검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 58

        1.
        2024.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Earthquakes of magnitude 3.0 or greater occur in Korea about 10 times on average yearly, and the number of earthquakes occurring in Korea is increasing. As many earthquakes have recently occurred, interest in the safety of nuclear power plants has increased. Nuclear power plants are equipped with many cabinet-type control facilities to regulate safety facilities, and function maintenance is required during an earthquake. The seismic performance of the cabinet is divided into structural and functional performances. Structural performance can be secured during the design procedure. Functional performance depends on the vibration performance of the component. Therefore, it is necessary to confirm the seismic performance of the components. Generally, seismic performance is confirmed through seismic simulation tests. When checking seismic performance through seismic simulation tests, it is difficult to determine the effect of frequency and maximum acceleration on an element. In this paper, shaking table tests were performed using various frequencies and various maximum accelerations. The seismic performance characteristics of the functions of electrical equipment components were confirmed through tests.
        4,000원
        2.
        2022.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, 3D design, vibration analysis and experiment, and feed rate performance test were performed to develop a vibratory bowl feeder for supplying ultra-thin plate parts of less than 50 microns. The natural frequency and resonant frequency of the vibratory bowl feeder were obtained through the vibration analysis and experiment, and it was confirmed that the results of the analysis and experiment agree well. Through the feed rate experiment, it was confirmed that up to 610 ultra-thin parts per minute were fed at 250Hz and a supply voltage of 220V, where the excitation frequency and the resonant frequency match. And through analysis and experimental research, it was confirmed that the development of a vibratory bowl feeder for supplying ultra-thin parts was successful.
        4,000원
        3.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        기계 장비의 진동 데이터는 필연적으로 노이즈를 포함하고 있다. 이러한 노이즈는 기계 장비의 유지보수를 진행하는데 악영향 을 끼친다. 그에 따라 데이터의 노이즈를 얼마나 효과적으로 제거해주냐에 따라 학습 모델의 성능을 좌우한다. 본 논문에서는 시계열 데 이터를 전처리 함에 있어 특성추출 과정을 포함하지 않는 Denoising Auto Encoder 기법을 활용하여 데이터의 노이즈를 제거했다. 또한 기계 신호 처리에 널리 사용되는 Wavelet Transform과 성능 비교를 진행했다. 성능비교는 고장 탐지율을 계산하여 진행했으며 보다 정확한 비교 를 위해 분류 성능 평가기준 중 하나인 F-1 Score를 계산하여 성능 비교를 진행했다. 고장을 탐지하는 과정에서는 One-Class SVM 기법을 활용하여 고장 데이터를 탐지했다. 성능 비교 결과 고장 진단율과 오차율 측면에서 Denoising Auto Encoder 기법이 Wavelet Transform 기법 에 비해 보다 좋은 성능을 나타냈다.
        4,000원
        4.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        부공력감쇠는 풍직각방향의 와류공진을 예측하는데 있어서 매우 중요한 요소이다. 부공력감쇠는 진동유발하중 또는 피드백 하중을 구성하는 주요인자로 와류진동이 급격히 발현되는 현상을 설명하는 도구이기도 하다. 본 연구에서는 공력감쇠의 수학적 모델 을 제시하고 와류유발하중모델과 함께 와류진동을 예측하는 프러세스를 제안한다. 직사각형단면에 대한 공기력진동실험을 수행하여, 계측된 가속도로부터 공력감쇠와 와류유발하중을 추정하고 이에 기반하여 공력감쇠모델과 와류유발하중모델을 구축하는 과정을 다룬 다. 최종적으로 공력감쇠모델과 와류유발하중 모델에 대한 재해석을 통하여 가속도응답을 구하고 계측된 가속도와 비교하여 모델의 진동예측성능을 평가한다. 본 연구에서 제안된 와류하중모델의 진동예측성능을 평가한 결과 안정적이며, 신뢰도가 높은 와류진동예측 이 가능함을 알 수 있었다.
