검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 17

        2.
        2021.11 구독 인증기관 무료, 개인회원 유료
        In this paper, we propose dead pixel detection and compensation method using nonlinear estimator for infrared camera. Infrared camera has dead pixel that is abnormal output values due to complex factors such as manufacturing process, electronic parts and so on. Dead pixels are able to affect detecting a small target. So, It needs detection and Compensation process. However, after Compensation, some dead pixels are remained and detected by the human. They are soft dead pixel. The key idea of this proposed method, detecting soft dead pixels, is that design a nonlinear estimator using image data characteristics. This propose is able to not only detect soft dead pixels but also pixel Compensation that reflects infrared camera output characteristics well.
        3,000원
        3.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Using the InfraRed Camera (IRC) on board the infrared astronomical satellite AKARI we study the 3.3 μm polycyclic aromatic hydrocarbon (PAH) feature and its connection to active galactic nucleus (AGN) properties for a sample of 54 hard X-ray selected bright AGN, including both Seyfert 1 and Seyfert 2 type objects. The sample is selected from the 9-month Swift/BAT survey in the 14-195 keV band and all of the sources have known neutral hydrogen column densities (NH). The 3.3 μm PAH luminosity (L3:3μm) is used as a proxy for star-formation (SF) activity and hard X-ray luminosity (L14-195keV) as an indicator of the AGN power. We explore for possible di erence of SF activity between type 1 (un-absorbed) and type 2 (absorbed) AGN. We use several statistical analyses taking the upper-limits of the PAH lines into account utilizing survival analysis methods. The results of our log(L14-195keV) versus log(L3:3μm) regression shows a positive correlation and the slope for the type 1/unobscured AGN is steeper than that of type 2/obscured AGN at a 3σ level. Also our analysis shows that the circum-nuclear SF is more enhanced in type 2/absorbed AGN than type 1/un-absorbed AGN for low L14-195keV luminosity/low Eddington ratio AGN, while there is no significant dependence of SF activity on the AGN type in the high L14-195keV luminosities/Eddington ratios.
        3,000원
        4.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        We conducted an unbiased near- to mid-infrared imaging and spectroscopic survey of the Large Magellanic Cloud (LMC) as a part of the AKARI Mission Program \Large-area Survey of the LMC" (LSLMC, PI: T. Onaka). An area of about 10 square degrees of the LMC was observed by ve photometric bands (3.2, 7, 11, 15, and 24 m) and a low-resolution slitless prism (2 { 5 m, R 20) equipped with AKARI/IRC. We constructed and publicly released photometric and spectroscopic catalogues of point sources in the LMC based on the survey data. The catalogues provide a large number of near-infrared spectral data, coupled with complementary broadband photometric data. Combined use of the present AKARI LSLMC catalogues with other infrared point source catalogues of the LMC possesses scienti c potential that can be applied to various astronomical studies.
        3,000원
        6.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : The objective of this study is to propose a quality control and quality assurance method for use during asphalt pavement construction using non-destructive methods, such as ground penetrating radar (GPR) and an infrared (IR) camera. METHODS: A 1.0 GHz air-coupled GPR system was used to measure the thickness and in situ density of asphalt concrete overlay during the placement and compaction of the asphalt layer in two test construction sections. The in situ density of the asphalt layer was estimated based on the dielectric constant of the asphalt concrete, which was measured as the ratio of the amplitude of the surface reflection of the asphalt mat to that of a metal plate. In addition, an IR camera was used to monitor the surface temperature of the asphalt mat to ensure its uniformity, for both conventional asphalt concrete and fiber-reinforced asphalt (FRA) concrete. RESULTS: From the GPR test, the measured in situ air void of the asphalt concrete overlay gradually decreased from 12.6% at placement to 8.1% after five roller passes for conventional asphalt concrete, and from 10.7% to 5.9% for the FRA concrete. The thickness of the asphalt concrete overlay was reduced from 7.0 cm to 6.0 cm for the conventional material, and from 9.2 cm to 6.4 cm for the FRA concrete. From the IR camera measurements, the temperature differences in the asphalt mat ranged from 10℃ to 30 ℃ in the two test sections. CONCLUSIONS: During asphalt concrete construction, GPR and IR tests can be applicable for monitoring the changes in in situ density, thickness, and temperature differences of the overlay, which are the most important factors for quality control. For easier and more reliable quality control of asphalt overlay construction, it is better to use the thickness measurement from the GPR.
