검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 55

        1.
        1996.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        An innovative batch electrolytic system consisted of electrolytic basin, which was equipped with DSA(Dimensionally Stable Anode) type insoluble electrode, Ti/IrO2 anode and H-C metal cathode, and flotation separator was developed for the efficient treatment of shipboard emulsified oily wastewater. The electorod cleance and current density of elecrolytic basin to ensure maximum treatment efficiency of oily wastewater was evaluated as 6 mm, 3 A/dm3, respectively. The electrolytic efficiency of oily wastewater was affected by the operationtemperature, and it means that the temperature controller to ensure the stabiity of the process is required. The conductivity in the electrolytic basin was increased with the percentage of sea water in the oily wastewater, and over 90% of treatment efficiency of oily wastewater could be obtained at 7% of sea water. The oil removal rate was increased according to the increase of the quantity of electricity, and the maximum value of electrilyic rate constant was 288 mgoil/A.min. The information obtained from this study might be used for development of an efficient continuous electrolytic system treating the emulsified oily wastewater.
        4,000원
        2.
        2018.05 서비스 종료(열람 제한)
        석탄은 탄화정도에 따라 고품질의 무연탄 및 역청탄(Hard coal)과 아역청탄과 갈탄(Brown coal)으로 크게 분류한다. 무연탄은 고정탄소 함량(85~95%)과 발열량이 높고 수분함량이 낮아 화력발전소 및 연탄 재료로 활용된다. 하지만 저품위 석탄은 발열량이 4,000~6,000kcal/kg으로 낮고, 수분 함량이 30~70%로 높으며, 산소 관능기가 함유된 탄화수소가 높으므로 자연발화 위험성이 높은 등 많은 단점들 때문에 전체 석탄매장량 중 약 절반가량(45%)이나 되지만 상당량이 채굴되지 않고 남아있다(2007, 세계에너지 위원회). 본 연구에서는 풍부한 매장량을 가진 갈탄 등의 고 수분 저급석탄으로부터 바이오메탄을 생산하고자 생물학적 분해효율을 증가시키기 위하여 펜톤산화 및 고전압펄스(High voltage electrical pulses) 전처리를 수행하였다. 실험을 위하여 호주산 갈탄, 캐나다산 갈탄, 러시아산 이탄을 이용하였으며, 펜톤산화 전처리는 석탄을 1mm이하의 입자로 분쇄하여 H2O2/Fe2+비를 75%, 30, 15, 10, 7.5%로 주입하여 120rpm에서 Jar-Tester로 1시간 반응시켰다. 고전압전기충격 전처리는 펜톤산화 전처리실험 조건과 동일하게 시료를 준비하여 고전압 펄스장치를 이용하여 출력전압 40kV에서 15분간 처리하였다. 전처리를 끝낸 시료는 용액의 SCOD와 석탄의 처리 전, 후의 표면분석과 화학조성 변화를 관찰하기 위하여 적외선 흡수 스펙트럼분석(FT-IR)을 수행하였다. 펜톤산화 처리 후 용액의 SCOD농도변화와 SEM촬영 및 FT-IR 분석결과, 전처리 후의 석탄은 바이오메탄 전환율이 높아질 수 있을 것으로 평가되었다.
        3.
        2017.10 KCI 등재 서비스 종료(열람 제한)
        Soluble Cutting Fluids (SCFs) have been used in metal machining processes to improve the quality of metal processing equipment and products. Although SCFs are useful and essential material, wasted soluble cutting fluids are harmful in hydroecological systems because of the high concentration of COD and nitrogen material. If discharged to hydroecological systems without specific treatment, they may cause eutrophication in rivers and lakes. Therefore, the removal efficiency of the COD contained in the SCFs is investigated in this study using electrochemical treatment with an insoluble electrode. The electrode was made of titanium with iridium plating, made from a perforated metal sheet to agitate the sample in the reactor. Cathode and anode electrodes were inserted into acrylic reactor alternately and the reaction time was one hour. The experimental results were as follows: First, for 60 A/m2, 80 A/m2, and 100 A/m2 current densities, the COD removal efficiencies were 42.0%, 63.9%, and 78.4%, respectively.
        4.
