        21.
        2018.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper presents the design, analysis, and experimental evaluations of precast reinforced UHPC (ultra high-performance concrete) beams with a new design concept of non-uniform flexural members. With outstanding mechanical properties of UHPC which can develop the compressive strength up to 200MPa, the tensile strengths up to 8~20MPa and the tensile strain up to 1~5%, a non-uniform structural shape of UHPC flexural beams were optimally designed using three-dimensional finite element analysis. The experiments were carried out and compared with the design strength in order to verify the performance of them. Proposed non-uniform UHPC beams were evaluated by a series of three-point beam loading test as well as estimated by design bending and shear strength of members. The newly designed UHPC beams show excellent performances not only in transverse load capacities but also in deformation capacities.
        4,000원
        22.
        2018.04 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to pushover analyze existing reinforced concrete(RC) frames strengthened by L-type precast concrete(PC) wall panels. Cyclic loading tests were performed on the partially infilled reinforced concrete(RC) frames by L-type PC wall panels. Based on the results of experimental test, the nonlinear pushover analysis was practiced by using a computer program. The analysis models were designed with two ways according to the test result. The PC wall panel and the RC column exhibited almost composite behavior by using brace when push loading applied. The two structures also exhibited independent behavior when pull loading applied. The results of pushover analysis models generally conform to the experimental results. The ratios of the maximum lateral load measured in the strengthened specimens from the analysis varied between 0.93 and 1.01 in forward cycles, and between 0.84 and 0.90 in backward cycles. The initial stiffness values of the analysis were less than the test values for all strengthened specimens. The ratio of the initial stiffness obtained through testing compared to the values from the analysis varied between 0.72 and 0.90.
        3,000원
        23.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        When reinforcing an existing reinforced concrete beam-column building with a precast concrete panel, special connection between the PC member and the RC member is required to solve the time dependent deformation of the RC member and to receive the large shear forces. The aim of this study is to obtain the shear strength of upper connection between the existing RC beam-column and infilled PC wall panels in experimentally and theoretically. Thus, the static shear loading tests were conducted on the 6 specimens with the plate connection. Shear failure was resulted from the weakest portion of interior PC panel, exterior RC, and the connection, when the PC portion which located at the center of specimen was pulled upward from the bottom. T he experimental result was compared with analytical result from ACI 318M-14 Chapter 17 for the shear strength of post-installed anchor and PCI Handbook 7th edition 6.8 Structural Steel Corbel (PCI Design Handbook 7th edition, 2010) for the strength of cast-in H-beam. The analytical and experimental results show final failure at the same location. The failure loading of experiment showed larger than average 6% to that of the analysis.
        4,500원
        24.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        As a preparation of a design standard regarding road facilities, such as cantilever columns for traffic lights, optimum design and risk assessment for foundation of street lights on highways are proposed. The preliminary evaluation of optimization with reliability assessment resultantly makes it possible to reduce not only the duration of construction but the cost of construction as well. Ultimate limit states and constraints functions are selected for the sliding, overturning and settlement of the foundation under external loads from super and sub-structures itself. An example foundation under the super structure of height 12m, is optimized as 30% decreased embedded depth of foundation, in which as increasing the depth of embedded connection parts, the necessary depth of foundation is deceased. However, the optimum depths and the reliability indices are sensitively dependent with earth properties and dimensions of foundation.
        4,000원
        25.
        2016.06 구독 인증기관·개인회원 무료
        현 버스전용차로 정차대의 포장 형식으로는 연성포장 형식인 아스팔트 포장이 주를 이루고 있다. 그러 나, 버스전용차로 정차대 특성상 중차량의 반복적인 정지하중에 의해 포트홀 및 소성변형 발생으로 인해 반복적인 재포장을 실시하고 있으며, 이로 인해 폐기물 및 교통통제 등의 사회 간접비용 발생이 크게 증 가되고 있는 실정이다. 현 상황으로 보아 우수한 장기 공용성을 갖는 강성포장 형식의 콘크리트 포장 적 용이 시급한 상황이다. 강성포장 형식으로는 콘크리트의 수축・팽창에 의해 발생될 수 있는 균열에 대응하기 위해 줄눈을 두어 균열을 유도하는 줄눈 콘크리트 포장(JCP, Jointed Concrete Pavement)과 종방향으로 연속철근을 배치 하여 연속체로 거동하며, 자연적인 횡방향 균열의 발생을 허용하는 연속철근 콘크리트 포장(CRCP, Continuously Reinforced Concrete Pavement)이 있다. 본 연구에서는 CRCP 형식의 프리캐스트 콘크 리트 포장 공법을 개발하여 현장에 적용하고, 다년간의 유지관리 데이터 분석을 통하여 현장 적용성 및 공법 개선책 등을 판단하고자 한다. 본 공법은 교통통제 최소화 및 신속한 설치를 위해 공장에서 제작하여 현장에서 설치하는 방법을 선택 하였으며, 운반을 위해 분절된 패널간 연결부에는 루프이음 연결 방법을 적용하여 전체 패널을 일체화 될 수 있도록 하였다.
