검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 24

        1.
        2023.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The importance of urban green space creation is increasingly recognized as the most realistic and efficient approach for fine dust mitigation in urban areas. Particularly considering the characteristics of domestic cities, the application of buffer green spaces along roads can maximize the efficiency of fine dust reduction without the need for separate green space creation. Accordingly, this study analyzed the fine dust mitigation effects based on the types of plantings in the central dividers and roadside trees in Jeonju City, Jeollabuk-do. To do this, we controlled various external variables of urban space and considered the planting arrangement types in the central dividers, carrying out the analysis using a CFD simulation. The simulation results confirmed that the central dividers with plantings demonstrated more effective ultrafine dust reduction than those without. Moreover, the arrangement of roadside trees showed a greater ultrafine dust reduction effect when adopting a multilayered structure compared to a single layer. Based on these findings, we concluded that installing both trees and shrubs simultaneously in the central dividers and along roads was effective for ultrafine dust mitigation. On this basis, we quantified the dust reduction effects of plants in urban street environments and proposed planting guidelines for roadside green spaces to improve air quality.
        4,000원
        2.
        2023.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        수많은 함정용 채프들은 폭발에 의해 확산되어 채프운을 형성하며, 채프운은 허위 레이더 반사 단면적을 생성하여 적의 레이더를 기만한다. 본 논문에서는 전산유체역학-이산요소법 단방향 연동 기법을 기반으로 공기 중에 분포하는 함정용 채프운의 시공간 분포 를 해석하는 수치적 프레임워크를 구축하고 바람의 방향과 속도, 채프 카트리지의 초기 각도와 폭발 압력이 채프운 분포에 미치는 영 향을 분석하였다. 채프운의 확산은 폭발에 의한 방사형 확산, 난류와 충돌에 의한 전 방향 확산, 낙하 속도 차이에 의한 중력 방향 확산 과 같이 세 단계로 구분되는 것을 확인하였다. 바람은 채프운의 평균 위치를 이동시켰으며, 항력에 의한 확산 효과는 나타나지 않았다. 카트리지 초기 각도에 따라 폭발에 의한 방사형 확산 방향이 달라졌으며, 각도가 지면과 수직에 가까울수록 더 넓게 확산되었다. 폭발 압력이 증가할수록 채프운은 더 넓게 확산되었으나 중력 방향으로는 분포 차이가 작았다.
        4,200원
        3.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        도로협곡에서의 수목식재에 따른 보도 내 교통유발 대기오염도 변화를 살펴보기 위해 오픈소스 전산유체역학 코드 FDS(Fire Dynamics Simulator)를 사용하여 수목 투과지수, 식재 위치 및 유형에 따른 영향을 조사하였다. 광범위한 시뮬레이션을 통해 1) 관목층 만으로만 구성된 사례, 2) 관목층과 아교목층으로 구성된 사례 및 3) 관목층과 교목층으로 구성된 사례를 포함하는 400개의 시나리오 사례 중 399개 사례에 대해 유효한 데이터를 생성하였다. 분석결과, 보도 위에서 관찰되는 평균화된 정상상태 대기오염 농도는 식재유 형과는 무관하게 수목식재 후 약 10% 이상 감소하는 것으로 나타났다. 가장 큰 대기오염 감소효과는 관목층만으로 구성된 사례에서 관찰되었는데 대략 45%까지 감소하는 것으로 나타났다. 이러한 감소효과는 차선에서 인도로 대기오염물질을 직접 수송하는 선회류가 관목층에 의해 유리한 방향으로 변형되는 물리적 과정에 기초한다.
        4,000원
        4.