        2017.05 서비스 종료(열람 제한)
        상향류식 혐기성 생물전기화학 반응조(upflow anaerobic bioelectrochemical reactor, UABE)를 이용하여 주정폐수를 유기물부하율 16 g COD/L.d에서 처리하는 동안 pH, 알카리도, 유기산 등의 상태변수들의 변화와 COD 제거율, 비메탄발생량 및 메탄함량에 대한 전극배치의 영향을 평가하였으며, 그 성능을 UASB 반응조와 비교하였다. 면적이 27 m²/m³인 전극을 나선형으로 UABE 반응조 전체 공간에 고르게 배치하였을 때 비메탄발생율은 5.78 L/L.d로서, 전극을 설치하지 않은 UASB 반응조의 3.49 L/L.d보다 약 65.6%로 높았다. 이것은 UABE 반응조에 전기활성미생물이 성장하여 직접 종간전자전달(direct interspecies electron transfer, DIET) 반응이 활성화됨으로서 메탄생성반응이 크게 향상되었다는 것을 의미한다. UABE 반응조의 상부 1/3의 공간에 위치한 전극을 제거하였을 때, 비메탄발생율은 5.74 L/L.d로서 반응조 전체 공간에 전극을 설치한 경우와 큰 차이가 없으나, UABE 반응조 상부 2/3 공간에 설치한 전극을 제거한 경우 비메탄발생율은 5.34 L/L.d로 약 7.5% 감소하였다. 이 결과는 UABE 반응조에서 전극을 하부 1/3의 공간에만 설치한 경우 전기활성미생물도 감소하여 DIET 반응도 감소하였다는 것을 의미한다. 전극을 UABE 반응조 하부로부터 2/3 이상의 공간까지 설치하였을 때 COD 제거율은 약 91.5%이었으나 반응조 하부로부터 1/3의 공간에만 설치한 경우 COD 제거율은 88.9%로 약 2.6%로 감소하였다.
        5.
        2016.12 KCI 등재 서비스 종료(열람 제한)
        연안오염퇴적물에 함유된 유기물질과 PAHs의 현장정화를 위한 생물활성촉진제의 효능을 파일럿 규모의 현장실험을 통하여 1년간 평가하였다. 실험 해역의 수온은 계절적인 요인으로 인해 16.5°C에서 21°C까지 변화가 있었으나, 파일럿 반응조의 오염퇴적물의 pH는 8.4-8.5로 서 비교적 일정하였다. 파일럿 실험종료 후 바탕시험구와 초산, 황산이온, 질산이온을 함유한 생물활성촉진제를 주입한 오염퇴적물의 화학적 산소요구량은 각각 39% 및 79%까지 감소하였으며, 휘발성고형물은 초기 약 15 g/kg에서 7 g/kg 및 2.5 g/kg까지 각각 감소하였다. PAHs는 2- ,3- ,4- ,5-ring 과 6-ring 16PAHs를 평가하였으며, 생물활성촉진제를 주입한 오염퇴적물에서 2-ring 화합물인 나프탈렌은 실험시작 2개월 후 100%(바탕시험구의 감소율 55.6%)까지 감소되어 가장 빨랐고, 12개월 후 3-ring 및 4-ring PAHs의 감소율은 모두 100%(바탕시험구의 감 소율 46%-100%)에 달하였다. 5-ring과 6-ring PAHs의 12개월 후의 감소율은 바탕시험구와 생물활성촉진제를 투여한 오염퇴적물에서 각각 26%-87% 및 77%-100%로 평가되었다. 연안오염퇴적물에 투입한 생물활성촉진제는 유기물질 및 난분해물질인 PAHs의 제거속도를 향상시킬 수 있는 것으로 평가되었다.
        6.
        2016.12 KCI 등재 서비스 종료(열람 제한)
        The purpose of this study was to investigate and analyze continuous operation of food waste resources at Dongdaemun Environmental Resources Center and to improve the overall operation of the dry anaerobic digester facility. Korean domestic food wastes consist of 18% total solid (TS) content but food waste is difficult to utilize for dry anaerobic digestion. Other operational trouble-shooting resulted from the inherent design, construction and operation of such a biomass generation facility based on 100% utilization of dewatered cake with 35% TS concentration as feedstock, causing the accumulation of unwanted solid residues. A materials flow analysis obtained from actual operation of the anaerobic digestion facility revealed that the organic material loading rate (OLR) and its residence time were 8.3 kg-VS/m3·day and 18.3 days, which adversely affected stable operation. The OLR was occasionally > 15,000 mg/L organic acid concentration and the facility shut down. Such anomalies drastically reduced biogas production and increased organic matter loading in the wastewater, which exceeded the legally allowed concentration limit. Operation of this facility has been normalized to the targeted facility capacity of 98 m3/day based on the results of this study.
        7.
        2016.12 KCI 등재 서비스 종료(열람 제한)
        As industry continues to develop, the contents of various recalcitrant substances that are not removed by conventional wastewater treatment have increased in modern society. The metal working fluids (MWFs) used in the metal working process contain chemical substances, such as mineral oils, anticorrosive agents, extreme-pressure additives, and stabilizers, as well as high concentrations of organics and ammonia-nitrogen. Accordingly, MWFs are required to develop advanced treatments to conserve hydro-ecological resources. This study investigated the removal efficiency of ammonia nitrogen from MWFs according to operating time, applied voltage, and NaCl concentration using a Ti/IrO2 electrode in a batch-type reactor. The experimental results showed that ammonia-nitrogen removal efficiencies without NaCl were 89% and 92% when voltage was adjusted to 15 and 20 V for 60 min and removal efficiency was 90% at 25 V for 40 min. Removal efficiencies of 10 mM NaCl were 4% and 2% greater than those of not adding NaCl at 15 V for 50 min and 20 V for 30 min.