        4,000원
        7.
        2015.06 구독 인증기관·개인회원 무료
        Clothing comfort indicates the comfortableness of the in varying environmental situations while wearing specific clothing. Various factors affect clothing comfort such as skin moisture perception and heat transmission characteristics via clothing; however, cool and warm touch are the most important factors (Kwon, Yi, & Sung,1999; Hong & Kim, 2007; Manshahia & Das, 2014). The thermal comfort of clothing is perceived through sensory receptors on the skin surface and is highly related to a cool and warm touch. An infrared thermography camera detects infrared-ray-form energy, a type of electromagnetic wave radiated from the subject's surface that assesses the intensity of radiant heat. The changing intensity then presents a real-time infrared thermal distribution using various colors. The advantages of an infrared thermography camera are the ability to use a non-contacting method to measure temperature distribution and analyze temperatures. Therefore, an infrared thermography camera is widely used in material characteristic assessment, boiler heat distribution analysis, process control, and building insulation assessments that indicate system deficiencies. This technique has also recently been used in human-body-related temperature measurements with potential for application to medical fields that include breast cancer examinations, joint muscle disorders, and body reactions under specific conditions. The most significant advantage of infrared thermography cameras to evaluate heat conductivity according to wearing conditions are its inexpensive price, ease-of-use and visual representation of surface heat dispersion on clothing that maintains body temperature and helps dissipate sweat(B. Lee, Hong, & Y. Lee, 2010; Lee, K. Hong, & S. A. Hong, 2007). This technique is also used in a quantitative analysis of thermal sensation when wearing clothes (Choi & Lee, 2008). This study helps develop a method to evaluate the warm feeling of fabrics using an infrared thermal image of a small test specimen. An infrared thermal image helped develop5 types of fabrics for heat storage fabric; consequently, the average temperature difference of the human palm when the fabric is on or off was used for the scale of the fabrics’ warm feeling. The relationshipbetween this average temperature difference on the palm surface Qmax, and warmth keep-ability rate was examined. Fabric had a significant average temperature difference in the infrared thermal image with alow Qmax value and was evaluated with high values in the warmth keep-ability rate. Infrared thermography camera was shown to be effective in the fabric's warm feeling evaluation.
        9.
        1996.12 KCI 등재 SCOPUS 구독 인증기관·개인회원 무료
        We have constructed a near-infrared imaging camera which is attached to the prime focus of 105cm Schmidt telescope at Kiso Observatory. The camera is equipped with a 1040×1040 PtSi CSD array developed by Mitsubishi Electric Co. The combination of Kiso Schmidt and the array gives a wide field of view of 18.4'×18.4' with a reasonable spatial resolution of 1.06' /pixel. The system performances of the camera have been evaluated through laboratory and observational tests. Low noise, good cosmetics(no defect pixels), and good stability of the camera system show an excellent performance for astronomical use.
        10.
        1996.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        We have built a near-infrared imaging camera with a PtSi array detector manufactured by the Mitsubishi Company. The PtSi detector is sensitive in the wavelength range 1 to 5μm 5μm . Quantum efficiency of PtSi is much lower than that of InSb and HgCdTe types. However, the PtSi array has advantages over the latter ones: (i)The read-out noise is very low; (ii)the characteristics of the array elements arc uniform and stable; (iii)it is not difficult to make a large PtSi array; and (iv) consequently the price is affordably low. The array used consists of 512×512 512×512 pixels and its size is 10.2mm×13.3mm 10.2mm×13.3mm . The filter wheel of the camera is equipped with J, H, K filters, and an aluminum plate for measuring the dark noise. The dewar is cooled with liquid nitrogen. We have adopted a method of installing the clock pattern and the observing softwares in the RAM, which Gill he easily used for other systems. We have developed a software with a pull-down menu for operating the camera and data acquisition. The camera has been tested by observing δ δ Orionis.
        6,400원
        11.
