간행물

한국환경과학회지 KCI 등재 Journal of Environmental Science International

권호리스트/논문검색
이 간행물 논문 검색

권호

제14권 제6호 (2005년 6월) 12

1.
2005.06 서비스 종료(열람 제한)
We introduce a simplified crossing wood drain disperses rain water concentration and is used to protect the road surface from erosion due to flooding over the unpaved road. The efficiency of a simplified crossing wood drain was also investigated. A structure of simplified crossing wood drain can be produced within 10 minutes and installed within 18 minutes. The cost of the this product is 1/5 of that of the existing crossing drain product. The production and installation cost can be reduced according to dexterity. In the context of such applications, the degrees of damage for a rubber pad, which preventing the rain overflow, were varied according to their materials. A type of 8.2㎜ thick fabric rubber was the most suitable in this study.
2.
2005.06 서비스 종료(열람 제한)
Polyelectrolyte titration, which was called colloid titration is based on the stoichiometric reaction between oppositely charged polyelectrolytes. This can be used, for instance, to determine the charge density of a cationic polyelectrolyte, using an anionic polyelectrolyte of known charge density, such as potassium polyvinyl sulfate (PPVS). The technique requires a suitable method of end-point detection and there are several possibilities. In this work, two methods have been investigated: visual titrimetry based on the color change of a cationic dye (o-toluidine blue, o-Tb) and spectrophotometry based on the absorbance change corresponding to the color change of the same dye. These have been applied to several cationic polyelectrolytes with different charge density and molecular weight. In all cases, the cationic charge was due to quaternary nitrogen groups. In the case of cationic dye, it was shown that the sharpness depends on the charge density of cationic polyelectrolyte. With the polyelectrolytes of lower charge density, the binding to PPVS is weaker and binding of the dye to PPVS can occur before all of the polyelectrolyte charge has been neutralized. However, by carrying out titrations at several polyelectrolyte concentrations, good linear relationships were found, from which reliable charge density values could be derived. Effects of pH and ionic strength were also briefly investigated. For cationic polyelectrolytes (copolymers of acrylamide and dimethylaminoethyl acrylate), there was some loss of charge at higher pH values, probably as a result of hydrolysis. Increasing ionic strength causes a less distinct color change of o-Tb, as a result of weaker electrostatic interactions.
3.
2005.06 서비스 종료(열람 제한)
In this study, an optimization technique was developed from the application of Allocation Rule. Average Allocation coefficients of the Andong and Imha dam compare constant water supply condition with vary water supply condition that are above the contribute ratio 67%~50% the Andong dam in Rule(A)~Rule(C). In the Refill Season, Andong dam water supply contribution is higher than Imha dam at the Control point water supply. In the Allocation analysis results, Rule(A) is calculated storage ratio because Andong dam contribute to Control point larger than Imha dam which Andong dam storage is larger than Imha dam storage. Rule(B) calculated sum of the storage and inflow ratio for Andong dam and Imha dam, as Andong dam contribution is higher than Imha dam. Rule(C) calculated that sum of storage, inflow and water supply is divided average storage ratio, as the best results of the Allocation coefficients and water supply capacity. The results of storage analysis is larger vary water supply condition than constant water supply condition and the results of water supply analysis is larger vary water supply condition than constant water supply condition. Water supply deficit is decrease 30% for vary water supply condition.
4.
2005.06 서비스 종료(열람 제한)
In recent days, photochemical smog due to the rapid industry development and vehicle increasement has become a critical pollutant in the metropolitan area and the number of ozone alarm signal has increased every year. This research was performed to evaluate VOCs emission source characteristics and concentration of VOCs in Daegu. The site average concentration was observed in the following order : industrial area > commercial area > residential area. Most of the VOCs species except toluene showed variations with higher concentration during nighttime, and lower concentration during the daytime. The major VOCs of stationary emission source were BTEX(benzene, toluene, ethylbenzene, xylene) and methylene chloride, trichloroethene and styrene. Also, those of automobile exhaust were toluene and benzene. Also, the major VOCs concentration emited by the vehicle fuel was observed in the following order : gasoline > light oil > liquefied petroleum gas (L.P.G). Correlation coefficients values were estimated between major VOCs such as toluene, ethylbenzene, m,p-xylene, o-xylene. Results showed that correlation coefficient values were significant magnitude above 0.76. Also, there showed highly significant correlations among ethylbenzene, m,p-xylene, and o-xylene concentration(Pearson correlation coefficients, r= 0.868~0.982). Calculated correlation coefficients among commercial area, industrial area and residential area were 0.934~0.981, they showed high correlation. There showed highly correlation between stationary emission source and industrial area, compared with commercial area and residential area. Also, calculated correlation coefficients among commercial area, industrial area, residential area and automobile exhaust were 0.732, 0.725, 0.777, respectively.
5.
2005.06 서비스 종료(열람 제한)