        26.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to develop a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were experimentally performed on one unreinforced beam-column specimen and two reinforced specimens with L-type precast wall panels. The results were analyzed to find that the specimen with anchored connection experienced shear failure, while the other specimen with steel plate connection principally manifested flexural failure. The ultimate strength of the specimens was determined to be the weaker of the shear strength of top connection and flexural strength at the critical section of precast panel. In this setup of L-type panel specimens, if a push loading is applied to the reinforced concrete column on one side and push the precast concrete panel, a pull loading from upper shear connection is to be applied to the other side of the top shear connection of precast panel. Since the composite flexural behavior of the two members govern the total behavior during the push loading process, the ultimate horizontal resistance of this specimen was not directly influenced by shear strength at the top connection of precast panel. However, the RC column and PC wall panel member mainly exhibited non-composite behavior during the pull loading process. The ultimate horizontal resistance was directly influenced by the shear strength of top connection because the pull loading from the beam applied directly to the upper shear connection. The analytical result for the internal shear resistance at the connection pursuant to the anchor shear design of ACI 318M-11 Appendix-D except for the equation to predict the concrete breakout failure strength at the concrete side, principally agreed with the experimental result based on the elastic analysis of Midas-Zen by using the largest loading from experiment.
        4,500원
        27.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aims at developing a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were performed on one unreinforced beam-column specimen and two reinforced specimens with U-type precast wall panels. Top shear connection of the PC panel was required to show the composite strength of RC column and PC wall panel. However, the strength of the connection did not influence directly on the ultimate loading capacities of the specimens in the positive loading because the loaded RC column push the side of PC wall panel and it moved horizontally before the shear connector receive the concentrated shear force in the positive loading process. Under the positive loading sequence(push loading), the reinforced concrete column and PC panel showed flexural strength which is larger than 97% of the composite section because of the rigid binding at the top of precast panel. Similar load-deformation relationship and ultimated horizontal load capacities were shown in the test of PR1-LA and PR1-LP specimens because they have same section dimension and detail at the flexural critical section. An average of 4.7 times increase in the positive maximum loading(average 967kN) and 2.7 times increase in the negative maximum loading(average 592.5kN) had resulted from the test of seismic resistant specimens with anchored and welded steel plate connections than that of unreinforced beam-column specimen. The maximum drift ratios were also shown between 1.0% and 1.4%.
        4,200원
        28.
        2015.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to establish and examine the analytical methods based on FEA to predict the behavior of the precast prestressed concrete panels under blast loading. The precast prestressed concrete structures are on the rise, but there is little research in this regard explosion. In this paper, we set the variable to the three models. TNT 500 kg was an explosion in the standoff-distance 3m. In conclusion, the precast models damage was concentrated in the bonded portion. The concrete panels after an explosion occurred continuously deformed. But the including prestressed panels deformation occurs only at the beginning of the explosion were able to see the results.
        4,000원
        30.
        2010.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        프리캐스트 콘크리트 골조에서 실물크기의 보-기둥 접합부 실험체 5개를 대상으로 반복가력 실험을 수행하였다. 지진하중을 받는 골조를 대상으로 1개의 일체식 실험체와 4개의 프리캐스트 실험체를 포함하여 5개의 1/2스케일의 내부 보-기둥 접합부를 대상으로 하였다.주요 변수는 보의 구조적 연속성을 확보하기 위한 접합부의 형태와 접합부의 특별한 보강형태(섬유콘크리트와 횡보강근)로 하였다. 실험체는 강기둥-약보 개념에 따라 설계하였다. 보 철근은 접합부에 큰 비탄성 전단력이 작용할 경우 보에 소성힌지가 발생하도록 계획하였다. 접합부의 성능평가는 접합부의 강도, 강성, 에너지 소산능력과 층간변위비로 평가하였다. 실험결과 실험체의 파괴는 보의 소성힌지부에서 파괴되었다. 보-기둥 접합부의 성능은 대체적으로 우수한 것으로 나타났다. 접합부의 강도는 일체식 RC 구조의 비해 1.15배 정도 향상되었다. 층간변위 3.5%때의 강도에서 실험체는 ECC의 인장변형능력과 철골연결재의 항복에 의해 연성거동 하였다.
        4,200원
        31.