        2017.09 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 표면영상유속계의 한계점으로 지적되어 온 야간이나 안개시 적용 문제를 해결하기 위해, 원적외선 카메라를 이용한 표면영상유 속계의 적용성을 검토하였다. 이를 위해 각 조건에 대한 원적외선 카메라의 측정 정확도 평가 실험을 진행하였다. 정확도 평가는 기존에 검증이 된 주간 조건의 일반카메라를 이용한 표면영상유속계 측정 결과에 대한 상대 오차를 산정하여 평가하였다. 결과적으로 원적외선 카메라를 이용한 표면영상유속계의 야간 측정 상대 오차는 최대 4.3%, 평균 1% 내외로 매우 낮게 나타나 정확도가 높음을 확인하였고, 안개 조건 또한 최대 5.2%, 평균 2% 내외로 매우 높은 정확도를 보였다. 이에 따라 일반 카메라로 수면 흐름을 가시화할 수 없던 비가시 환경에서 원적외선 카메라를 이용하는 경우 높은 정확도로 측정이 가능할 것으로 판단된다.
        12.
        2017.05 서비스 종료(열람 제한)
        현재 정부에서는 폐자원 에너지의 회수・사용을 촉진하기 위해 정책적인 움직임을 보이고 있다. 폐기물 소각시설의 소각열에너지 회수・사용률 산정방법이 2015년에 확정되었고, 이를 반영한 자원순환기본법이 2018년 1월 1일부터 시행될 계획이다. 이에 따라, 국내 폐기물 소각시설의 에너지 회수・사용률을 증가시키기 위해 열에너지 회수를 통한 전기나 열원 생산의 효율을 측정하고 평가하는 것이 필요하다. 폐기물 소각시설 공정에서의 방열손실은 열에너지 회수의 효율을 저하시키는 원인 중 한가지이다. 이를 평가하기 위하여 소각시설의 벽면온도를 측정하여야 하며, 현재의 소각시설 벽면 온도 측정 방법은 환경부 고시 ‘폐기물 처리시설의 세부검사방법에 관한 규정’의 별표1 ‘폐기물 소각시설의 세부 검사방법’에 따른 지점측정 방식이다. 하지만 지점측정 방식의 온도 측정은 접촉식 온도계를 이용한 측정법으로, 대상의 접촉 지점에 따라 온도가 다르게 측정될 수 있으며 대상 시설의 평균 표면온도를 정확하게 측정하는 것에 한계를 가진다. 적외선 열화상 카메라는 대상의 넓은 면적을 동시에 촬영하여 온도를 측정하는 방식으로, 시설의 평균 표면온도를 비교적 정확하게 측정할 수 있다. 따라서 본 연구에서는 실제 가동 중인 폐기물 소각시설의 벽면 온도를 비접촉 온도 측정 방식의 적외선 열화상 카메라를 이용하여 측정하고, 기존에 수행되었던 연구를 통해 정립된 방열손실 산정식을 이용하여 방열손실을 계산하였다. 또한 폐기물의 소각 온도, 소각 용량, 소각로 표면적 크기 등 여러 가지 요인에 의한 방열손실을 고려하기 위하여 소각시설의 입열과 출열 항목을 측정하여 투입된 에너지 대비 손실량인 방열손실률을 산정하여 평가하였다.
        13.
        2017.03 KCI 등재 서비스 종료(열람 제한)
        Recently, domestic waste policy has focused on resource circulation. In accordance with Article 3, Paragraph 2 of the “Enforcement Rules of Wastes Control Act”, which is targeted at waste incineration facilities, we established and announced methods for calculating the recovery and utilization rates of incineration-sourced heat in 2015. The lower heating value is important to energy recovery and utilization rate calculations. Hence, the lower heating values of the waste incineration facilities were estimated using the thermal method from KS B 6205. Heat loss decreases the heat recovery efficiency, and should be measured and evaluated. The surface temperatures of the incinerator and boiler are required to determine heat loss. Presently, the contact point temperature method is used to measure the surface temperature. It is difficult to apply this method to the average surface temperature of an incineration facility. In this study, 20 Korean waste incineration facilities were selected for heat loss estimates based on waste incineration temperature, incinerator type, and incineration capacity. Infrared thermal cameras were used to measure the surface temperatures of the waste incineration facilities.
        14.
