The effect of permanganate oxidation was investigated as water treatment strategy with a focus on comparing the reaction characteristics of NaOCl and sodium permanganate (NaMnO4) in algae (Monoraphidium sp., Micractinium inermum, Microcystis aeruginosa)-contained water. Flow cytometry explained that chlorine exposure easily damaged algae cells. Damaged algae cells release intracellular organic matter, which increases the concentration of organic matter in the water, which is higher than by NaMnO4. The oxidation reaction resulted in the release of toxin (microcystin-LR, MC-LR) in water, and the reaction of algal organic matter with NaOCl resulted in trihalomethanes (THMs) concentration increase. The oxidation results by NaMnO4 significantly improved the concentration reduction of THMs and MC-LR. Therefore, this study suggests that NaMnO4 is effective as a pre-oxidant for reducing algae damage and byproducts in water treatment process.
The Ministry of the Interior and Safety in Korea developed seismic fragility function for various building types in 2009. Damage states for most building types were determined by structural analyses of sample models and foreign references because actual cases damaged by earthquakes rarely exist in Korea. Low-rise, piloti-type buildings showed severe damage by brittle failure in columns due to insufficient stirrup details in the 2017 Pohang earthquake. Therefore, it is necessary to improve damage state criteria for piloti-type buildings by consulting actual outcomes from the earthquake. An analytical approach was conducted by developing analysis models of sample buildings reflecting insufficient stirrup details of columns to accomplish the purpose. The result showed that current spectral displacements of damage states for piloti-type buildings might be too large to estimate actual fragility. When the brittle behavior observed in the earthquake is reflected in the analysis model, one-fourth through one-sixth of current spectral displacements of damage states may be appropriate for existing low-rise, piloti-type buildings.
본 연구에서는 일반 폴리시와 젤 폴리시의 안전성 인식 및 손톱 손상도에 대해 알아보고자 하였다. 연구방법은 본 연구에 참여를 동의한 20~50대 여성을 대상으로 사전 설문조사와 실험 연구를 진행하였다. 그 결과, 일반 폴리시와 젤 폴리시의 효과성 인식, 안전성 인식, 손톱 손상도 인식 차이에서 모두 젤 폴리시가 높게 나타났다. 실험 전·후 손톱의 수분, 유분, 경피수분손실량(TEWL)은 실험 전보다 모두 감소 하였으며, 일반 폴리시에 비해 젤 폴리시의 감소 폭이 높게 나타남을 확인하였다. 또한 손톱의 SEM 표면 관찰에서도 젤 폴리시의 손톱 표면 손상도가 매우 크게 나타남을 확인하였다. 이상과 같이 본 연구를 통해 일반 폴리시보다 젤 폴리시가 손톱의 손상도에 많은 영향을 미치는 것을 확인하였다. 따라서 소비자들의 건강하고 아름다운 손톱관리 및 유지를 위한 기초 자료로 도움이 될 수 있기를 기대한다.
본 연구에서는 천연헤나 처리 후 펌(permanent wave)을 시술하여 모발의 손상도 및 형태학적 변화에 미치는 영향을 알아보기 위해 실험을 진행하였다. 실험 방법은 아미노산분석, 주사현미경측정에 의한 모발의 두께와 표면관찰, 모발의 컬 형성력과 지속력, 메틸렌블루 염색법, 인장강도와 신장률을 측정하 였으며, 그 결과는 다음과 같다. 아미노산 총량은 천연헤나 처리횟수가 증가할수록 증가하였으며, 모발 보호 효과가 있을 것으로 보인다. 컬 형성력은 대조군에 비해 천연헤나 처리 횟수가 증가할수록 컬은 탄력이 있었다. 지속력은 대조군과 실험군 모두 샴푸 횟수가 많을수록 Ⓒ와 Ⓒ’ 길이의 늘어짐이 증가하여 지속력이 감소하였으며, 주사전자현미경에 의한 모발의 두께는 대조군(Control)에 비해 실험군 모두 천연헤나처리 후 모발의 두께가 굵어졌다. 표면의 형태적 관찰에서는 실험군 모두 모발의 표면이 대체적으로 깨끗하고 큐티클 층이 잘 정돈되어 있음을 확인하였다. 또한 메틸렌블루염색법에서는 천연헤나처리 횟수가 증가 할수록 흡광도 값은 증가하였다. 인장강도는 대조군에 비해 실험군 모두 인장강도가 감소하였으며, 신장률은 천연 헤나 처리횟수가 증가할수록 실험군의 신장률이 증가하였다. 이상의 결과를 종합하면 천연헤나 처리횟수가 증가할수록 모발의 두께가 굵어졌고, 모발의 컬 형성력과 지속력이 높아졌으며, 모발에 탄력성과 유연성을 부여함으로서 모발 손상을 완화 시킬 수 있음을 알 수 있었다. 따라서 본 연구의 천연헤나 시술법 은 염색과 펌의 잦은 화학시술로 인한 고객의 손상된 모발을 관리하고, 미용산업 현장에 올바른 시술방법 제안으로 두피와 모발손상을 줄이는데 기초자료로 도움이 될 수 있을 것이다.
