검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 131

        81.
        1999.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The objective of this study was to produce calves by transfer of embryos derived from slaughter house(SHD) and ultrasound-guided ovum pick-up (OPU). At 60 hrs after injection of 400 mg FSH dissolved in 25% polyvinylpyrrolidone(PVP) by single dose, ultrasound-guided follicular oocyte aspiration was ferformed. Day-7 and day-8 blastocysts produced by in vitro maturation (IVM), fertilization (IVF) and culture(IVC) of the oocytes derived from SHD and OPU were nonsurgically transferred into recipients. The results obtained were as follows. The cleavage rate and the development rate to blastocysts were not significantly (P<0.05) different between the oocytes obtained by SHD (72.9% vs. 34.1%) and OPU (75.9% vs. 38.4%). The oocyte recovery rate from the number of follicles by ultrasound-guided aspiration were not significantly (P<0.05) different between Holstein (61.7%) and Hanwoo (60.1%), but the rate of oocytes useful for IVF was significantly (P<0.05) higher in Hanwoo (69.3%) than Holstein (59.6%). The cleavage rate and the development rate to blastocysts was not significantly (P<0.05) different between Holstein (74.9% vs. 39.2%) and recipients on day 8 of estrus cycle resulted in 13 pregnancies (34.2%). One of them was sacrificed during gestation period due to mastitis and another was aborted spontaneous. The resulting 14 calves were morphologically normal at birth. Seventy eight fresh OPU-IVF embryos were transferred into 21 recipients on day 8 of estrus cycles, resulting in pregnancy of 12 recipients (41.4%). Two of them were sacrificed during gestation period due to mastitis and the other two were aborted. Nevertheless, the 11 OPU-calves have been born normally.
        4,000원
        82.
        1998.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Noninvasive low intensity ultrasound has been shown to be an effective means of accelerating bone fracture repair in both animal and clinical studies. The effects of ultrasound stimulation on bone repair after fibular osteotomy were assessed in a rabbit fibular fracture model. Bilateral closed fibular fractures were made in skeletally mature male White Japanese rabbits. In this study, 24 subjects were randomly divided into 2 groups: experimental group 1 (n=12), and experimental group 2 (n=12). Experimental group 1 received 0.875 MHz continuous ultrasound and Experimental group 2 was treated with 3 MHz continuous u1trasound. The ultrasound intensity was 50 and treatment time was 10 minutes for every session in both groups. In each rabbit, one fibula served as a control and the other was subjected to ultrasound treatment 5 times per week for 3 weeks. After 3 weeks, rabbits were sacrificed and the ratios of the area between the trabeculae and bone marrow of the fibulae were calculated. At the end of the experimental period, 14 of the 24 rabbits were excluded due to complications from surgery or inadequate fracture status for this study. There was no statistically significant difference in the trabeculae area between experimental leg and control leg in experimental group 1 and experimental group 2 (p>0.05). And there was also no statistic-statistically significant difference between experimental group 1 and experimental group 2 according to ultrasound treatment frequencies, 0.875 MHz and 3 MHz (p>0.05). These data suggest that in Japanese white rabbits, low intensity ultrasound stimulation does not facilitate fracture repair nor is there any difference in fracture repair results between ultrasound frequencies, 0.875 MHz and 3 MHz.
        4,000원
        83.
        1998.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The present study was carried out for the comparative study on the collection of bovine follicular oocytes by ultrasound-guided ovum pick-up(OPU) and slaughterhouse-derived (SHD) ovary aspiration and in vitro production of bovine embryos with the follicular oncytes in Korean native cows. Bovine follicular nocytes were observed with a 6.5 MHz convex-array ultrasound transducer designed for intravaginal use and the oocytes were collected with the aspiration equipment attached to the ultrasonograph. Bovine ovaries were collected and transported in phosphate buffered saline from the local slaughterhouse, the follicular oocytes were collected by the aspiration method. The collected follicular oocytes in good quality were matured, fertilized and cultured in the media. The total number of the visible follicles and the recovery rate of follicular oocytes were increased in ultrasonography following follicle stimulating hormone(FSH) treatment in Korean native cows. The mean recovery rate of oocytes was 66.2, 52.8 and 41.7% in the FSH-OPU, non-treatment-OPU and SHD ovaries, respectively. The mean number of recorved oocytes per cow were not significantly(P<0.05) different between the FSH-OPU(14.011.54) and SHD(17.1i6.21) groups, but the numbers in both groups were significantly(P<0.05) higher than the number in the non-treatment-OPU(3.71.57) group. The mean number of usable nocytes in Grade T /11 per ovary was 6.3, 4.8 and 1.3 in the cows of the SHD, FSH-OPU and non-treatment-OPU groups, respectively. The in vitro developmental rate to the blastocyst was not significantly different between the oocytes obtained via OPU(37.1%) and SHD(29.3%). Therefore, the ultrasound-guided OPU technique can be applied to the production of excellent embryos from the high-quality cows, and for the large scale production of in vitro bovine oocytes and embryos, the SHD ovary aspiration method is valuable.
