검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 7

        1.
        2006.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Water quality has been deteriorated by the increasing amount of industrial waste water that is due to the better standard of living. In order to lessen the polluted water and substantially reutilize it at factories, a new method is needed. The plasma generator, which uses discharge current below 1,500 voltage and processes at extremely low temperature, has more strong oxidization than current method and an advantage of miniaturizing the apparatus in dealing with waster water by producing carrier gas at room temperature. This study were measured on the 3 kinds of waster water to the plasma generator for 120 minutes. As results, COD was almost decreased and removed in 15 minutes. The results suggest that the plasma generator can be used reduce COD and removal of color for various waster water, which can be reutilized as industrial water, It would be of benefit to the country like Korea in which qualified water is deficient.
        4,000원
        2.
        2021.01 KCI 등재 서비스 종료(열람 제한)
        The purposes of this study were to evaluate the removal characteristics of COD, Ni, and P and to derive appropriate operating conditions for the plating wastewater according to NaOCl reaction time and pH operating conditions in the BPC unit process during the plating wastewater treatment process. As a results of evaluating the removal characteristics for raw wastewater by each BPC unit process, the removal efficiencies of COD, Ni and P in BPC 1-1 unit process were 72.8%, 99.1%, and 100.0%. Therefore, the proper reaction time of NaOCl was derived as 21.1 minutes. In order to maintain the +800 mV ORP and the reaction time of 20 minutes, the temporary injection and continuous injection of NaOCl in the BPC unit process were 13.7 mL and 18.7 mL, respectively. It was found that the temporary injection method of NaOCl reduced the chemical cost by 36.5% compared to the continuous injection method. Also, Ni showed the highest removal efficiency of 97.8% at pH 10.5. On the other hand, P showed a removal efficiency of 57.4% at pH 10.0.
        3.
        2018.10 KCI 등재 서비스 종료(열람 제한)
        In the industrial wastewater that occupies a large proportion of river pollution, the wastewater generated in textile, leather, and plating industries is hardly decomposable. Though dyeing wastewater has generally been treated using chemical and biological methods, its characteristics cause treatment efficiencies such as chemical oxygen demand (COD) and suspended solids (SS) to be reduced only in the activated sludge method. Currently, advanced oxidation technology for the treatment of dyeing wastewater is being developed worldwide. Electro-coagulation is highly adapted to industrial wastewater treatment because it has a high removal efficiency and a short processing time regardless of the biodegradable nature of the contaminant. In this study, the effects of the current density and the electrolyte condition on the COD removal efficiency in dyeing wastewater treatment by using electro-coagulation were tested with an aluminum anode and a stainless steel cathode. The results are as follows: ① When the current density was adjusted to 20 A/m2, 40 A/m2, and 60 A/m2 under the condition without electrolyte, the COD removal efficiency at 60 min was 62.3%, 72.3%, and 81.0%, respectively. ② The removal efficiency with NaCl addition was 7.9% higher on average than that with non-addition at all current densities. ③ The removal efficiency with Na2SO4 addition was 4.7% higher on average than that with non-addition at all current densities.
        6.
        2016.10 KCI 등재 서비스 종료(열람 제한)
        An electrochemical treatment has great efficiency for the removal of non-biodegradable material and it has high applicability in wastewater treatment due to its short operating time. The purpose of this study using an electrochemical process is to provide fundamental data on the cutting fluid treatment, which has difficulties in the treatment of nonbiodegradable material. The results are as follows. Experimental data in relation to applied voltage and concentration of NaCl are outlined. With no addition of NaCl, and an applied voltage of 5 V, 10 V, or 15 V for 60 mins, the removal rates of CODMn were 29.87%, 55.32%, and 67.27% for each voltage. The removal rates of CODCr were 39.51%, 70.73%, and 85.37%, respectively. The removal rates of CODMn and CODCr increased with increasing applied voltage. These experimental results showed that the removal rate of COD with varying concentrations of NaCl (0 mM, 5 mM, 10 mM) increased increasing NaCl concentration.
        7.
        2012.06 KCI 등재 서비스 종료(열람 제한)
        This study elucidates the COD removal of dye (Rhodamine B) through electrochemical reaction. Effects of current density (7.2 to 43.3 mA/cm2), electrolyte type (NaCl, KCl, Na2SO4, HCl), electrolyte concentration (0.5 to 2.0 g/L), air flow rate (0 to 4 L/min) and pH (3 to 11) on the COD removal of Rhodamine B were investigated. The observed results showed that the increase of pH decrease the COD removal efficiency. Whereas, the increase of current density, NaCl concentration and air flow rate caused the increase of the COD removal of Rhodamine B.