Stone pagoda structures have continued to be aged due to the combination of various damage factors. However, some studies on nonstructural damage have been carried out, but assessment studies on structural damage have not been done in various ways. Therefore, in this study, structural and nonstructural influencing factors according to the damage types are classified and the damage assessment according to the structural influencing factors affecting the behavior of the stone pagoda structure is performed. In addition, the damage rating classification criteria for each type of structural damages or damage locations are presented, and the damage index is calculated by providing the criteria for the classification of damage according to the degree of damage to which the damage is caused. Therefore, this study can evaluate quantitatively the damage status of stone pagoda structures.
The purpose of this research is to provide accurate information of household washers and detergents for consumers, so that help the producers who make washing machine and detergent to get basic material and also help consumers to choose washing machine. Experiment was proceed with two type of washers to compare energy consumption, washing performance, rinsing effectiveness further, damage caused by entanglement of laundry and fabric was assessed. Detergent P and T were used to compare the performance related to differences of ingredients of detergent. Soiled fabrics of EMPA 108 set were used to evaluate performance of washing by different types of contamination. A summary of experimental results are : First, for the consumption of water, drum-type washer consumed 53% less than pulsator-type washer. On the other hand, the washing time was almost similar for both these machines, but pulsator-type washer showed shorter progress, implying that power saving was more efficient in this case. Second, the drum-type washer showed better performance for contamination with all types of detergent, but the pulsator-type washer showed better rinsing performance. Third, the drum-type washer performed less data of tangle level and fabric damage. Fourth, detergent "P" exhibited better washing performance than did detergent "T", regardless of the type of soil. And with no limit of detergent variety, water-soluble protein soil showed high removal rate, liposoluble soil especially pigment was hardly removed.
In the Korean Building Code (KBC), the Design Eccentricity involves the torsional amplification factor (TAF), and the inherent and accidental eccentricities. When a structure of less than 6-stories and assigned to seismic design category C or D is designed using equivalent static analysis method, both KBC-2006 and KBC-2009 use the TAF but apply different calculation methods for the of design eccentricity. The design eccentricity in KBC-2006 is calculated by multiplying the sum of inherent eccentricity and accidental eccentricity at each level by a TAF but that in KBC-2009 is calculated by multiplying only the accidental eccentricity by a TAF. In this paper, the damage indices of a building with planar structural irregularity designed by different design eccentricities are compared and the relationship between the earthquake damage and design eccentricity of the building is evaluated. On the basis of this study, the increment of design eccentricity results in the decrement of final eccentricity and global damage index of structure. It is observed that design eccentricity in KBC-2006 reduces the vulnerability of torsional irregular building compared to design eccentricity in KBC-2009.
