검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 756

        21.
        2023.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study presents a dry precast concrete (PC) beam-column connection, and its target seismic performance level is set to be emulative to the reinforced concrete (RC) intermediate moment resisting frame system specified in ACI 318 and ASCE 7. The key features include self-sustaining ability during construction with the dry mechanical splicing method, enabling emulative connection performances and better constructability. Test specimens with code-compliant seismic details were fabricated and tested under reversed cyclic loading, which included a PC beam-column connection specimen with dry connections and an RC control specimen. The test results showed that all the specimens failed in a similar failure mode due to plastic deformations in beam members, while the hysteretic response curve of the PC specimen showed comparable and emulative performances compared to the RC specimen. Seismic performance evaluation was quantitatively addressed, and on this basis, it confirmed that the presented system can fully satisfy all the required performance for the intermediate RC moment resisting frame.
        4,000원
        23.
        2023.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, seismic performance evaluation was carried out for eight circular reinforced concrete columns designed seismically by KRTA[1]and KCI[8]. Primary design parameters for such columns included many longitudinal reinforcements, yield strength of reinforcements, the vertical spacing of spirals, aspect ratio, and axial force ratio. The test results showed that all the columns exhibited stable hysteretic and inelastic responses. Based on the test results, drift ratios corresponding to each damage state, such as initial yielding, initial cover spalling, initial core concrete crushing, buckling, and fracture of longitudinal reinforcement and final spalled region, were evaluated. Then, those ratios were compared with widely accepted damage limit states. The comparison revealed that the existing damage states were considerably conservative. This implies that additional research is required for the damage limit states of such columns designed seismically by current Korean design codes.
        4,000원
        24.
        2023.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        강진은 적절한 내진 설계 기술이 적용되지 않으면 건물 붕괴로 인하여 극심한 피해가 발생할 수 있다. 이를 해결할 수 있는 면진 기술은 구조물과 지반 사이에 베어링 장치를 적용하여 지진 에너지를 흡수하고 건물에 전달되는 진동을 감쇠한 다. 본 연구는 고무 마찰 베어링 장치의 구조물 적용성을 검증하고 지진으로부터 안전성을 확보하기 위하여 고무 마찰 베어링 프레임 구조물에 대한 수치해석을 수행하였다. 수치해석 결과로써 최대 지붕 가속도와 총 밑면 전단력이 감소되어 내진 성능을 확인하였다. 또한, 최대 층간 변위 및 최대 잔류 층간 변위에 대한 분석 결과로 프레임 구조물을 경제적 복구 수준의 결과를 도 출하여 고무 마찰 베어링 장치의 우수한 내진 성능을 확인하였다.
        4,000원
        25.
        2023.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 형상기억합금을 이용한 능동구속기법의 콘크리트 기둥 내진보강효과를 실험적으로 평가하였다. 이를 위해 기존 니켈-티타늄계 형상기억합금보다 저렴한 철계 형상기억합금(Fe SMA)을 선정하여 능동구속기법에 적용하였다. 비내진 상세 를 가진 네 개의 동일한 원형 콘크리트 기둥을 제작한 후 기둥 하단부에 각기 다른 외부구속(무구속, CFRP 구속, Fe SMA 구속) 을 적용하였다. 정적수평반복가력실험 결과, 구속이 적용된 모든 기둥은 콘크리트 기둥의 연성적 휨거동을 이끌어내는데 효과 적인 것으로 밝혀졌다. 특히 Fe SMA 구속은 CFRP 구속에 비해 기둥 하단부 소성힌지에서 콘크리트의 박락 및 손상을 줄이는데 더욱 효과적이었다.
        4,000원
        26.
        2023.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        전기 설비는 원자력 발전소와 같은 발전소에서 발전 시스템을 운영하고 시설물 전체의 안전을 유지하는데 중요한 역 할을 한다. 이러한 전기 설비들은 캐비닛 내부에 설치되어 외부의 위험으로부터 보호된다. 캐비닛 자체 구조와 내부의 전기 장 치들의 내진검증은 발전소의 안전한 운영을 위해 필수적이다. 부분 전기 캐비닛의 내진검증 연구들은 진동대 시험에 의존하여 진행되고 있다. 그러나 시험을 기반으로 한 내진검증의 경우 다양한 종류의 전기 캐비닛의 특성을 포함하기에는 한계가 있다. 이러한 문제는 상세 3D 유한요소 모델을 통한 내진 검증평가는 진동대 시험으로 인한 비용 및 시간을 절약할 수 있고 다양한 형태 및 위치의 전기설비 설치에 따른 내부의 응답 민감성을 확인해 볼 수 있다. 본 연구에서는 단문형 전기 캐비닛의 내진응 답에 대한 연구를 실시하였다. 먼저 진동대 시험으로 얻은 모달해석 결과를 바탕으로 ABAQUS software를 통해 구축된 3D 상세 유한요소 모델을 검증하였다. 그리고 캐비닛 내부의 다양한 기기 설치를 모사하기 위해 캐비닛 하부 및 상부 위치에 캐비닛 총 무게의 2%, 4%, 6%의 질량을 유한요소 모델에 추가하였다. 또한 2개의 고주파 지진과 2개의 저주파 지진을 입력 지진으로 선 정하여 캐비닛 내부 기기의 질량 변화에 따른 캐비닛 내부와 외부의 가속도 응답 변화를 분석하였다.
