서에 기록된 텐던 긴장력 값을 중앙값으로 적용하였다. 누설(leak)과 파단(rupture)을 파괴모드로 정의하고, 각각에 대한 극한내압 취약도 평가를 위하여 한계상태를 정의하였다. 각 파괴모드에 대한 대상 격납건물의 내압취약도를 내압 성능 중앙값, 고신뢰도 저파괴확률 성능값, 신뢰도 수준에 따른 취약도 곡선을 통하여 제시하였다. 누설 및 파단 파괴모드에 대한 고신뢰도 저파괴확률값은 각각 0.7991 MPa, 0.8691 MPa로 평가되었다.
According to natural frequency of soil, characteristics of earthquake responses of an isolated containment building in nuclear power plants are examined. For this, earthquake response analysis of seismically isolated containment buildings in nuclear power plants is carried out by strictly considering soil-structure interactions. The structure and near-field soil are modeled by the finite element method while far-field soil by consistent transmitting boundary. The equation of motion of a soil-structure interaction system under incident seismic wave is derived. The derived equations of motion are solved to carry out earthquake analysis of a seismically isolated soil-structure system. Generally, the results of this analysis show that seismic isolation significantly reduces the responses of the soil-structure system. However, if the natural frequency of the soil is similar to that of the soil-structure system, the responses of the containment buildings in nuclear power plants rather increases due to interactions in the system.
본 연구에서는 여객용 항공기 충돌 시 강섬유보강콘크리트를 사용한 철근콘크리트 원전 격납건물의 구조적 거동을 유한요소해석을 이용하여 고찰한다. 항공기 충돌에 의해 원전 격납건물에 가해지는 하중은 Riera 충격하중 시간함수와 충돌 시 접촉면적을 이용하여 모델링하였다. 강섬유보강콘크리트의 재료모델은 CSCM Concrete Model을 사용하였다. 기존에 제안된 강섬유보강콘크리트의 강도예상모델을 이용하여 재료모델의 입력변수를 결정하였다. 강섬유의 함유량에 따른 원전 격납건물의 항공기 충돌에 대한 구조적 거동을 상용 유한요소 해석 프로그램인 LS-DYNA를 이용하여 해석하였다. 해석결과를 바탕으로 항공기 충돌에 대한 저항성을 평가하였으며, 보수적인 안전성이 요구되는 원전 격납건물에 강섬유보강콘크리트를 적용할 경우 항공기 충돌에 대한 저항성 증대 효과를 기대할 수 있는 것으로 고찰되었다.