Restraints of Branch Lines are used as earthquake-resistant support devices for fire-fighting pipes along with sway brace devices. The central types are aligned and fixed in a straight line with center of the pipe, but the eccentric types are fixed to on side of the pipe, so a bending moment occurs. In this study, three specimens each of central type and eccentric type were installed at an angle of 45° from the vertical and a monotonic compression load of 1340N was applied. All central type samples satisfied 17.8mm of the allowable displacement, but all eccentric type samples failed to meet the target load and buckled. Therefore, when considering the performance of eccentric type restraints, both compressive load and bending moment must be considered. Even through material mechanics calculations, the yield stress of eccentric type - 3/8 inch all threaded steel bolt - exceeds 320Mpa of the allowable stress. A experiment standards need to be established for eccentric type restraints.
In this study, a prefabricated buckling brace (PF-BRB) was proposed, and a test specimen was manufactured based on the design formula for the initial shape and structural performance tests were performed. As a result of the experiment, all standard performance requirements presented by KDS 41 17 00 and MOE 2021 were satisfied before and after replacement of the reinforcement module, and no fracture of the joint module occurred. As a result of the incremental load test, the physical properties showed a significant difference in the stiffness ratio after yielding under the compressive load of the envelope according to the experimental results. It is judged necessary to further analyze the physical properties according to the experimental results through finite element analysis in the future.
This study is conducted to verify the seismic reinforcement effects of internally inserted buckling-restrained braces supported laterally by buckling-restrained rings for the seismic reinforcement of existing reinforced concrete buildings with non-seismic details. First, to evaluate the performance of KDS, the hysteretic characteristics of buckling-restrained braces are verified, and it is discovered that they satisfy the conformance criteria of the displacement-dependent damping device. Three full-scale, two-story reinforced concrete framework specimens are prepared to verify the seismic reinforcement effects, and the proposed buckling-restrained braces are bolstered with single diagonal and V-shaped braces to be compared with non-reinforced specimens. By performing a comparison with non-reinforced specimens that present intensive shear cracks at the bottom of first-floor columns, it is revealed that the maximum load and energy dissipation of specimens reinforced with the proposed buckling restrained braces, in which the structural damage extends evenly throughout the system, are approximately 4 and 6.2 times higher, respectively, which proves the effectiveness of the proposed seismic reinforcement method.
In this study, the Buckling restrained braces reinforced with engineering plastics that can compensate for the disadvantages in the manufacturing process of the existing buckling restrained brace. The proposed PC-BRB was fabricated to evaluate the reinforcement effect by carrying out a structural performance test and a full-scale two-layer frame test through cyclic loading test. As a result of PC-BRB's incremental and cyclic loading test, stable hysteresis behavior was achieved within the target displacement, and the compressive strength adjustment coefficient satisfied the recommendation. As a result of the real frame experiment, the strength of the reinforced specimen increased compared to the unreinforced specimen, and the ductility and energy dissipation increased.
The seismic design range for the national public facilities and power plant is expanded such as it becomes the earthquake Disaster Relief Act with the finance since 2008 as the seismic design concept is highly regarded, etc. The reinforcement of the brace is essential for the seismic performance security of the structure which is unable to be satisfied the current seismic design criteria. The tension brace in which the slenderness ratio is big was designed to the unique lateral force resistive element. And the buckling is generated in the first stage and it is unable to exhibit the structural capability. In this research, the buckling strength improvement the reinforcing method of the suggested tension brace tries to be verified through the experiment.
This study aims at developing a new shape damper and suggestion for seismic silo structure, which contribute to increase significantly seismic performance and constructional efficiency. The suggested N.B.B.D system is more likely to adoptable because it remarkably contribute to save inter-story drift also to have many advantages compared with conventional X or K type braced frame.
FRP Sheet와 비좌굴가새를 적용한 보-기둥 접합부의 보강효과를 평가하기 위하여 보-기둥 접합부 실험체에 축력 및 반복 횡가력을 가하여 실험을 수행하였다. 동일한 크기의 6개의 실험체를 제작하였으며 FRP Sheet의 종류 및 비좌굴 가새의 유무를 변수로 하였다. 실험체의 파괴양상 및 최대하중, 연성지수, 에너지소산능력의 측면에서 실험결과를 분석하였다. 실험결과 CFRP Sheet와 비좌굴가새를 혼용한 보강방법이 가장 우수한 성능을 나타냈다.