        4,000원
        27.
        2023.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, alternative seismic force-resisting systems for plant structure supporting equipment were designed, and the seismic performance thereof was compared using nonlinear dynamic analysis. One alternative seismic force-resisting system was designed per the requirement for ordinary moment-resisting and concentrically braced frames but with a reduced base shear. The other seismic force-resisting system was designed by accommodating seismic details of intermediate and unique moment-resisting frames and special concentrically braced frames. Different plastic hinge models were applied to ordinary and ductile systems based on the validation using existing test results. The control model obtained by code-based flexible design and/or reduction of base shear did not satisfy the seismic performance objectives, but the alternative structural system did by strengthened panel zones and a reduced effective buckling length. The seismic force to equipment calculated from the nonlinear dynamic analysis was significantly lower than the equivalent static force of KDS 41 17 00. The comparison of design alternatives showed that the seismic performance required for a plant structure could be secured economically by using performance-based design and alternative seismic-force resisting systems adopting minimally modified seismic details.
        4,300원
        28.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 휨 항복 메커니즘을 기반으로 한 강재이력 댐퍼를 제안하기 위한 해석 및 실험적 연구를 수행하였다. 댐퍼는 휨모멘 트에 의한 항복거동을 하도록 설계된 일련의 댐핑 플레이트로 구성된다. 실험 결과와 유한요소해석 결과의 비교를 통해서 본 연구에 서 채택된 해석적 접근방식이 댐핑 플레이트의 형태 및 상세에 대한 민감도 연구를 수행하기에 적절함을 확인하였다. 최초에 제안된 댐퍼는 휨 항복 메커니즘을 기반으로 작동하는 것으로 고안되었으나, 댐핑 플레이트의 인장 거동에 대한 기여도가 상당할 수 있음을 관찰할 수 있었다. 댐핑 플레이트의 두께가 증가함에 따라 휨 항복에 의한 에너지 흡수량이 증가한다. 댐핑 플레이트의 두께가 감소함 에 따라 인장에 의한 댐퍼의 비선형 거동 기여도가 증가하고 좌굴 발생으로 인하여 이력곡선의 형상이 댐퍼로서 불리해진다.
        4,000원
        29.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        대표적인 비구조요소인 배관의 지진에 의한 손상은 관성력과 두 지지점 사이의 위상차에 의해 작용하는 반복하중 그 리고 허용변형량을 초과하는 상대변위 등에 의해 발생할 수 있다. 특히 주요 손상모드는 큰 반복하중에 의한 저주기피로임이 많은 실험적 연구를 통하여 알려졌다. 따라서 과도한 지진변위에 의한 배관의 손상을 방지하기 위하여 지진상대변위가 발생할 수 있는 위치에 지진분리이음 또는 지진분리장치의 적용이 요구된다. 신축관이음 중 하나인 벨로우즈는 지진분리이음으로 적용 할 수 있다. 본 논문에서는 3ply 금속 벨로우즈 신축관이음의 온도차에 의한 내진성능의 변화를 분석하기 위한 실험적 연구를 수행하였다. 상온환경에서 점진증폭 반복하중재하실험을 수행하였으며, -20°C의 저온조건에서 동일한 실험을 수행하고 그 결과 를 비교하였다. 실험 결과로부터, -20°C의 저온환경에서 금속벨로우즈의 변위성능은 약 10% 저하될 수 있음을 확인하였다.
        4,000원
        30.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In SRC column, the closed hoops are applied with the same detail of both 135° standard hooks to expect the same performance as hoops of RC columns. This standard detail is actually complicated to construct, thus, two separating rebars are connected in the form of a square shape and welded over the overlapping section. But this is also complicated in construction practice. Therefore, this study describes experimental results regarding cyclic behaviors shown with alternative hoops cramped by the steel clip type-binding device instead of welding and standard specimen. As a result of the experiment, the specimens with alternative hoops of the SRC column showed comparable performance to the specimens with closed hoops. Therefore, it can be evaluated that the alternative hoops applied with the rebar confinement clips in the SRC column can replace the closed hoop.