        2016.11 서비스 종료(열람 제한)
        ‘전국 폐기물 발생 및 처리현황’(환경부, 2014)에 따르면, 국내의 전국 폐기물 총 발생량은 매년 증가하는 추세이다. 건설 폐기물을 포함한 ‘14년도 총 폐기물 발생량은 388,486톤/일에 달하며, 지정폐기물을 포함하면 폐기물 발생량은 더 증가한다. 이렇게 발생한 폐기물은 매립, 소각, 재활용, 해역배출로 처리되었다. 하지만 국내의 육상 폐기물 해역배출은 런던협약에 ‘16년부터는 전면 금지되었으며, 매립과 재활용을 통한 폐기물의 처리는 한계가 있다. 지속적으로 발생량이 증가하는 폐기물의 처리와 지정폐기물, 재활용 금지 및 제한대상 폐기물을 처리하기 위하여 폐기물의 소각처리가 필수적으로 요구된다. 국내에서는 정책적으로 폐기물 소각시설의 폐자원에너지 회수와 사용에 대해 집중하고 있으며, 2015년에 폐기물 소각시설의 소각열에너지 회수・사용률 산정방법을 확정하여 2018년 1월 1일부터 자원순환기본법을 통해 시행할 것을 예고하였다. 사업장폐기물 소각시설의 소각열에너지 회수・사용률 산정방법에 따르면 열정산법을 이용해 입열과 출열을 산출하여 소각시설의 효율을 계산한다. 소각로의 방열손실은 에너지의 회수 효율을 낮추는 출열 항목 중 한가지로 각 시설마다 측정하여 평가되어야 한다. 현재 방열손실 평가를 위한 소각로의 벽면 온도 측정은 지점측정법을 이용하여 실측되고 있다. 하지만 접촉식 온도 측정은 대상의 접촉 지점마다 온도가 다르게 측정 될 수 있으므로 대상 시설의 평균 표면온도를 정확하게 측정하는 것이 어렵다. 비접촉 방식으로 온도를 측정하는 적외선 열화상 카메라는 넓은 면적의 온도를 동시에 측정 가능하며 대상 시설의 평균 온도를 비교적 정확하게 측정 할 수 있다. 따라서 본 연구에서는 폐기물 소각시설의 출열 항목 중 방열손실의 측정 및 평가를 위해 적외선 열화상 카메라를 이용하였으며, 소각로 표면 온도 측정방법과 소각시설의 방열손실 산정 방법을 정립하였다.
        15.
        2015.08 KCI 등재 서비스 종료(열람 제한)
        홍수시 하천의 유속 측정을 위한 표면영상유속계의 가장 기본이 되는 단계는 질 좋은 영상을 획득하는 것이다. 하지만 영상 획득에 있어 빛이 없는 야간에 발생하는 홍수 흐름을 촬영하는 것은 매우 어렵다. 이에 본 연구에서는 표면영상 유속계의 야간 영상 획득 장치로 원적외선 카메라를 이용하는 방안을 검토하였다. 원적외선 카메라는 별도의 조명을 필요로 하지 않으므로, 주야간 모두 영상을 획득할 수 있는 장점이 있다. 또한 안개나 연기의 영향을 받지 않아서 고정식 표면영상유속계를 구성하는 좋은 대안이 될 수 있다. 원적외선 영상을 이용한 유속 산정의 결과를 비교하기 위해, 보통의 가시광 카메라와 근적외선 카메라를 이용한 동시 촬영을 수행하여 영상을 획득하였고, 시공간 영상분석 방법을 이용하여 분석하였다. 그 결과 소형 프로펠러 유속계로 측정한 유속 자료와 비교하여 원적외선의 주간 영상을 이용할 경우 최소 -9%에서 최대 -19%의 차이를 나타냈고, 야간 영상을 이용할 경우 최소 -10%에서 최대 -23%의 차이를 나타냈다. 또한 일반캠코더의 주간 영상을 이용한 경우와 비교하여 최대 10% 이내의 차이를 보였기 때문에 주야간 유속 측정에 원적외선 카메라의 적용이 어느 정도 가능한 것을 확인하였다. 다만 주간 영상에 비해 야간 영상이 약간 흐려지는 경향이 있기 때문에, 이러한 영상을 적절히 분석하기 위한 지속적인 연구가 필요할 것으로 생각한다.
        16.
        2009.11 KCI 등재 서비스 종료(열람 제한)
        FastSLAM is a factored solution to SLAM problem using a Rao-Blackwellized particle filter. In this paper, we propose a practical FastSLAM implementation method using an infrared camera for indoor environments. The infrared camera is equipped on a Pioneer3 robot and looks upward direction to the ceiling which has infrared tags with the same height. The infrared tags are detected with the infrared camera as measurements, and the Nearest Neighbor method is used to solve the unknown data association problem. The global map is successfully built and the robot pose is predicted in real time by the FastSLAM2.0 algorithm. The experiment result shows the accuracy and robustness of the proposed method in practical indoor environment.