This research proposes an optimal flushing operation technique in an effort to prevent secondary water pollutions and accidents in aged pipes, and to improve the cleaning effect of unidirectional flushing. Water flow directions were analyzed using EPANET 2.0, while flushing and air scouring experiments in forward and reverse directions were performed in the field. In 42 experiments, average residual chlorine concentration and turbidity were improved after cleaning compared to before cleaning. It was found that even when the same cleaning method was used, further improvement of cleaning effect was possible by applying air injection and reverse direction cleaning techniques. By means of one-way ANOVA(Analysis of variance), it was also possible to statistically verify the need of actively utilizing air injection and reverse direction cleaning. Based on correlation between turbidity and TSS, the total amount of suspended solids removal was estimated for 874 flushing operations and 194 air scouring operations. The result showed that air scouring used more discharge water than flushing by an average of 4.9 m3 yet with larger amounts of suspended solids removal by an average of 145.9 g. The result of analysis on turbidity values from 887 flushing operations showed low cleaning effect of unidirectional flushing for the pipes with diameters over 300 mm. In addition, the turbidity values measured during cleaning showed an increasing tendency as pipe age increased. The methodology and results of this research are expected to contribute to the efficient maintenance and improvement of water quality in water distribution networks. Follow-up research involving the measurement of water quality at regular time intervals during cleaning would allow a more accurate comparison of discharge water quality characteristics and cleaning effects between different cleaning methods. To this end, it is considered necessary to develop a standardized manual that can be used in the field and to provide relevant trainings.
본 연구는 공기주입 이중피복온실과 관행 이중피복온실의 생육환경과 단열성능을 비교하기 위하여 수 행하였다. 두 온실의 온도, 상대습도, 포차, 이산화탄소농도, 일사량, 딸기 생산량 및 난방연료소비량을 비교하 였다. 공기주입온실이 관행온실보다 야간에 상대습도가 더 높고 포차는 더 낮게 나타나 딸기의 생육에 좋지 않은 환경을 보여주었다. 이산화탄소농도는 공기주입온실이 관행온실보다 더 높게 나타났으며, 이는 공기주입 온실이 더 밀폐되어 있어 환기량이 적기 때문인 것으로 판단된다. 관행온실의 광투과율이 77%로 공기주입온실 의 72%보다 더 높아 관행온실의 광환경이 더 우수한 것으로 나타났다. 관행온실의 딸기 생산량이 더 높게 나 타났으며, 이는 관행온실의 생육환경이 공기주입온실보다 더 우수한 결과로 판단된다. 난방연료는 공기주입온 실에서 더 적게 소모되어 공기주입온실의 단열성능이 더 우수한 것으로 나타났다.
분리막 오염을 감소시키고 투과유속 향상을 위하여 관형분리막 모듈 내에 공기 분사노즐관을 삽입시켰다. 분리막 의 평균 기공크기는 0.1 μm이며 이스트를 오염물질로 사용하였다. 모든 투과실험은 노즐관을 모듈에 장착하고 공기를 주입 하지 않는 실험을 먼저 실시하고 연속해서 공기를 주입하는 투과실험을 하였다. 그 다음 노즐관을 제거한 후 공기를 주입시 키지 않으면서 투과유속을 측정하였다. 측정된 투과유속은 공기주입 효과를 분석하기 위하여 비교하였다. 공기주입에 대한 투과유속은 거의 일정하거나 증가하였다. 노즐관이 장착되고 공기 주입을 하지 않을 경우의 투과유속이 빈 관형 모듈의 경우 보다 높았다. 운전압력을 0.4 bar까지 감소시키면 노즐관이 장착되지 않는 경우와 비교하여 공기를 주입할 경우 투과유속이 21%까지 향상되었다. 기체량이 증가하여 기/액체 2상 흐름이 stratified-smooth에서 intermittent 상태로 변화됨에 따라서 공기 주입에 의한 투과유속은 30% 이상으로 증가하였다
현재, 하수처리분야에서 MBR 공정은 대부분 침지식 분리막에 의존하고 있다. 하지만, 실제 적용현장에서는 유지관리 및 막오염 제어의 어려움 그리고 낮은 처리 flux로 인해 대안이 필요한 실정이다. 본 연구에서는 이러한 침지식 MBR의 문제점을 보완하고자 가압식 분리막을 이용한 85m3/일 규모의 MBR 공정을 구성하여 운전 특성을 고찰하였다. 슬러지 원천감량 기술을 결합한 가압식 MBR공정은 분리막 내부로 MLSS와 공기를 동시에 주입함으로써 40~50 LMH의 높은 여과 성능을 나타냈을 뿐 아니라 약 60%의 잉여슬러지 감량효과도 보여 주었다.
