검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 11

        1.
        2023.11 구독 인증기관·개인회원 무료
        In the dismantling of nuclear power plants, various forms of radioactive gaseous waste are generated when cutting concrete and metal structures. Large amounts of radioactive dust and aerosols generated during the cutting process of each structure can cause radiation exposure to the environment around the workplace and to the radiation exposure in the body of workers. When cutting structures, water is sprayed to reduce the generation of aerosols, so early saturation of the filter is expected due to radioactive aerosols and fine particles containing a large amount of moisture. A mobile air purification device is being developed to a fast and efficient air purifier that can be used for a long time operation to protect workers from radiation exposure in high radiation areas and to minimize the amount of secondary waste generated. In this paper, the direction for a new concept of unit technology that can achieve the development purpose is described.
        2.
        2022.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Seoul has installed mechanical air filters in the heating, ventilation, and air conditioning (HVAC) systems of city buses to improve their indoor air quality since late 2019. We evaluated particle removal efficiencies of the filter in a wind tunnel, and clean air delivery rates (CADRs) of the systems and a household air purifier in the buses, following the test standards. The filter showed the efficiencies of 91% and 97.6%, 88% and 97.9%, and 78% and 95.2% for 0.35 μm particles and PM2.5 at 1.0m/s, 1.5m/s, and 2.0m/s, respectively. The efficiencies rose with an increase in the particle size and the filters had a minimum efficiency reporting value (MERV) rating of 15. The CADRs for PM2.5 and flow rate of the systems were 12.7m3/min and 17.9m3/min, 16.6m3/min and 25.4m3/min, 18.7m3/min and 33.6m3/min, and 23.3m3/min and 47.1m3/min on the operation mode of 1, 2, 3, and 4, respectively. The CADRs of the systems were 3.8-7.1 times higher than those of the air purifier, but single-pass removal efficiencies of the former were 0.56-0.81 lower than those of the latter.
        4,000원
        5.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, we conducted a survey to reveal the general perception of parents toward outdoor air quality, particulate matter (PM), and indoor air quality (IAQ) at schools where their children attend. A total of 1,030 parents participated in this survey, where the age of their children ranged between 7 years to over 19 years of age. Each participant was either a member of a non-governmental organization (NGO) with a keen interest in air quality or an ordinary public panel member with less interest. The result of the survey indicated that the participants had a negative perception of air quality, and parents believed that the outdoor and indoor air is extremely polluted. The participants pointed out that they believe that the main reason for the pollution is due to particulate matter (PM) and school classrooms are the location where their children are exposed to PM the most. Based on our study, the majority of the participants prefer a mechanical ventilation system to reduce indoor air pollutants in schools. Our study should be referred to by school officials in order to maintain IAQ and as a way of addressing the concerns of parents who want to protect their children’s health.
        4,000원
        6.
        2009.09 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to assess the removal efficiency of formaldehyde using carbon nano colloid (CNC) which was produced by comparatively easy and cheap method. In this study, carbon nano colloid based on water was produced by an electro‐chemical method. The particles which have mostly a spherical shape whose diameter was, what is called,‘nano‐size’were produced. Non‐woven fabric filter, which is currently on the market as a medium filter, was used for the removal efficiency test. Known concentration (0.5 ppm) of formaldehyde standard gas was used as a pollutant. The overall results indicate that (1) nanosize carbon colloids which have a stable dispersibility of which diameter is approximately 10 nm or less, (2) filters treated with carbon nano colloids showed higher removal efficiency, 44.47 ㎍ of HCHO removed/g of carbon and 19.28 ㎍ of HCHO removed/g of carbon, compared to the control experiment using a normal carbon filter, 1.45 ㎍ of HCHO removed/g of carbon.
        4,000원
        7.
        2020.06 KCI 등재 서비스 종료(열람 제한)
        This study analyzes the effect of negative air ions on the concentration of airborne particulate matter and evaluates the expected purification efficiency of open spaces for particulate matter by investigating the amount of negative air ions generated by plants. This study establishes a negative air ion generation treatment environment, plant environment, and control environment to measure the purification efficiency of particulate matter under the conditions of each, analyzing the expected purification efficiency by designing a particulate matter purification model. Results show that the amount of generated negative air ion according to environment was negative air ion generation treatment environment > plant environment > control environment; this order also applies to the particulate matter purification efficiency. Moreover, it took 65 min for the negative ion generation treatment environment, 90 min for the plant environment, and 240 min for the control environment to reach the standard expected purification efficiency of particulate matter concentration of 960 mg/m³ for PM10. For PM2.5, with the designated maximum concentration of 700 mg/m³, it took 60 min for the negative ion generation treatment environment, 80 min for the plant environment, and more than 240 min for the control environment. Based on these results, the expected purification efficiency compared to the control environment was quadrupled in the negative ion generation treatment environment and tripled in the plant environment on average.
