        2.
        2017.04 구독 인증기관 무료, 개인회원 유료
        Recently, for efficiency increase of the wind turbine tower, turbine has been enlarged and installation location has been transferring to offshore. The importance of the support structure is emphasized when a wind turbine tower is installed on offshore. The support structure is influenced not only by the system operating loads but also by various marine condition loads. Accurate and safe design is essential because the connection between the support structure and the wind tower can be relatively fragile. In particular, the type of foundation pile and sleeve grout connection were adapted from DNV, API, and ISO that are typically used for wind towers, and they have been continuously studied by many researchers. However, the experimental results by researchers are different from the design equations, and it needs to modify the formula according to connection properties and material. Therefore, this study investigates the design equation presented in existing design criteria and the results of research conducted by existing researchers, and analyzes ultimate strength and failure modes.
        3,000원
        3.
        2015.04 구독 인증기관 무료, 개인회원 유료
        Generally, the Load of upper structures is transferred to concrete foundations through columns supporting them. So, the anchor connection system is usually adopted in order to connect the columns and the concrete foundations. To apply this system, the column-foundation connections need to be designed with enough stiffness. This study was experimentally conducted to effectively improve the structural detail of circular CFT column-foundation connections, to which axial and lateral load simultaneously apply. For this study, the test specimen with a general anchor and an anchor frame, and the specimens with the high-tension bolt and inner reinforcement were fabricated. In addition, double base plates were adopted to have the enough stiffness of connections. The behavioral characteristics and the failure mode were investigated and compared, and the improvement of structural detail of circular CFT column-foundation connections was suggested.
        3,000원
        4.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, circular sectional concrete-filled tube(CFT) column-to-foundation connections were numerically investigated in order to improve their structural details. A inner reinforced specimen with high-tension bolts and inner deformed bars was adopted from a previous experimental study to make the numerical model. The validity of the numerical method was verified through comparing the experimental results with the analysis’s ones. In order to optimize design variables about the inner reinforced model, a number of numerical analyses were conducted for various variables. Finally, this study suggested the optimum variables about the reinforced circular sectional CFT column-to-foundation connections.
        4,000원
        5.
        2016.04 서비스 종료(열람 제한)
        In This Study, it was intended to performance of the joint grout for offshore wind power substructure. The flow, setting time, compressive strength, flexural strength, tensile strength of basic property and resistance to rapid freezing and thawing, ability to resist chloride ion penetration were carried out as the performance test. Also, on the grout by adding fiber checked flexural toughness, cracking tendency test.
        6.
        2014.10 서비스 종료(열람 제한)
        Recently, new cities of Korean coastal area, connective land·bridge and marine structure are increased. However, actually the evaluation method of pile head strengthening performance is not clearly defined, and, in spite of many technology proposed, its qualitative evaluation is not made. Therefore, the fact is that the prefabricated pile head strengthening stability is not verified. Therefore, it’s necessary to evaluate various technologies strategically and verify safety of precast file’s cap.
        7.
        2014.02 서비스 종료(열람 제한)
        본 연구에서는 기존의 원형단면 CFT 기둥-기초부 연결부의 문제점을 분석하고 이를 개선하기 위한 구조상세를 제안하였다. 앵커를 이용한 구조물의 연결은 원형단면을 가진 CFT 기둥의 경우 하부에 베이스플레이트를 설치하게 된다. 기초부 설계시 앵커의 연결성능을 향상시키기 위하여 앵커프레임을 설치하게 되는데 이는 설계시 구조물의 구조상세가 복잡해지게 되며 시공 규모 또한 증가하게 된다. 또한 상부의 하중이 커짐에 따라 연결부의 앵커배치가 2열,3열로 증가하여 기초부와 콘크리트의 연결상세가 복잡해지고 경제적인 설계의 어려움이 있다. 이러한 기초부의 과도한 설계를 개선하기 위하여 새로운 구조상세에 대한 연구가 필요하다. 앵커연결을 지지하는 앵커프레임에 대한 구조상세를 개선하기 위하여 기존에 사용된 앵커대신 고장력 볼트를 사용하여 연결성능을 향상시켰으며 앵커프레임의 생략을 유도한 구조상세를 제안하였다. 이러한 연결상세의 합리적인 검토를 위하여 기존의 설계법과 고장력 볼트를 이용한 시험체를 각각 제작하였고 실험을 통하여 거동특성을 분석하였다. 고장력 볼트의 적용성을 확인하여 CFT 기둥-기초부의 연결성능을 향상시키기 위한 다양한 구조상세를 제안하였다. 고장력 볼트의 전단연결재 설치, 내부보강형식에 따른 구조상세 등 총 4가지의 설계변수를 기준으로 하여 시험체를 제작하였으며 탄성영역에서의 변형률 분포특성과 하중-변위관계를 통한 이력거동특성에 대한 검토를 수행하였다. 또한, 실험결과의 분석을 통하여 기둥부와 연결부의 강도평가를 실시하여 연결구조에 대한 개선된 구조상세를 제안하였다. 개선된 구조상세를 기준으로 유한요소해석을 실시하고, 이에 대한 타당성 검증 및 설계변수를 설정하여 이론에 의한 강도평가를 실시하고 개선된 구조상세에 대한 영향을 검토하였다.
        8.
        2008.01 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 강관 말뚝 두부보강 방법으로 사용되고 있는 용접방법과 훅형방법의 성능평가를 위한 실험적 연구를 수행하였다. 실험은 강관 말뚝 두부 연결부에 작용하는 대표적 하중인 압축과 수평하중에 대한 정적 재하실험과 인장실험으로 구분하여 수행하였다. 압축하중은 강관말뚝이 부담하는 주된 하중이며, 수평력은 지진하중을 고려하여 설계할 때 필수적으로 검토하여야 한다. 또한, 강관 파일 두부연결부의 인장내력은 안전성 검토에 있어서 중요한 요인으로 고려되고 있다.강관 말뚝 두부보강 성능평가 실험에서 고려된 실험변수는 Table 1과 같이 두부보강방법인 훅형과 용접형을 고려하였다. Table 1에 실험체 일람을 나타내었다.