        4,000원
        5.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 유기농산물에 대한 선호가 증가하고 있다. 유기농산물 생산에 있어 물리적 제초는 필수적이다. 하지만, 국내 밭 제초작업 기계화율은 60% 미만으로 낮으며, 농촌 인구의 고령화·여성화로 소형 제초기의 개발이 필요하다. 또한, 제초기의 경우 사용자가 반복적 진동에 노출되기 때문에 이를 절감할 수 있는 노력이 필요하나, 이에 대한 연구는 미흡한 실정이다. 따라서, 본 연구에서는 여성·고령 농업인도 사용하기 편리한 전동 배부식 중경제초기를 개발하는 데 있어 수평 회전식 원판에 부착된 제초날의 형상(원형, 삼각형, 일자형) 및 폭(15, 20, 25mm)에 따른 제초성능 및 ISO5349-1에 따라 손에 전달되는 진동을 분석하였다. 제초율은 원형 제초날에서 90.4~96.4%로 가장 높게 나타났으며, 진동 또한 원형 제초날을 사용하였을 때 사용자의 10%가 수지백증이 발병하는데 걸리는 시간이 20년 내외로 삼각형 및 일자형 제초날을 사용했을 때 보다 200% 가량 증가하는 것으로 나타났다. 따라서, 원형 제초날을 사용하였을 때 진동을 감소시킬 수 있으며, 불필요한 반력을 줄여 높은 제초효과를 볼 수 있을 것으로 판단된다.
        4,000원
        7.
        2021.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        선박 및 해양구조물과 같은 대형 유한요소모델의 진동 특성을 평가하기 위해 고유치 해석 및 가진 주파수에 따른 응답 계산을 필수적으로 수행해야 한다. 하지만 이러한 해석들은 과도한 전산 장비와 계산 시간이 요구되어 고성능 해석 프로그램의 개발이 필요하다. 특히 선형연립방정식에서 발생하는 역행렬 계산 및 고유치 해석 시에는 상당한 전산 해석 시간이 발생하기 때문에 최신 고성능 라이브러리를 적용함으로써 이를 개선할 수 있다. 본 연구에서는 병렬식 선형연립방정식 계산 라이브러리인 PARDISO와 고성능 고유치 해석 라이 브러리인 ARPACK을 적용하여 빠르고 정확한 해석이 가능한 진동해석 프로그램을 개발하였다. 끝으로 개발된 해석 프로그램의 정확도와 효율성을 검증하기 위해 여러 선박해양공학 수치 예제를 사용하였고, 상용 유한요소 프로그램인 ABAQUS와의 결과 비교 검토를 통해 개발된 진동해석 프로그램의 신뢰성을 검증, 제시하였다.
        4,000원
        8.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A new lighting support structure composing of two-way wires and pulley, a pulley-type wireway system, was developed to improve the seismic performance of a ceiling type lighting equipment. This study verifies the seismic performance of the pulley-type wireway system using a numerical approach. A theoretical model fitted to the physical features of the newly-developed system was proposed, and it was utilized to compute a frictional coefficient between the wire and pulley sections under tension forces. The frictional coefficient was implemented to a finite element model representing the pulley-type wireway system. Using the numerical model, the seismic responses of the pulley-type wireway system were compared to those of the existing lighting support structure, a one-way wire system. The addition of the pulley component resulted in the increasement of energy absorption capacity as well as friction effect and showed in significant reduction in maximum displacement and oscillation after the peak responses. Thus, the newly-developed wireway system can minimize earthquake-induced vibration and damage on electric equipment.
        4,000원
        9.
        2020.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In 2016, an earthquake occurred at Gyeongju, Korea. At the Wolsong site, the observed peak ground acceleration was lower than the operating basis earthquake (OBE) level of Wolsong nuclear power plant. However, the measured spectral acceleration value exceeded the spectral acceleration of the operating-basis earthquake (OBE) level in some sections of the response spectrum, resulting in a manual shutdown of the nuclear power plant. Analysis of the response spectra shape of the Gyeongju earthquake motion showed that the high-frequency components are stronger than the response spectra shape used in nuclear power plant design. Therefore, the seismic performance evaluation of structures and equipment of nuclear power plants should be made to reflect the characteristics of site-specific earthquakes. In general, the floor response spectrum shape at the installation site or the generalized response spectrum shape is used for the seismic performance evaluation of structures and equipment. In this study, a generalized response spectrum shape is proposed for seismic performance evaluation of structures and equipment for nuclear power plants. The proposed response spectrum shape reflects the characteristics of earthquake motion in Korea through earthquake hazard analysis, and it can be applied to structures and equipment at various locations.
