검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 15

        1.
        2024.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to experimentally analyze the seismic performance of beam-column specimens with vertical irregular, which were reinforced with RHS (Replaceable steel haunch system). a steel haunch system. To evaluate the seismic performance of the RHS, three specimens were manufactured and subjected to cycle loading tests. Retrofitted specimens have different beam-upper column stiffness ratio as a variable. The stiffness ratio of beam-upper column were considered to be 1.2 and 0.84. As a result of the test, the specimen reinforced with RHS showed improved maximum load and effective stiffness, and energy dissipation capacity compared to the non-retrofitted specimen with same beam-upper column stiffness ratio. The specimen with 0.84 beam-upper column stiffness ratio showed improved performance than the specimen with 12.
        4,000원
        2.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, the occurrence frequency of earthquake has increased in Korea, and the interests for seismic reinforcement of existing school buildings have been raised. To this end, the seismic performance evaluations for school buildings that did not accomplish the seismic design are required. In particular, this study checks the eigenvalue analysis, pushover curves, maximum base shears, performance points and story drift ratios, and then analyzes the seismic performance characteristics according to bracing configuration of steel frame system reinforcement. Also, this study presents the practical field application methods through the comparison of analysis results for the seismic performance characteristics.
        4,200원
        4.
        2019.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        기존 내진보강시스템의 문제점을 개선하기 위한 듀얼프레임형 내진보강시스템은 기존구조체, 외부보강체, 댐퍼로 구성된다. 듀얼시스템은 지진발생시 주기차이로 인하여 기존구조체와 외부보강체 사이에서 상대변형이 발생되고 이를 댐퍼가 대응하여 안정적으로 지진에너지를 흡수하여 내진성능을 확보한다. 본 논문에서는 듀얼시스템의 구조성능을 분석하기 위하여 정적반복가력실험을 수행한다. 실험결과, 듀얼시스템 실험체는 비보강 실험체와 유사한 손상상태를 나타내었다. 이와 같이 나타난 이유는 정적실험 시 기존구조체를 강제 이력 시켰기 때문이다. 하지만 하중-변형관계곡선에서 핀칭현상이 완화되는 것으로 나타났고, 안정적인 이력거동을 통하여 비보강 실험체에 비해 5.3배 더 많은 에너지를 흡수하였다. 또한 동일한 층간변형각 및 누적 변형에 대해서도 더 많은 에너지를 흡수할 수 있음에 따라 듀얼시스템을 적용할 경우 내진성능을 향상시킬 것으로 판단된다. 또한 듀얼시스템을 실무에 적용하기 위해서는 설계프로세스 등에 대한 연구가 필요하며, 본 논문을 추후 연구의 기초자료로 제시하고자 한다.
        4,000원
        5.
        2019.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 국내의 지진발생 빈도가 증가함에 따라, 지진피해 저감 시스템 중 가장 효율이 높은 제진방식의 문제점을 해결하며 댐퍼의 복원성과 에너지 소산 능력을 증가시켜 잔류변형 감소와 사용성 증대 효과를 발생시키는 새로운 제진설계 방식이 필요하다. 본 연구에서는 학교 등 기존에 시공된 비내진상세 철근콘크리트 구조물의 지진에 의한 뒤틀림 방지, 횡방향 변위제어 및 진동저감을 위하여 구조물의 양 옆에 원형강봉댐퍼를 설치하는 시스템을 제안하고, 2층 철근콘크리트골조 실험체를 반복횡 하중 가력 하여 내진성능을 평가하였다. 무보강 및 보강 실험체들의 실험결과를 비교한 결과 외부보강용 원형강봉댐퍼 시스템이 2층 철근콘크리트 골조의 강성과 에너지소산면적을 증가시켜 내진성능을 증가시킴을 확인하였다. 또한 원형강봉댐퍼가 지진 에너지를 소산하여 지진력을 흡수함을 확인하였다.
        4,000원
        6.
        2019.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        2016 Gyeongju and 2017 Pohang earthquakes led Koreans to acknowledge that the Korean peninsula is not an earthquake-free zone anymore. Among various buildings crucial to after-shock recovery, general hospital buildings, especially existing old ones, are very significant so seismic retrofitting of those must be an important issue. Self-centering energy dissipative(SCED) brace is one of retrofitting methods, which consists of tendon with restoring force and friction device capable of dissipating seismic energy. The strength of the SCED brace is that the tendon forces a structure to go back to the original position, which means residual drift can be negligible. The residual drift is a very important parameter to determine usableness of general hospitals after shock. To the contrary, buckling-restrained braces(BRB) are also a very effective way to retrofit because they can resist both compressive and tensile, but residual drift may exist when the steel core yields. On this background, the seismic retrofitting effect of general hospitals reinforced with SCED braces was investigated and compared to that of the BRD in this study. As a result, although the floor acceleration cannot be reduced, the story drift and residual drift, and the shear demand of walls significantly decreased. Consequently, seismic retrofitting by SCED braces are very effective for domestic low-rise general hospitals.