        8.
        2016.11 서비스 종료(열람 제한)
        2012년 현재, 국내 광공업 중 자동차 및 트레일러 제조업, 금속가공제품 제조업 등 금속가공을 필요로 하는 사업체는 전체 광공업 사업체 중 약 40%를 차지하고 있으며, 이와 같은 금속가공 과정에서 필요로 하는 것이 절삭유이다. 그러나 절삭유 내에는 50~80% 정도의 미네랄 오일 외에 amins, carboxylates, chlorine, glycols와 같은 부식방지제, 안정제, 습윤제, 극압 첨가제 등 20여종 이상의 화학성분이 다량 함유되어 있으며, 인체에 지속적으로 노출 시 호흡기 자극, 천식, 폐렴, 피부염, 모낭염 및 피부암 등을 일으키게 된다. 또한 고농도의 유기성분이 함유되어 있으며 유기성분 외에도 금속가공유 내 함유된 암모니아성 질소는 수생태계에 방류되면 부영양화 및 녹조현상과 같은 문제를 일으키며, 수중에서 산화반응을 하여 아질산성 질소와 질산성 질소로 변화되면서 수계의 용존산소를 감소시켜 수계 내 오염을 일으켜 각별한 처리가 필요하다. 따라서 본 연구에서는 수용성 절삭유의 효율적인 처리를 위해 용성전극인 알루미늄과 SUS316전극을 이용하여 전극간격, 전압, NaCl 농도변화를 통해 암모니아성 질소 제거 효율에 미치는 영향을 검토하여, 전극 특성과 각 인자에 따른 제거양상을 비교하였다. 본 연구에서 사용한 시료는 수용성 절삭유 W1-1종을 초순수와 함께 5%(V/V) 희석하여 사용하였으며 성상은 Table 1과 같다. 장치구성은 반응조, 전극, 전원공급장치, 전압안정기(AVR)로 진행하였으며, 장치모식도는 다음 Fig. 1에 나타내었다.
        9.
        2016.10 KCI 등재 서비스 종료(열람 제한)
        Generally, metal working fluids (MWFs) are used to reduce friction in metalworking processes. In addition to mineral oils, MWFs contain many chemical substances, such as anticorrosive agents, extreme-pressure additives, and stabilizers, as well as high concentrations of organics and ammonia nitrogen. Accordingly, MWFs must be managed to advanced treatment for hydro-ecological conservation. This study investigated the removal efficiency of ammonia nitrogen from MWFs according to operating time, applied voltage, distance between electrodes, and NaCl concentration using aluminum in a batch-type reactor. The experimental results were as follows: First, without NaCl, removal efficiencies of ammonia nitrogen were 69.6%, 37.9%, and 22.7%, when the distance between electrodes was adjusted to 1, 4, and 7 cm, respectively, at 15 V for 60 min. Secondly, without NaCl, removal efficiencies of ammonia nitrogen were 49.5 and 90.9% when the voltage was adjusted to 5 V and 10 V, respectively, for 60 min and 94.6% at 15 V for 40 min. Lastly, with the addition of NaCl 10 mM, the removal efficiency of ammonia nitrogen was 40.3% and 11.5% greater than that of no addition of NaCl at 5 V for 60 min and at 10 V for 30 min.
        10.
        2016.10 KCI 등재 서비스 종료(열람 제한)
        An electrochemical treatment has great efficiency for the removal of non-biodegradable material and it has high applicability in wastewater treatment due to its short operating time. The purpose of this study using an electrochemical process is to provide fundamental data on the cutting fluid treatment, which has difficulties in the treatment of nonbiodegradable material. The results are as follows. Experimental data in relation to applied voltage and concentration of NaCl are outlined. With no addition of NaCl, and an applied voltage of 5 V, 10 V, or 15 V for 60 mins, the removal rates of CODMn were 29.87%, 55.32%, and 67.27% for each voltage. The removal rates of CODCr were 39.51%, 70.73%, and 85.37%, respectively. The removal rates of CODMn and CODCr increased with increasing applied voltage. These experimental results showed that the removal rate of COD with varying concentrations of NaCl (0 mM, 5 mM, 10 mM) increased increasing NaCl concentration.
        11.