This study presents the characteristics of nocturnal inversion layer and their effect on the concentration variations of surface air pollutants using tethersonde and automatic weather station (AWS, 2 layer tower) system in Ulsan during 2003. The method for the distinction of inversion intensity was decided based on the sum of nocturnal temperature gradient. As the results, there was a close correlation (correlation coefficient of 0.76) between the maximum inversion height obtained from tethersonde and the sum of nocturnal temperature gradient. The air pollutant concentration was also directly proportional to the inversion intensity. When the inversion intensity was strong in the nighttime, ozone (O3) concentration was lower, while nitrogen dioxide (NO2) concentration was higher. The carbon monoxide (CO) concentration was gradually higher according to the nocturnal inversion intensity, whereas sulfur dioxide (SO2) concentration was relatively constant. In addition, we found that there was no correlation between the inversion intensity and TSP concentration.
6.
2005.06 서비스 종료(열람 제한)
The characteristics for the aerosol number distribution was studied during spring, 2004 in Incheon. Optical Particle Counter (OPC, HIAC/ROYCO 5230) was used in order to measure the number concentration of aerosol in the range of 0.3~25㎛. The obtained results were compared with PM2.5 and PM10 data during Asian dust events. The results show that the size resolved aerosol number concentration from OPC measurement has a similar tendency with PM10 and PM2.5 mass concentration. During Asian dust periods, the number concentrations in large particle (CH5~CH8) increase more than small particles which diameter is less than 2.23㎛(CH5) and the same results were shown when PM10 was compared with PM2.5 data compared with non-dust days, Consequently, this study shows that size resolved aerosol number concentration from OPC measurement can be used as a useful tool in comparison of mass concentration data.
7.
2005.06 서비스 종료(열람 제한)
Enormous apartment complexes in urban areas, temporary inversion state and heat island effect occur due to the strong sunshine and weak wind speeds which hinders the dispersion of air pollutants that are emitted from neighboring areas of apartment complexes. In this study, analysis were conducted by using the Fluent code based on the CFD(Computation Fluid Dynamics), including building layout, material, building height from the ground surface, the heat, analysis of flow field in the apartment complex. It was estimated that the temporal radiation inversion phenomenon during the daytime, which was caused by the weak wind speed and higher temperatures in the upper level, contributed to the stagnation of the air pollutants in the lower layer of the apartment complex.
8.
2005.06 서비스 종료(열람 제한)
Samples of water, soil, and sediment were taken from 10 streams of Andong city in Gyeongbuk province in October 2004. To assess the degree of environmental pollution for each stream site, the chemical analyses of pollutants such as T-N, T-P, COD, heavy metal, organophosphorous and organochlorine pesticides, and dioxin-like PCB congeners were implemented using the standard process tests or the U. S. EPA methods. In addition, biological assessment using insect immune biomarkers was conducted on the same environmental samples to complement the chemical assessment. Except Waya stream (T-N; 2.91 mg/L, T-P; 0.16 mg/L, COD; 14.0 mg/L) with above the environmental quality standards, the T-P and COD concentrations of 9 sites are relatively low. The contents of Pb and Cd in samples taken from each stream were much lower than environmental quality standards. However, in comparison with soil samples of other streams, several times higher concentrations of Pb and Cd were found in locations at Mi, Gilan, Yeonha, and Waya stream sites. Dementon-S-methyl, diazinon, parathion, and phenthoate compounds among organophosphorous pesticides were detected as concentrations of ppb levels, respectively, from soil samples collected in the vicinity of Gilan, Mi, Norim, and Waya stream. On the other hand, 16 organochlorine pesticides and 12 dioxin-like PCB congeners selected in this study were not found in all samples. In particular, considering significant disrupting effects of Waya stream's samples on insect immune capacity, this stream seems to be contaminated with investigated and/or uninvestigated pollutants in this study.
9.
2005.06 서비스 종료(열람 제한)
In this study, we try to determine the distributive property in southwest coastal waters, such as Kwang-yang bay, Ka-mak bay, Yeo-ja bay, Wan-do, Hea-nam, Young-gwang, and Mok-po, using simultaneous analytical method of 310 chemicals. The results were detected tens of the organic pollutants in sampling sites, and the major chemicals detected were CH type chemicals such as aliphatic, polycyclic compounds and were CHN(O) type chemicals such as aromatic amines, nitro compounds. In particular, pesticides were mainly detected in summer, phenols and phthalate esters were not seasonal effect. Also, a number of aromatic chemicals were detected in Kwang-yang bay. From the results of this study, we confirmed that it is mainly contaminated in summer and the pesticide chemicals are the major pollutants in southwest coastal waters.
10.
2005.06 서비스 종료(열람 제한)
The aim of this study was to analyze the local distribution of the heavy metal concentration in Daegu and Ulsan which were divided into the residual areas, the traffic dense areas and the industrial areas. The Inductively Coupled Plasma(ICP) was used to analyze heavy metals, such as As, Cr, Hg, Zn, Cd, Pb, Cu and minor metals, such as Fe, Si, Mg, Ca, Al, Na, K. The results of this analysis showed that the content of heavy metals which was classified by districts in Daegu and Ulsan was the highest in the industrial areas followed by the traffic dense areas and the residual areas. Compared to the level of heavy metals of national and local soil survey network in 2003, contamination of heavy metals in Daegu was lower than national average. However, the content of Cd, As, Zn in Ulsan was respectively 13.38 times, 472 times and 2.65 times higher than national average contamination. In addition, compared to the soil pollution level of the environmental protection law, contamination of all areas in Daegu was lower. But the content of As at the industrial areas in Ulsan was 10.71 times higher than standard of soil pollution and 4.28 times higher than standard of measures against soil contamination.