        4,000원
        7.
        2018.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Existing reinforced concrete building structures have seismic vulnerabilities due to their seismically-deficient details resulting in non-ductile behavior. The seismic vulnerabilities can be mitigated by retrofitting the buildings using a fiber-reinforced polymer column jacketing system, which can provide additional confining pressures to existing columns to improve their lateral resisting capacities. This study presents dynamic responses of a full-scale non-ductile reinforced concrete frame retrofitted using a fiber-reinforced polymer column jacketing system. A series of forced-vibration testing was performed to measure the dynamic responses (e.g. natural frequencies, story drifts and column/beam rotations). Additionally, the dynamic responses of the retrofitted frame were compared to those of the non-retrofitted frame to investigate effectiveness of the retrofit system. The experimental results demonstrate that the retrofit system installed on the first story columns contributed to reducing story drifts and column rotations. Additionally, the retrofit scheme helped mitigate damage concentration on the first story columns as compared to the non-retrofitted frame.
        4,000원
        8.
        2012.03 구독 인증기관 무료, 개인회원 유료
        The interest for the stability of the structures against earthquake, which is increasing recently, is rapidly increasing. But, currently, school buildings among the reinforced concrete(RC) structures in Korea are not designed with seismic design or there are many cases of being designed with the old seismic design code, so it is estimated to have not only lives but also a great deal of economic damage are likely to occur when an earthquake occurs. In this study, proposed horizontal friction system(HFS) with rotary friction damper installed as a method to reinforce strength and hardness and to increase ductility for the low story structure of 5 stories or lower such as school buildings. For the seismic retrofitting design with horizontal friction system in which rotary friction damper is installed, Peak displacement response ratio according to elastic and inelastic behavior and ductility demand is calculated to decide elastic stiffness and strength of the HFS, design model and procedure to decide the capacity of HFS thereof is decided, and the feasibility and performance are reviewed through pushover analysis.
        4,000원
        9.
        2009.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 전력, 통신 등 다양한 주요 기간설비의 운영에 필수적인 전기판넬의 내진성능개선을 위하여 내진보강시스템을 개발하고, 이 시스템의 내진성능평가를 위하여 진동대시험을 수행하였다. 본 연구에서 개발된 전기판넬 내진보강시스템은 이중바닥시스템(Access floor) 상에 설치된 전기판넬을 대상으로 운전하에서 무정전, 무이설 방식으로 내진보강이 가능하다는 장점을 지니고 있다. 진동대시험을 통해 전기판넬 내진보강시스템의 성능평가를 위하여 지진하중으로서 건물 내 여러 층에 설치되는 전기판넬의 특성을 고려하여 포괄응답스펙트럼을 입력하였다. 진동대시험은 널리 상용화되어 있는 스틸과 우드판넬 등 두 형식의 이중바닥시스템과 일반 전기판넬을 대표할 수 있는 동특성이 다른 두 종류의 전기판넬을 고려하여 총 4회 수행하였다. 진동대시험결과, 내진보강시스템은 진동대시험 중 및 후에도 전도 등으로 인한 전기판넬의 파손을 방지하는 등 전기판넬의 내진안전성을 확보하여 주는 것으로 나타났다. 따라서, 이중바닥시스템 상에 설치된 전기판넬에 개발된 내진보강시스템을 적용하는 경우, 지진으로 인한 전기판넬의 파손을 효과적으로 방지하여, 국내 주요 기간설비의 안정적 운영에 크게 기여할 수 있을 것으로 판단된다.
        4,000원
        10.
        2007.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 교량의 내진보강을 위하여 기존 교량에 지진격리장치를 추가하는 접근법을 제안하였다. 기존 받침을 지진 격리받침으로 완전히 대체하는 접근법도 이미 제안되어 있지만 본 연구에서는 경제성과 안전성을 고려하여 기존 받침을 제거하지 않고 활용하도록 하였다. 이는 지진격리받침이 상부 수직하중을 분담하지 않고, 수평방향의 지진운동에 대한 주기 이동과 감쇠 역할만 한다. 이 접근법의 실험적 검증을 위해 실제 교량을 대상으로 납-적층고무받침(LRB)을 설계하고 실물크기로 기존 받침과 LRB를 제작하였다. 이 지진격리시스템의 가상 지진입력에 대한 응답은 유사동적실험으로 구하였다. 아울러 범용해석프로그램을 통한 지진응답해석과 비교하여 실험결과의 신뢰성을 확인하였다. 실험결과 제안된 지진격리시스템은 지진시 안정적인 거동을 보였다.
        4,000원
        11.