Deposits discharged through the cleaning mainly were cement mortar, bitumen paintings and rust pieces, and fragments of perforation, stones and gravels. Deposits were more removed through swabbing pig cleaning rather than air scouring cleaning on the whole. However, air scouring cleaning were not influenced by the constraint conditions such as a change in the diameter or the presence of the valve in water mains compare to swabbing pig cleaning. So, it was thought that air scouring cleaning might be more favorable to water distribution network cleaning in the future. After the cleaning, water quality including residual chlorine and turbidity also was improved because of the removal of a significant amount of the deposits. Therefore, if the cleaning is continuously and regularly implemented in water mains, it is expected that it will help to recover the reliability and to preserve the health of water quality.
In recent years, there was many conflagration about special structure such as wooden cultural assets, warehouses and factories. The common causes of increase in the fire damage were difficulty of the initial suppression and absence of equipment for appropriate disaster prevention. A prediction of the air injection diameter of the destruction-spray nozzle, a core technology of destruction-spray fire vehicle which is possible for fire suppression of special structure were studied. As a result, changes in water flow according to the air injection diameter is not large, but air flow rate showed a difference more than up to four times. And then, through the result data of the flow analysis, the air injection diameter was obtained in the target mix ratio of the air according to the water injection pressure. Finally, by the formula derivation for the air injection diameter of target mix ratio of the air, the air injection diameter according to the water injection pressure change could be predicted within an error of 10%.
지표관수와 비교하여 지중관수 및 지중관수 시 공기주입의 효과를 검토하고자 '녹광' 풋고추를 온실 내에서 토양재배(silty loam)하여 관수효율, 토양특성, 과실 생육 및 수량 등을 조사하였다. 관수방법은 관수호스를 이랑당 2열 배열하되 지표관수는 토양표면, 지중관수는 지표 20cm 아래에 설치하였고, 공기주입은 air compressor를 이용하여 낮 동안에 시간당 3분간 주입하였다. 관수는 콘트롤러, 전자식 토양수분장력센서 등을 이용, 토양수분에 기초한 자동관수를 실시하였는데, 관수개시점은 -20kPa, 관수종료점을 -10kPa로 설정하여 관리하였다. 그 결과, 토양수분의 감소속도가 지표 관수에 비해 지중관수와 지중관수 +공기주입이 늦었으며, 관수량도 지중관수가 지표환수에 비해 지표면에서의 증발 감소 등으로 약 30% 적었다. 표토층의 EC 및 무기이온함량은 지표관수에 비해 지중관수나 지중관수 +공기주입이 낮은 수준이었다. 뿌리의 발달은 지표관수에 비해 지중관수+공기주입한 것이 가장 좋았는데, 특히 뿌리가 길고 세근의 발달이 많았다. 이로 인해 풋고추 수량이 지표관수에 비해 지중관수가 22%, 지중관수 +공기주입이 30% 각각 증가되었다.
