In this study, an acceleration sensor that has optical fibers to measure the inclination and acceleration of a structure through contradictory changes in two-component FBG sensors was examined. The proposed method was to ensure precise measurement through the unification of the deformation rate sensor and the angular displacement sensor. A high sensitivity three-axis accelerometer was designed and prepared using this method. To verify the accuracy of the accelerometer, the change in wavelength according to temperature and tension was tested. Then, the change in wavelength of the prepared accelerometer according to the sensor angle, and that of the sensor according to the change in ambient temperature were measured. According to the test results on the FBG-based vibration sensor that was developed using a high-speed vibrator, the range in measurement was 0.7 g or more, wavelength sensitivity, 2150 pm/g or more, and the change in wavelength change, 9.5 pm/℃.
본 논문에서는 프리텐션된 고강도 콘크리트 부재에서의 전달길이를 측정하기 위해 FBG 센서가 기입된 스마트 강연선을 활용하여 실험을 수행하였다. 전달길이 측정을 위해 길이 3m, 단면 150×150mm의 고강도 콘크리트 시험체를 총 5개 제작하였으며, 프리텐션 도입 시 콘크리트 압축강도는 58MPa로 측정되었다. 실험 결과 콘크리트 표면에 부착하는 기존의 전기 저항식 게이지보다 FBG 센서로부터 보다 정밀하고 신뢰성있는 강연선의 전달길이를 계측할 수 있는 것으로 나타났다. 계측결과로부터 산정된 강연선 전달길이를 기존의 여러 모델들과 비교하였으며, 이를 통해 고강도 콘크리트 부재에서의 전달길이 산정에 대한 기존 모델들의 적용성을 분석하였다. 본 연구 내용은 향후 강연선의 부착 특성 분석 등의 관련 분야 연구 등에 유용할 것으로 기대된다.
이 연구에서는 FBG센서가 내장된 강연선을 포스트텐션 UHPC 교량(길이 11.0m, 폭 5.0m, 높이 0.6m)에 적용하고 약 1년간의 긴장력 장기모니터링 결과를 정리하였다. 그리고 초기 도입 긴장력과 차량재하시험을 통하여 콘크리트 내부 강연선의 긴장력 변화를 계측하고 계측결과에 대한 분석을 수행하였다. 연구결과, 이 연구에서 제안하는 콘크리트 내부 긴장력 측정방법이 공영 중인 교량에서 외력으로 인한 콘크리트 내부의 작은 프리스트레스 변화를 효과적으로 측정할 수 있음을 알 수 있었다. 아울러 장기 계측결과를 이용하여 응력변화에 의한 유효변형률을 정확하게 얻기 위해서는 온도보정에 사용되는 열팽창계수의 선택이 매우 중요함을 알 수 있었다.
잔교식 안벽의 수중부는 접근이 쉽지 않아서 손상확인이 어려운 곳인데, 최근들어 태풍과 지진이 빈번하게 발생하고 있어 잔교식안벽 수중부 구조물의 손상 누적으로 인한 붕괴가 우려되는 상황이다. 잔교식 안벽의 붕괴를 방지하고 체계적으로 유지관리하기 위한 방안으로 FBG 센서를 이용한 적용 방법과 안전성 평가 방법을 연구하였다. 잔교식 안벽에 파일로 사용되는 원형 강관에 대한 FBG 센서의 적용 방안을 확인하기 위해 실내실험을 실시하고, 센서를 용접하여 부착하는 방법으로 적용해야 하는 것을 확인하였다. 잔교식 안벽에 대한 구조해석을 수행하여 FBG 센서를 부착하기 위한 최적의 부착위치를 확인하였다. 고정하중에 대한 응력을 구조해석을 하여 계산하고, FBG 센서를 통해 얻은 데이터를 이용하여 활하중에 대한 응력을 계산한 다음에 두 응력을 더해서 파일에 작용하고 있는 응력을 계산하였다. 계산한 응력을 허용응력과 비교하여 파일의 안전성 평가를 수행하였다. 본 연구는 잔교식 안벽의 안전성을 실시간으로 평가하는 방안을 찾기 위한 기초 연구로 수행되었다.