        2019.10 서비스 종료(열람 제한)
        본 연구에서는 비내진상세를 가지는 중⦁저층 R/C 건물의 1층 골조를 제작하여 무보강 실험체에 대한 구조실험을 실시하였다. 실험결과 실험체는 부재각 1.33%에서 전단파괴를 나타내어, 비내진상세를 가지는 R/C 건물의 내진성능에 관한 중요한 자료를 획득하였다. 본 연구에서는 간주형 좌굴방지 강재 슬릿댐퍼 시스템을 개발하였으며 내진보강효과를 검증하기 위하여 구조실험에 선행하여 상기 국내 비내진상세 RC 골조 실험결과를 기반으로 비선형해석을 실시하였다.
        12.
        2018.09 KCI 등재 서비스 종료(열람 제한)
        본 연구에서 제안하는 내진보강기법은 듀얼시스템으로 비내진상세로 설계된 저층구조물을 대상으로 적용하기 위한 기법이다. 듀얼시스템은 기존의 구조체, 외부보강체, 강재이력댐퍼로 구성되고 구조체와 외부보강체 사이에 강재이력댐퍼를 설치한다. 구조체와 외부보 강체는 강성과 적재하중에 의해 서로 다른 주기에 의해 상대변위가 발생되고 강재이력댐퍼를 통해 지진에너지를 흡수한다. 본 연구에서 제안 된 듀얼시스템의 내진성능을 검증하기 위해 동적실험을 수행한다. 동적 실험결과, 듀얼시스템 보강 시 에너지가 1.84배 더 많이 입력됨에도 불구하고 56%의 변형 저감과, 93%의 손상 저감이 됨에 따라 듀얼시스템 적용 시 내진성능을 향상시킬 것으로 판단된다. 그리고 연구결과는 듀얼시스템의 설계범위를 설정하기 위한 추후 연구의 기초자료로 제시하고자 한다.
        14.
        2013.04 서비스 종료(열람 제한)
        The double frame system is composed of existing structure, external retrofit frame and hysteretic steel dampers installed between former two components. The DFS retrofit system dissipates the energy by plastic deformation of steel damper caused by relative displacement due to the differences in stiffness, weight, and eigenperiod of each components. The dynamic test with shaking table was performed to verify the seismic performance of the proposed DFS system
        15.
        2011.02 서비스 종료(열람 제한)
        2008년 중국의 쓰촨성 지진시 기존 학교 건축물의 피해가 매우 심각하였으며, 학교 건축물은 청소년의 인명보호, 재난시 대피장소로의 이용 등을 위하여 내진성능의 확보가 매우 중요하다. 국내 학교 건축물의 경우, 주로 2000년 이전에 설계된 저층 철근콘크리트(이하 RC) 구조로 내진성능이 부족하며 골조내 조적 허리벽이 기둥의 수평변위를 구속하여 단주화로 인해 전단파괴 될 가능성이 높다. 이에 대한 내진보강으로 선행 연구에서 강재이력댐퍼를 골조 내에 설치하여 기둥을 전단보강하고 이력댐퍼에 의해 에너지를 흡수하는 장치인 강재댐퍼시스템을 제안한 바 있으며, 실험적 연구를 통하여 그 성능을 확인하였다. 반면 이를 뒷받침할 수 있는 해석적 연구는 부족한 실정으로, 본 연구에서는 선행 연구에서 제안된 강재댐퍼시스템의 비선형 해석모델을 제시하고, 이에 대한 비선형 정적해석결과를 실험결과와 비교하여 해석모델의 타당성을 검증하였다. 강재댐퍼시스템의 부재 모델링 요소는 비선형 거동을 나타내는 스프링을 가지는 선형요소를 사용하였으며, 모델링 방법은 (1)강재댐퍼시스템의 모든 부재를 각각의 선형요소로 모델링한 전체모델과 (2)모델링의 간략화를 위하여 강재댐퍼시스템의 슬릿형 강재이력댐퍼(이하 슬릿댐퍼)와 하부 지지기둥을 각각 하나의 선형요소로 모델링한 간략모델의 2가지로 하였다. 또한 슬릿댐퍼의 비선형 이력모델을 Bi-Linear, Tri-Linear, Ramberg-Osgood 형의 3가지를 사용하여 총 6개의 해석변수를 사용하여 비선형 정적해석을 수행하였다. 전체모델과 간략모델을 이용하여 해석을 수행한 결과, 내력 및 이력거동 등 강재댐퍼시스템의 성능은 거의 일치하는 경향을 나타내었다. 또한 슬릿댐퍼의 비선형 이력 모델을 변수로 해석한 결과, Bi-Linear, Tri-Linear형의 이력모델의 경우 항복하중 및 최대내력이 저평가 되었으며, 반복하중 작용시 내력이 증가하는 것을 반영할 수 있는 Ramberg-Osgood형의 비선형 이력모델을 적용한 경우 실험결과와 가장 일치하는 경향을 나타내었다.