        4,000원
        84.
        1998.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A combined technology of transvaginal ovum pick-up(OPU) system with in vitro-oocyte manipulation technique can be used for improving reproductive efficiency in the cattle. The objective of this study was to establish a newly-conceived breeding program using OPU in the pregnant cows. The OPU trial was performed in pregnant cows every 10 days from 40 through 90 days of artificial insemination (Al), and number of follicles in ovary, number of retrieved oocytes and embryo development following in vitro-fertilization, were evaluated. Reduced number of follicles in the ovaries of pregnant cows was firstly detected from 70 days after A' and a significant (P<0.05) decrease in the follicle number (5.4 follicles /donor) was found at 90 days than at 40, 50, 60 and 80 days after Al (8.0~9.2). A similar pattern was also observed in the number of oocytes retrieved by OPU apparatus during experimental period. When retrieved oocytes were matured and inseminated in vitro with frozen bull semen, development of the oocytes to the blastocyst stage was not significantly affected by the retrieval time. Four embryos (morula or blastocyst stage) derived from oocytes retrieved from pregnant cows were nonsurgically transferred to four recipient cows on day 7 of estrus cycle. For the first time in Korea, three of four transferred embryos developed to live calves with normal physiological parameters. In conclusion, an effective breeding program employing pregnant cow can be developed by use of OPU trial and in vitro culture techniques of oocytes ; OPU system could be repeated in pregnant cows with no risk of abortion and viable offsprings were borne after transfer to the recipients.
        4,000원
        86.
        1997.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The object of this study were twofold, namely, to study on (1) effect of using ultrasound therapy for curing warts (2) any relation between a cure for warts and onset of warts, as well as subject age. Our subjects, composed of 22 people from age 12 to 49, were assigned to two groups, experimental group and control group. We experimented for 8 session on 12 people in the experimental group by using ultrasound therapy to observe any morphological change in the warts or disappearance of a pain. However, we did not cure warts in the other group, control group. The result of the study are as follows. (1) Ultrasound therapy has an effect on curing warts. (2) Neither condition, onset of warts or subject age, had no influence on a cure for warts.
        4,000원
        87.
        1997.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This experiment was carried out to develop the anesthetic methods for ultrasonography and a new simplified disposable needle guidance device for ovum pick-up(OPU) in cows. Three different anesthetic methods were applied as. 1) epidural analgesia only with 2% lidocaine(20~30 ml), 2) epidural analgesia with 2% under general sedation with xylazine, 3) epidural analgesia with 2% lidocaine under general sedation with detomidine. We evaluated the anesthetic effects with items such as relaxation of anal sphincter, tail movement and rectal wall, retractability of both ovaries, additional anesthesia and possibility of OPU. Through this experiment, the above three anesthetic methods were applicable to OPU, but the epidural anlagesia under general sedation with detomldine was most effective for OPU. We developed a new disposable needle guidance device with stainless steel tube. With this, disposable needles can be easily attatchable to any other intravaginal probes. And also, it was found to he practical, economic and effective for OPU with the recovery rate of 51.2%.
        4,000원
        88.
        1997.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was carried out to compare the actual size(length and height) of ovaries, follicles and corpora lutea of Korean native cow with those on sonograms. We used 3 different probes(3.5 MHz abdominal probe, 6.5 MHz transvaginal probe and 5.0 MHz transrectal probe) and a calipher for measurements of ovaries, follicles and corpora lutea on sonograms and actual size. Under water immersion, 157 ovaries were scanned with 3 probes and measured in actual size and compared each other. The average height and width of ovaries of Korean native cows were 17.403.99 and 34.236.02mm, respectively. In comparison of height, length of ovaries and preovulation follicles, we found that image with a transvaginal probe was nearly the same as the actual size(p<0.01), but with an abdominal probe the image was appeared larger than the actual size. In measurement(diameter) of preovulation follicles the transvaginal probe was proven to be more accurate to the actual size than other probes and in corpus luteum measurement all probes were accurate. In the comparison of number of follicles by different size ranges, there was no statistical difference in the count of follicles over 10 mm in diameter between the transvaginal probe and naked eyes.
        4,000원
        89.
