간행물

한국환경과학회지 KCI 등재 Journal of Environmental Science International

권호리스트/논문검색
이 간행물 논문 검색

권호

제22권 제9호 (2013년 9월) 17

ORIGINAL ARTICLE

1.
2013.09 서비스 종료(열람 제한)
This paper presents the results of the electrochemical treatment of chemical oxygen demand(COD) and total nitrogen(T-N) compounds in the wastewater generated from flue gas desulfurization process by using a lab-scale electrolyzer. With the increase in the applied current from 0.6 Ah/L to 1.2 Ah/L, the COD removal efficiency rapidly increases from 74.5% to 96%, and the T-N removal efficiency slightly increases from 37.2% to 44.9%. Therefore, it is expected that an electrochemical treatment technique will be able to decrease the amount of chemicals used for reducing the COD and T-N in wastewater of the desulfurization process compared to the conventional chemical treatment technique.
2.
2013.09 서비스 종료(열람 제한)
The objective of this paper is compare to landuse type for calculating peak flood and soil loss in rapidly expansion urban area. This study compares two landuse maps, including numerical landuse map and aerial photograph landuse map, for calculating the ratio of urban and agriculural area, curve number, time of concentration, peak flood discharge, and soil loss. It is found that flood discharge calculated using aerial photograph landuse map are larger than that calculated using numerical landuse map, and soil loss calculated using aerial photograph landuse map are smaller than that calculated using numerical landuse map. Results also indicate that landuse chage in rapidly expansion urban area significantly influences flood discharge and soil loss.
3.
2013.09 서비스 종료(열람 제한)
The degradation of 3-chlorophenol(3-CP) by various AOPs(Advanced Oxidation Processes) including the ultraviolet / hydrogen peroxide, the Fenton and the ultraviolet(UV)-Fenton process has been conducted. The highest removal efficiency for 3-CP in the aqueous phase was obtained by the UV-Fenton process among the AOPs. In the UV-Fenton process, The removal efficiency of 3-CP decreased with increasing pH in the range of 3 to 6, and it decreased with increasing initial concentration. As the intermediates of 3-CP by UV-Fenton reaction, 3-chlorocatechol, 4-chlorocatechol, and chlorohydroquinone were detected thus the degradation pathways were proposed.
4.
2013.09 서비스 종료(열람 제한)
Tetrafluoromethane(CF4) have been widely used as etching and chemical vapor deposition gases for semiconductor manufacturing processes. CF4 decomposition efficiency using microwave system was carried out as a function of the microwave power, the reaction temperature, and the quantity of Al2O3 addition. High reaction temperature and addition of Al2O3 increased the CF4 removal efficiencies and the CO2/CF4 ratio. When the SA30 (SiC+30wt%Al2O3) and SA50 (SiC+50wt%Al2O3) were used, complete CF4 removal was achieved at 1000℃. The CF4 was reacted with Al2O3 and by-products such as CO2 and AlF3 were produced. Significant amount of by-product such as AlF3 was identified by X-ray powder diffraction analysis. It also showed that the γ-Al2O3 was transformed to α-Al2O3 after microwave thermal reaction.
5.
2013.09 서비스 종료(열람 제한)
This paper attempted to estimate the emissions of HFC-134a from scrap truck as a result of measuring the residual quantities of HFC-134a in air conditioner of scrap truck. We measured the residual amounts in the scrap truck of 138 by applying commercial recover for refrigerants. The average residual rate(disposal-phase emission factor) is reported to be 44.3±3.3% within a confidence interval of 95%. Recent year model trucks exhibit the higher residual rates. Little variation, however, is observed in regard to vehicle size. The HFC-134a emission quantity from scrap truck in 2011 is estimated to be 55,908 tCO2-eq that demonstrates 21.4% increase to compare with that in 2007. As the numbers of truck have increased dramatically during the last two decades, the emissions of HFC-134a from scrap truck would increase sharply in the next coming years. HFC-134a is a very high GWP greenhouse gas. therefore have to reduce the emissions from the scrap truck and need to find ways to recycle. The chemical compositions of refrigerants from scrap truck are quite similar to those of new refrigerants, suggesting that the refrigerants from scrap truck could be reused as refrigerant.
6.
2013.09 서비스 종료(열람 제한)
The study area is located on the western coast, and the inner development construction has been ongoing since 2011. The purposes of current study are to effectively simulate and quantitatively predict a temporal and spatial distributions of water temperature and salinity due to the stages of inner development construction in saemangeum reclaimed area. The transient-state numerical modeling using EFDC model is done, and the numerical simulation results are validated reasonably by repetitive numerical model calibration procedures with respect to field measurements of water temperature and salinity. The spatial distributions of water temperature and salinity show similar trends before and after construction of the dikes. In spring season, the salinity has maximum value of 21 psu, while, in summer season, the salinity shows 7 psu in a whole modeling domain. Thus, it is clearly observed that salt water is replaced by