검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 32

        1.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The Precast concrete(PC) modular structures are a method of assembling pre-fabricated unit modules in the construction site. The essential aim of modular structures is to introduce a connection method that can ensure splicing performance and effectively resist shear strength. This study proposed PC module using a connecting plate that can replace splice sleeves and shear keys used in the conventional PC modular structures. To evaluate the splicing performance and shear capacity of the proposed method, the shear test was conducted by fabricating one monolithic reinforced concrete(RC) beam and two PC modular beams with a shear span-to-depth ratio as variables. The experimental results showed that the shear capacity of the PC modular beam was about 89% compared to that of the RC beam, and showed a failure of the RC beam according to the shear span-to-depth ratio. Therefore, it was considered that the connecting plate effectively transferred the stress between each PC module through the joint and ensure integrity. In addition, the applicability of shear strength equation of ACI 318-19 and Zsutty's equation to PC modular beams were evaluated. Results demonstrated that the improved shear strength equations are needed to consider reduction of shear strength in PC modules.
        4,000원
        3.
        2019.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Diagonally reinforced concrete coupling beams (DRCBs) have been widely adopted in reinforced concrete (RC) bearing wall systems. DRCBs are known to act as a fuse element dissipating most of seismic energies imparted to the bearing wall systems during earthquakes. Despite such importance of DRCBs, the damage estimation of such components and the corresponding consequences within the knowledge of performance based seismic design framework is not well understood. In this paper, drift-based fragility functions are developed for in-plane loaded DRCBs. Fragility functions are developed to predict the damage and to decide the repair method required for DRCBs subjected to earthquake loading. Thirty-seven experimental results are collected from seventeen published literatures for this effort. Drift-based fragility functions are developed for four damage states of DRCBs subjected to cyclic and monotonic loading associated with minor cracking, severe cracking, onset of strength loss, and significant strength loss. Damage states are defined in a consistent manner. Cumulative distribution functions are fit to the empirical data and evaluated using standard statistical methods.
        4,000원
        4.
        2018.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Diagonally reinforced concrete coupling beams (DRCB) play an important role in coupled shear wall systems since these elements dissipate most of seismic input energy under earthquake loading. For reliable seismic performance evaluation using nonlinear response history analysis, it is important to use an accurate analytical model for DRCBs. In this study, the Pinching4 model is used as a base model to simulate the cyclic behavior of DRCBs. For simulating the cyclic behavior of DRCBs using the Pinching4 model, the analytical parameters for backbone curve, pinching and cyclic deterioration in strength and stiffness should be computed. To determine the proper values of the constituent analytical parameters efficiently and accurately, this study proposes the empirical equations for the analytical parameters using regression analyses. It is shown that the hysteretic behavior of coupling beams can be simulated efficiently and accurately using the proposed numerical model with the proposed empirical equations of model parameters.
        4,000원
        5.
        2017.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The coupled shear wall system with coupling beams is an efficient structural system for high-rise buildings because it can provide excellent ductility and energy dissipation to the buildings. The objective of this study is to simulate the hysteretic behavior of diagonally reinforced concrete coupling beams including pinching and cyclic deteriorations in strength and stiffness using a numerical model. For this purpose, coupling beams are modeled with an elastic beam element and plastic spring element placed at the beam ends. Parameters for the analytical model was calibrated based on the test results of 6 specimens for diagonally reinforced concrete coupling beams. The analytical model with calibrated model parameters is verified by comparing the hysteretic curves obtained from analysis and experimental tests.
        4,000원
        6.
        2016.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Coupling beams serve as primary source of energy dissipation in coupled shear wall systems during large earthquakes. However, the overestimation of the shear strength of diagonally reinforced coupling beams may be adverse effect on the seismic performance of coupled shear wall systems. In order to force coupling beams to properly work during earthquakes, coupling beams should be designed with accurate shear strength equations. The objective of this study is to propose the accurate shear strength equation for slender diagonally reinforced coupling beams. For this purpose, experimental tests were conducted using three diagonally reinforced coupling specimens with different amount of transverse reinforcement under reversed cyclic loads to evaluate the hysteretic behavior of the specimens. The test results show that transverse reinforcement of slender diagonally reinforced coupling beam affects the maximum strength and drift ratio.
        4,000원
        7.