본 연구는 우리나라의 기상환경에 적합한 한국형 공기주입 이중피복 플라스틱 온실을 설계하는데 필요한 기초자료를 제공하기 위하여 실험용 공기주입 이중피복 플라스틱 온실을 제작하여 작동실험을 실시하고 온실내부의 환경변화를 분석하였다. 온실의 피복재를 설치할 때 시공기술이 부족하여 밀폐도가 많이 떨어지는 것으로 나타났기 때문에 이중피복 공기충의 정압을 적절하게 유지하기 위해서는 높은 밀폐도를 유지할 수 있는 피복재 설치기술과 관련 자재의 개발이 요구되었다. 관행의 이중피복온실보다 공기주입 이중피복온실이 단열효과가 더 우수하였으며, 특히 아치형 지붕형태의 공기주입 이중피복온실이 복숭아 형태의 관행온실에 비해 2℃ 정도 높아 보온효과가 상당히 우수한 것으로 나타났다. 시공성이 우수하고 밀폐도를 높일 수 있는 피복방식은 온실위에 피복재를 덮은 상태에서 여유길이를 두지 않고 자연스럽게 고정시키는 것이 가장 바람직하였다. 다른 조건들이 동일한 공기주입 이중피복 단동온실의 경우 복숭아형 지붕온실에 비해 아치형 지붕온실에서 광투과율이 더 높은 것으로 나타났다. 3연 동 온실의 경우에는 관행 이중피복온실에 비해 공기주입 이중피복온실이 광투과율이 더 높은 것으로 나타났으며, 이는 주로 골조율과 이중피복재간의 간격 때문인 것으로 판단되었고, 이에 대한 자세한 원인은 앞으로 추가적인 실험을 통해 검증할 예정이다. 결로의 발생현상을 가시적으로 비교한 결과 관행온실에서 더 많은 결로가 발생함을 확인할 수 있었다 그러나 정량적인 비교를 위해서는 장기간의 관측과 이론적인 분석이 필요할 것으로 판단되며, 향후 더 자세한 실험을 통해 규명할 예정이다.
본 연구의 목적은 침지형(YEF 750D-2) 모듈을 적용하여 공기유량에 따른 유체 유속과 간헐적인 세정공기의 공급에 의한 오염제거를 평가하는 것이다. 공기유량에 따라 모듈의 유체 유속은 선형적으로 증가하였으며, MLSS의 농도가 1,000 mg/L 증가할 때 마다 3times10-4m·min/sec·L 수식 이미지의 비율로 유체 유속이 감소하였다. 세정공기의 공급이 정지되는 시간에 전여과가 일어나 흡인여과 시간 동안 겔층 위에 케익층이 형성되었다. 20초 정지와 20초 공기공급의 간헐공기주입으로 형성된 케익층이 역세정에 의하여 제거되면서 압력증가율이 가장 낮게 나타났다. 겔층이 제거되는 메커니즘은 세정 공기공급을 교대로 하여 겔층 위에 케익층을 형성시켜 케익층이 제거될 때 겔층이 함께 제거되는 원리로 설명할 수 있다.
우리나라의 메탄가스 배출량은 2014년 기준 26.6백만톤 CO2eq 수준으로, 이중 약 27% (7.3 백만톤 CO2eq)는 폐기물매립지에서 유출되고 있다. 매립지에서의 메탄유출을 저감하는 가장 이상적인 방법은 매립가스를 포집하여 에너지화하는 “매립가스 자원화” 방식이다. 그러나, 이를 위해서는 가스포집시설, 가스정제시설 및 발전설비 등의 설비투자가 필요하며, 매립가스 발생량이 2~3 N㎥/min (메탄가스 농도 35%~50%)이상의 대규모 매립지에서만 경제성 확보가 가능하다고 알려져 있다. 이런 이유로 230개소의 매립지 중 17개 시설에서만 매립가스 자원화 시설을 운영하고 있으며, 대부분의 중소규모 매립지에서는 메탄유출에 대한 별다른 대책이 없는 실정이다. 본 연구에서는 중소규모의 매립지 5개소를 선정하여 “공기주입을 통한 호기성 매립지 전환” 및 “매립지복토층을 이용한 생물학적 메탄산화 기술”의 메탄저감 성능과 경제성을 검토하였고 “매립가스 자원화”와 비교하였다. 매립가스 자원화를 검토하기 위한 매립가스 발생량은 LandGem 모델을 이용하여 산정하였으며, 폐기물의 성상(메탄잠재발생량 및 메탄발생속도추정)및 매립량은 환경부 통계자료를 이용하였다. 공기주입에 따른 호기성전환 비율은 주입압에 따른 유효반경을 산정하여 추정하였으며, 복토층에서의 메탄산화 효율은 문헌조사를 통해 결정하였다. 기술검토 결과 공기주입과 복토층 메탄산화기술을 조합하는 경우 70~85% 수준까지 메탄유출을 저감할 수 있는 것으로 추정되었으며, 중소규모 매립지의 경우 매립가스 자원화와 비교하여 상대적으로 우수한 경제성을 나타냈다.