        2016.09 KCI 등재 서비스 종료(열람 제한)
        A bioelectrochemical anaerobic digester for food waste was developed by installing an anode (−250 mV vs. Ag/AgCl) and a cathode (−550 mV vs. Ag/AgCl) inside a conventional lab-scale anaerobic digester. The performance of the bioelectrochemical anaerobic digester was investigated at different organic loading rates of 0.70-4.25 g VS/L.d. The bioelectrochemical anaerobic digester was rapidly stabilized within 25 days after start up, and at an organic loading rate of less than 1.97 g VS/L.d., state variables such as pH (7.0-7.8) and alkalinity (10-12 g/L as CaCO3) were very stable. The volatile fatty acids were maintained at 400-500 mg HAc/L with their main component being acetic acid (80%). At an organic loading rate of 1.97 g VS/L.d, the performance was significantly high in terms of the specific methane production rate (1.37 L CH4/L.d) and the methane content in the biogas (around 74%). The removal efficiencies of volatile solid and chemical oxygen demand were also as high as 80.1% and 85.1%, respectively, and the overall energy efficiency was 91.2%. However, the process stability deteriorated at an organic loading rate of 4.25 g VS/L.d.
        12.
        2015.11 서비스 종료(열람 제한)
        미생물연료전지(Microbial fuel cells, MFCs)의 성능은 미생물이 부착 성장하는 산화전극의 활성에 의해 크게 영향을 받는다. 미생물연료전지의 산화전극 활성은 전극표면의 높은 생물친화도, 미생물이 부착성장 할 수 있는 넓은 표면적, 전기전도도 등에 의해서 결정된다. 지금까지 연구되어 온 미생물연료전지의 산화전극 재료들은 주로 다공성유리탄소, 탄소천, 탄소섬유 브러쉬, 흑연펠트, 흑연섬유 등의 탄소계열의 전도성 물질들이었다. 그러나, 이러한 탄소계열 물질들은 그 종류에 따라 비표면적이 작거나, 표면이 소수성이며, 금속과 비교할 때 전도성이 좋지 않은 특성을 가진 것들이 많다. 그러나, 서로 다른 특성을 가지는 탄소계열 물질들을 동시에 사용함으로서 각각의 재료들이 가지는 단점들을 보완함으로서 높은 활성을 가지는 미생물연료전지 산화전극을 제작하고자 하는 시도들이 이루어지고 있다. 그러나, 탄소계열 물질들을 동시에 사용하기 위해서는 이러한 재료들을 서로 혼합하고 내부적으로 결합시키기 위한 결합제가 반드시 필요한데 완성된 산화전극의 활성은 결합제의 종류에 의해서 크게 영향을 받는다. 지금까지는 주로 Nafion 용액, 에폭시 등의 고분자 물질들을 결합제로 사용하여 왔는데, Nafion 용액은 전도성 높고 친수성 물질이라는 장점이 있지만 부착력이 낮고 가격이 비싼 고가의 물질이라는 한계점을 가지고 있다. 또한, Epoxy는 부착력이 강한 반면 전도성이 없는 소수성 물질이라는 단점이 있다. 본 연구에서는 콜타르 피치(Coal tar pitch, CTP)에 니켈(Nickel, Ni)을 다양한 비율로 혼합하여 결합제를 제조하고, 이를 이용하여 제작한 팽창흑연과 탄소나노튜브 산화전극의 성능을 회분식 미생물연료 전지를 이용하여 평가하였다. 산화전극 제작에 사용된 결합제의 CTP 양이 적을수록, 전기적 활성은 증가하였으나 부착력이 크게 감소하였다. 또한, CTP에 Ni 함량이 증가할수록 산화전극 표면에 부착 성장한 미생물 생체량이 증가하였으며, 내부저항이 점차 감소하였다. CTP 4g과 Ni 5.9mmol을 혼합하여 제조한 결합제로 제작한 산화전극의 경우 미생물연료전지의 최대전력밀도는 738.11 mW/m²로서 가장 큰 값을 보였으며, 내부저항은 146.19 Ω로서 가장 낮았다. 이 값은 Nafion 용액을 결합제로 사용하여 제작한 대조구 산화전극과 비교할 때 최대전력밀도는 23.68% 높았으며, 내부저항은 33.82% 낮았다. CTP와 Ni을 혼합한 물질은 미생물연료전지의 산화전극제작에 사용할 수 있는 우수한 결합제이다.
        13.
        2015.08 KCI 등재 서비스 종료(열람 제한)
        실험실 규모의 관 실험을 통하여 연안오염퇴적물의 생물정화 효능에 대한 생물활성촉진제 주입 깊이의 영향을 평가하였다. 생물활성 촉진제를 실험관에 충진 된 오염퇴적물의 표면과 표면으로부터 3cm, 6cm, 10cm 위치에 주입한 후 1개월 및 3개월 후 퇴적물의 유기물 및 중금 속의 특성 변화를 조사하였다. 시험 오염퇴적물의 화학적 산소요구량, 총고형물 및 휘발성고형물 함량은 생물활성촉진제를 주입하지 않은 대조 구에 비해 1개월 후 및 3개월 후에서 크게 감소하였으며, 생물활성촉진제 주입 깊이 3cm에서 최대값을 보였다. 그러나, 오염퇴적물에 주입한 생물활성촉진제의 깊이를 6cm 및 10cm로 증가하였을 때 유기오염물질 감량정도는 점차 감소하였다. 중금속 존재형태변화는 생물활성촉진제 주입 깊이 3cm에서 안정한 형태인 유기물 결합분율과 광물내 잔류분율이 현저하게 증가하였다. 오염퇴적물의 현장생물정화를 위한 최적의 생 물활성촉진제 주입 깊이는 퇴적물의 상부 표면으로부터 3cm로 평가되었다.