There are two kinds of post-tensioning system for nuclear power plants. one is bonded-type and the other is unbonded-type post-tensioning system. It is difficult to directly evaluate the effective tensile force of tendon in the case of bonded-type. Therefor, it can be evaluated by system identification(SI) method. In order to use SI technique, it should be obtained the strain measurement results of the containment building wall. This paper is mainly focused on the stain measurement according to the internal pressure of containment building using fiber optic sensor and tried to use it as a basic data of the SI technique in the future.
An accelerometer that has optical fibers to measure the inclination and acceleration of the architectural structures was examined. This was to ensure precise measurement through the unification of the deformation rate sensor and the angular displacement sensor.
This paper presents a protection method with FBG sensor in a 7-wire steel strand for improving measurement range of the sensor. For this purpose, both polyimide tube and teflon tube are employed to protect the FBG sensor. Uniaxial tests are carried out to compare their performances with those without the protection. The comparison showed that (1) maximum measurable deformation strain of the FBG-encapsulated strand with the polyimide tube enhancement is superior to the strand without the protection, (2) and it can measure effective strain larger than 1.00% without slip around the FBG sensor while there may occur the slip in the strand with teflon tube.
Recently, many researches have been conducted to use FBG seonsors in order to measure the effective prestress force in a PSC girder. FBG sensors can be useful to investigate transfer length in prestressed concrete members since they do not have any effect on the bond mechanism between a tendon and concrete. In this research, an experimental program has been conducted to measure transfer length of tendons in high strength concrete members by using FBG sensors. The test results showed that FBG sensors gave a transfer length similar to that measured by concrete surface gauges, but they gave more stable results. This research can be useful for relevant areas such as investigation on the bond mechanism of a tendon in high strength concrete members.
A PSC girder with I-typed section is one of the most common types applied to road and rail bridges in South Korea. As public service life of PSC bridges is on increase, lots of effort has been devoted to verify safety of PSC bridges. On the safety of PSC bridges, effective prestress force is one of the most important factor. At the current time, however, indirect measurements are mostly employed to measure the effective prestress force during construction. In this study, performances of FBG and EM sensors, which can directly measure the effective prestress force, are tested and investigated. The test result can be useful to develop block-out PSC girders with FBG and EM sensors monitoring effective prestress force during service life.
In this study, long term monitoring of tensile force of pre-tensioned prestressing strand embedded in UHPC ribbed deck by means of FBG sensor encapsulated into 7-wire prestressing strand. Based on the monitoring result for two years, it was confirmed that the technique proposed in this study offers efficient and robust way of monitoring the internal prestress of pre-tensioned PSC structures.
In this study it was developed FRP rod embedding FBG sensor, and compared the performance of sensor of the new rods and the existing strain gauge by applying the reinforced concrete beam-column joint in the same location. And it was found that new FRP rod was improved the structural performance and sufficiently sensing accuracy.
The FBG sensor responses simultaneously to changes in thermal strain as well as elastic strain. Thus the total strain measured from a single FBG sensor shall be corrected to obtain the elastic strain by removing the temperature effect. This paper addresses how the temperature effect can be removed when the FBG sensor is encapsulated in a 7-wire steel strand. For this purpose, fundamental properties of the FBG sensor are identified through tests using a controlled temperature chamber. Then field measurements on a UHPC pi girder with the size of 11.0 m long, 5.0 m wide, and 0.6 m high have been conducted for about one year, and the prestressing force is estimated using the raw data from the FBG sensor and by applying temperature correction technique proposed in this study. Estimated results indicate that the proposed correction technique is executable for extracting the elastic strain from monitoring data using the FBG sensor in civil infrastructures.