Because methane-producing bacteria (MPB) and sulfate-reducing bacteria (SRB) compete for anaerobic utilization of organic matter, the methane generation potential (Lo) decreases logarithmically with the decrease in the COD/SO4 ratio. The Lo correction coefficient equals the Lo at a particular COD/SO4 ratio divided by the maximum Lo. An Lo correction coefficient was derived each year based on the COD/SO4 ratios of waste added to the landfill. The methane generation potential was multiplied by the Lo correction coefficient in order to correct the LFG (landfill gas) generation calculation. At the second Sudokwon landfill site (2000 ~ present), the COD/SO4 ratio decreased from 11.6 in 2000 to 4.8 in 2014. Thus, the Lo correction coefficient decreased from 0.89 in 2000 to 0.42 in 2014. The LFG 2008-2014 production correction was calculated using the model equation (Scholl canyon), and was almost the same (91 ~ 113%) as the quantity measured, including LFG that was collected, flared, or allowed to diffuse through the landfill. The methane oxidation correction factor, calculated from the concentrations of nitrogen and oxygen within the landfill gas, was between 0.92 and 1 for the first landfill site and between 0.96 and 1 for the second landfill site. Air ingress into the landfill had a negligible effect on gas generation.
최근 에너지절약 및 대체 에너지 자원 확보, 환경보호 등의 관점에서 안정적이고 친환경적인 신․재생에너지에 대한 관심이 증가하고 있으며 그 일환으로 지열에너지 이용에 대한 관심도 높아져, 국내에서는 2000년경부터 지열의 활용이 이루어지기 시작했다. 특히 열펌프(Heat pump)의 개발 및 발달로 저온의 열에너지 활용이 가능하게 되면서 다양한 열원을 대상으로 열에너지가 활용되고 있다. 열펌프 시스템은 다양한 열원을 적용하여 저급의 에너지를 냉난방이나 급탕 등의 고급에너지로 변환시키는 대표적인 고효율 에너지 기기이다. 열펌프를 이용하여 얻어지는 에너지 효율은 결국 열원측에서 얻을 수 있는 열원의 온도에 따라 결정되는데 주로 공기, 수열, 그리고 지열 등의 열원이 적용되고 있다. 이에 최근에는 하수열, 소각시설 등 환경기초시설 내의 미활용 열원을 대상으로 한 열펌프의 적용사례가 보고되고 있으나, 폐기물매립지의 경우에는 관련 연구가 미흡한 실정이다. 이에 본 연구는 폐기물매립지 내부로 공기 주입 시 발생하는 가스를 열원으로 한 열펌프의 적용 가능성을 평가하기 위한 기초연구로서 호기성 매립지 열원 회수 시스템을 실제 폐기물매립지에 설치 후 현장 실험을 하여 시스템 성능을 평가하고자 하였다. 본 연구 대상 매립지인 A 위생매립지는 경상북도에 위치한 계곡형 매립지(매립면적 56,500 m², 매립용량 1,278,000 m³)이며, 공기주입을 통한 추출가스 열 에너지의 이용 가능성을 평가하기 위해 호기성 안정화 장치, 열펌프, 축열조로 구성된 시스템을 설치하였다. 대상 매립지에 설치된 호기성 안정화 장치는 송풍기, 공기주입용 수직정, 가스 추출정, 바이오필터 등으로 구성되어 있다. 공기주입량은 100 m³/h이며 바이오필터에 투입되는 가스 추출량은 공기주입량과 동일하게 하였다. 가스 추출정은 공기주입정과 5m 거리를 두고 설치하였다. 