        4,300원
        31.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The energy dissipation of inverted V-type eccentric steel braced frames can be achieved through the yielding of a slit link, through yielding of a number of strips between slits when the frame is subjected to inelastic cyclic deformation. On the other hand, the development of seismic resistance system without residual deformation is obtained by applying the superelasdtic shape memory alloy (SMA) material into the brace and link elements. This paper presents results from a systematic three-dimensional nonlinear finite element analysis on the structural behavior of the eccentric bracing systems subjected to cyclic loadings. A wide scope of structural behaviors explains the horizontal stiffness, hysteretic behaviors, and failure modes of the recentering eccentric bracing system. The accurate results presented here serve as benchmark data for comparison with results obtained using modern experimental testing and alternative theoretical approaches.
        4,000원
        32.
        2022.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The columns of older reinforced concrete (RC) buildings generally have limited reinforcement details. Thus, they could be vulnerable to earthquake ground motions, leading to partial or complete building collapse. In this study, high-performance fiber-reinforced cementitious composite (HPFRCC) was applied to RC columns to improve their seismic behavior. Experimental tests were conducted with two full-sized specimens with limited reinforcement details, including short lap splices, while unidirectional loadings were applied to the specimens. The seismic behavior of RC columns was substantially improved by using HPFRCC.
        4,000원
        33.
        2022.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Unlike the CFT retrofit method, The EPFT retrofit method, which fills the steel tube with engineering plastic, does not require a separate concrete forming work and is a lightweight seismic Retrofit Method. In this study, an prototype model of the EPFT was proposed, and to analyze the seismic performance, an independent specimens and a reinforced concrete column were fabricated to conduct a seismic performance test. As a result of loading test of the independent specimens, the strength was increased compared to the steel tube column without internal filling, and the ductility ratio did not significantly increase due to the falling off of the weld. As a result of loading test of the concrete reinforcement specimen, the strength, ductility ratio, and energy dissipation were increased, and the number of cracks by loading step decreased compared to the non-reinforced specimen.
        4,000원
        34.
        2022.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to evaluate seismic performances of a modular house system developed by a simple 4-clip fastening method and double metal assembly made of lightweight metals. In order to evaluate structural and non-structural seismic performances of the system. Shaking table test was carried out with full-scale modular units, and a nonlinear pushover analysis was performed to obtain suitable seismic responses for story drifts, displacements, force resistances and dynamic properties of the system. Through 3D analysis and shaking table test, the current method of lightweight modular metal unit assembly and systems with seismic performance of a 4-clip fastening type modular house were demonstrated safe and effective to seismic design.
        4,000원
        35.
        2022.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        New buildings have been designed using different seismic design standards that have been revised. However, the seismic performance of existing buildings is evaluated through the same performance evaluation guidelines. Existing buildings may not satisfy the performance targets suggested in the current guidelines, but there are practical limitations to discriminating the existing buildings with poor seismic performance through a full investigation. In this regard, to classify buildings with poor seismic performance according to the applied standard, this study aimed to evaluate performance-based investigation of the seismic design proposals of buildings with different design standards. The target buildings were set as RC ordinary moment frames for office occupancy. Changes in seismic design criteria by period were analyzed, and the design spectrum changes of reinforced concrete ordinary moment resisting frames were compared to analyze the seismic load acting on the building during design. The seismic design plan was derived through structural analysis of the target model, compared the member force and cross-sectional performance, and a preliminary evaluation of the seismic performance was performed to analyze the performance level through DCR. As a result of the seismic performance analysis through the derived design, the reinforced concrete ordinary moment frame design based on AIK 2000 has an insufficient seismic performance level, so buildings built before 2005 are likely to need seismic reinforcement.
        4,000원
        36.
        2022.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 기존 이력댐퍼와 프리스트레트 철계 형상기억합금(Fe SMA)을 결합한 새로운 하이브리드 댐퍼를 제안하고 이용가능성을 해석적으로 평가한다. 하이브리드 댐퍼는 강진 발생 시 모멘트 프레임의 에너지소산능력을 향상시키고 잔류변형 을 감소시키기 위한 목적으로 제안되었다. 구조해석 프로그램인 OpenSees를 통해 댐퍼의 각 요소에 대한 해석모델을 구축하였 고, 세가지 형식의 강재 가새프레임에 대해 시간이력해석을 수행하였다. 해석결과, 제안된 댐퍼는 모멘트 프레임의 최대 및 잔 류변형을 줄이는데 우수한 것으로 나타났다. 본 연구에 사용된 Fe SMA는 니켈-티타늄(Ni-Ti) 형상기억합금에 비해 5-10%에 해 당하는 낮은 재료 비용을 가지면서도 지진에 취약한 프레임 구조의 내진보강에 효과적인 결과를 보였다.