        8.
        2015.10 KCI 등재 서비스 종료(열람 제한)
        The final goal of this research is to develop a botanical biofiltration system, which combines green interior, biofiltering, and automatic irrigation, which can purify indoor air pollutants according to indoor space and the size of biofilter. The biofilter used in this experiment was designed as an integral form of water metering pump, water tank, blower, humidifier, and multi-level planting space in order to be more suitable for indoor space utilization. This study was performed to compare indoor air quality between the space adjacent to a botanical biofilter and the space away from the biofilter (control) without generation of artificial indoor air pollutants, and to evaluate plant growth depending on multiple floors within the biofilter. Each concentration of indoor air pollutants such as TVOCs, monoxide, and dioxide in the space treated with the biofilter was lower than that of control. Dracaena sanderiana ‘Vitoria’ and Epipremnum aureum ‘N Joy’ also showed normal growth responses regardless of multiple floors within the biofilter. Hence, it was confirmed that the wall-typed botanical biofilter suitable for indoor plants was effective for indoor air purification.
        9.
        2013.12 KCI 등재 서비스 종료(열람 제한)
        Biogas from anaerobic digestion of biological wastes is a renewable energy resource. It has been utilized to provideheat and electricity. Raw biogas contains about 55~65% methane, 30~45% carbon dioxide, 0.5% of hydrogen sulfidegas and fraction of water vapor. The presence of CO2 and H2S in biogas affects less caloric value of raw biogas andcorrosion of engine etc.. Reducing CO2 and H2S contents improves a quality of fuel. In this paper, the absorption processusing aqueous monoethanol amine has been investigated as one of the leading technologies to purify the biogas. Liquidabsorbent is circulated through the reactor, contacting the biogas in countercurrent flow. The experimental results of themethane purification in simulated biogas mixture consisted of methane, carbon dioxide and hydrogen sulfide werepresented. It was shown that using aqueous solution used is effective in reacting with CO2 in biogas and it was possibleto achieve the purification of methane from the concentration of 55% up to 98%. This technique proved to be efficientin enriching and purifying of biogas, and has to be used to improve process efficiency.
        10.
        2012.11 KCI 등재 서비스 종료(열람 제한)
        To date, carbon and nitrogen co-doped photocatalysts (CN-TiO2) for environmental application focused mainly on the aqueous phase to investigate the decomposition of water pollutants. Accordingly, the present study explored the photocatalytic performance of CN-TiO2 photocatalysts for the purification of indoor-level gas-phase aromatic species under different operational conditions. The characteristics of prepared photocatalysts were investigated using X-ray diffraction, scanning emission microscope, diffuse reflectance UV-VIS-NIR analysis, and Fourier transform infrared (FTIR) analysis. In most cases, the decomposition efficiency for the target compounds exhibited a decreasing trend as input concentration (IC) increased. Specifically, the average decomposition efficiencies for benzene, toluene, ethyl benzene, and xylene (BTEX) over a 3-h process decreased from 29% to close to zero, 80 to 5%, 95 to 19%, and 99 to 32%, respectively, as the IC increased from 0.1 to 2.0 ppm. The decomposition efficiencies obtained from the CN-TiO2 photocatalytic system were higher than those of the TiO2 system. As relative humidity (RH) increased from 20 to 95%, the decomposition efficiencies for BTEX decreased from 39 to 5%, 97 to 59%, 100 to 87%, and 100 to 92%, respectively. In addition, as the stream flow rates (SFRs) decreased from 3.0 to 1.0 L min-1, the average efficiencies for BTEX increased from 0 to 58%, 63 to 100%, 69 to 100%, and 68 to 100%, respectively. Taken together, these findings suggest that three (IC, RH, and SFR) should be considered for better BTEX decomposition efficiencies when applying CN-TiO2 photocatalytic technology to purification of indoor air BTEX.