매립지에서 추출된 가스는 열펌프의 부식을 방지하기 위해 바이오필터(우드칩)를 통해 암모니아와 황화수소를 제거된 후 열펌프에 투입되도록 하였다. 열펌프에 투입된 추출가스는 우선 증발기에서 냉매(R407)와 열교환을 통해 열에너지를 뺏기게 되며, 열을 흡수한 고온저압의 냉매는 압축기를 통해 고온고압의 상태가 된다. 이후 응축기를 거치면서 축열조로 순환하는 물과 열 교환하여 열에너지를 물로 전달하고 열을 빼앗긴 냉매는 저온고압의 상태로 팽창펌프로 들어가 저온저압의 상태가 되어 다시 증발기로 순환하게 된다. 축열조는 열펌프로 얻어지는 열에너지를 저장하는 것으로 물이 순환하여 열에너지를 저장하며 열펌프의 순환이 계속될수록 축열조의 온도는 상승하게 된다. 열펌프의 용량은 3 RT(Refrigeration ton)이며, 가스-냉매-물 방식이다. 실험결과 추출가스의 온도는 30-39℃를 나타났으며, 증발기에서는 평균 7.63 kW, 응축기에서는 평균 10.18 kW의 열량을 흡수하여 외기온도에 따라 증발기와 응축기 내에 유・출입되는 유체의 온도는 변화하였지만 안정적으로 열량을 흡수한 것으로 나타났다. 전력은 평균 3.1 kW가 소비된 것으로 나타났다. 열펌프의 난방성능계수(Coefficient of performance, COP)는 평균 3.2로 열펌프에 전력 1 kW 소비 시 3.2 kW의 열량을 발생시키는 것으로 나타났다. 기존 공기열원 열펌프는 외기온도가 낮은 동절기에는 COP가 낮아지는 문제점이 있으나 호기 성매립지의 경우에는 동절기에도 가스의 온도를 일정하게 유지시킬 수 있기 때문에 외기온도 저하에 따른 COP저하는 크지 않을 것으로 판단된다.
Heat is generated from decomposition of wastes as a result of chemical and biological processes in aerated landfills. The purpose of this study was to assess temperature and predict its variations in an aerated landfill. In the phase of aeration, temperature was increased slightly from 30 to 34oC until 65 days and then increased significantly from 34 to 74oC by termination of aeration. It indicates that the amount of oxygen supplied in the starting phase of aeration was insufficient to decompose organic carbon because oxygen supplied in the landfill was only consumed for methane oxidation. Additionally, to minimize the risk of self-ignition, drying and process inhibition, aerated landfills should be operated in a temperature range of 54 ~ 66oC through cooling by water addition and terminating or excessive oxygen supply. In this study, a stoichiometric modeling approach considering methane oxidation and decomposition of organic carbon has been suggested for predicting temperature variations in aerated landfills. As a result, the predicted temperature variations obtained the stoichiometric modeling led to similar results compared with measured temperature in aerated landfill. Therefore, it showed that the stoichiometric approach was appropriate for predicting temperature variation in aerated landfills. In addition, heat generation rates for methane oxidation and decomposition of organic carbon were 89.5 and 387.8 MJ/m3·yr, respectively.
