        61.
        2015.10 서비스 종료(열람 제한)
        In this study, We evaluated the applicability of high performance fiber reinforced cementitious composite (HPFRCC) with compressive strength of 180, 140 and 100 MPa and identical contents in steel fiber. The analysis of the flexure tensile behavior showed that HPRFCC presents deflection hardening after the initiation of cracks and exhibits higher energy absorbing capacity with high compressive strength.
        62.
        2015.10 서비스 종료(열람 제한)
        The purpose of this research is to evaluate the standard deviation and coefficient of variation for flexural strength of lathe scrap reinforced cementitious composites. For this purpose, the cementitious composites containing lathe scrap were repeatedly made 5 times for water-binder ratio of 30%, 2mm width and 40mm length of lathe scrap, and then the standard deviation and coefficient of variation of the cementitious composites were estimated. It was observed from the test results that the standard deviation and coefficient of variation of the cementitious composites were slightly larger than plain mortar but did not matter much.
        63.
        2015.04 서비스 종료(열람 제한)
        Ultra high strength concrete was introduced into architectural members. The current ultra high strength concrete can achieve compressive strengths up to 200 MPa and tensile strengths up to 20 MPa. In this study, the flexural and shear strengths in precast structural beams using ultra high strength concrete are evaluated and compared with reinforced concrete beams. This paper also provide a design flexural strength formula for the developed members.
        64.
        2015.04 서비스 종료(열람 제한)
        This study investigated the flexural performance of high performance fiber reinforced cementitious composite (HPFRCC), which used high strength steel fibers with volume fraction 8%. Under the third-point loading using a closed-loop, servo-controlled testing system (ASTM 1609), load-deflection curves were obtained. The major test variables include silica fume replacement ratio 15% and exposure termperature, ambient and 400°C. The flexural strength was similar to the compressive strength and the absorbed fracture energy was relatively greater than other typical HPFRCC materials. This may be a composite reaction of the strong bonding between steel fiber and matrix and high compressive strength of the matrix itself. Once the specimens were exposed to high temperature 400°C the flexural strength decreased.
        65.
        2015.04 서비스 종료(열람 제한)
        In this study, A preliminary research has been attempted by design and strength analysis on a series of precast ultra high-strength concrete slab systems in order to evaluate. To compare with conventional reinforced concrete slabs, current slab systems can improve serviceability and ultimate load capacities, crack control, and durability, so as to apply in long span, lightweight, and slender building slab systems.
        66.
        2014.10 서비스 종료(열람 제한)
        The purpose of this experimental study is to evaluate that KCI2012 equation for the development length, ldt, of headed bars can be used to calculate the lap length of headed deformed bars in grade SD400~500 for high strength concrete. Test results showed that specimens with lap lengths equal to 1.3ldt had maximum flexural strengths as 0.84~0.90 times as the nominal flexural strengths. These observations indicate that 1.3 is unsuitable to the tensile lap length of headed deformed bars in grade SD400~500 for high strength concrete.
        67.
        2014.04 서비스 종료(열람 제한)
        The purpose of this study is to evaluate the flexural strength of the concrete-infilled composite PHC (hereinafter ICP) pile which is the PHC pile reinforced with infilled concrete, transverse and longitudinal reinforcement for the improvement of flexural strength. In addition, an analytical study, which evaluated the flexural strength of the ICP piles depending on the reinforcement using the fiber section analysis was performed.
        68.
        2014.04 서비스 종료(열람 제한)
        In this study, the experiments were carried out in order that flexural behavior evaluated High-strength Concrete Beams reinfrced with FRP plates according ro replacement ration of recycled aggregate. As a result, maximum load was higher than existiong of unreinforced when the reinforced with FRP plates and no decrease in load about increased fo replacement ration of recycled aggregate. Some specimens was greater than ACI 440-2R referemce value.
        69.
        2014.04 서비스 종료(열람 제한)
        This paper described the correlation between compressive and flexural toughness of SFRC(Steel fiber reinforced concrete). Experiment was conducted to evaluate the correlation SFRC specimens with different aggregate sizes (8mm, 13mm, 20mm) and fiber volume fraction (0%, 0.5%, 1.0%, 1.5%, 2.0%). For the measurement of compressive and flexural toughness using ACI committee and ASTM C 1018 procedure. Test results indicated that the addition of steel fiber improves flexural and compressive performance of high-strength concrete. Also smaller aggregate size improve the mechanical properties of high fiber volume fraction SFRC.
        70.