본 연구에서는 1층 1경간 실제크기의 가력 프레임에서 내진보강에 적합한 비좌굴 knee brace을 설치하여 주기하중을 통해 가새의 지진저항능력을 실험하였다. 볼트 고정 채널이 이용된 비좌굴 knee brace는 지진력에 저항하는 코어와 두 개의 철골 플레이트로 만들어졌고 단면의 형태는 코어의 국부좌굴과 횡좌굴에 저항하도록 하였다. 비좌굴 kneebrace는 현장에서 조립이 용이하고, 시공방법 또한 간단하여 공간에 제약이 있는1층에 필로터를 가진 중저층 RC건물의 내진 보수/보강에 효과적으로 사용할 수 있다. 각 실험체에 대한 변수로 중심코어의 크기와 외부 보강재의 크기, 가이드 플레이트의 유무 등으로 정하였으며, 실험을 통해 얻어진 힘-변위 이력곡선을 통해 중심코어의 크기가 가장 큰 영향을 미치는 것으로 나타났다. 또한 가이드 플레이트의 유무에 따라 압축강도 수정계수와 파괴형태가 달라지는 것을 알 수 있었다. 각 실험체에 대한 결과는 AISC 2005 Seismic Provisions 규정에서 제시한 누적 연성도와 누적 소산에너지 측면에서도 충분한 효과를 발휘하는 것으로 나타났다.
본 연구의 목적은 일정 축하중과 반복횡하중 하에서 탄소섬유시트와 비좌굴 가새로 보강된 보-기둥 시험체의 횡방향 거동 평가를 통하여 사용된 보강 방법의 구조적 성능을 검증하는 것이다. 세 개의 시험체를 비보강, 탄소섬유보강, 탄소섬유와 비좌굴 가새 보강 방법을 각각 적용하여 제작하였다. 변위에 따른 최대, 최소하중은 하중-변위 관계를 분석함으로써 평가되어지며, 하중과 강성의 관계는 비교구간의 유효강성 분석에 의해 평가된다. 실험의 수행 결과, 보강을 하지 않은 시험체에 비하여 보강을 적용한 시험체는 최대허용하중과 유효강성, 철근 항복 시 재하 횡하중, 변위연성비 등에서 상대적으로 우수한 성능을 보였다.
대공간 구조형식에는 기존의 기둥-보 구조형식에서 벗어나 쉘구조형식과 같은 형태저항 구조형식이 가장 유효한 구조형식으로 인식되고 있다. 특히 지간 200m~300m 이상의 대공간구주 형식으로는 중량구조인 연속체의 쉘보다는 래티스 돔과 같은 공간 트러스형식 등의 유리하다. 시공, 제작상의 편리성, 구조미 등을 이유로 복층래티스 돔과 더불어 단층의 래티스 돔 형식도 실제 구조물에서 많이 적용되고 있다. 그러나 대공간 단층 래티스 돔의 경우 아직까지 외력의 작용으로 인한 변형과 파괴경로가 명확하게 해명되지 못한 부분이 있다. 본 연구에서는 대공간 구조형식에 적합한 래티스 돔을 대상으로 좌굴의 특성을 규명하여 안정적인 구조 설계의 기초 자료를 제시하기 위하여 실험을 수행하였다. 주된 실험변소는 격자의 간격과 돔의 지붕 강성 유무를 대상을 하였으며, 격자의 간격은 돔을 4분할, 5분할, 6분할, 7분할로 하여 정하였다. 가력은 돔의 전면에 걸쳐 구심의 등분포하중이 작용하도록 하였다.
This study designs RC frame specimens with existing brace retrofit system and conduct experiment. Using the resultant data, it try to analyze structural performance of the brace system and suggests preliminary data for new shape buckling-restrained braces.