        2010.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PC(Precast Concrete) 구조시스템은 건식화 조립식 공법으로 구조물 건설에 있어 공기, 노동력 절감 등의 여러 장점을 가지고 있다. 하지만 구조벽체의 경우 이를 PC화하여 사용할 경우 접합부의 내진성능이 떨어지므로 PC 구조벽체를 사용하는 경우는 드물다고 할 수 있다. 본 연구에서는 이러한 점을 감안하여 접합부 성능을 개선하여 횡력저항요소로 사용가능한 2종류의 PC 구조벽체를 제안하였다. 제안된 PC 구조벽체는 RC 벽체 및 PC 벽체가 혼합된 복합 PC 벽체와 벽체하부 연결철근의 일부를 단면감소시키고 비부착상세를 적용한 PC 벽체로서 지진발생 시 충분한 강도와 변형능력을 확보할 수 있도록 하였다. 제안된 PC 구조벽체의 내진성능평가를 위하여 RC 벽체를 포함한 3가지 벽체에 대한 실험체를 제작하여 주기 횡하중 실험을 수행하였다. 실험결과, 제안된 PC 구조벽체는 강도, 강성, 변형능력 및 에너지 소산능력이 기존 PC 구조벽체보다 월등히 향상되어 우수한 내진성능을 확보할 수 있는 것으로 나타났다.
        4,300원
        32.
        2009.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        프리캐스트 콘크리트 세그먼트 공법은 품질관리가 용이하고 비용 및 공사기간을 단축할 수 있으나 각 세그먼트의 조립으로 인한 접합부의 응력집중 및 큰 변위로 인해 구조적으로 불리한 거동을 보여 많은 장점에도 불구하고 폭넓은 적용에 있어 그 한계가 발생한다. 이에 본 연구에서는 구조 성능이 개선된 프리캐스트 세그먼트 접합부를 제안하고 실험을 통하여 균열 및 파괴양상, 변형률, 최대하중, 변위 연성도의 측면에서 제안한 접합부의 구조 성능을 평가하고자 하였다. 본 연구에서는 시공성 및 구조성능을 고려하여 전단키 및 포스트텐션, 강봉 등의 적용여부를 변수로 한 접합부를 제안하고 이에 대해 정적 재하 실험을 수행하였다. 실험 결과, 전단키 및 포스트텐션을 적용한 SGSP 실험체는 최대하중의 측면에서 일체형 실험체에 비해 약 86%에 준하는 내력을 보였으며 연성 측면에서는 일체형 실험체의 연성 능력 이상의 연성거동을 보임으로써 제안한 접합부의 개선된 구조성능 및 적용 가능성을 확인할 수 있었다.
        4,000원
        33.
        2009.09 구독 인증기관 무료, 개인회원 유료
        As architectures have recently become high-risers and mega-structured, stable high strength products have been ensured. Accordingly, use of precast concrete accouplement has been increased in order to facilitate air compression and rationalize construction. Since external rising by the steam heating and internal rising by the accumulation of cement hydration heat for the temperature of members, precast concrete members with large cross-section used for high-rise mega-structure's columns and beams may exhibit different temperature history compared to the precast concrete members for wall and sub-floor with relatively small cross-sections. Therefore, this study aims to elucidate the characteristics of temperature history of mass concrete members cast with high-strength concrete for precast concrete application. In this study, large cross-sectional precast concrete mock-up, unit cement quantity, and temperature histories in manufacturing precast concrete member under different curing condition were inclusively investigated.
        4,000원
        34.
        2009.09 구독 인증기관 무료, 개인회원 유료
        Recently, as architectural concrete structures become high-rise and megastructured, concrete become high-strengthened and, by ensuring products of more stability, and rationalization of construction are required.large cross-sectional precast concrete members such as columns show large temperature increase in manufacturing process not only by external heating but also by concrete itself's hydration heating. Therefore, it is expected that specimen for management to predict strength and compression strength of precast concrete member shows different strength characteristics. Conceming this, in order to suggest strength characteristics of high strength mass concrete suitable for precast concrete application, this study comprises the inclusive investigations on the relations between core strength and the strength characteristics per member cross-section dimensional value and per water-bonding material ratio value.
        4,000원
        35.
        2008.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        콘크리트 슬래브를 공장에서 제작하여 도로포장의 신설 또는 보수에 사용하는 공법인 프리캐스트 콘크리트 포장의 하중전달 성능을 평가하기 위하여 연구를 수행하였다. 실내실험을 통해 다웰바 연결 부분의 그라우팅 효과를 측정할 수 있는 방법을 고안하였으며 이러한 실험을 위해 실험체를 제작하여 실험하였다. 실험을 수행한 결과 그리우팅을 한 다웰바의 전단강도는 콘크리트와 일체식으로 된 다웰바의 전단강도에 비해 떨어지지 않음을 알 수 있었다. 이울러 현장에서의 시험시공을 통해 설치된 보수용 프리캐스트 콘크리트 포장에 대해서도 FWD 시험을 실시하여 하중전달 성능을 평가하였다. 현장 실험 결과 기존 콘크리트 포장에 비해 슬래브 중앙부에서의 처짐은 다소 크게 나타나나, 줄눈부에서의 하중전달율은 거의 유사한 것으로 나타났다.