        2014.01 KCI 등재 서비스 종료(열람 제한)
        본 연구는 순환굵은골재 콘크리트의 활용성 증대 및 규준 정립에 관한 연구의 일환으로 순환굵은골재 치환율에 따른 고강도 철근콘크리트 보의 휨 특성을 검토하고자 한다. 실험은 콘크리트 설계강도 40MPa, 50MPa, 60MPa 순환굵은골재 치환율 0%, 30%, 50%, 100%를변수로 총 12개의 실험체를 제작하여 최종 파괴 시까지 변위제어 방식에 의해 2점 가력하였다. 실험결과 천연골재를 사용한 실험체와 비교시 균열발생 및 파괴양상의 경우, 순환굵은골재를 사용한 철근콘크리트 보의 실험체는 천연골재 철근콘크리트 보 실험체에 비해 균열이 비교적 압축측까지 진전하는 특성을 보였으나 전반적으로 균열양상은 유사하게 나타났으며, KCI 설계기준식에 의한 계산값 및 실험결과의 비교결과 순환굵은골재 치환율에 관계없이 1.08~1.29로 기준값을 상회하는 것으로 나타나 순환굵은골재를 사용한 콘크리트 보의 휨 부재설계에 적용 가능할 것으로 판단된다. 따라서 순환굵은골재 활용성 증대를 위해 추가적인 실험을 통하여 순환굵은골재의 구조적 기준정립이 필요할 것으로 판단된다.
        71.
        2013.10 서비스 종료(열람 제한)
        In this study, the amount of construction waste created from Demolition and reconstruction of old buildings by environmental contamination by construction waste has been raised as a social problem, according as a means to settle problems the government is being encouraged the use Recycled aggregate. However recycled aggregate has not yet been applied to structures in many cases. Due to uncertain technical verification of long-term durability, the use of recycled aggregate is being limited. Accordingly in this study, High Strength Concrete Beams use Recycled coarse Aggregate to evaluate the performance of the bending and establish national standards for structural design of recycled aggregates aims to provide the basic data.
        72.
        2013.09 KCI 등재 서비스 종료(열람 제한)
        Eight small scale circular reinforced concrete columns were tested under cyclic lateral load with constant axial load. Test specimens were designed with 4.5 aspect ratio. The selected test variables are longitudinal steel ratio, transverse steel ratio, yielding strength of longitudinal steel and axial load ratio. The test results of columns with different longitudinal steel ratio, transverse steel ratio and axial load ratio showed different seismic performance such as equivalent damping ratio, residual displacement and effective stiffness. It was found that the column with low strength of longitudinal steel showed significantly reduced seismic performance, especially for equivalent damping ratio and residual displacement. The regulation of flexural over-strength is adopted by Korea Bridge Design Specifications (Limited state design, 2012). The test results are compared with nominal strength, result of nonlinear moment-curvature analysis and the design specifications such as AASHTO LRFD and Korea Bridge Design Specifications (Limited state design).
        73.
        2013.07 KCI 등재 서비스 종료(열람 제한)
        Prestressed concrete (PSC) members are readly available in civil engineering applications due to the convenience of construction and easy of quality control in the manufacturing process of the member. Especially, half-depth precast concrete composite slab, which is one of the PSC flexural members is developed recently using the long-line method. The half-depth precast concrete composite slabs are composed of the precast concrete and the in-situ concrete placed at the site. In this paper, we present the results of experimental investigations pertaining to the pretensioning efficiency and the flexural behavior of half-depth precast concrete composite slab which is made of precast PSC manufactured by the long-line method. In the long-line method, the pretensioned precast member is manufactured simultaneously, by tensioning tendons at once. In addition, we suggest the equation that can estimate the flexural strength of half-depth precast concrete composite slab reasonably by considering the effects of rebar embedded in the precast PSC flexural member.
        74.
        2013.04 서비스 종료(열람 제한)
        This paper describes the flexural performance of concrete and strain-hardening cement based composite (SHCC) beams reinforced with normal and high-strength steel bar to evaluate the effect of reinforcing bar strength and cement composite type. The present investigation shows the potential of high-strength structure materials used of high-strength reinforcing bars with SHCC. And superior mitigation of crack-damage is observed reinforced SHCC beams than reinforced concrete beams
        75.
        2013.04 서비스 종료(열람 제한)
        This experimental study was performed to investigate the effect of the aspect ratios and volume contents of hooked steel fiber for flexural tensile strength of SFRC with compressive strength of 60MPa. The notched steel fiber reinforced concrete beams with different aspect ratios and fiber volume content were tested under 3-point bending. and the flexural tensile strength, and CMOD were obtained from the experimental data. The result showed that the strength and ductility of SFRC were generally increse as the content of steel fiber was incresed.
        76.
        2012.02 서비스 종료(열람 제한)
        2010년 아이슬란드 남부의 화산폭발은 유럽지역에 항공대란을 야기하였으며, 국내에서도 2002년 백두산 지역을 중심으로 강진에 의한 지표면 팽창현상이 관찰되면서 백두산의 화산폭발 위험성이 점증하고 있다. 화산폭발이 발생하는 경우, 화산재의 처리 및 처분에 따른 막대한 국가적 손실이 유발되므로, 화산재 처리 및 활용방안의 개발이 절실히 요구되고 있는 실정이다. 본 연구에서는 화산재를 건설재료로 활용하기 위하여 백두산, 한라산의 화산재 및 다공성의 제올라이트에 시멘트 및 메타카올린을 첨가한 블럭에 대한 재령 0일 및 7일의 배합비별 휨강도 특성을 분석하였다. 실험 결과, 재령 7일에 대하여 혼합재(화산재 및 제오라이트), 시멘트 및 메타카올린의 비율을 3.5:1:0.1로 배합한 경우 최대의 휨강도를 나타내었으며, 재령 및 단위시멘트량의 증가, 메타카올린의 첨가가 휨강도 특성에 큰 영향을 미치는 것으로 나타났다.