본 연구에서는 불특정 분포하중에 대한 다경간 연속 보 구조물의 변형률 분포를 추정하는 기법을 제시하였다. 본 추정 기법은 해석적 방법이 아닌 계측한 변형률 데이터로부터 최소제곱법을 이용한 커브 피팅을 통해 변형률 분포를 추정하였다. 제시한 다경간 보 연속 구조물의 변형률 추정 기법은 멀티플렉싱이 가능한 FBG센서를 이용하여 다경간 연속 강재 보 정적 가력 실험을 통해 검증하였다. 실험을 통해서 분포 하중과 집중하중에 의한 변형률 분포의 추정 정확성 및 변형률 추정에 사용되는 계측점 수에 따른 추정 오차에 대한 검토를 수행하였다. 5.89 (하중 step1), 6.26% (하중 step2) 오차로 최대 변형률 지점에서의 변형률을 추정할 수 있었다. 추정을 위한 변형률 계측 센서 수를 감소시킨 경우 오차가 증가 (0.26~0.37%)하는 것 또한, 확인할 수 있었다. 회귀분석적 기법을 통해 다경간 보의 변형률 분포를추정함으로써 특정 형상의 분포 하중에 대해서만 적용이 가능한 해석적 변형률 추정 기법의 한계를 넘어 불특정 분포 하중에 대한 변형률분포 추정이 가능해졌고 추정 변형률 분포를 통해 최대변형률 발생 위치까지 확인할 수 있게 되었다.
FBG센서로 변형율을 계측하고 추정 가능한 일부 저차모드를 중첩하여 교량의 동적변위를 추정하는 알고리즘을 제안하였다. 모드별 진동형상은 단순보의 이론식에서 유도하였고, 일반화좌표는 FBG센서에서 계측한 변형율에서 유도하였다. 일반 교량의 저차모드에서 발생하는 휨 및 비틀림모드는 각 거더별 혹은 구간별로 분리하여 단순보의 이론적 휨모드로 고려함으로써 다양한 형식의 교량에 적용할 수 있도록 하였다. 알고리즘의 적용에 고려해야 할 진동모드의 개수 및 변형율 센서의 개수를 결정하는 기준은 이론적으로 제시되었다. 제안된 방법의 효용성을 다양한 형식의 교량에 대한 수치예제, 모형교량에 대한 실내실험 및 자기부상열차용 PC Box 거더교에 대한 현장실험을 통해 검증하였다. 수치예제에서는 교량 진동형상의 오차 및 변형률 측정오차가 동적변위 추정 결과에 미치는 영향을 분석하였다.
하천제방의 붕괴 요인중 구조물(배수통문) 주변 제방의 붕괴는 전체 요인의 l0% 이상을 차지하고 있으며, 특히 2002년 홍수시 낙동강에서 발생한 제방 유실 지점은 거의 배수통문 주위에서 발생하였다. 이러한 제방 파괴는 이질 재료인 통문 구조물과 제체 접합부 사이에 공극이나 공동이 형성된 후 홍수시 내부 침식으로 인해 공동이 확대되어 발생하는 파괴구조를 가지고 있다. 이러한 상황에서 하천제방의 안전관리를 위해 배수통문 주변의 공동발생 여부 혹은 공동내의
본 연구에서는 광섬유 FBG 센서를 이용, 곡률반경을 고려한 이 방향 변위(Two-Way Displacement)를 측정하여 변형각을 환산함으로써 상대좌표를 구하는 알고리즘을 정립하였으며 이를 이용하면 작은 변형에 대해서도 매우정확하게 상대변위를 구할 수 있음을 알 수 있었다. 이를 확인하기 위해 4.5m높이의 H형강에 고안된 이 방향 광섬유센서를 부착하여 횡 방향으로 외력을 가해서 발생한 변위를 수준측량과 일반적인 전자식 변위계로 동시에 측정하여 각각의 측정성능을 비교분석하였다. 그 결과, 광섬유센서의 분해능은 다른 센서시스템에 비해 월등하였으며 이차원 상대좌표의 측정이 가능함을 확인하였다.