검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 14

        2.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In general, small and medium-sized computer rooms do not have access floors for reasons of increased floor height and increased construction cost. Therefore, the air conditioning method used here applies the method of directly blowing the cold air of the air conditioner into the computer room. In this case, the hot/cold air is not separated, and as the hot air is recirculated, it is re-introduced to the front of the server rack, resulting in a problem that the server cooling efficiency is decreased. In addition, in such a computer room structure, it is difficult to configure and install a containment system. In this study, we tried to understand the problem of the formation airflow in the case of using the existing air conditioning method, and to find a method of configuring the air conditioning environment to improve the cooling efficiency. The purpose of this study was to understand the airflow/temperature distribution in the computer room using the CFD simulation method. In addition, the thermal characteristics of various air-conditioning environments such as the location of the CRAC cold air discharge location, the layout between server rack and CRAC and the containment were reviewed.
        4,000원
        3.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, heat exchangers used in data center and building air-conditioners were tested according to the type of heat exchangers to select them for commercial use. The experiment was performed three samples, one micro channel heat exchanger, the same volume oval coil and the same performance oval coil. The experiment conducted under actual operation conditions in the data center and building. Micro-channel heat exchanger has lower air side pressure drop and higher capacity per volume than oval coil. It may be advantageous when the installation small space or the little design static pressure in the fan, such as in-row systems or CRAC installed in data center.
        4,000원
        4.
        2019.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Indirect evaporative coolers (IECs) are widely used for cooling of outdoor air in building air-conditioning and for cooling of indoor air in data center air-conditioning. However, for each case, the inlet air temperature and humidity condition to IEC are different, which may yield different cooling efficiency. In this study, tests were conducted at the two air conditions using two IEC samples having different channel pitch (3 mm × 5 mm, 5 mm × 5 mm). Results showed that the efficiencies of the 3 mm × 5 mm sample were 12~32% larger than those of the 5 mm × 5 mm sample due to 25% larger heat transfer area and the usage of smaller diameter channel. The efficiency was 10% larger at the data center condition than at the building condition. The reason may be attributed to a larger absolute humidity difference between the liquid film and the air at the data center condition. At the same air velocity, the pressure drops at the wet channel were 64~128% larger than those at the dry channel due to the presence of liquid film at the wet channel. Comparison of the data with predictions by the analytical model revealed that both the efficiency and the pressure drop were over-predicted. Possible reason may be the simplification of the channel geometry and the assumption of fully developed flow, which may be improved in the future.
        4,000원
        5.
        2018.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목적 : 본 연구는 국가치매관리사업과 관련된 공공데이터를 수집하여 치매안심센터에서 시행되는 작업치료 의 비용편익분석을 통해 미래의 국가치매관리사업의 효율화 방안을 모색하고자 한다. 연구방법 : 2016년 1월부터 12월까지의 국가치매관리사업 관련 공공데이터를 정보공개 창구를 이용하여 수집하였다. 수집된 자료를 토대로 작업치료 비용편익분석을 위한 각종 변수를 정의하고, 빈도분석 및 산술계산으로 변수의 값을 산출했다. 결과 : 우리나라에서 서울은 모든 자치구에서 치매관리사업을 시행하고 있고, 사업수행인원 전원이 전담인력으로 배치되어 있다. 특히 작업치료 전담인력을 치매안심센터의 96.0%에 배치하여 치매안심센터 서비스에서 작업치료를 제공하고 있다. 치매안심센터에서 시행되는 작업치료의 순 편익은 작업치료 전담인력이 배치된 경우 서울에서 약 73억 원으로 산출되었다. 결론 : 서울과 같은 형태로 국가치매관리사업 사업을 확대하고, 작업치료 전담인력을 통한 프로그램 시행으로 치매관리비용을 절감하는 효과가 있을 것으로 기대된다. 치매 국가책임제 추진으로 치매관리사업이 국가 단위의 보건사업으로 발돋움하고 있는 지금 한정된 보건의료자원을 효율적으로 사용하기 위해서는 치매안심센터에서 작업치료의 확대가 필요할 것으로 보인다.
        4,600원
        6.
        2012.09 KCI 등재 구독 인증기관·개인회원 무료
        Among the AKARI all-sky survey data, the 9 μm diffuse map is crucial to study the polycyclic aromatic hydrocarbon (PAH) emission features on large spatial scales, while the 18 μm map is useful to trace hot dust emission. To utilize these advantages, we have improved the AKARI mid-infrared (MIR) all-sky survey diffuse maps. For example, we have established special methods to remove the effects of the ionizing radiation in the South Atlantic Anomaly (SAA) and of the scattered light from the moon. Using improved diffuse map data, we study the properties of PAHs and dust in the Galactic center region associated with high-energy phenomena.
