검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 14

        1.
        2020.12 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        A zinc-air battery consists of a zinc anode, an air cathode, an electrolyte, and a separator. The active material of the positive electrode is oxygen contained in the ambient air. Therefore, zinc-air batteries have an open cell configuration. The external condition is one of the main factors for zinc-air batteries. One of the most important external conditions is temperature. To confirm the effect of temperature on the electrochemical properties of zinc-air batteries, we perform various analyses under different temperatures. Under 60 oC condition, the zinc-air cell shows an 84.98 % self-discharge rate. In addition, high corrosion rate and electrolyte evaporation rate are achieved at 60 oC. Among the cells stored at various temperature conditions, the cell stored at 50 oC delivers the highest discharge capacity; it also shows the highest self-discharge rate (65.33 %). On the other hand, the cell stored at 30 oC shows only 2.28 % self-discharge rate.
        4,000원
        4.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        근권부 공기순환 덕트 냉방이 온도 및 생육에 미치는 영향을 구명하고자 고온기 파프리카((Capsicumannum.L. ‘Veyron’)을 코이어배지에서 수경재배하였다. 냉방시간 처리는 24시간 연속 가동한 연속냉방(All-day), 17시부터 다음날 1시까지 8시간 냉방한 야간냉방(Night), 대조구인 냉방 무처리(Control) 등 3 처리하여 온실 상·하부 온도, 근권온도, 엽온, 과실 특성 및 기관 분배율을 측정하였 다. 근권부 덕트 냉방하였을 때, 고온기(6월 ~8월) 온실 하부(바닥으로부터 40cm)와 상부(바닥으로부터 180cm) 온도, 근권온도는 하강되었다. 대조구와 비교하여 온실 하부/상부 온도 차이가 연속냉방에서는 4.4~5.1oC/ 2.1~3.1oC 하강을, 야간냉방 처리에서는 3.4~3.8oC/ 2.2~2.7oC 하강되었다. 근권온도는 온실 하부 온도 결과와 유사했으며, 연속냉방(22.8oC)> 야간 냉방(24.1oC) > 대조구(27.7oC) 순으로 온도가 낮았다. 연속냉방 처리에서 덕트 위치(통로, 베드하단)와 송풍 방향(45o, 90o, 180o)에 따른 온도 변화를 측정한 결과 덕트의 위치가 통로에 위치하고 송풍방향이 상향(45o) 또는 수평(180o) 인 처리는 지상부 100cm까지의 수직 위치에 따른 온도 차이가 크지 않지 않으면서, 근권부위 온도인 지상 50cm 온도가 낮은 특징을 보였고 베드와 베드 공간 사이로 덕트 송풍 방향이 직각(90o)이였을 때는 바닥과 지 상 50cm 부위의 온도가 높고, 지상 100cm 이상 200cm 부위 온도가 상대적으로 낮았다. 연속냉방 또는 야간냉방 처리했을 때 파프리카 엽온은 오후 7시가 오전 9시 보다 엽온 하강이 컸다. 과실 분배율은 대조구(24.4%)에 비해 연속냉방(48.6%)과 야간냉방(45.6%)에서 높았으며, 평균과중, 과수 및 수량도 연속냉방 처리에서 가장 높았다. 한편 야간냉방 처리에서도 고온기 평균 지상부 및 근권온도를 낮추었으나, 누적된 평균온도가 가장 낮은 연속냉방처리에서 과실로의 동화산물 분배율을 높여 파프리카 수량을 증가시킨 것으로 보인다.
        4,000원
        5.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper analyzed air temperatures at outlet according to condition of absorber plate of the solar air heater. Effects on air temperature at outlet of duct according to absorber plate temperature were analyzed by using numerical analysis technique. And also the effects on air temperatures at outlet were analysed by the height and position of absorber plate. As the results, air temperatures at outlet of duct was small influenced in velocity 5 m/s of inlet according to absorber plate temperature. And the highest outlet average temperature distribution appeared at the height of 2 cm and the bottom absorber plate of duct at the inlet aspect ratio 2.
        4,000원
        8.
        2013.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        외부공기 유입방식에 따른 느타리버섯의 생육특성을 조사하기 위하여 3가지 처리구를 두어 실험한 결과 모든 처리구에서 재배기간 중 온도편차가 발생하였고, 처리구 모두 1, 2, 8월에 가장 높았으며, T2(열교환기)와 T3(기밀실)에서 T1(외부공기 직접유입) 보다 온도편차가 작은 경향이었다. 재배기간 중 냉방시간은 T1(외부공기 직접유입)은 1,090.3시간, T2(열교환기)는 661.1시간, T3(기밀실)은 865.0시간이었고,평균 냉방절감율은 T1(외부공기 직접유입) 대비 T2(열교환기)는 21%, T3(기밀실)은 11%이었다. 재배기간 동안 난방기의 년중 가동시간은 T1(외부공기 직접유입)은 1,506.9시간, T2(열교환기)는 875.6시간,T3(기밀실)은 1,054.2시간으로 T2의 가동시간이 가장 작았고, 년중 평균 난방절감율은 T1(외부공기 직접유입) 대비 T2(열교환기)는 22%, T3(기밀실)은16%이었다. 외부공기 유입방식에 따른 냉방정도(CD-H)는 T1(외부공기 직접유입)>T3(기밀실)>T2(열교환기)의 순이었고, 난방정도(HD-H)도 냉방정도(CD-H)의 경우와 동일하였다. 수량은 T2(열교환기)와 T3(기밀실)에서 T1(외부공기 직접유입) 보다 4,9, 10월을 제외한 전 기간에서 높았다.이와 같은 결과로 시설재배사에서 느타리버섯 병재배시 열교환기 또는 기밀실을 설치하여 재배할 경우에너지를 절감할 수 있고, 수량 및 고품질의 느타리버섯을 수확할 수 있어 농가소득증대에 기여할 것으로 판단되었다.