        77.
        2012.02 서비스 종료(열람 제한)
        항복강도 690MPa 이상의 초고강도 고성능강재 HSB800 후판이 최근 국내에서 개발되었으나, 플레이트 거더 등 주요 구조물에 최적 활용되기 위한 설계기술 기반은 아직 마련되지 못하고 있는 실정이다. 고강도 강재는 일반적인 강재에 비해 비교적 낮은 연신율과 큰 항복비를 갖고 있어 구조연성 성능에 대해 다소 불리한 것으로 예상되며, 현행 AASHTO LRFD 설계기준의 비탄성 설계과정에서도 공칭항복응력 485MPa를 초과하는 단면 설계에 대한 적용이 엄격히 제한되어 있다. 본 연구에서는 HSB800시편에서 표준시험을 통해 획득한 비탄성 응력-변형율 특성을 고려한 3차원 비선형 유한요소 해석 방안을 정립해 보고자 한다. 관련 규준의 표준화 연구를 위해 재료특성의 표준모형 정립이 선행되어야 한다. 기존 일반강에 적용하던 완전탄소성 거동 및 다중 선형 재료특성 곡선과 실제 재료특성을 적용한 비탄성 연성거동 해석결과에 대해 상호 비교연구를 수행하였다. 향후 실 구조물 규모의 실험적 검증을 통해 본 해석적 모형이 검증된다면, HSB800을 적용한 플레이트 거더의 비탄성 설계에 관한 광범위한 연구를 효과적으로 수행할 수 있을 것으로 판단된다.
        78.
        2011.11 KCI 등재 서비스 종료(열람 제한)
        초고성능콘크리트(Ultra High Performance Concrete, UHPC)는 높은 강도와 내구성을 가지는 우수한 구조재료이다. 이러한 새로운 재료의 활용 기술은 경량의 슬림한 구조로서 우수한 성능을 가지는 구조물의 건설을 실현할 수 있는 효과적인 방안으로 주목받고 있다. 이 연구는 하이브리드 사장교 적용을 위한 UHPC프리캐스트 바닥판 시스템 개발의 일부로서 정모멘트 구간에서 철근겹침이음 방식에 의하여 연결되는 이음부의 거동 특성을 실험적으로 규명하는데 주된 목적이 있다. 주요 실험변수는 철근겹침이음길이이며 실험변수의 영향을 검증하기 위하여 총 12개의 휨실험체를 제작하였고, 이에 대한 4점 휨재하실험을 수행하였다. 현행 도로교설계기준에서 철근겹침이음에 대한 최소길이 규정은 UHPC를 적용한 프리캐스트 바닥판 시스템에서는 매우 보수적인 규정임을 실험결과로부터 확인할 수 있었다.
        79.
        2011.09 KCI 등재 서비스 종료(열람 제한)
        본 논문은 중간부 부착파괴된 CFRP 보강 RC 보의 휨강도 산정을 다루고 있다. CFRP 보강 RC 보의 중간부 부착파괴의 영향을 고려하기 위해 강도감소계수를 제안하였다. 제안된 계수는 CFRP의 유효응력(또는 유효변형률)과 극한응력(또는 극한변형률) 비로 정의 되는 유효변률 모델을 이용하여 실험데이터로부터 유도하였다. 휨강도 산정식은 강도감소계수를 변수로 하여 함수를 구성하였다. 제안된 강도감소계수의 유효성, 정확성 및 타당성을 입증하기 위해서 각국의 설계기준 및 연구자들에 의해 제안된 계수 값과 실험값을 본 연구결과와 비교 및 검증했다. 본 논문에서 제시하는 해석 결과는 제안된 강도감소계수가 중간부 부착파괴된 CFRP 보강 RC 보의 휨강도를 매우 효율적으로 평가할 수 있음을 나타낸다.
        80.
        2011.05 KCI 등재 서비스 종료(열람 제한)
        파형강판을 이용한 구조물은 기존의 철근콘크리트 구조물에 비하여 공기단축효과 및 경제성 등이 우수하고 유지관리비의 절감 측면에서 유리한 것으로 평가되고 있다. 최근 수로암거 및 생태 이동 통로등에 철근콘크리트 암거 대체 재료로 널리 활용되고 있으며 앞으로 적용실적이 더 증가할 것으로 예상된다. 파형강판을 사용한 구조물은 주로 아치형과 박스형의 두가지 형태이며, 아치형 구조물은 압축력에 의하여 설계하며 박스형 구조물은 플레이트 부재내의 모멘트에 의하여 설계한다. 따라서 본 연구에서는 기존의 대골형 파형강판보다 골의 피치와 깊이가 늘어난 성능 개선된 파형강판의 성능을 평가고하고 설계에 반영하기 위해 정적 압축 시험 및 휨시험을 수행하여 시험체 두께별 이음부의 극한강도 및 모멘트 강도를 검토 하였다.