검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 20

        6.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, we evaluated the filtering effect of the fine dust mask. Our objective research has secured credibility in the private sector. The performance of domestic fine dust masks is evaluated by three dust collection efficiencies, inspiratory resistance, and leakage rate according to KF grade in the health mask standard guidelines issued by the Ministry of Food and Drug Safety. Based on this, eight types of fine dust masks were evaluated for dust collection efficiency and face intake resistance. All masks showed good performance as the collection efficiency was 90%. The higher the KF grade, the higher the collection efficiency, but the inspiratory resistance had no correlation with the grade. According to the manufacturer's operation method, masks below the standard value may be distributed. Masks that are currently on the market have shown results that can be trusted. However, we hope that the system will be improved to validate whether the masks that meet the threshold are still being distributed.
        4,000원
        7.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Membrane filtration process is an advanced water treatment technology that has excellently removes turbidity and microorganisms. However, it is known that it has problems such as low economic efficiency and the operating stability. Therefore, this study was to evaluate on the economical feasibility and operational stability comparison of membrane and sand filtration process in Im-sil drinking water treatment plant. For the economic analysis of each process, the electricity cost and chemical consumption were compared. In the case of electric power consumption, electricity cost is 68.67KRW/㎥ for sand filtration and 79.98KRW/㎥ for membrane filtration, respectively. Therefore, membrane filtration process was about 16% higher than sand filtration process of electricity cost. While, the coagulant usage in the membrane filtration process was 43% lower than the sand filtration process. Thus, comparing the operation costs of the two processes, there is no significant difference in the operating cost of the membrane filtration process and the sand filtration process as 85.94KRW/m3 and 79.71KRW/m3 respectively (the sum of electricity and chemical cost). As a result of operating the membrane filtration process for 3 years including the winter season and the high turbidity period, the filtrated water turbidity was stable to less than 0.025 NTU irrespective of changes in the turbidity of raw water. And the CIP(Clean In Place) cycle turned out to be more than 1 year. Based on the results of this study, the membrane filtration process showed high performance of water quality, and it was also determined to have the economics and operation stability.
        4,000원
        8.
        2017.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        무기실리카 입자로 구성된 고탁도 원수를 처리하는 침지식 정밀여과 운전에서 휴민산과 2가 양이온의 존재유무에 따라 시간에 따른 파울링 저항을 관찰하였다. 공기폭기로 인한 무기실리카 입자의 파울링 감소효과는 휴민산과 칼슘이 혼합 으로 존재 시 감소하였다. 파울링층의 전자현미경 관찰결과 칼슘의 존재 시 휴민산의 무기실리카 입자 표면흡착이 관찰되었 다. 이는 멤브레인 표면에 조밀한 파울링층을 형성시켜 공기폭기 효과를 감소시킨 것으로 판단된다. 용액의 조성에 따른 고탁 도 원수의 탁도 제거율에는 큰 변화가 없었으나 공기폭기량에 따라 칼슘과 무기실리카 입자의 혼합 존재 시 유기물질의 제거 율은 80% 이상으로 증가하였다. 이는 공기폭기 하에 무기실리카 입자 표면에 흡착된 일부 휴민산들이 멤브레인 표면으로부 터 함께 역수송 되어 유기물질 제거율을 증가시킨 것으로 사료된다.
        4,000원
        9.
        2012.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        스펀지 형태의 담체가 첨가된 침지형 막결합 연속회분식 생물반응기에서 담체가 제거효율과 여과성능에 미치는 영향을 조사하였다. 담체는 반응기 부피 기준으로 각각 5%, 10% 및 20% 첨가하였고, 담체를 첨가하지 않은 반응기를 대조군으로 하였다. COD, T-N 및 T-P에 대한 제거효율은 담체 첨가 유무에 관계없이 큰 차이가 없었다. 그러나 담체를 첨가한 경우, 첨가하지 않은 경우에 비해 조업시간에 따른 막간차압(TMP)은 매우 서서히 증가하였다. 이러한 결과는 폭기에 의해 상승하는 담체가 막 표면과 충돌하게 되고, 이때 막 표면에 형성된 케이크 층을 제거시키기 때문이다. 결론적으로 담체가 첨가된 막결합형 연속회분식 생물반응기는 담체가 없는 반응기에 비해 여과성능이 크게 개선되어, 폐수처리에 효과적으로 활용될 수 있을 것이다.
