검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 9

        1.
        2024.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The operating parameters considered in this study include evaporating and condensing temperature, degree of subcooling and degree of superheating. in R744-R717 cascade refrigeration system and R744 two-stage compression refrigeration system with the range of low temperature -50℃∼-30℃. The coefficient of performance(COP) of R744-R717 cascade refrigeration system is about 16∼20% greater than that of R744 two-stage compression refrigeration system in the range of evaporation temperature of -50℃∼-30℃. R744 two-stage compression refrigeration system is unstable because its coefficient of performance changes significantly depending on the evaporating temperature and total compression work, and compression efficiency decreases. In this case, not efficient for long-term use. Whereas R744-R717 R744-R717 is a cascade refrigeration system using eco-friendly refrigerants. And this system is a high-efficiency refrigeration system that performs well even under various operating conditions. This is why it can be configured by selecting a refrigerant suitable for the high temperature side and the low temperature side.
        4,000원
        2.
        2022.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In the present study, the experimental study was conducted using a multi-calorie meter, to investigate the cooling performance and cycle operation changes of the multi-heat pump (3 indoor units) for the low outside temperature in summer. The test temperature condition was the low cooling temperature, and the normal performance and dynamic behavior of 3 rooms, 2 rooms, and 1 room were measured to understand the operating characteristics of seven 7 indoor unit combinations. As a result of the experiment, the cooling capacity and COP of the multi-heat pump at low cooling temperature were about 10% and 6% higher than those of the cooling standard temperature. In addition, the dynamic behavior of the indoor units of 3 and 2 rooms was observed differently due to the load difference according to the indoor unit combinations and the non-uniformity of the refrigerant amount. And, when starting the heat pump, the compressor had a maximum peak value and stabilized by repeating the decrease and increase for each indoor unit combination.
        4,000원
        3.
        2021.11 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        The precipitation effect of Al-6%Si-0.4%Mg-0.9%Cu-(Ti) alloy (in wt.%) after various heat treatments was studied using a laser flash device (LFA) and differential scanning calorimetry (DSC). Solid solution treatment was performed at 535 oC for 6 h, followed by water cooling, and samples were artificially aged in air at 180 oC and 220 oC for 5 h. The titanium-free alloy Al-6%Si-0.4%Mg-0.9%Cu showed higher thermal diffusivity than did the Al-6%Si-0.4%Mg-0.9%Cu-0.2%Ti alloy over the entire temperature range. In the temperature ranges below 200 oC and above 300 oC, the value of thermal diffusivity decreased with increasing temperature. As the sample temperature increased between 200 oC and 400 oC, phase precipitation occurred. From the results of DSC analysis, the temperature dependence of the change in thermal diffusivity in the temperature range between 200 oC and 400 oC was strongly influenced by the precipitation of θ'-Al2Cu, β'-Mg2Si, and Si phases. The most important factor in the temperature dependence of thermal diffusivity was Si precipitation.
        4,000원
        5.
        2018.05 구독 인증기관·개인회원 무료
        Tunnel is the main infrastructure in transportation system especially in Gangwon province which has 90% of its area covered by mountains. Responding to the needs for evaluating the tunnel damage in this region, the temperature inside 10 tunnels, one-way and two-way, were measured in winter by using temperature sensors. The temperatures along the length of tunnel, from the entrance until the exit, were obtained from sensors placed at 2 meters above the road. The measurement results showed the distribution of the temperature along the length of the tunnels since November 2016 until March 2017. The data showed that among all the one-way tunnels, the variation of the temperature at all positions along the length of the tunnels have almost the same gradient of temperature of all months observed. There were no significant changes between the temperatures at those points along the tunnel; whereas the changes at the entrances and the exits of the tunnels were remarkable. It was also noticed that there was the different trend of temperature variation between the one-way and two-way tunnels.
        6.
        2014.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A series of high capacity soft carbons with different phosphorus contents were successfully prepared by carbonizing petroleum cokes treated with hypophosphorous acid at 900˚C. The effect of phosphorus content on the electrochemical performance of the soft carbons was extensively investigated. The P-doped soft carbons exhibited greatly enhanced discharge capacities and outstanding rate capabilities with increasing phosphorus content. In addition, the influence of temperature on the electrochemical behaviors of the soft carbons was investigated in a wide temperature range of 25˚C to 50˚C. Surprisingly, the electrochemical properties of the pristine and P-doped soft carbons were highly sensitive to the operating temperature, unlike conventional graphite. The pristine and P-doped soft carbons exhibited significantly high discharge capacities of 470 and 522 mAh/g, respectively, at a high temperature of 50˚C.
        4,000원
        7.
        2013.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A three dimensional numerical analysis was performed to study the PEMFC performance characteristics. Operating pressure and operating temperature were selected as simulation parameters. Operating pressure was varied as 1, 2, 3, 4, and 5 atm. Operating temperature was varied as 323, 333, 343, 353, and 363 K. For a constant cell voltage condition, the maximum current density was obtained at operating pressure of 5 atm and operating temperature of 323 K. As operating pressure increases, current density increases because concentration of reactant gases increases. As operating temperature increases, current density decreases because concentration of reactant gases decreases due to high overpotential condition for the considered PEMFC.
        4,000원
        9.
        1996.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper described on relation between the catches of tuna and the distribution of water temperature of eastern fishing ground of Tropical region in the Pacific Ocean. The data of catches and water temperature used in this paper were based log book which # 27 CHENG RONG(Gross tonnage : 399 ton) had been worked eastern fishing ground(Lat : 09˚N- 14˚S, Long : 115˚- 149˚W)from January to October, 1991. The obtained result are as follows : 1. On the relation between the catches and the geographical distribution, bigeye tuna was higher catches at Lat 4˚- 9˚N, Long 135˚- 139˚W area in the equatorial counter current region where surface water temperature was range of 27.5℃ to 27.9℃, yellowfin tuna was higher catches at Lat 4˚- 9˚S, Long 145˚- 149˚W in the south equatorial current region where surface water temperature was range of 28.0℃ to 28.4℃ and albacore tuna was higher catches at Lat 10˚- 14˚S, Long 120˚- 124˚W area in the south equatorial current region where surface temperature was range of 26.5℃ to 26.9℃ 2. On the relation between catches and distribution of vertical water temperature, bigeye tuna was higher catches at the water temperature of 10℃ to 12℃ on depth layer between 300m and 360m, yellowfin tuna was higher catches at the water temperature of 15℃ to 19℃ on depth layer between 180m and 280m and albacore tuna was higher catches at the water temperature of 12℃ to 14℃ on depth layer between 280m and 310m. Above the result, it seemed that bigeye tuna distributed deeper layer than yellowfin and albacore tuna.
        4,000원