비정형 평면을 가진 건물의 추가적인 손상의 원인이 되는 비틀림과 비정형성의 척도인 편심과의 관계에 대한 많은 연구들이 진행되어 왔으나 손상도와 편심의 직접적인 관계에 대한 연구는 수행된 적이 거의 없다. 본 연구에서는 비정형 평면을 가진 건물의 복잡한 지진 응답에 적용할 수 있는 3차원 손상도 계수를 이용하여 건물의 손상도와 편심에 대한 정량적인 관계를 분석하였다. 이를 통해 건물의 편심이 커지면 최대변위는 줄어들지만 비틀림 거동이 증가하여, 손상의 집중으로 인해 전반적인 손상도 계수가 증가함이 관찰되었다. 또한, 2차원 주기가 비슷한 경우에는, 건물의 길이가 최대변위와 최대 비틀림에 미치는 영향이 작으며 이로 인해 전체 손상도 계수에도 그 영향이 미미한 것으로 관찰되었다. 해석 결과를 바탕으로 중약진 지역에서 편심의 크기가 10%, 20%, 30%인 단층 건물은 편심이 없는 건물에 비해서 각각 평균 3~5%, 13~18%, 33~47% 정도의 손상도 증가가 있을 것으로 분석하였다. 이와 같은 편심-손상도 관계는비정형 평면을 가진 건물의 내진 설계에 있어서 기본 구조 계획 수립과 내진 성능 평가에 유용한 자료가 될 것으로 생각된다.
지진피해를 입은 건물의 주된 관심사는 건물에 남아 있는 내진성능 및 여진에 대한 안전성을 판단하는데 있다. 따라서 지진피해를 입은 지역 사회의 조속한 복귀를 위해서는 건물의 잔존내진성능 평가방법을 확립해 두는 것이 필수적이다. 본 연구에서는 무보강 조적채움벽체를 갖는 RC 건물의 잔존내진성능 평가방법 개발을 주목적으로, 전형적인 학교건물을 대상으로 축력레벨을 변수로 한 실스케일, 단층 1스팬 실험체를 제작하여 정적 반복가력실험을 실시하였다. 실험 중 잔존내진성능을 판정하는데 유용한 정보 중 하나인 잔류균열폭을 상세히 측정하였다. 본 논문에서는 잔류균열폭과 잔존내진성능과의 관계에 대해서 실험적, 해석적으로 검토하고 잔존내 진성능 평가를 위한 각 손상도 레벨에 대응하는 내진성능 저감계수를 제안한다.
본 논문에서는 다자유도계 구조물의 진동대 실험결과 분석에서 효율적인 지진손상도 평가 및 소성모형 추정을 목적으로, 계측결과를 각 부재별 소성이력으로 환산하고 이 소성이력에 대해 비선형 계수 추정법을 적용하는 다단계 방안을 연구하였다. 이때, 추정된 부재별 소성이력은 부재별 지진 손상도를 평가하는 지표로 활용될 수 있으며, 추정된 비선형 모형 계수를 이용하여 구축된 비선형 다자유도계 구조는 다양한 구조재해석의 모형으로 활용될 수 있다. 제시된 방법의 검증을 위해, 해석적 방법과 실험적 방법의 예제해석이 수행되었다. 예제해석 결과는 해석적 방법과 실험적 방법 모두에서 본 논문의 방법이 매우 효과적임을 보여 주고 있다.
본 연구에서는 기설구조물에 대한 손상도 추정기법과 내진능력평가 방법에 대하여 연구하였다. 구조물의 손상도를 추정하는 방법으로는 소수의 계측 데이터를 이용한 모드섭동법(inverse modal perturbation)을 이용하였다. 구조물의 손상은 강성행렬의 감소로 표현하여, 각 요소행렬에 대한 손상을 손상지수를 사용하여 나타내었다. 구조적 손상과 이에 기인한 고유진동 특성의 변화량과의 관계를 섭동방정식으로부터 구한 후, 이로부터 손상지수와 고유진동 특성의 변화량과의 관계를 유동하였다. 따라서 손상 전과 후에서 구조물의 고유진동수와 모드형상을 측정하여 섭동식의 해를 구함으로써 구조물의 강성행렬의 감소로 나타나는 구조물의 손상도를 추정하게 된다. 손상도 추정에 의해 평가된 강성의 변화량에 기인한 손상 후의 기설구조물의 지진응답, 내진능력과 지진손상도의 평가를 손상전과 비교하였다. 내진능력은 구조부재에서 회전연성도 능력의 경험식을 이용하여 평가하였고, 지진손상도의 평가는 가장 많이 사용되는 방법인 Park & Ang 방법을 사용하였다. 예제해석은 다른 지진하중을 받는 2층과 8층의 예제구조물에 대해서 수행하였다.