        4,200원
        10.
        2012.02 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to evaluate for performance of biochipfiltration phosphorus treatment process developed by ANT21 and to enhance phosphorus water quality standards to meet the optimum operation conditions of phosphorus treatment process are presented. Alum, FeCl3 as the coagulant used, each with a Jar-Test influent water quality and remaval efficiency of phosphorus treatment process when compared to water quality and removal efficiency of T-P are not a big difference, Alum in the removal efficiency and water quality was the most stable and high coagulant in the case of the removal of CODmn, SS, TN. Alum and Polymer processing efficiency when using the water quality was good and treatment water quality is CODmn 19 mg/L, SS 5 mg/L, TN 26 mg/L, T-P 0.135 mg/L less than water quality standards. If Alum is applied to the field, Alum injection amount per m3 influent unit is 24 g. During the field testing operation period, the influent has average COD mn 27 mg/L, SS 10 mg/L, T-N 22 mg/L, T-P 0.910 mg/L, and the final effluent has average CODmn 22 mg/L, SS 4 mg/L, T-N 20 mg/L, T-P 0.166 mg/L respectively. Average removal efficiency of each water quality item was CODmn 21%, SS 65%, T-N 8%, TP 82% and phosphorus treatment process is effective for the removal of SS and T-P but there is a limit to the removal of CODmn and T-N.
        4,600원
        11.
        2011.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        침지식 막결합형 연속회분식 생물반응기에서 폐수의 도입단계가 제거효율과 여과성능에 미치는 영향을 조사하였다. 호기성 단계의 초기에 공급할 경우(Mode-1)와 무산소 단계의 초기에 공급할 경우(Mode-2)에 대하여 89일 동안 동시에 운전하였다. COD 제거효율과 여과성능은 2가지 운전방식 간에 큰 차이가 없었다. 그러나 영양염류(총질소와 총인)의 제거효율에 있어서 Mode-2가 Mode-1에 비해 보다 효과적이었다. Mode-2의 경우 COD, 총질소 및 총인의 제거율은 각각 99.1, 73.3 및 77.7%이었다.
        4,000원
        12.
        2004.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 4종류의 관형 세라믹 정밀 및 한외여과막(탄소 재질)으로 제지공장의 방류수를 물로 주기적 역세척하면서 여과하였을 때, 최적 역세척 시간을 규명하였다. 각 분리막에 대상으로 물 역세척 시간의 영향을 살펴 본 결과, 분리막의 기공이 클수록 길게 역세척 하는 것이 가장 많은 총여과부피, 즉 처리수의 회수 효율이 높기 때문에 가장 효과적이라 할 수 있다. 한편, 180분 동안 여과하면서 초기투과선속에 대한 투과선속의 변화를 살펴본 결과, 정상운전시간이 길수록 막오염이 많이 진행된 상태이므로 역세척 시간을 길게 해주여야만 막오염을 억제하여 높은 투과선속을 유지할 수 있다는 것을 알 수 있었다. 또한, 막오염의 저항 변화 추이를 관찰하여 최적 물역세척 시간을 규명해 보아도, 투과선속의 변화로부터 얻은 최적 역세척 시간과 거의 동일한 결과를 얻을 수 있었다.
        4,000원
        15.