        2021.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 Froude 수 1.0, 길이 약 10 m 급 소형 고속선의 저항성능과 승선감을 향상시키기 위해 선미 끝단에 트림 탭을 부착하여 항주자세를 제어하였고, 트림 탭의 제원에 따른 성능을 확인하기 위해 CFD 해석을 수행하였다. 먼저 선행 연구로부터 수치 해석이 수행되는 스케일에 따라 결과에 차이가 있는 것이 확인되었고, 이를 피하고자 실선 스케일에서의 해석을 수행하였다. 부착된 트림 탭의 코드 길이는 LPP의 0.5, 1.0, 1.5 %였으며, 선저 면과의 각도는 5 간격으로 변화를 주었다. 트림 탭은 선박의 선미트림과 부상량을 감소시키는 효과가 있었으며, 이 효과는 트림 탭의 선저 면과의 각도가 클수록, 코드 길이가 길수록 증가하였다. 이로 인해 압력 저항은 감소하고 전단저항은 증가하였으며, 두 성분의 변화량에 따라 전 저항 저감율이 결정되었다. 결과로부터 대상 선박의 최적 항 주자세는 약 1.5 의 선미트림으로 특정되었고, 이때 저항성능은 약 27 % 개선되었다.
        4,000원
        6.
        2021.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, the effect of the turbulence intensity in across-wind direction on the wind load in CFD(Computational fluid dynamics) simulation was analyzed. ‘Ansys fluent’ software was used for CFD simulation. And the fluctuating wind speed applied to the simulation was generated according to Korean Design Standard and Von Karman wind turbulence model. The turbulence intensity in across-wind direction for simulation was applied from 0 to 100% of the turbulence intensity in along-wind direction. The analysis results showed that the turbulence intensity in across-wind direction had a particularly great effect on the wind load in across-wind direction.
        4,000원
        7.
        2020.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The objectives of this study were to develop the optimal structures of recirculating aquaculture tank for improving the removal efficiency of solid materials and maintaining water quality conditions. Flow analysis was performed using the CFD (computational fluid dynamics) method to understand the hydrodynamic characteristics of the circular tank according to the angle of inclination in the tank bottom (0°, 1.5° and 3°), circulating water inflow method (underwater, horizontal nozzle, vertical nozzle and combination nozzle) and the number of inlets. As the angle in tank bottom increased, the vortex inside the tank decreased, resulting in a constant flow. In the case of the vertical nozzle type, the eddy flow in the tank was greatly improved. The vertical nozzle type showed excellent flow such as constant flow velocity distribution and uniform streamline. The combination nozzle type also showed an internal spiral flow, but the vortex reduction effect was less than the vertical nozzle type. As the number of inlets in the tank increased, problems such as speed reduction were compensated, resulting in uniform fluid flow.
        4,300원
        9.
        2017.10 구독 인증기관·개인회원 무료