        14.
        2015.05 서비스 종료(열람 제한)
        유기성폐기물을 안정화시키는 동시에 바이오가스를 회수하는 혐기성소화기술은 지난 백여년 이상동안 많은 연구자들에 의하여 연구되어 온 전통기술로서 최근 지구온난화 문제가 전 세계적인 이슈로 부상하면서 새롭게 조명 받고 있다. 그러나, 혐기성소화기술은 여전히 메탄생성균의 느린 성장속도와 환경변화에 대한 민감성에 기인하여 20일 이상의 긴 체류시간을 필요로 하고 유기물 감량율과 메탄생성율이 높지 않다는 단점이 있다. 또한, 혐기성소화조는 성능을 유지시키기 위하여 중온(35℃) 또는 고온(55℃) 조건에서 운전하게 되는데, 소화조의 온도를 일정하게 유지시키기 위하여 가온하는데 많은 에너지를 필요로 한다. 그러나, 혐기성소화조를 저온에서 운전하게 될 경우 가온에 필요한 에너지를 절약할 수 있지만 생화학반응속도가 감소하여 소화성능이 크게 저하하는 결과로 이어지게 된다. 한편, 생물전기화학 혐기성소화(bioelectrochemical anaerobic digestion)는 재래식 혐기성소화가 가진 단점들을 극복하기 위하여 기존의 혐기성소화조에 산화전극과 환원전극으로 이루어진 생물전기화학장치를 설치하고 전극들에 일정한 전위를 인가함으로서 유기물의 혐기성분해 반응을 촉진시키는 기술이다. 본 연구에서는 하수슬러지를 대상으로 25℃의 저온조건에서 생물전기화학 혐기성소화성능을 평가하고, 중온조건에서의 결과와 비교하였다. 또한, 저온소화 성능에 대한 철염의 영향을 조사하였다. 본 연구는 교반기가 설치된 유효용량 12L의 재래식 혐기성소화조에 산화전극과 환원전극을 설치한 생물전기화학 혐기성소화조를 이용하여 수행하였다. 이때 산화전극은 흑연직물섬유의 표면에 탄소나노튜브를 전기영동전착법으로 고정시킨 것을 사용하였으며, 환원전극은 흑연직물섬유의 표면에 탄소나노튜브와 니켈을 동시에 고정시킨 것을 사용하였다. 준비된 생물전기화학 혐기성소화조의 산화전극과 환원전극 사이에는 외부의 직류전원을 이용하여 0.3V의 전압을 인가하였다. 초기운전을 위하여 S 하수처리장 혐기성소화조로부터 채취한 혐기성슬러지를 식종하였으며, Y 하수종말처리장에서 채취한 하수슬러지를 1일 1회 정량 주입하여 수리학적 체류시간은 20일로 유지하였다. 생물전기화학 혐기성소화조를 운전하는 동안 pH, VFA, COD 및 VS 그리고 바이오가스발생량 및 메탄함량과 전류의 변화 등을 관측하였다. 생물전기화학 혐기성소화조를 35℃의 중온에서 운전한 경우 초기운전기간 이후 정상상태에 도달하였을 때 비메탄발생율과 VS 감량은 각각 0.412L CH4/L/d 및 72.5%로서 대단히 우수한 소화성능을 보였다. 그러나, 생물전기화학 혐기성소화조를 저온에서 운전하였을 때 메탄발생량과 유기물 감량율은 전차감소하였으며, 정상상태에서 비메탄발생율과 VS 감량은 각각 0.354 L CH4/L/d 및 61.3%로서 중온조건의 85% 정도 소화성능을 보였다. 그러나, 유입슬러지에 철염을 첨가하여 생물전기화학 혐기성소화조를 운전하였을 때 메탄발생량과 VS 감량율은 빠르게 회복하였으며, 비메탄발생량과 VS 감량은 각각 403L CH4/L/d 및 69.8%로서 중온성능의 98% 가량의 성능을 보였다.
        15.