        8.
        2010.05 구독 인증기관 무료, 개인회원 유료
        The costs of large computing facilities like data centers were dominated by the costs of the information technology (IT) equipment that they have in 1990s. As the indirect cost of IT has increased, Total Cost of Ownership(TCO) analysis is required to find the lifetime costs of acquiring, operating, and changing IT equipment. Nowadays, electricity-related costs such as the electrical power used by IT equipment and the facility costs associated with powering and cooling IT equipment has sharply grown. Nonetheless, those electricity-related costs have been underestimated up to now. In this paper, we will develop TCO model for a high performance computing data center and perform TCO analysis. We will also show that the trend towards growing electricity-related IT equipment costs continue, direct IT equipment acquisition costs will not be an critical factor of the economics of computing services.
        3,000원
        9.
        2006.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
          The instance-based learning is a machine learning technique that has proven to be successful over a wide range of classification problems. Despite its high classification accuracy, however, it has a relatively high storage requirement and because it mus
        4,000원
        10.
        2005.10 구독 인증기관 무료, 개인회원 유료
        Instance-based learning methods like the nearest neighbour classifier have been proven to perform well in pattern classification on many fields. Despite their high classification accuracy, they suffer from high storage requirement, computational cost and sensitivity to noise. In this paper, we present a data reduction method for classification techniques based on entropy-based partitioning and center instances. Experimental results show that the new algorithms achieve a high data reduction rate as well as classification accuracy.
        4,000원
        11.
        2003.12 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        We present results of a H13CN J=1-0 mapping survey of molecular clouds toward the Galactic Center (GC) region of -1.6° ≤ l ≤ 2° and -0.23° ≤ b ≤ 0.30° with 2' grid resolution. The H13CN emissions show similar distribution and velocity structures to those of the H12CN emissions, but are found to better trace the feature saturated with H12CN (1-0). The bright components among multi-components of H12CN line profiles usually appear in the H13CN line while most of the dynamically forbidden, weak H12CN components are seldom detected in the H13CN line. We also present results of other complementary observations in 12CO (J=1-0) and 13CO (J=1-0) lines to estimate physical quantities of the GC clouds, such as fractional abundance of HCN isotopes and mass of the GC cloud complexes. We confirm that the GC has very rich chemistry. The overall fractional abundance of H12CN and H13CN relative to H2 in the GC region is found to be significantly higher than those of any other regions, such as star forming region and dark cloud. Especially cloud complexes nearer to the GC tend to have various higher abundance of HCN. Total mass of the HCN molecular clouds within |l|≤ 6° is estimated to be ~2 ×10 7 M⊙ using the abundances of HCN isotopes, which is fairly consistent with previous other estimates. Masses of four main complexes in the GC range from a few 10 5 to ~ 10 7 M⊙ All the HCN spectra with multi-components for the four main cloud complexes were investigated to compare the line widths of the complexes. The largest mode (45 km s-1) of the FWHM distributions among the complexes is in the Clump 2. The value of the mode tends to be smaller at the farther complexes from the GC.
        4,300원
        13.
        2013.08 KCI 등재 서비스 종료(열람 제한)
        정박중인 선박의 안전을 위하여 항해사, 선장 및 해상교통관제사는 항상 선박이 주묘되고 있는가를 확인하여야 한다. 정박선의 주묘판별을 위하여 VTS 관제사가 선회권과 그 중심을 인지하는 것이 중요하다. VTS에서 정박선 주묘여부 감시는 레이더 및 AIS를 이용할 수 있다. 또한 이용가능하다면, CCTV 영상이나 육안에 의한 관측도 이루어 질 수 있다. 그러나 VTS 시스템은 AIS 및 ARPA Radar로부터 수집된 데이터만으로 정박선을 모니터링하고 있으므로 정박지내에서 정박선의 선회중심을 알기가 어렵다. 본 연구에서는 VTS에서 AIS에 의해 수집된 정박 선박의 선수방위각과 위치데이터를 활용하여 선회중심을 추정하는 알고리즘을 제시하고자 한다. 알고리즘의 유효성을 확인하기 위해, 실 환경에서 정박한 선박에 대한 실험연구를 수행하였다.