        4,000원
        10.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 탄소나노튜브/보강섬유/폴리머 복합 쉘에 대한 동적응답을 다루었다. 단일벽 탄소나노튜브, 유리섬유 및 에폭시 레진으로 구성된 3단계 복합구조이며, 유효 물성값은 멀티스케일 해석을 통하여 산정하였다. 유한요소 프로그램인 ABAQUS를 적용하여 다양한 탄소나노튜브 함유비율, 적층각도, 곡률 및 중앙 개구부의 다양한 변화에 대한 동적응답 및 상호 작용을 분석하였다. 본 연구는 원통형 복합쉘의 동적 하중에 의한 처짐을 감소시킬 수 있는 변수들의 중요성을 보여주었다.
        4,000원
        11.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The customer of massage chair is expanding day by day from middle age to all ages. In 2018, the market size was 700 billion KRW, an increase of 30 times over 10 years. However, most related SMEs suffer from excessive competition by the market monopoly of some major companies. In this situation, in order for a related company to survive, it is necessary to steadily research and develop new products. Founded in 2009, company L produces massage chairs for health and relaxation of customers. L’s products use a sound wave vibration module that is favorable for human body, unlike other products that use vibration motor type. However, frequent breakdowns of massage chair due to the vulnerability of plate (leaf) springs, which play an important role in sound wave vibration modules, made sap its competitiveness. In this paper, we propose a method to design desirable plate spring structure by sequentially experimenting with five different plate springs. The results of this study are expected to contribute to improve the quality of plate spring and the reliability of sound wave vibration module. In the future, it is necessary to find a way to use it in the development of foot massage or scalp management device as well as continuous research to find optimal plate spring structure through various analysis.
        4,000원
        12.
        2019.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Wireless sensors are more favorable in measuring structural response compared to conventional sensors in terms of them being easier to use with no issues with cables and them being considerably cheaper. Previous tests have been conducted to analyze the performance of MEMS (Micro Electro Mechanical Systems) sensor in sinusoidal excitation tests. This paper analyzes the performance of in-built MEMS sensors in devices by comparing with an ICP sensor as the reference. Earthquake input amplitude excitation in shaking table tests was done. Results show that MEMS sensors are more accurate in measuring higher input amplitude measurements which range from 100gal to 250gal than at lower input amplitudes which range from 10gal to 50gal. This confirms the results obtained in previous sinusoidal tests. It was also seen that natural frequency results have lower error values which range from 0% to 3.92% in comparison to the response spectra results. This also confirms that in-built MEMS sensors in mobile devices are good at estimating natural frequency of structures. In addition, it was also seen that earthquake input amplitudes with more frequency contents (Gyeongju) had considerably higher error values than Pohang excitation tests which has less frequency contents.
        4,000원
        13.
        2019.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the yaw misalignment value of wind turbine was measured using Lidar and it was analyzed the effect of vibration reduction and power performance improvement when applied to turbine. It was confirmed that the vibration of the main bearing and the gear box of the wind turbine was partially reduced. Also it was found that the output performance was improved when the wind speed was over 8m/s. As a result, it was also found that the annual energy production(AEP) was improved when the average annual wind speed of the wind farm was over 6m/s. Converted to AEP, the AEP improved about 1% and 4%, when the annual wind speed was 6m/s and 11m/s respectively, which resulted in an improvement of about 1~4% through the yaw misalignment correction of the wind turbine.
        4,000원
        15.