freshwater. However, the salinity and temperature reach their initial conditions at the end of the year. The salinity after construction of the dikes is lower than that before construction of them at Mankyeong area. On the other hands, after construction of the dikes, the salinity after dredging operations is higher than that before dredging. Because drastical increasing of water volume in Saemangeum Lake leads to increasing of stagnation time at bottom layer, and salt water is easily intruded to the two estuaries. Therefore, it may be concluded that hydrodynamic characteristics on Saemangeum are dominated by either Mankyeong and Dongjin discharge or sluice gates in/out-flow amounts, and thus they must be properly considered when rigorous and reasonable predictions of water temperature and salinity according to the stages of inner development construction.
7.
2013.09 서비스 종료(열람 제한)
Desorption characteristics of VOCs were investigated for the effective recovery of gasoline vapor. The adsorption capacity and desorption capacity were excellent at relatively low temperatures. The differences in the desorption capacity were not large in the condition; desorption temperature 25℃, desorption pressure 760 mmHg, inlet air flow rate 0.5 L/min, but were relatively great in the condition; desorption temperature 0℃, desorption pressure 60 mmHg, inlet air flow rate 1.0 L/min. The desorption ability of pentane was increased to about 81.4%, and the desorption ability of hexane was increased to about 102%, also the desorption ability of toluene was increased to about 156.7% by changes of temperature, pressure, inlet air flow rate in the experimental conditions. The optimum desorption condition for the effective recovery of VOCs was in the conditions; desorption temperature 0℃, desorption pressure 60 mmHg, inlet air flow rate 1.0 L/min.
8.
2013.09 서비스 종료(열람 제한)
Insect fauna were surveyed in 2011 at Ungok wetland, Obeygol, located in Gochang, Jeonbuk, Korea. In total, 149 species belonging to 11 orders and 57 families were surveyed. Among them, Lepidopterans composed 23.5% (35 species) of the total insect numbers surveyed, comprising the most abundant group, and followed by Coleoptera, Hemiptera, and Odonata with a composition of 22.1% (33 species), 17.4% (26 species), and 10.1% (15 species), respectively. Bothrogonia japonica Ishihara was the most dominant species, and followed by Gastrophysa atrocyanea Motschulsky and Celastrina argiolus (Linnaeus). Phytophagous insects accounted for 60 percent of the total species. Dominance index was the highest in spring by 0.21. Diversity, richness, and evenness indices were the highest in summer by 4.07, 11.84 and 0.96, respectively. In the study area, the legally-protect species were grouped into five groups; 9 export-restricted species, 17 endemic species, 28 indicator species, 1 climate-sensitive biological indicator and 3 southern characteristic species. Additionally, twenty forest insect pest species were surveyed, belonging to 5 orders and 15 families. Therefore, it is required to conduct long-term monitoring and appropriate management based on the ecological characteristic of the habitats to continuously conserve and maintain of wetland.
9.
2013.09 서비스 종료(열람 제한)
While a range of natural organic matter (NOM) types can generate high levels of disinfection by-products (DBPs) after chlorination, there is little understanding of which specific compounds act as precursors. Use of eight model compounds allows linking of explicit properties to treatability and DBP formation potential (DBPFP). The removal of model compounds by various treatment processes and their haloacetic acid formation potential (HAAFP) before and after treatment were recorded. The model compounds comprised a range of hydrophobic (HPO) and hydrophilic (HPI) neutral and anionic compounds. On the treatment processes, an ozone oxidation process was moderate for control of model compounds, while the HPO-neutral compound was most treatable with activated carbon process. Biodegradation was successful in removing amino acids, while coagulation and ion exchange process had little effect on neutral molecules. Although compared with the HPO compounds the HPI compounds had low HAAFP the ozone oxidation and biodegradation were capable of increasing their HAAFP. In situations where neutral or HPI molecules have high DBPFP additional treatments may be required to remove recalcitrant NOM and control DBPs.
10.
2013.09 서비스 종료(열람 제한)
The efficiency of coal-based activated carbon in removing methylene blue (MB) and phenol from aqueous solution was investigated in batch experiments. The batch adsorption kinetics were described by applying pseudo-first-order, pseudo-second-order, and first order reversible reaction. The results showed that the adsorption of MB and phenol occurs complexed process including external mass transfer and intraparticle diffusion. The maximum adsorption capacity obtained from Langmuir isotherm was 461.0 mg/g for MB and 194.6 mg/g for phenol, respectively. The values of activation parameters such as free energy (△G˚), enthalpy (△H˚), and entropy (△S˚) were also determined as -19.0∼-14.9 kJ/mol, 25.4 kJ/mol, and 135.2 J/mol K for MB and 51.8∼54.1 kJ/mol, -29.0 kJ/mol, and -76.4 kJ/mol K for phenol, respectively. The MB adsorption was found to be endothermic and spontaneous process. However, the CV adsorption was found to be exothermic and non-spontaneous process.