비탄성 구간 내 비지지 길이가 존재하는 휨부재의 극한거동특성을 자세히 살펴보면, 단면 내 비균일 항복응력 도달로 인하여 초기의 이축 대칭단면이 일축대칭으로, 최종적으로는 비대칭단면의 특성을 보이게 된다. 이러한 극한거동에 대한 해석적 연구결과의 실험적 검토는 개발된 설계식의 상용화를 위해서 필연적으로 수행되어야 한다. 일반적으로 사용되는 구조용 강재를 이용한 실험연구는 재료비 및 실험장비 사용에 있어 많은 비용을 유발하므로 본 연구에서는 연구대상 구조부재의 거동특성을 파악할 수 있는 소규모의 경제적인 재료사용과 실험 상황을 구현하여 소규모 실험실에서 모형실험을 실시하였다.
유한요소해석프로그램인 ABAQUS를 사용하여 실험체의 극한강도를 산정하고, 기존에 개발된 제안식과의 비교를 통하여 I형 양단 스텝보의 비탄성 횡-비틀림 좌굴 강도 간편 설계식의 적용성을 평가하였다. 유한요소해석결과와 실험결과는 9%의 차이를 보이고 있으며, 제안식과 실험결과는 7%의 차이를 보이고 있다. 향후 추가적인 실험연구를 통하여 간편 제안식의 적절성을 추가적으로 평가할 예정이다.
강구조물은 주로 도장에 의해 방식처리 되고 있지만, 장기간 사용함에 따라 강재표면에 부식손상이 발생하게 된다. 이러한 부식손상은 단면감소와 이로 인한 좌굴내하력을 저하시킬 우려가 있다. 현재 다양한 등단면형상과 지지조건에 대한 좌굴강도 추정식 및 설계식이 제안되어 있으나, 부식손상으로 인한 불규칙한 변단면 강부재의 축압축 좌굴강도 평가법은 아직 확립되어 있지 않다. 본 연구에서는 부식 손상된 가시설 강부재에서 절취한 강재시편의 축압축 좌굴실험을 실시하여, 부식강재의 좌굴강도 평가에 대한 기초적 연구를 수행하였다. 본 실험에서는 먼저 가시설 주형보의 웨브로부터 시편 지지길이를 200, 300, 400, 500, 600mm로 달리한 5종류 시편을 각각 2개씩 총 10개의 강재시편을 절취하고, 화학적 방법에 의해 녹을 제거하였다. 그리고 3차원 광학 스캐너를 이용하여 1×1mm 간격으로 표면형상을 측정하여, 각 시편의 잔존두께를 산출하였다. 그리고 10개의 부식 손상된 시편과 부식 손상되지 않은 무부식 시편 12개를 양단 완전고정지지 조건하에서 축압축 좌굴실험을 실시하여, 부식두께감소량 및 시편의 표면형상과 축압축 좌굴강도와의 상관관계를 분석하였다. 그 결과, 부식 손상정도에 상관없는 무부식 등단면 강재와 동일하게 좌굴강도를 평가할 수 있는 불규칙 변단면 부식강재의 폭방향평균 최소두께 또는 평균잔존두께와 표준편차의 차로 계산되는 유효두께를 적용하여 축압축 좌굴강도을 추정할 수 있음을 제안하였다. 또한 이러한 결과를 실무에도 적용할 수 있도록 실용적인 부식강재의 잔존두께 측정간격도 제시하였다.
본 연구에서는 원형강관 가새의 국부좌굴에 의한 내력감소를 배제하기 위하여, 가새의 국부좌굴 거동을 파악하고 좌굴제어 방법을 찾고자 한다. 좌굴을 제어하기 위한 방법으로, 하나는 좌굴 영역에 커버플레이트를 설치하여 좌굴을 구속함으로써 변형능력을 확보하고자 하는 것이며, 다른 하나는 가새 중앙부에 강봉과 스프링을 이용한 수축장치를 삽입하여 압축 시 좌굴의 위험을 배제하는 것이다. 본 연구의 목적은 국부좌굴을 구속하거나 배제하기 위한 좌굴제어시스템을 제안하고, 실험을 통하여 제안한 방법의 적용성을 조사, 검토하는 것이다. 또한 좌굴제어에 따른 성능향상을 정량적으로 평가하는 것이다.