        4,000원
        12.
        2015.06 KCI 등재 서비스 종료(열람 제한)
        Heat is generated from decomposition of wastes as a result of chemical and biological processes in aerated landfills. The purpose of this study was to assess temperature and predict its variations in an aerated landfill. In the phase of aeration, temperature was increased slightly from 30 to 34oC until 65 days and then increased significantly from 34 to 74oC by termination of aeration. It indicates that the amount of oxygen supplied in the starting phase of aeration was insufficient to decompose organic carbon because oxygen supplied in the landfill was only consumed for methane oxidation. Additionally, to minimize the risk of self-ignition, drying and process inhibition, aerated landfills should be operated in a temperature range of 54 ~ 66oC through cooling by water addition and terminating or excessive oxygen supply. In this study, a stoichiometric modeling approach considering methane oxidation and decomposition of organic carbon has been suggested for predicting temperature variations in aerated landfills. As a result, the predicted temperature variations obtained the stoichiometric modeling led to similar results compared with measured temperature in aerated landfill. Therefore, it showed that the stoichiometric approach was appropriate for predicting temperature variation in aerated landfills. In addition, heat generation rates for methane oxidation and decomposition of organic carbon were 89.5 and 387.8 MJ/m3·yr, respectively.
        13.
        2013.11 서비스 종료(열람 제한)
        최근 국제적으로 유가상승과 1차 및 2차 에너지의 제한성으로 인한 에너지위기, 에너지사용량의 증가와 산업화에 따른 기후변화, 기후변화에 따른 환경문제가 지속적으로 이어져오고 있다. 이러한 문제들에 대응하기 위한 수단으로 신재생에너지의 활용 및 연구가 활발하게 진행되고 있으며 우리나라에서도 폐기물을 이용한 바이오가스 생성 및 활용에 많은 연구 및 생산이 이뤄지고 있다. 유기성 폐기물을 이용하여 바이오가스를 생성하는 시설이 증가하고 있어 폐기물질을 처리하는 동시에 새로운 에너지를 생성하고 있다. 우리나라에서 이뤄지고 혐기소화를 통한 바이오가스 생성시설은 대부분 중온소화를 통해 이뤄지고 있으며 중온소화 적정온도인 35℃를 유지하기 위하여 추가적인 에너지 활용이 불가피하다. 따라서 유기성폐기물을 이용하여 효율적인 바이오가스를 생성하기 위하여 연구를 진행하였으며 혐기성소화를 통한 바이오가스 생성 시 중온소화 온도를 유지할 수 있는 새로운 방법을 찾고자 하였다. 호기성산화열에 적용되는 유기물질은 톱밥50%, 두부비지40%, 미강%의 비율로 배합하였으며 미생물의 지속적인 소화 및 온도유지를 위하여 각 소화조마다 1kg의 유기물질을 1일 1회 공급하였다. 또한 호기성소화의 적정 수분함량인 50~60%를 유지하였으며 반응조 내 유기물질의 고른 혼합을 위하여 1일 1회씩 교반하였다. 본 실험은 온도센서가 부착된 60L 반응조 6대를 이용하여 실험을 진행하였으며 공기 유량에 따른 호기성 분해 산화열의 변화를 파악하고자 각 반응조마다 공기주입량을 다르게 설정하였다. 초기반응 시 소화조는 각 소화조는 각각 2L/min 의 유량으로 공기가 주입되며 소화조의 온도가 50℃이상이 되었을 때부터 공기유량이 다르게 주입되도록 설정하였다. 호기성소화 반응조에 투입되는 공기량에 따른 발열반응 실험결과 6번 반응조에서 나타나는 온도 변화가 이상적으로 제어됨을 확인하였다. 다른 반응조보다 반응조 내 온도 변화율이 가장 적었으며 평균 온도 값이 49.94℃로 제어 목표 온도인 50℃에 가장 근접한 값을 나타내었다. 공기량의 투입량이 많을수록 외부 공기의 투입으로 인한 온도저하를 예상하였으나 결과는 예상과는 다르게 공기투입량이 가장 많은 6번 반응조에서 호기 성분해 산화열의 발생이 가장 효율적인 모습을 나타내었다.
        14.
        2013.09 KCI 등재 서비스 종료(열람 제한)
        Desorption characteristics of VOCs were investigated for the effective recovery of gasoline vapor. The adsorption capacity and desorption capacity were excellent at relatively low temperatures. The differences in the desorption capacity were not large in the condition; desorption temperature 25℃, desorption pressure 760 mmHg, inlet air flow rate 0.5 L/min, but were relatively great in the condition; desorption temperature 0℃, desorption pressure 60 mmHg, inlet air flow rate 1.0 L/min. The desorption ability of pentane was increased to about 81.4%, and the desorption ability of hexane was increased to about 102%, also the desorption ability of toluene was increased to about 156.7% by changes of temperature, pressure, inlet air flow rate in the experimental conditions. The optimum desorption condition for the effective recovery of VOCs was in the conditions; desorption temperature 0℃, desorption pressure 60 mmHg, inlet air flow rate 1.0 L/min.