11.
2013.09 서비스 종료(열람 제한)
Recent climate change has led to fluctuations in agricultural production, and as a result national food supply has become an important strategic factor in economic policy. As such, in this study, panel data was collected to analyze the effects of seven meteorological elements and using the Lagrange multipliers method, the fixed-effects model for the production of five types of food crop and the seven meteorological elements were analyzed. Results showed that the key factors effecting increases in production of rice grains were average temperature, average relative humidity and average ground surface temperature, while wheat and barley were found to have positive correlations with average temperature and average humidity. The implications of this study are as follow. First, it was confirmed that the meteorological elements have profound effects on the production of food crops. Second, when compared to existing studies, the study was not limited to one food crop but encompassed all five types, and went beyond other studies that were limited to temperature and rainfall to include various meterological elements.
12.
2013.09 서비스 종료(열람 제한)
Due to climate change, the occurrence of abnormal weather conditions has become more frequent, causing damage to vegetable crops grown in Korea. Hot pepper, Chinese cabbage and radish, the three most popular vegetables in Korea, are produced more in the field than in the greenhouse. It has been a trend that the time for field transplanting of seedlings is getting earlier and earlier as the spring temperatures keep rising. Seedlings transplanted too early in the spring take a longer time to resume the normal growth, because they are exposed to suboptimal temperature conditions. This study examined the influence of air temperature during seedling growth on the time required to reach the first fruit maturity and yield of hot pepper. Seedling plants of ‘Super Manita’ hot pepper was grown in temperatures 2.5℃ and 5.0℃ lower than the optimum temperature (determined by the average of temperatures for the past 5 years). Seedlings were transplanted into round plastic containers (30-cm diam., 45-cm height) and were placed in growth chambers in which the ambient temperature was controlled under natural sunlight. The growth of seedlings under lowered temperatures was reduced compared to the control. The mineral (K, Mg, P, N) concentrations in the leaf tissues were higher when plants were grown with the ambient temperature 2.5℃ lower than the optimum, regardless of changes in other growth parameters. Tissue calcium (Ca) concentration was the highest in the plants grown with optimum temperature. The carbohydrate to nitrogen (C/N) ratio, which was the highest (18.3) in the plants grown with optimum temperature, decreased concomitantly as the ambient temperature was lowered 2.5℃ and 5.0℃. The yield of the early harvested fruits was also reduced as the ambient temperature became lower. The first fruit harvest date for the plants grown with optimum temperature (June 27) was 13 days and 40 days, respectively, earlier than that in plants grown with 2.5℃ (July 10) and 5.0℃ (Aug 6) lower ambient temperatures. The fruit yield per plant for the optimum temperature (724 g) was the greatest compared to those grown with 2.5℃ (446 g) and 5.0℃ (236 g) lower temperatures. The result of this study suggests that the growers should be cautioned not to transplant their hot pepper seedlings too early into the field, since it may delay the time of first harvest eventually reducing total fruit yield.
13.
2013.09 서비스 종료(열람 제한)
The result of a small electrostatic precipitator which is in order to decrease indoor air pollution for optimal efficiency was shown as follows. Although the closer distance between the discharge electrode and dust collecting electrode shows the better throughput efficiency by forming strong electrostatic Field, it does not have profound impact in case of optimal dust collecting area. G.P(gas passage) which is the distance from dust collecting electrode to dust collecting electrode is a crucial factor to decide dust collecting efficiency. The narrower distance of G.P shows the better throughput efficiency whereas it decreases when the distance is too narrow since sparks ensue by increasing the capacity of electrostatic charging system 5 mm regards as optimal efficiency in this experiment. Although the higher voltage shows the higher dust collecting efficiency overall, the experiment was not able to keep performing since the sparks which decrease dust collecting efficiency ensue over 40 kV. The efficient and safe voltage state is considered 3.6 kV in this experiment. The most crucial factor for dust collecting efficiency of an electrostatic precipitator which is in order to decrease indoor air pollution is applied voltage. In addition, optimal raw gas flow rate(2.4 m/sec) is more important factor than the excessive increase of dust collecting area.
14.
2013.09 서비스 종료(열람 제한)