        4,200원
        36.
        2008.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 프리캐스트 콘크리트 슬래브를 이용한 급속 신설 도로 포장 공법의 국내 적용성을 분석하기 위한 기초 연구를 수행하고 시험시공을 통해 선설 프리캐스트 포장의 설계 및 시공 지침을 개발하기 위하여 수행되었다. 시험시공을 위해 가로, 세로, 깊이가 각각 실제 포장 슬래브의 1/2 크기인 슬래브를 설계하여 제작하였으며 이에 적합한 철근배근, 종방향과 횡방향의 연결부, 그라우팅 방법 등에 대하여 분석을 수행하였다. 이러한 슬래브를 이용하여 종방향과 횡방향으로 두 개씩 총 4 개의 슬래브를 연결하여 평탄성을 조절한 후 포켓 부분과 슬래브 하부의 공간을 그라우팅 함으로써 시공을 신속 용이하게 수행하였다. 시험 시공을 수행하며 프리캐스트 포장의 설계 및 시공과 관련된 세부 사항을 면밀히 분석하였으며 이에 바탕을 두어 프리캐스트 슬래브를 이용하여 급속하게 신설 도로를 건설할 때의 설계 및 시공 지침을 개발하였다.
        4,200원
        38.
        2007.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        공장에서 제작한 콘크리트 슬래브를 나열한 후 프리스트레싱 기법을 도입하여 일체화시켜 건설하는 프리캐스트 프리스트레스트 콘크리트 포장의 강선 긴장에 의한 압축력 재하 시 포장체의 거동을 유한요소해석 모델을 개발하여 분석하였다. 먼저 정착구의 개수가 긴장 시 포장체의 압축응력 분포에 미치는 영향을 분석하여 적절한 정착구의 개수를 선정하였다. 그리고 하부층의 수평저항, 포장체의 길이, 슬래브의 두께, 정착단의 전단면적 등의 변수가 포장체의 압축응력 분포에 어떠한 영향을 미치는지에 대하여 분석하였다. 하부층의 수평저항은 압축응력의 손실을 가져오며 이러한 손실은 포장체의 중앙부로 갈수록 증가하게 된다. 또한 포장체의 길이가 길어질수록 하부층 수평저항에 의한 압축응력의 감소가 커지게 된다. 슬래브의 두께는 얇아질수록 하부층 수평저항에 의한 압축응력의 손실이 커지게 된다 하지만 압축력을 가하는 면적인 정착단의 전단면적은 압축응력의 분포에 크게 영향을 미치지는 않는다.
        4,000원
        39.
        2007.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 프리캐스트 콘크리트 포장 시공을 위하여 공장에서 미리 제작된 콘크리트 슬래브를 리프팅을 할 때 리프팅 위치에 따른 슬래브의 응력변화를 기준으로 슬래브의 손상을 최소화할 수 있는 가장 안전한 최적 리프팅 지점을 선정하기 위하여 수행되었다. 리프팅 시 슬래브의 응력분포를 분석하기 위하여 유한요소법을 이용한 모델을 사용하였으며 슬래브 규격은 시험시공에서 사용한 크기를 적용하였다. 리프팅은 항상 슬래브의 수직방향으로 수행하지는 않기 때문에 수직으로 리프팅 하였을 때와 60˚, 30˚로 경사각을 주어 리프팅 하였을 때의 응력변화 특성을 분석하였다. 또한 리프팅 지점은 항상 슬래브의 중간 깊이인 중립축의 위치가 아니기 때문에 중립축으로부터 7.5cm. 15cm만큼 수직편심을 주어 리프팅하였을 때의 응력변화 특성도 분석하였다. 그리고 실제 시공 시 지점부분에 보강을 하는 것을 염두하여 지점부 응력집중현상을 무시한 경우와 보강이 없을 경우의 응력집중현상을 고려한 경우로 나누어 분석하였다. 이러한 해석을 통해 리프팅 경사각과 편심에 따른 최적 리프팅 위치를 선정하였으며 미국의 PCI기준과도 비교 분석하였다.
        4,200원
        40.
        2006.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 철근콘크리트 프리캐스트 대형판의 접합부 설계방법 및 해석방법에 대해서 연구를 수행하였다. 접합부의 설계방법은 수평접합부와 수직접합부의 구조적 거동에 대한 안정성 및 일체성을 확보하기 위한 설계법을 제시하였고, 접합부의 해석은 강체스프링 모델에 의한 탄소성해석을 수행 하였다.
        4,000원