        현장에서 양생 또는 고형화 과정을 거치는 일반 시멘트 콘크리트, 자가다짐 시멘트 콘크리트, 아스팔트 콘크리트, 고분자 개질 혼합물과 같은 도로포장 재료의 유동 특성은 시공시점에서의 환경조건과 함께 도로포장 구조물의 초기 성능을 결정하는 중요한 요소이다. 따라서 재료의 양생이 완료되는 시점까지 포설 및 다짐에 영향을 미치는 재료의 유동 특성을 검토하는 것은 기존 혼합 및 포설 장비의 개선뿐만 아니라 새로운 장비의 개발을 통한 시공과정 개선 및 최적화를 위해서도 매우 중요한 과정이라 할 수 있다. 또한 건축 또는 토목 구조물의 시공 및 유지관리에 활용되는 건설정보 모델링이 향후 부재의 역학적 거동과 연계된 시공 및 유지관리를 포함하는 통합적인 수준으로 발전될 것임을 고려할 때, 경험에서 벗어나 실험적으로 검증된 역학적 기반의 설계 및 시공 방법을 제시하는 것은 매우 중요한 의미를 갖는다. 건설재료의 유동은 그 최종 형태에 따라 순수전단 유동, 신장유동, 이들의 중간 정도에 해당하는 유동의 3가지로 구분하여 분석적 해를 유도할 수 있다. 그러나 분석적 해를 활용하는 방법은 비교적 단순한 경계조건에 대한 재료의 유동적 특성을 예측하는데 유용하게 활용될 수는 있으나, 경계조건이 복잡해질수록 해를 계산하는 것이 거의 불가능하여 컴퓨터를 활용한 수치해석 기법을 적용하는 것이 합리적이다. 한편 유동성 재료의 동적 거동을 해석하는 방법으로는 이산요소법이나 전산유체역학(computational fluid dynamics, CFD)을 활용할 수 있는데, 입자형 재료 사이에 존재하는 유체의 양이 상대적으로 적어 입자와 입자 사이 또는 입자와 경계조건과의 상호작용이 중요하게 고려되어야 할 경우에는 이산요소법이 바람직한 반면, 시멘트 페이스트와 같이 균질의 재료로서 연속체의 특성을 나타내는 경우에는 CFD를 활용하는 것이 바람직한 것으로 알려져 있다. 본 연구에서는 연속체로 가정할 수 있는 유동성 재료의 시간에 따른 거동을 예측하기 위한 CFD의 활용성을 평가하고자 하였다. 이를 위하여 미니콘 실험에 대하여 분석적 해와 CFD를 활용한 결과를 비교하여 수치해석에 활용된 가정과 모형의 타당성을 검증하였으며, 검증된 모형을 활용하여 주요 입력변수에 대한 민감도 분석을 수행하여 시간에 따른 재료의 슬럼프와 퍼진 정도의 변화를 확인하였다.
        10.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The objective of this study was to investigate design factors of the electrolysis reactor through the CFD(computational fluid dynamics) simulation technique. Analyses of velocity vector, streamline, chloride ion concentration distribution showed differences in flow characteristics between the plate type electrode and the porous plate type electrode. In case of the porous plate type electrode, chlorine gas bubbles generated from the anode made upward density flow with relatively constant velocity vectors. Electrolysis effect was more expected with the porous plate type electrode from the distribution of chloride ion concentration. The upper part of the electrolysis reactor with the porous plate type electrode had comparatively low chloride concentration because chloride was converted to the chlorine gas formation. Decreasing the size and increasing total area of rectifying holes in the upper part of cathodes, and widening the area of the rectifying holes in the lower part of cathodes could improve the circulation flow and the efficiency of electrolysis reactor.
        4,000원
        11.
        2015.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        풍력발전 타워는 높은 세장비를 갖는 형상으로 인해 바람에 의해 발생하는 횡하중에 취약한 구조를 가지고 있기 때문에 바람은 풍력발전 타워를 설계하는데 있어서 중요한 설계요소 중 하나라고 할 수 있다. 본 논문에서는 타워 운송 편의성 향상을 위해 설계된 8각 및 6각 단면형상을 가지는 조립식 강관 타워 및 일반 원형 강관 타워의 일정 높이 이상에서부터 4개의 작은 기둥으로 분리되는 형상을 가지는 멀티기둥 강관 타워에 대한 2차원 단면모형 풍동실험과 3차원 모형 풍동실험을 수행하여 각 형상별 풍력계수를 산정하여 그 특성을 비교하였다. 또한 풍동실험 축소모형에 대한 CFD 해석을 수행하여 산정된 풍력계수값의 신뢰성을 확인하였으며, 마지막으로 실제스케일 풍력타워에 대한 CFD 해석을 수행하여 각 형상별 특성을 분석하였다.
        4,000원
        12.
        2015.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        세계적으로 급증하는 전력수요에대처하고, CO2 배출을 줄이고자 인구가 밀집되어 있는 도 심지에 복합화력 발전소가 건설되고 있다. 환경규제가 계속적으로 강화됨에 따라 NOx 배출량을 줄이고 자 저 NOx 버너, SCR 등 여러 가지 설비들을 설치하고 있다. 본 연구는 경기도 고양시 소재의 일산열병합발전소 1개소에서 배출되는 질소산화물을 TMS를 이용하 여 배출계수를 산정하여 이를 전산유체동역학(CFD)에 적용하여 질소산화물의 거동을 살펴보고, 현장 실 측 결과와 비교 검토하였다. 실측 기간 중 측정 시간에 따른 주 풍향․풍속의 순간적인 변화로 인해 실측 결과와 CFD 모델링 결과 의 차이가 나타날 수 있으나, 모델링 결과와 실측 결과는 대부분 예측지점에서 유사한 농도로 나타났다. 향후 주변농도를 고려한 기여농도를 산출하여 실측농도에 가까운 예측농도 도출이 가능 할 것으로 판단 된다.