        2019.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Micro-Electro-Mechanical Systems (MEMS) sensors have been widely used in Structural Health Monitoring due to their convenience and lower costs in comparison to conventional sensors. Triggered measurements are relevant in events such as earthquakes because unlike continuous measurements, they only record the structural response once an event happens. This is more cost effective and it makes the data more manageable because only the required measurements from the event are recorded. The most common method of triggering is amplitude triggering. However, lower input amplitudes (less than 0.1g) cannot be triggered by using this method. In this paper, sound triggering was introduced to allow triggered measurements for lower input amplitude values. The performance of the sound triggering and amplitude triggering were compared by a series of shaking- table tests. It was seen that sound- triggering method has a wider frequency (0.5~10Hz) and amplitude (0.01~1.0g) range of measurements. In addition, the sound triggering method performs better than the amplitude triggering method at lower amplitudes. The performance of the amplitude triggering, in terms of the triggering being simultaneous improves at higher input amplitudes.
        4,000원
        17.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Wireless sensors are more favorable in measuring structural response compared to conventional sensors. This is because they are easier to use with no issues with cables and are considerably cheaper. There are several applications that can be used in recording and analyzing data from MEMS sensor installed on an iPhone. The Vibration App is one of the applications used and there has not been adequate research conducted in analyzing the performance of this App. This paper analyzed the performance of the Vibration App by comparing it with the performance of an ICP sensor. Results show that natural frequency results are more accurate (error less than 5%) in comparison to the amplitude results. This means that built- in MEMS sensor in smartphones are good at estimating natural frequency of structures. In addition, it was seen that the results became more accurate at higher frequencies (5.0Hz and 10.0Hz).
        4,200원
        18.
        2018.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A base isolation system is widely used to reduce seismic responses of low-rise buildings. This system cannot be effectively applied to high-rise buildings because the initial stiffness of the high-rise building with the base isolation system maintains almost the same as the building without the base isolation system to set the yield shear force of the base isolation system larger than the design wind load. To solve this problem, the mid-story isolation system was proposed and applied to many buildings. The mid-story isolation system has two major objectives; first to reduce peak story drift and second to reduce peak drift of the isolation story. Usually, these two objectives are in conflict. In this study, a hybrid mid-story isolation system for a tall building is proposed. A MR (magnetorheological) damper was used to develop the hybrid mid-story isolation system. An existing building with mid-story isolation system, that is “Shiodome Sumitomo Building” a high rise building having a large atrium in the lower levels, was used for control performance evaluation of the hybrid mid-story isolation system. Fuzzy logic controller and genetic algorithm were used to develop the control algorithm for the hybrid mid-story isolation system. It can be seen from analytical results that the hybrid mid-story isolation system can provide better control performance than the ordinary mid-story isolation system and the design process developed in this study is useful for preliminary design of the hybrid mid-story isolation system for a tall building.
        4,000원
        19.
        2018.04 구독 인증기관 무료, 개인회원 유료
        Since the 2010 year, an occurring number of grand scale earthquakes which above magnitude 5.0 have increased in the world. Many types of research that deal with reducing the damage to the structure from a large-scale earthquake have proceeded. A system which could mitigate strong vertical earthquake's acceleration might apply to structure, since big earthquake cases that occurred lots of loss in Tokyo and Kobe of Japan. A plenty of bearings have installed to mitigate vibration but many parts of these lack efficient ability what we want. In addition, former vertical isolation bearings to apply for the structure have both price and size limits according to material characteristics. Therefore, this paper proposes a new type of device that is made by utilized engineering plastic and improves hitherto used vertical isolation bearing's fault.
        3,000원
        20.
        2018.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, we conducted a shake table test to verify the seismic performance of the paneling system with steel truss composed of bolt connections. The control group was set to the traditional paneling system with steel truss connected by spot welding method. Test results showed that the bolted connection type paneling system has excellent deformation capacity without cracking or brittle fracture of the steel truss connection parts compared to the welding type paneling system. Furthermore, in the bolted connection type, slight damage occurred at the time of occurrence of the same story drift angle as compared with the existing method, it is considered that it has excellent seismic performance. In compliance with the performance-based design recommended for the current code (ASCE 41-13) on non-structural components, it is judged that in the case of the bolted connection type paneling system, it can be applied to all risk category structures without restriction. However, in the case of traditional paneling system with spot welding method, it is considered that it can be applied limitedly.
        4,000원
        1 2 3