        2015.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Shear wall systems behave as individual wall because of openings like window and elevator cage. When coupling beams are installed in shear walls, they will have high strength and stiffness so that be less damaged by lateral loads like earthquake. However, coupling beam is difficult construction method. And arranging reinforcement of slender coupling beams are especially hard. It is because the details of coupling beam provided by ACI 318 are complex. In this paper, experiments were conducted using coupling beams with 3.5 aspect ratio to improve the details of slender coupling beams provided by ACI 318. Two specimens were proposed for this study. One specimen applied with bundled diagonally reinforcement only. Another specimen applied both bundled diagonally reinforcement and High-Performance Fiber Reinforced Cementitious Composite (HPFRCC) so that coupling beams have half of transverse reinforcement. All specimen were compared with a coupling beam designed according to ACI 318 and were evaluated with hysteretic behaviors. Test results showed that the performance of two specimen suggested in this study were similar to that of coupling beam designed according to current criteria. And it was considered that simplification of the details of reinforcement would be available if transverse reinforcement was reduced by using bundled diagonally reinforcement and HPFRCC.
        4,000원
        8.
        2014.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Diagonal reinforced coupling beam of coupled shear walls can provide sufficient strength and stiffness to resist lateral force. However, the reinforcement details for coupling beams required by ACI 318 (2011) are difficult to construct because of the reinforcement congestion and confined interior area. This study presents experimental results about the seismic performance of coupling beams having bundled diagonal reinforcement to improve the workability. Experiments were conducted using half scaled precast coupling beams having an aspect ratio of 2.0. It was observed that the bundled diagonal reinforced coupling beams can develop seismic performance similar to the coupling beams with requirement details specified in ACI 318 (2011).
        4,000원
        9.
        2013.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The hysteretic behavior of diagonal reinforced coupling beams is excellent during earthquakes. However, construction of the diagonal reinforced coupling beams is difficult due to complex reinforcement details required by current code procedures (ACI 318-11). Due to the detail requirement, reinforcement congestion and interference among transverse reinforcement always occur during construction field. When the aspect ratio of the beam is large, the interference of reinforcement becomes more serious. The objective of this paper is to simplify the reinforcement details of slender coupling beams by reducing transverse reinforcement around the beam perimeter. For this purpose, high- performance fiber reinforced cementitious composites are used for making coupling beams. Experiments were conducted using three specimens having aspect ratio 3.5. Test results showed that HPFRCC coupling beams with half the transverse reinforcement required by ACI 318-11 provided identical seismic capacities to the corresponding coupling beams having requirement satisfying the requirement specified in ACI 318-11.
        4,000원
        10.
        2012.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 내력벽 시스템에 대하여 연결보의 단부에 적용이 가능한 박판형 금속감쇠기의 성능을 실험을 통하여 규명하고자 하였다. 박판형 금속감쇠기의 박판 두께와 길이를 변수로 하여 5개 시험체를 제작하였으며, 층간변위비 5%까지 반복하여 횡력을가력하였다. 실험결과, 금속 박판에 좌굴발생 후 소성변형이 발생하면서 에너지 발산이 이루어졌으며, 기존의 일반 콘크리트 시험체보다에너지 발산량이 크게 나타났다. 박판의 길이가 짧을수록 전단내력의 값은 증가하였으나 발산에너지의 양의 증가는 크게 나타나지 않았다. 실험 내력을 탄성좌굴해석과 비교한 결과, 해석에 의한 내력은 내력곡선 선형영역의 최대값을 적절히 예측함을 알 수 있었다.
        4,000원
        11.
        2009.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 반복 횡하중 하에서의 기둥부재와 보-기둥 연결부에 대한 구조 성능 확인을 위하여 기 수행된 실험을 토대로 해석모델을 수립하고 사용 프로그램의 유용성과 실용성을 평가하는 것을 목적으로 하였다. 기존 연구자들에 의해 제안된 콘크리트와 철근의 이력 모델을 비선형 해석 프로그램인 PERFORM3D에 적용하여 수행되었다. 결과로서, 반복 횡하중 하의 비보강 보-기둥 연결부재의 해석과 실험결과가 비교적 일치함을 확인하였다. 이로써 입증된 비보강 시험체의 해석 모델에 탄소와 아라미드 섬유시트 그리고 비좌굴 가새를 추가 적용하여 실험결과와 비교.검증하여 내진 성능 보강의 해석모델을 수립하였다. 이는 기존 구조물에 대한 보강에 있어서, 해석을 통한 사전 성능 검토에 활용함으로써 시간과 물질적 측면에서의 경제성 도모에 기여할 것으로 예상된다.
        4,000원
        12.