연구노트

11.
2005.06 서비스 종료(열람 제한)
Recently, we are suffered enormous loss from a natural disaster and making an effort to prepare measures for dealing with disasters. This study shows the major causes of natural disasters and stricken area with the analysis of meteorological data based on the Korean Meteorological Administration and the Central Disaster Relief Center records during 1987-2003 and classifies natural disasters according to the causes and damaged conditions. In this study, the most damaged area were Gangwon, Gyeongnam and Gyeongi province as a result of a typhoon and a localized heavy rain. To establish an effective disaster measure for these area, detailed prevention plans should be established by its causes after investigating precise regional damage data analysis.
12.
2005.06 서비스 종료(열람 제한)
It is analysised the causes and extent of damage of natural disasters through the investigating of natural disaster states occurred in Gyeongsangnam-do. The data for this study were based on disaster annual report between 1987 and 2003. Especially, the data between 1993 and 2003 were used for the analysis in Gyeongsangnam-do area. A typhoon and a heavy rain were the major causes of the natural disasters in Gyeongsangnam-do. For all that the extent of damage by a heavy rain was twice as much as that of a typhoon, Gyongsangnam-do suffered heavy damage from a typhoon. So, special attentions should be paid to establish prevention plans for that in this area. Also, half of the natural disasters were occurred between July and August, the intensive prevention plans for the summer season are needed.