        2014.02 서비스 종료(열람 제한)
        최근 수계에 심각한 악영향을 미치는 비점오염원에 대한 정부의 관심이 대두되고 있다. 비점오염물질은 배출경로가 불명확하며, 배출량 또한 측정하기가 어려워 처리하기 또한 곤란하다. 이러한 비점오염물질 제거를 위하여 비점오염저감시설을 개발 및 설치하고 있다. 하지만 비점오염저감시설 설치 시 대상유역에 대한 연구가 미비하여 명확한 저감효율을 판단하기가 어렵다. 본 연구의 목적은 비점오염물질에 따른 저감시설의 효율을 파악함에 있다. 2년간 총 8회의 강우 모니터링을 통하여 경기도 용인시 경안천 유역에 설치 된 비점오염저감시설 중 식생형 시설인 식생여과대의 저감 효율을 ER(Efficiency Ratio) 방법을 이용하여 산정하였다. 모든 시료는 BOD, COD, TN, TP 항목에대해 수질오염공정시험법에 의거하여 분석하였다. 2012년에서의 저감효율은 각각 36%, 37%, 55%, 44%, 2013년에는 63%, 56%, 48%, 67%로 나타났다. 2년간 각 항목별 저감효율 평균값은 50%, 46%, 52% 56%로 영양염류의 제거효율이 유기물의 제거효율보다 높은 수치를 보였다. 결과적으로 경안천유역 비점오염저감시설 중 식생여과대는 영양염류의 제거에 효율적이며, 저감기능 향상을 위해 지속적인 관리와 연구가 필요하다.
        16.
        2014.02 서비스 종료(열람 제한)
        수질오염은 부유물질, 유기물질, 영양염류 등이 수계로 유입되어 물의 물리·화학적 변화를 일으키는 경우를 말한다. 배출 형태는 점오염원과 비점오염원이 있으며, 비점오염원은 점오염원에 비해 오염부하량이 상대적으로 증가하고 있어 수계에 악영향을 초래하고 있다. 이에 비점오염원의 관리가 중요해졌으며, 비점오염물질을 처리하기 위한 시설설치가 이루어지고 있다. 비점오염저감시설은 크게 자연형 시설과 장치형 시설로 구분된다. 자연형 비점오염저감시설인 식생여과대는 배출되는 오염물질을 주로 식생에 의해 처리하는 방식이다. 따라서 본 연구에서는 수질오염의 정도를 나타내는 지표인 BOD, COD, TSS 값을 산정하고, 식생여과대의 식생피도 변화에 따른 유기물질 제거효율을 분석하고자 한다. 용인시에 설치된 식생여과대에서 7년간의 모니터링을 통해 연구가 수행되었다. 탁도를 기준으로 유입·유출수의 샘플링을 했으며, 통계학적 방법으로 BOD, COD, TSS의 제거효율을 분석하였다. 식생피도는 4계급으로 분류하였고, A계급 : 0 ∼ 25 %, B계급 : 25 ∼ 50 %, C계급 : 50 ∼ 75 %, D계급 : 75 ∼ 100 % 으로 나타내었다. 유기물질과 부유물질의 제거효율은 다음과 같다. A계급에서 BOD는 24 %, COD는 5 %, TSS는 60 % 이고, B계급에서 BOD는 17 %, COD는 40 %, TSS는 77 % 이고, C계급에서 BOD는 43 %, COD는 43 %, TSS는 82 % 이고, D계급에서 BOD는 61 %, COD는 53 %, TSS는 92 % 이다. 식생피도가 증가할수록 유기물질인 BOD, COD와 부유물질인 TSS의 제거효율이 높아지는 것으로 나타난다.
        17.
        2010.04 KCI 등재 서비스 종료(열람 제한)
        The pressure drop through pulse air jet-type bag filter is one of the most important factors on the operating cost of bagfilter houses. In this study, the pilot-scale pulse air jet-type bag filter with about 6 ㎡ filtration area was designed and tested for investigating the effects of the four operating conditions on the total pressure drop, using the coke dust collected from a steel mill factory. When the face velocity is higher than 2 m/min, it is not applicable to on-spot due to the increase of power expenses resulting from a high-pressure drop, and thus, 1.5 m/min is considered to be reasonable. The regression analysis results show that the degree of effects of independent parameters is a order of face velocity > concentration > time > pressure. The results of SPSS answer tree analysis also reveal that the operation time affects the pressure drop greatly in case of 1 m/min of face velocity, while the inlet concentration affects the pressure drop in case of face velocity more than 1.5 m/min.