Mobile sources produce a significant fraction of total anthropogenic emissions in Korea and have harmful effects on air quality. Mobile emissions are intrinsically difficult to estimate due to complicated road networks and variations of traffic volume with location and time. To measure traffic pollutants with high temporal and spatial resolution under real conditions a mobile laboratory was designed. The mobile laboratory provide concentrations of SO2, CO, NO, NO2 and location coordinate value. This approach allowed for pollutant level measurements on many roads within short periods of time. In this study, on-road concentrations of SO2, CO, NO and NO2 were measured using mobile platform measurement along the 25 main roads in Busan to estimate the average air pollution level in short time difference. The measurements were conducted on favorable meteorological days from 2010 to 2012 and the overall concentrations of SO2, CO, NO and NO2 were 0.006, 0.8, 0.182 and 0.055 ppm respectively. The result showed that the concentration of CO, NO and NO2 on road were twice, 18 times and 2.5 times higher than regional air quality monitoring sites mean in same period.
15.
2013.09 서비스 종료(열람 제한)
PM10 concentration is related to the meteorological variables including to local and synoptic meteorology. In this study the PM10 concentrations of Busan in 2007~2011 were analyzed and the days of yellow sand or rainfall which is more than 5 mm were excluded. The sections of PM10 concentration were divided according to 10-quantiles, quartiles and 90-quantiles. The 90-quantiles of daily PM10 concentration were selected as high concentration dates. In the high concentration dates the daily mean averaged cloudness, mean daily surface wind speed, daily mean surface pressure and PBL height were low and diurnal variation of surface pressure and daily maximum surface temperature were high. When the high PM10 dates occurred, the west and south wind blew on the ground and the west wind blew strongly on the 850 hPa. So it seemed that long range transboundary air pollutants made effects on the high concentration dates. The cluster analysis using Hysplit model which is the backward trajectory was made on the high concentration dates. As a result, 3 clusters were extracted and on the short range transboundary cluster the daily mean relative humidity and cloudness were high and PBL height was low.
16.
2013.09 서비스 종료(열람 제한)
Between July and October 2011, radio-tracking was used to analyze the characteristics of home ranges and day roosts of Myotis aurascens by using 3 individuals (male: 2, female: 1). Bat capturing was conducted at a bridge and a nearby forest in Ulju-gun, Ulsan-si. We attached radio transmitters (0.32 g) to the bats and monitored them by using a radio receiver with a Yagi antenna. Home-range analysis of M. aurascens by using 100% minimum convex polygon (MCP) and 95% MCP showed an average of 106.5 ha and 89.3 ha, respectively, and 50% kernel home range (KHR) showed an average of 8.4 ha. Home range overlap of the 3 bats was observed at the bridge and at nearby water bodies as the core areas, and the size of the home range overlap was 7.3 ha by 100% MCP, 5.9 ha by 95% MCP, and 1.6 ha by 50% KHR. The home range for each bat consisted of the main foraging sites, and the types of foraging sites were similar. M. aurascens-01(M-01) used the bridge and nearby water bodies as the nightly main core areas, M. aurascens-02(M-02) used rice fields and water bodies adjacent to the forest as core areas, and M. aurascens-03(M-03) used water bodies and resident areas as core areas. Although rice fields and resident sites represented the core areas of the home ranges of M-02 and M-03, habitat use was the highest near water bodies as the core area for all the 3 bats. The types of day roosts in this study were a wooden house, canopies of a broad-leaved woodland, and banks of rice fields. The roosts in the wooden house and canopies of the broad-leaved woodland were located within the forest, and the roost in the banks of rice fields was also adjacent to the forest. Our results revealed that the main home range and foraging sites of M. aurascens were located near water bodies as the core area, and forests and places adjacent to the forests were used as day roosts.

RESEARCH NOTE

17.
2013.09 서비스 종료(열람 제한)
The effects of probiotic additions to feed and manure on temperature, humidity and carbon dioxide (CO2) emissions in Hanwoo manure during summer (4 weeks) were evaluated. Fifteen Hanwoo (24-mo-old, 580 ± 20 kg) were housed in individual pens (5 × 8 m) and randomly assigned to 1 of 3 treatments (n = 5 cattle per treatment). Hanwoo were fed experimental rations as follows: control (10 kg roughage + 2 kg concentrate); T1 (10 kg roughage + 2 kg concentrate, 2% probiotics on as-fed basis); and T2 (10 kg roughage + 2 kg concentrate, 2% probiotics on as-fed basis + 7 kg probiotics as top-dressing on the surface of Hanwoo manure). In comparison to the control, the addition of probiotics to feed or feed and manure had an effect (P < 0.05) on temperature and humidity over the 4 weeks, except for humidity at 0 weeks. The only significant difference (P < 0.05) observed in CO2 emission was among all treatments at 3 and 4 weeks (but not at 0 through 2 weeks). These results indicated that use of probiotics as feed and manure additives did not have a significant effect on environmental parameters.