경제성장과 급격한 산업화는 생활수준을 향상시켰으며 인구증가와 맞물려 세계적으로 물 사용량을 증가시켰고 결과적으로 하수슬러지의 발생량을 증가 시켰다. 국내의 하수도보급률을 85%를 상회하며 이로 인해 발생되는 하수슬러지의 양은 2006년 2,717,790 톤/년에서 2013년 말 기준으로 3,995,290 톤/년으로 3배가량 증가하였으며 하수슬러지의 양은 지속적으로 증가할 것으로 예상된다. 하수슬러지를 처리하기 위해 선진국에서는 육상 처리를 전제로 여러 가지 처리 기술들을 개발하고 있으며 국내에서도 여러 가지의 처리 방법이 연구되고 있는 상황이다. 하수슬러지를 처리하는 방법으로는 매립과 해양투기 이외에 소각, 용융, 탄화, 퇴비화, 시멘트 자원화 등의 여러 기술 등이 있다. 하지만 기술적, 경제적인 이유로 국내에서는 쉽게 적용되지 못하고 있는 실정이다. 이러한 문제를 해결하기 위하여 환경부에서는 공공하수처리장의 혐기성 소화조 효율을 향상시킴으로서 하수슬러지의 감량화를 통한 바이오가스의 생산량 증대를 위한 다양한 전처리 기술들이 연구되고 있다. 혐기성 소화단계는 가수분해, 산생성, 초산생성, 메탄생성 단계로 구분되어 있으며 이 중 가수분해 단계는 혐기성 소화의 율속 단계로서 혐기성 소화 전체 과정의 소화효율과 속도를 조절한다. 따라서 본 연구에서는 공기주입과 영가철(ZVI)을 이용한 산화 반응을 이용하여 하수슬러지속 세포벽을 파괴시켜 세포내의 각종 유기물을 용출시킨 후 가수분해 단계 촉진을 위한 가용화를 이용한 전처리 공정을 적용하고자 한다. 실험방법으로 슬러지 1kg 당 0.015 L/hr의 사전 공기 주입 후 0.1%, 0.5%, 1%, 1.5%, 2%, 3%의 영가철(ZVI)을 투입하여 전처리를 실시한다. 전처리 실시 후 실험결과 가용화율은 영가철(ZVI) 1.5% 투입시에 85%까지 상승하였으며 2% 투입 이후 부터는 더는 증가하지 않았다. 이를 통하여 산소주입과 영가철(ZVI)을 이용한 전처리가 하수슬러지의 가용화에 효과가 있는 것으로 나타났으며, 최종적으로 바이오가스 생산량 증가에 효과가 있을 것으로 판단된다. 향후 추가실험을 통해 하수슬러지의 오염부하의 저감 가능성을 평가하고 공기주입과 영가철(ZVI)을 이용한 전처리가 바이오가스 생성에 방해가 되는 H2S의 생성 억제에 미치는 영향에 대하여 연구하고자 한다.
2011년말 기준으로 공공하수처리시설은 505개소로 2001년 184개소, 2010년 470개소 등 지속적으로 증가하고 있으며, 이에 따라 하수처리시설에서 발생하는 슬러지량도 증가하고 있다. 슬러지를 처리하는 방안으로 고화, 매립, 해양배출, 혐기성 소화 등의 방법이 있으나, 고화 및 매립은 2차 환경오염에 대한 우려가 있고 해양배출은 2012년부터 전면 금지되었다. 이에 환경부에서는 공공하수처리시설에 설치된 혐기성 소화조의 효율 개선사업을 통해 소화효율을 향상시켜 메탄의 생산량 증대와 슬러지 감량화를 도모하고 있다. 슬러지의 감량화 및 바이오가스 발생량의 증대를 위해 혐기성 소화 전에 슬러지를 전처리시키는 다양한 기술 개발이 이루어지고 있다. 혐기성 소화 공정은 가수분해, 산 생선, 초산생성 및 메탄생성 단계로 구분될 수 있으며, 이 중 가수분해 단계는 율속단계로서 전체 혐기성 소화공정의 효율 및 속도를 조정하기 때문에 가수분해 단계가 쉽게 이루어지기 위해 가용화라는 슬러지의 전처리를 수행하는 것이다. 전처리 공정의 방법으로는 열적처리, 화학적 산화, 기계적 처리, 생물학적 처리 등이 있다. 이 중 생물학적 처리 공정은 고온 호기성 박테리아를 배양시킨 후 소화조에 주입하여 슬러지의 혐기성 소화효율을 향상시키는 방법과 소량의 산소를 주입하지만 일정한 혐기 조건과 낮은 환원 조건을 유지하면서 미생물의 성장과 효소 합성 및 활성을 유발시켜 슬러지의 가용화 및 소화효율을 향상시키는 방법이 있다. 이에 본 연구에서는 공기의 주입을 통한 생물학적 전처리 방법이 슬러지 내에 존재하는 유기물뿐만 아니라 질소와 실록산 등의 거동에 미치는 영향을 분석하여 공기 주입을 통한 생물학적 전처리 방법이 혐기성 소화효율 향상과 반류수질, 바이오가스 정제시설 중 실록산 제거시설 등에 미치는 오염부하의 저감 가능성을 평가하고자 하였다. 실험결과, ORP는 공기 주입기간이 길어질수록 약간씩 증가하였으나 -247 ~ -268 mV의 환원조건을 나타내었으며, DO는 0.00 ~ 0.22 mg/L로 나타났다. 따라서 슬러지 전처리를 위해 공기를 주입하여도 소화조 내의 혐기성 조건에 미치는 영향은 미미할 것으로 판단된다. SCODcr의 경우에는 공기를 주입에 따라 SCODcr의 농도가 증가하여 공기주입에 의한 가용화 효과가 있는 것으로 나타났다. 