        2009.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구의 목적은 일정 축하중과 반복횡하중 하에서 탄소섬유시트와 비좌굴 가새로 보강된 보-기둥 시험체의 횡방향 거동 평가를 통하여 사용된 보강 방법의 구조적 성능을 검증하는 것이다. 세 개의 시험체를 비보강, 탄소섬유보강, 탄소섬유와 비좌굴 가새 보강 방법을 각각 적용하여 제작하였다. 변위에 따른 최대, 최소하중은 하중-변위 관계를 분석함으로써 평가되어지며, 하중과 강성의 관계는 비교구간의 유효강성 분석에 의해 평가된다. 실험의 수행 결과, 보강을 하지 않은 시험체에 비하여 보강을 적용한 시험체는 최대허용하중과 유효강성, 철근 항복 시 재하 횡하중, 변위연성비 등에서 상대적으로 우수한 성능을 보였다.
        4,000원
        13.
        2006.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        콘크리트 부재의 내진설계에 있어 강도와 더불어 변형 능력은 중요한 요소이다. 연결보는 전단 지배 부재임에도 항복 이후 소성 변형을 요구하는 부재인데 본 연구에서는 연결보의 변형 능력에 대한 실험을 통해 변형 모형을 제시하였다. 일반적인 배근 형태를 가진 철근 콘크리트 연결보를 대상으로 단조하중실험을 수행하였다. 경간-깊이비, 휨 철근비, 전단 철근비를 변수로 하여 연결보의 거동을 평가하였다. 전단 지배 부재인 연결보는 아치작용과 트러스 작용으로 전단력에 대해 저항하는데 실험 결과를 통해 전단력을 두 작용의 구분과 항복 강도 발현 이후 소성 변형에 따른 두 작용의 구성비 변화에 대해 분석하였다. 실험결과에 기초한 전단 철근과 휨 철근의 변형률 분포 모형을 이용하여 휨 철근의 응력 상태를 산정하였다. 휨 철근의 부착-미끄러짐에 의해 결정되는 균열폭을 고려하는 연결보의 변형 모형을 제시하였다. 항복 상태는 휨 철근의 항복 시점으로 정의하였고, 극한 상태는 변형 증가에 따른 스트럿의 압축 강도 저하에 의해 결정되었다. 이 변형 모형은 변위기초설계에 활용될 수 있을 것으로 기대된다.
        4,200원
        14.
        2018.05 KCI 등재 서비스 종료(열람 제한)
        국내 공동주택 전단벽 구조시스템에 적용되는 감쇠장치는 대부분 인방형 형상으로 적용되고 있다. 인방형 감쇠장치는 좌우 전단벽을 연결하여 커플링 효과 및 추가 감쇠효과를 발휘하여 구조물 내진성능을 증대시킨다. 본 연구에서는 인방형 감쇠장치를 소개하고 감쇠장치가 적용된 구조물의 거동특성을 파악하였다. 제안된 감쇠장치는 힌지 및 변단면 형상으로 감쇠효과를 극대화시킨 구조로 유한요소 해석결과와 실험결과가 잘 일치하여 우수한 내진성능을 발휘하는 것으로 나타났으며, 해당 감쇠장치가 적용된 2차원 및 실제 공동주택 구조물을 대상으로 감쇠효과를 검토한 결과, 감쇠장치 커플링 효과로 기존구조물 대비 모든 구조물에서 내진성능 향상을 도모할 수 있었다. 본 연구에서 검토한 실제 구조물에 대해서는 비선형 정적해석 결과, 강도 및 연성능력이 향상되는 것으로 나타났고, 비선형 동적해석 결과, 층간변형각이 15%~18%, 층가속도가 20%~28%, 밑면전단력이 15%~20% 감소하는 결과를 나타냈다.
        16.
        2017.03 KCI 등재 서비스 종료(열람 제한)
        This paper describes the experimental results for the structural performance of full-scale coupling beams with different reinforcement layout (diagonal and horizontal). For the reinforcements of the coupling beams, high-strength steel bars(SD500 and SD600) were used in order to improve workability and economic feasibility. The rigid steel frames and linked joints were used to maintain the clear span length (distance between both shear walls) of the coupling beam during the cyclic loading. Experimental results indicated that the diagonally reinforced coupling beam specimen could exhibit more ductile behavior compared to horizontally reinforced specimen. ACI318-14 code is applicable to design of coupling beam with diagonally reinforcement, however, that is overestimating the strength of horizontally reinforced coupling beam. It is remarkable that effective elastic stiffness values of both reinforcement details coupling beam significantly lees than ASCE 41-13.
        20.
        2016.10 서비스 종료(열람 제한)
        In recent year to improve the seismic behavior of conventional link beams, some efforts have been made by providing special reinforcement material, or using steel link beams as substitutes. In this study to facilitate the constructability and meanwhile ensure desirable seismic behavior, an innovative type of replaceable steel frame link beam was conceived and studied
        1 2