        4,000원
        13.
        2014.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper presents a Computational Fluid Dynamics(CFD) based simulation and experimental tracer test of flow pattern and turbulent energy dissipation inside a serpentine flocculation basin with continuous operation. Research focused on the evaluation of a specific flow pattern on the hydraulic behavior on the flocculation basin. From the results of CFD simulation and actual tracer test, both results were in good accordance with each other. Also, each Morill index were calculated as 1.5 from CFD simulation and 1.7 from actual tracer test, respectively. Especially, turbulence energy was dissipated relatively higher in the vicinity of inlet to the flocculation basin than other region. The differences between the CFD simulation and actual tracer test were 1.4 min in T50, and 1.3 min in Tp, respectively.
        4,000원
        14.
        2014.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In order to suggest the methodology for improving the equity of flow distribution in open channel with multiple outlet, CFD simulations were carried out for actual scale distribution channel being operated in domestic G_WTP(Water Treatment Plant). Also, before and after installing the longitudinal multi hole(diameter=250 mm, 116 holes) baffle suggested by this research, turbidity measurements data were collected for evaluating the effects of hydraulic modification for inlet flow equity. From the both results, total turbidity of settled water was lowered by 30 % and equity of flow distribution was improved about 60 % compared with before hydraulic structure modification.
        4,000원
        15.
        2014.04 구독 인증기관·개인회원 무료
        In this study, a circular tower, a modular tower and a multi-column tower were subjected to wind tunnel test and CFD (Computational Fluid Dynamic) simulation. A modular tower with an octagonal cross-section is designed for easy transportation during construction. A multi-column tower with four secondary columns, which have smaller cross-sectional area relative to the main column, is designed for mitigating wind load. Their mean wind force coefficients were obtained through wind tunnel test and CFD simulation, which were carried out by Daewoo Institute of Construction Technology. Their results are compared to each other to verify the reliability of calculated mean wind force coefficient. Difference between mean wind force coefficient values obtained from wind tunnel test and CFD simulation is shown to be within 10% for a circular tower and a multi-column tower, and slightly above 10% for a modular tower.
        16.
        2013.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        소각로 내 공기 주입은 연소가스의 체류시간, 미연분 제거 및 출구가스 온도 제어 등의 많은 영향을 끼친다. 이에 따라 2차 연소용 공기량을 변화시켜 충분한 체류시간을 확보하고 850℃ 이상의 출구가스 온도를 유지하며, 높은 turbulent를 관리함으로써 안정적인 소각로 운영이 되어야만 한다. 본 연구에서는 현재 운영 중인 소각장의 소각로를 설계하고, 평균 일일 소각량을 바탕으로 1차 공기량을 산정한 후 2차 공기량을 변화하여 CFD 프로그램(Fluent)을 통해 이론적인 공기유동을 규명하였다. 또한 산정된 공기량을 바탕으로 실제 운영 중인 소각장에 적용함으로써 최적의 연소조건을 도출하였다. CFD simulation 결과 1.2차 공기비는 75:25가 최적의 결과로 나타났으며, 2차 공기 분사노즐 전 후면 유속 비는 1:3에서 가장 우수한 결과로 나타났다. 또한, 실제 운영 중인 소각로에 적용한 결과 적절한 소각로 출구온도는 질소산화물 제거 효율 및 일산화탄소 발생농도에 영향을 미치는 것으로 나타났다.
        4,500원
        17.