        2014.11 서비스 종료(열람 제한)
        혐기성소화기술은 지난 백여년 이상동안 많은 연구자들에 의하여 연구되어 온 전통기술로서 최근 지구온난화 문제가 전 세계적인 이슈로 부상하면서 새롭게 조명 받고 있다. 그러나, 혐기성소화기술은 여전히 메탄생성균의 느린 성장속도와 환경인자에 대한 민감성에 기인하여 20일 이상의 긴 체류시간을 필요로 하고 유기물감량율이 낮으며, 운전조건이 까다롭다는 단점을 지니고 있다. 최근 들어 환경생물전기화학자들에 의해 연구되기 시작한 생물전기화학기술(Bioelectrochemical technology)을 혐기성소화공정에 활용하면 메탄생성반응과 가수분해반응을 크게 촉진시킬 수 있어 전통적인 혐기성소화기술의 단점들이 상당 부분 극복할 수 있다. 혐기성소화공정에 활용하는 생물전기화학기술은 소화조 내에 설치하는 산화전극과 환원전극으로 이루어지며, 외부회로에 의하여 서로 연결된 산화전극과 환원전극 사이에 외부전원을 이용하여 전압을 인가하여 일정한 전위차가 유지되도록 한 미생물전해전지(Microbial electrolysis cells, MECs)의 형태이다. 혐기성소화조에서 전기적으로 활성을 가진 미생물들은 유기물이나 유기산을 빠른 속도로 분해하여 전자와 양성자를 생성하며, 전자는 산화전극으로 전달된 뒤 외부회로를 통하여 환원전극으로 이동한다. 환원전극의 표면에서는 전자와 양성자 또는 전자와 양성자 및 이산화탄소가 반응하여 수소나 메탄과 같은 바이오가스가 생성된다. 본 연구에서는 완전혼합형 혐기성소화조에 생물전기화학장치가 설치된 반응조 (Bioelectrochemical anaerobic digestion, BEAD)을 이용하여 수리학적 체류시간에 따른 PTA 폐수의 처리특성을 평가하였다. PTA (purified terephthalic acid) 폐수는 A 산업에서 채취한 것으로서 COD 값이 약 6,000-8,000mg/L였으며, 주요 구성성분은 terephthalic acid, p-toluic acid, benzoic acid, acetic acid 등이었으며, pH는 5-6이었다. 먼저, 실험에 사용한 산화전극 및 환원전극은 흑연직물 섬유의 표면에 탄소나노튜브를 초음파분산법으로 고정하여 제작하였다. 교반기가 설치된 유효부피 15L의 원통형 혐기성 소화조에 산화전극과 환원전극을 각각 설치하였으며, 산화전극과 환원전극 사이에 0.3V의 전압을 인가하였다. 하수슬러지를 이용하여 운전 중인 생물전기화학장치가 설치된 혐기성소화조에서 유출 슬러지를 초기 운전을 위한 식종균으로 사용하였으며, PTA 폐수를 1일 1회 정량 주입하여 수리학적 체류시간을 20일로 유지하였다. 소화조가 안정화되었을 때 수리학적 체류시간을 단계적으로 10일, 5일, 2.5일 그리고 1.25일 까지 변화시키면서 총 바이오가스발생량 및 메탄함량, COD 제거율과 전류의 변화 등을 관측하였다. 생물전기화학장치가 설치된 혐기성소화조의 COD 감량율은 수리학적 체류시간에 관계없이 약 60%로서 보였으며, 바이오가스의 메탄함량(%)은 80% 이상을 유지하였다. 그러나, 메탄발생량은 수리학적 체류시간의 감소에 따른 유기물 부하율 증가에 비례하여 증가하였다. 그러나, 외부회로의 전류와 메탄가스 발생량으로부터 계산한 쿨롱효율은 수리학적 체류시간이 감소에 따라 오히려 증가하였다. COD 제거율, 바이오가스의 메탄함량 및 메탄가스발생량으로 평가한 생물전기화학장치가 설치된 혐기성소화공정의 안정성은 수리학적 체류시간 20일부터 1.25일의 범위에서 영향을 받지 않았다.
        16.
        2014.07 KCI 등재 서비스 종료(열람 제한)
        Seven tetracycline classes of antibiotics were treated using ultraviolet (UV) and UV/H2O2 oxidation. Two different UV lamps were used for the UV and UV/H2O2 oxidation. The performance of the UV oxidation was different depending on the lamp type. The medium pressure lamp showed better performance than the low pressure lamp. Combining the low pressure lamp with hydrogen peroxide (H2O2) improved the removal performance substantially. The by-products formation of tetracycline by UV and UV/H2O2 were investigated. The protonated form ([1 + H]+) of tetracycline was m/z 445, reacted to yield almost exclusively two oxidation by-products by UV and UV/H2O2 oxidation. Their protonated forms of by-products were m/z 461 and m/z 477. The structures of tetracycline’s by-products in UV and UV/H2O2 system were similar.
        17.