총 질소와 암모니아성 질소의 경우 공기주입기간이 길어질수록 농도가 감소하는 경향을 나타내었다. 이는 DO 농도가 1 mg/L 이하의 조건을 유지하고 있어 공기주입에 의한 동시 질산화 및 탈질 현상이 발생한 것으로 판단된다. 따라서 공기주입에 의한 전처리 방법이 슬러지 내 질소의 부하를 감소시켜 암모니아성 질소로 인한 혐기성 소화의 저해 가능성과 혐기성 소화 후 반류수 및 방류수에 영향을 미치는 질소 부하를 저감시킬 수 있을 것으로 판단된다. 실록산의 경우 공기주입 기간 증가에 따라 공기를 주입하지 않은 슬러지 내의 실록산 농도가 6.06 mg/kg에서 공기주입 4일째에는 3.43 mg/kg으로 감소하여, 공기주입 전처리 방법을 통해 바이오가스 정제 시설 중 실록산 처리 공정에 미치는 실록산 부하를 저감시킬 수 있을 것으로 사료된다.
The objective of this research was to suggest the estimation method of air injection quantity for pre-stabilization of landfilled wastes in a sustainable landfill. A study on the determination of oxygen demand quantity of landfilled wastes, therefore, was conducted in two different experiments. Firstly, a batch test was performed in order to measure the oxygen quantity required to oxidize easily degradable organic matter under aerobic conditions. Secondly, a lysimeter experiment was carried out to assess the air injection period according to moisture content (20%, 30%, 40%, 50%) and to validate the oxygen demand quantity obtained by the batch test. This study assumed that landfilled wastes contain two different organic matters and two matters are sequentially utilized by microorganism. The first one provides the faster oxygen uptake rate that called the “easily degradable organics”. During the second phase of the aerobic decomposition, the other one provides the slower oxygen uptake rate that called the “moderately degradable organics”. Also, in this study, a modified logistic equation divided two terms (fractions of easily degradable organic and moderately degradable organic) was suggested to determine the oxygen demand quantity for easily degradable organic of landfilled solid waste. As a result, the oxygen demand quantity obtained by the batch test led to similar results compared with that of lysimeter experiment. Therefore, it showed that the modified logistic equation and batch test were appropriate for determination of oxygen demand quantity for decomposition of easily degradable organic matter. Also, air injection period for decomposition of easily degradable organic decreased with the increase of moisture content.