        4,000원
        37.
        2022.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        배관시스템은 대표적인 사회기반시설이다. 지진으로 인한 배관 손상은 심각한 피해를 초래할 수 있으므로 배관시스 템은 지진으로부터 반드시 보호되어야 할 필요가 있다. 지진은 설계기준을 초과하는 상대변위를 동반할 수 있다. 이러한 지진의 거동은 배관 이음부에 손상을 줄 수 있다. 배관시스템에서 과도한 변형이 발생할 수 있는 위치에 지진분리이음을 적용하면 내 진성능을 향상시킬 수 있다. 적층형 금속 벨로우즈는 지진과 같은 저주기 피로 하중에 대한 내구성이 우수하다. 따라서 다중 적층 형 금속 벨로우즈는 파이프의 면진 이음새로 사용할 수 있을 것으로 판단된다. 본 연구에서는 지진분리이음의 하나인 다중 적 층형 금속 벨로우즈에 대한 실험적 연구를 수행하였다. 2종류의 다중 적층형 벨로우즈 신축관이음에 대하여 단조하중 및 반복 하중재하시험을 수행하고 손상모드와 한계상태를 추정하였다. 그리고 단조재하시험과 반복재하시험의 결과를 비교 분석하였다.
        4,000원
        38.
        2022.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study is conducted to verify the seismic reinforcement effects of internally inserted buckling-restrained braces supported laterally by buckling-restrained rings for the seismic reinforcement of existing reinforced concrete buildings with non-seismic details. First, to evaluate the performance of KDS, the hysteretic characteristics of buckling-restrained braces are verified, and it is discovered that they satisfy the conformance criteria of the displacement-dependent damping device. Three full-scale, two-story reinforced concrete framework specimens are prepared to verify the seismic reinforcement effects, and the proposed buckling-restrained braces are bolstered with single diagonal and V-shaped braces to be compared with non-reinforced specimens. By performing a comparison with non-reinforced specimens that present intensive shear cracks at the bottom of first-floor columns, it is revealed that the maximum load and energy dissipation of specimens reinforced with the proposed buckling restrained braces, in which the structural damage extends evenly throughout the system, are approximately 4 and 6.2 times higher, respectively, which proves the effectiveness of the proposed seismic reinforcement method.
        4,000원
        39.
        2022.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 경주, 포항에 연이은 지진 발생으로 인하여 내진설계에 관심이 높아지고 있다. 다가구주택 필로티기둥은 수직 비정형 시스템으로 상,하부층의 강성 차이로 인하여 지진 발생 시 막대한 피해가 예상되기 때문에 다가구주택 필로티기둥의 내 진보강이 필요하다. 그러나 민간 소유인 다가구주택의 경우 막대한 비용과 시간으로 인하여 보강이 어려운 실정이다. 이에 따 라, 복합섬유패널로 에폭시 접착제 미사용으로 건식시공이 가능한 전단보강공법을 제안하고자 한다. 본 연구에서는 복합섬유패 널 보강 유무에 따른 내진보강공법의 전단내력을 실험을 통하여 검증하였고, 에폭시를 사용하지 않아 일체화 거동을 하지는 않 지만 복합섬유패널의 영향으로 전단내력은 1.46∼1.49배 증가하는 것으로 평가되었다. 따라서 다가구주택 필로티기둥의 내진보 강효과가 있을 것으로 판단된다.
        4,000원
        40.
        2022.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study investigated the seismic performance of reinforced concrete (RC) wall-slab frames with masonry infills. Four RC wall-slab frames with or without masonry infill were tested under cyclic loading. The RC frames were composed of in-plane and out-of-plane walls and top and bottom slabs. For masonry infill walls, cement bricks were stacked applying mortar paste only at the bed joints, and, at the top, a gap of 50 mm was intentionally left between the masonry wall and top RC slab. Both sides of the masonry walls were finished by applying ordinary or fiber-reinforced mortars. The tests showed that despite the gap on top of the masonry walls, the strength and stiffness of the infilled frames were significantly increased and were different depending on the direction of loading and the finishing mortars. During repeated loading, the masonry walls underwent horizontal and diagonal cracking and corner crushing/spalling, showing a rocking mode inside the RC wall-slab frame. Interestingly, this rocking mode delayed loss of strength, and as a result, the ductility of the infilled frames increased to the same level as the bare frame. The interaction of masonry infill and adjacent RC walls, depending on the direction of loading, was further investigated based on test observations.
        4,200원
        1 2 3 4 5