        2010.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        수집 농산물의 세척, 선별, 포장 작업 등이 이루어지는 APC 작업장은 하절기에 작업자들이 고온의 환경에 노출되므로 작업환경 개선을 위한 냉방공조가 요구되고 있다. 기존의 전체 냉방 공조방식은 과도한 유지비로 인한 운용상의 어려움이 발생하고 있으므로 설비비 및 운용비가 상대적으로 저렴한 시스템을 적용할 필요가 있다. 본 연구에서는 하절기 APC 작업공간의 효율적 냉방을 위한 냉방시스템 설계의 기초 연구로써 CFD를 기반으로 하여 양압식 및 음압식 팬 앤 패드 시스템과 국소냉방 시스템에 대해 열유동 수치해석을 수행하여 각각의 냉방효과를 예측하였다. 그 결과, 음압식 팬 앤 패드 시스템은 고온 외기의 과도한 유업으로 인해 패드 하류의 일부 영역을 제외한 대부분의 작업영역에서 상대적으로 고온의 온도 분포를 보였으며 기류의 유속분포 역시 낮게 나타나 APC 냉방시스템으로 부적합한 것으로 판단되었다. 양압식 팬 앤 패드 시스템은 직업장의 중심부 및 각 작업영역에 비교적 균일한 저온환경을 조성하나 작업자 위치별로 기류의 유속편차가 크게 나타났다. 국소냉방 시스템의 경우 각 작업자 위치의 상부에서 냉기류가 공급되는 방식이므로 팬 앤 패드 시스템에 비해 작업자 위치에서의 온도분포와 기류 유속분포가 상대적으로 균일하게 나타났다. 양압식 팬 앤 패드 시스템은 냉방기를 사용하는 기존의 공조방식에 비해 설비비 및 유지비가 저렴하나, 실제 APC 작업장의 냉방공조에 적용시에는 팬 소음, 고습환경이 선별기 등 장비에 미치는 영향, 용수공급 및 패드교체 등을 고려하여 보다 신중한 검토가 요구된다.
        4,000원
        18.
        2006.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        변화무쌍한 기상변화가 실험의 정확도에 미치는 영향을 최대한 줄일 수 있도록 강제환기식 온실에서 실험을 하였고, 또한 대체적으로 크지 않은 온실에서의 실험으로 인하여 CFD모델결과의 오차를 크게 줄일 수 있었다. CFD와 현장실험 결과를 비교하여 본 결과, 온실내 1m높이에서의 평균풍속이 각각 0.42m·s-1과 0.39m·s-1으로써 CFD의 지점별 오차 평균값은 7.7% 로 나타났다. Y8.5m 지점에서 가장 큰 오차가 발생하였는데, 최대 오차는 -53.8%로 나타났다. 이의 가장 큰 이유로는 온실 길이방향에서 중간지점인 Y8.5m에서 풍속이 매우 작았기 때문에 소숫점 2번째 자리의 차이라고 해도 큰 오차로 나타났다. 작물형상의 기하학적 복잡성이 매우 큰 것을 고려한다면 오차범위는 매우 양호한 것으로 판단된다. 온실내 1m높이에서 평균온도의 CFD 평균오차는 2.2%로 나타났고, 최대편차는 5.5%이었다. 온실내 바닥으로부터의 복사열 발생량의 차이로 인하여 온실내 동쪽 지역에 상대적으로 큰 오차가 발생하였다. 외기 상대습도가 44%일 때, CFD상대습도의 오차는 2.1%이었으며, 최대 오차는 -3.8%이었다. 식물군의 공기유동저항, 식물군의 수분 및 열평형 모델을 추가하여 보다 사실적인 CFD모델을 설계하였다. CFD 모델의 설계방법이 정립되었기 때문에, 추후에 온실내 다른 작물의 미기상 및 이의 온실내 기상에 미치는 영향 등을 정량적으로 분석할 수 있게 되었다. 또한 작물의 적정생육환경에 주요 대상이면서도 동시에 센서설치의 어려움 등으로 인하여 연구에 어려움이 많았던 작물군내 미기상을 연구할 수 있는 토대를 마련하였다.
        4,000원
        1 2