        2014.06 KCI 등재 서비스 종료(열람 제한)
        자생하는 미생물의 활성을 촉진시킴으로써 오염된 연안퇴적물을 현장생물정화하기 위하여 사용하는 미생물활성촉진제의 용출특성에 대한 연구를 수행하였다. 미생물의 생리활성을 촉진하는 황산염, 질산염을 오염되지 않은 연안퇴적물과 혼합하였으며, 혼합물을 볼 형태로 만 든 뒤 셀룰로스 아세테이트 및 폴리설펀으로 각각 표면을 코팅하여 볼 형태의 미생물활성촉진제 2종을 제작하였다. 또한, 황산염과 질산염이 용해된 생리활성물질 용액에 입상활성탄을 침지시켜 입자상 미생물활성촉진제를 별도로 준비하였다. 셀룰로스 아세테이트로 코팅한 미생물활 성촉진제를 전자현미경으로 관찰한 결과 코팅층 내부는 다소 큰 공극이 불규칙적으로 존재하였으나 코팅층 외부는 촘촘한 벌집모양의 공극들 이 분포되어있었다. 폴리설펀으로 코팅한 미생물활성촉진제의 경우는 코팅층의 내부와 외부 모두 공극이 없는 치밀한 구조를 보였다. 셀룰로스 아세테이트로 코팅한 미생물활성촉진제의 생리활성물질 용출율은 폴리설펀으로 코팅한 미생물활성촉진제에 비해 증류수와 해수에서 모두 높 았으며, 입자상 미생물활성촉진제로부터의 생리활성물질의 용출율은 폴리설펀으로 코팅한 미생물활성촉진제에 비해 약 9배 이상 높았다. 미생 물활성촉진제로부터 생리활성물질들의 용출속도는 정체조건에 비해 난류조건에서 약 3배 이상 빠른 것으로 평가되었으며, 생리활성물질들 중 에서 질산염은 황산염에 비해 빠르게 용출되는 특성을 보였다.
        18.
        2013.11 서비스 종료(열람 제한)
        미생물전해전지(Microbial Electrolysis Cells, MECs)는 산화전극과 환원전극 사이에 적당한 전위차가 유지되도록 외부전원을 이용하여 전압을 인가함으로서 산화전극 표면에 부착 성장하는 전기적으로 활성을 가진 미생물에 의한 유기물 분해를 촉진시키고 수소나 메탄과 같은 유용물질을 생성시키는 장치이다. 따라서, 최근 미생물전해전지를 이용하여 유기성 폐수의 처리 및 에너지회수를 위한 연구들이 활발하게 진행되고 있다. 미생물전해전지의 운전과 성능에서 미치는 가장 중요한 인자 중의 한 가지는 전극이다. 지금까지 미생물전해전지 연구에 사용되어온 전극들은 대부분 전기전도성이 낮거나 부식이 문제가 된 경우가 많아 실용화에 걸림돌이 되고 있다. 여러 가지 전극재료들 중 흑연섬유직물(GFF; Graphite Fiber Fabric)은 내구성이 강하고 비표면적이 넓지만 전기전도성이 낮다는 단점이 있으며, 탄소나노튜브(Carbon Nanotube, CNT)는 전도성이 대단히 우수한 물질이지만 전극으로 성형, 가공하기 위한 제작기술이 없는 상황이다. 본 연구에서는 흑연섬유직물의 표면에 탄소나노튜브를 전기영동전착법(Electrophoretic deposition, EPD)으로 고정함으로서 내구성이 높고 비표면적과 전도성이 우수한 전극을 제작하기 위한 연구를 수행하였다. 탄소나노튜브를 흑연섬유직물의 표면에 전착시키기 위하여 먼저, 탄소나노튜브(1g)와 PEI(Polyethylenimine) 및 nickel pyrite(PEI1000-Ni500ppm, PEI500-Ni250ppm, PEI500- Ni500ppm)를 초순수 1L에 혼합한 다음 초음파를 이용하여 분산시켜 전기영동 용액을 준비하였다. 면적이 동일한 흑연섬유직물(Working Electrode: GFF)과 스텐리스망(Counter Electrode: stainless steel mesh)을 전기영동 용액에 평행하게 고정하고 두 전극 사이에 전압을 인가하여 전착시켰으며, 200℃에서 열처리를 하여 미생물전해전지용 전극을 제작하였으며, 전자현미경(Scanning Electron Microscope, SEM)을 이용하여 흑연섬유직물의 표면에 전착된 탄소나노튜브의 상태를 확인하였다. 준비된 전극들은 1cm² 크기로 잘라 four-point법으로 저항 측정하였다. 흑연직물섬유은 저항이 0.115Ω/cm이었으나, 탄소나노튜브가 표면에 전착된 흑연섬유직물 전극의 저항은 크게 감소하였다. 특히, 탄소나노튜브 및 PEI500-Ni250ppm으로 구성된 전기영동용액으로 탄소나노튜브를 표면에 전착한 흑연섬유직물 전극은 저항이 0.006Ω/cm로서 코팅하지 않은 흑연섬유직물 보다 전기전도성이 약 20배 증가하였다. 탄소나노튜브를 전기영동법으로 흑연섬유직물의 표면에 전착한 전극은 비표면적이 넓고 부식성이 강한 고전도성의 우수한 미생물전해전지용 전극으로 사용 할 수 있을 것으로 판단된다.
        19.