대부분의 손상도 추정법들을 부재의 손상을 해당부재의 평균적인 강성감소로 표현하였다. 본 연구에서는 보다 실제적인 손상도를 추정하기 위하여, 접합부의 손상을 도입하였다. 접합부의 모형화를 위하여 보의 양단에 회전스프링을 추가하였으며, 접합부 손상을 접합부 강성의 감소로 정의하였다. 접합부의 손상도를 계측된 모드벡터를 바탕으로하여, 신경망기법을 추정하였다. 효율적인 훈련패턴을 만들기 위하여 Latin Hypercube Sampling 기법을 도입하였으며, 국부영역에서의 손상도추정을 위하여 부구조법을 도입하였다. 제안된 기법의 효율성을 검증하기 위하여 10층 프레임구조물에 대한 수치해석결과를 이용하였다. 예제해석을 통하여 추정결과가 상당히 정확함을 확인하여, 실제 적용 가능한 방법임을 알수 있었다.
본 논문에서는 동특성추정법 (system identification) 을 이용한 교량구조의 손상정도를 평가하는 방법이 제
시되었다. 손상된 구조물의 비선형 동적거동은 휩모우멘트와 곡률반경의 시간이력 관계로써 표시하였으며,
구조물의 성질을 나타내는 특성계수는 실측자료를 이용한 동특성추정법을 사용하여 추정하였다. 또한, 구조
물의 성질의 다양성과 응답의 불확실성을 고려하여 손상은 확률변수로 나타내었으며, 예제해석으로는 곡선교
의 손상도추정이 수행되었다.
교량, 발전소, 해양구조물과 같은 토목구조물은 사용기간중에 지진, 바람, 파랑하중등에 의해 구조적 손상을 받기 쉽다. 장기간에 걸쳐 구조물에 손상이 누적되면 구조물 전체의 파괴를 초래할 수도 있다. 따라서 현존하는 구조물의 안전성을 분석하기 위한 구조물의 손상도를 추정하는 방법이 필요하다. 본 논문에서는 Inverse Modal Perturbation기법을 이용하여 구조물의 손상도를 추정하는 방법에 대하여 연구하였다. Perturbation식은 구조물의 강성 및 질량행렬의 변화량과 구조물의 고유진동수와 모우드형상의 변화량의 식으로 구성된다. 또한 구조물의 손상은 강성행렬의 변화량으로 표현하였다. 본 연구에서는 구조물의 손상도추정의 효율성을 증대시키기 위하여 2차-Perturbation식을 구성하고, 이것을 반복적인 절차를 거쳐 해를 구하는 방법에 대하여 연구하였다. 제안된 방법의 효율성은 일련의 예제해석을 통하여 검증하였으며, 추정된 결과로 부터 본 방법이 구조물의 손상을 적절히 산정함을 알 수 있었다.
The purpose of this study at water quality pollutants to propose proper management method for the Osu-A unit watershed which is the influent tributary located upstream of the Sumjin -river among the 13 unit watersheds in the Sumjin-river water system. Analyzed the correlation between flow-pollution loading and the correlation between land use type, BOD and TP items, and analyzed 8-day intervals Cumulative Flow Duration Curve (CFDC) and Load Duration Curve (LDC) to evaluate water quality damage. As a result, both BOD and TP were larger than 1 and the concentration of water pollutants increased with increasing flow. BOD was positively correlated with Urban and Field, and TP was positively correlated with Field with 0.710. As a result of the LDC, BOD was analyzed that the target water quality was achieved with the excess rate of less than 50%, and TP exceeded the target water quality by 50.1%. BOD usually exceeded the standard value (exceedance probability 50%) at low flow zone and On the other hand, TP usually exceeded the standard value at high flow zone. Monthly BOD (April to June) and TP (May to August) exceeded the standard. Sewage Wastewater treatment and non-point pollution control is Osu-A unit watersheds are effective in improving BOD and TP.
In this paper, the effect of steel fiber-reinforced cement composite (SFRCC) on damage resistance of steel tube member. Test results show that the cumulative energy dissipation of SFRCC specimen was about 14% higher than that of Con specimen.