        2013.11 서비스 종료(열람 제한)
        지금까지 연구된 여러 가지 형상의 미생물연료전지들의 특징들을 조합하여 운전이 용이하고 규모확대가 가능하며 전력생산 성능이 대단히 우수한 3차원 공기환원전극 미생물연료전지를 고안하였으며, 합성폐수를 이용한 성능시험을 수행하였다. 본 연구에 사용된 3차원 공기환원전극 미생물연료전지는 1개의 산화전극부, 4개의 배수구, 그리고 산환전극부 상부에 설치된 1개의 환원전극부로 구성하였다. 미생물연료전지 하단에는 다공판으로 된 유입부를 설치하여 폐수가 산화전극부로 유입되도록 하였으며, 폐수는 산화전극부를 통과한 뒤 환원전극부의 배수구로 이동하도록 설계되었다. 산화전극부에는 EG(Expended Graphite)와 MWCNT(Multi-Wall Carbon Nano Tube)를 스테인리스망에 스크린 프린팅하여 제작된 산화전극을 설치하였고, 환원전극부에는 EG(Expended Graphite)와 MWCNT(Multi-Wall Carbon Nano Tube)에 FePc 및 CuPc를 고정한 촉매를 스테인리스망에 스크린 프린팅하여 제작된 환원전극을 설치하였다. 배수로는 환원전극의 높이의 1cm, 2cm, 3cm, 5cm에 배수구를 각각 설치하여 환원전극 침지깊이에 대한 영향을 평가하였다. 준비된 미생물연료전지는 초기운전을 위하여 혐기성 소화조에서 채취한 슬러지를 식종하였으며, acetate, phosphate buffer solution, minerals, vitamins로 구성된 합성폐수를 연속 주입하였다. 미생물연료전지를 운전하는 동안 DMM(digital multimeter, Keithley 2700)과 컴퓨터를 이용하여 전지에서 발생하는 전압을 관측하였다. 환원전극부의 침지깊이를 변화시킨 뒤 전압이 안정화 되었을 때 외부회로를 개방하여 OCV 값을 측정하였으며, 외부저항을 단계적으로 감소시키는 방법으로 분극실험을 수행하였다. 이때 미생물연료전지에서 얻어진 최대전력수율은 환원전극의 침지깊이에 따라서 1cm < 5cm ≦ 2cm < 3cm 순으로 측정되었다.
        20.
        2013.11 서비스 종료(열람 제한)
        미생물연료전지의 전극재료 중 결합제는 전극의 성능, 내구성 및 비용 등을 결정짓는 핵심 물질 중 하나이다. 전극의 결합제는 기본적으로 전극을 구성하는 기본물질들과 결합력이 좋아야 하고, 전극물질들과 집전체간의 전자전달이 가능한 물질이여야 한다. 따라서, 전극 결합제는 미생물연료전지의 성능향상을 위해 필수적인 역할을 담당한다. 좋은 결합제는 전극의 성능을 향상시킬 수 있어야 하고, 전극물질과의 접착력과 전극물질의 본성 등을 유지시킬 수 있어야 한다. 지난 수년 동안 미생물연료전지의 성능향상을 위해 다양한 결합제에 대한 연구가 이루어 졌으며, 결합제를 활용하기 위한 다양한 기술들이 연구되어 왔다. 현재, 많은 연구자들이 여러 장점들을 가지고 있는 탄소나노튜브를 미생물연료전지의 산화 및 환원전극 제조를 위한 기초물질로 이용하고 있는데, 탄소나노튜브는 가공성이 나쁘고, 용해성이 낮은 등 전극제작에 있어서 몇몇 결점들을 가지고 있다. 이러한 탄소나노튜브의 결점을 보완하면서 친수성이고, 전도성이 높은 결합제로 종종 Nafion 용액을 사용해오고 있는데 이는 고가이며, 결합력이 약하여 미생물연료전지의 실용화에 걸림돌이 되고 있다. 실리카겔은 친수성물질로 알려져 있으며, 물을 따라 이동하는 양이온의 전도성이 좋은 물질로 평가된다. 또한, 헤테로 다중산은 양이온 전도성을 향상시킨다는 많은 연구결과들이 보고된 바 있다. 따라서, 본 연구에서는 헤테로 다중산과 실리카겔을 미생물연료전지의 전극 결합제로 사용하여 고가의 전극결합제인 Nafion 용액을 대체하고자 하였다. 헤테로 다중산을 실리카겔에 도핑하여 결합제를 제조하고 이를 환원전극제작에 사용하였다. 제작된 환원전극의 성능은 3차원 공기환원전극 미생물연료전지를 이용하여 평가한 결과 전력밀도 및 내구성이 헤테로 다중산을 실리카겔에 도핑한 결합제를 이용한 환원전극의 성능이 Nafion 용액을 결합제로 사용한 환원전극보다 우수한 것으로 평가되었다. 헤테로 다중산을 실리카겔에 도핑하여 제조한 결합제는 큰 고가의 Nafion 용액을 대체할 수 있을 것으로 평가되었다.
        1 2 3