        1997.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The present study was carried out to evaluate the effect of superovulation treatments on ovarian responses, oocyte recovery rates and grades of collected oocytes using an ultrasound-guided transvaginal approach in Korean native cows. Superovulation in cows was induced with two different regimenes: 1) FSH-decreasing dose(n=8): the cows were received twice per day for three days of the total dose of 400 mg of FSH-p, 2) FSH-single dose(n=9): the cows were administrated a single dose of 400 mg of FSH-p in 25% PVP. The Observation of visible follicles and collection of oocytes were performed 12 hours following the last FSH in FSH-decreasing dose group and 48 hours after the FSH-single dose injection. All visible follicles larger than 6 mm were punctured and aspirated with a 6.5 MHz convex-array ultrasound transducer designed for intravaginal use. The mean number of visible follicles(> 6 mm) was significantly(P<0.05) higher in the FSH-decreasing dose treatment (22.811.9) and FSH-single dose treatment (20.612.0) groups than the non-treatment group(7.08). The mean recovery rate of oocytes was not significantly(P<0.05) different between the treatment and control groups, but the mean number of collected oocytes was significantly(P<0.05) higher in the FSH-decreasing dose treatment( 12.611.5) and FSH-single dose treatment (11.813.6) groups than the non-treatment group(3.70.5). In conclusion, the FSH-single dose treatment at superovulation in cows for ultrasound-guided aspiration might increase the number of aspiratable follicles and the recovery rate of follicular oocytes as the FSH-decreasing dose treatment.
        4,000원
        91.
        1997.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The use of therapeutic ultrasound(US) in humans with malignant neoplasms has been contraindicated in physical therapy practice. Some studies have shown that results after application of US differ according to tumor type and penetration depth. The purposes of this study were to determine the effects of US on melanoma in mice and to determine treatment dosage. Twenty-four female C57BL/6 mice, age 8 weeks. The right flank of all mice was shaved, and a 0.1 ml suspension of cells was injected subcutaneously into the animals' right flank. In this study, 24 subjects were randomly divided into three groups: experimental group 1(n=8), experimental group 2(n=8), control group(n=8). In the experimental group 1, animals received continuous 3 MHZ US treatment, administered at for five minutes. In experimental group 2, animals received continuous 3 MHz US treatment, administered at for 5 minutes. The control group received the same handling as other experimental groups, including rodent chow, water, US gel application but US head pressure without the power turned on. After 10 days treatment, all mice were killed with a potassium solution. Tumors were excised and weighed on an electrical balance and fixed in a 10% neutral buffered formalin solution. Tumor weights were smaller in experimental group 2(0.3838 g) than in the control group(0.6275 g). Tumor weights of the experimental group 1(0.015 g) were smaller than those of experimental group 2. Continuous therapeutic US decreased the weight of subcutaneous melanoma tumors in mice. The treatment dosage() we suggest was more effective than earlier studies on decreasing tumor size with ultrasound.
        4,000원
        92.
        1996.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The aim of this study was to evaluate the effect of recombinant bovine somatotropin (bST; Boostin-S, LG Chem) treatment with FSH (Super OV) or PMSG on superovulatory response for transvaginal ultrasound-guided oocyte retrieval (TVR) in calves. Eight Korean Native Cattle(KNC) heifer calves; 150 to 240 days old; were randomly assigned to four treatment groups: 1) FSH(75 mg); 2) FSH (75 mg) + bST(500mg) 3) PMSG(1;000 IU); 4) PMSG(1, 000 IU) + bST(500 mg). Experimental calves in group 1 (n=2) and 2(n=2) were weekly superovulated for 4 consecutive weeks with daily injection of FSH for 3days and the next day subjected to TVR session. Animals in group 3 (n=2) and 4(n=2) were weekly stimulated for 4 consecutive weeks with a single dose of 1, 000 IU PMSG. TVR was performed on 72 hours after PMSG injection. Calves in group 2 and 4 was received injection of 500 mg of bST every 10 days. At each TVR session, follicle number and size were recorded; the oocytes collected and graded according to cumulus and cytoplasm investment. Collected oocyte were determined viable oocyte according to morphological quality with granulation of oocyte and number and status of cumlulus cells. IVM and IVF were performed and assessed cleavage rate on day 3 after fertilization. A Sonovet 600(Medison, Co., Ltd) realtime ultrasound scanner with a 6.5 MHz convex transducer, fixed at the tip of 500 mm estended handle equipped with a needle guide was used in collecting oocyte. Differences between groups were analysed by chi-square test. The population of large follicle (5 nun) and aspiration rate were not significant different among the 4 groups. But, the number of small follicles (<5 mm) and aspirated oocyte in the KNC calves treated with bST were 1.3~1.6 times higher than in KNC calves treat with FSH or PMSG alone. In conclusion, the administration of bST with FSH or PMSG at superovulation for TVR in calves was increase the nurnber of small follicle which was influenced the number of aspiratable follicle.
        4,000원
        93.
        1993.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Acoustical imaging has made brilliant progress in the medical science field, and has also made much progress in the nondestructive testing and under water acoustics applications since doctor Dussik brother has studied about possibilities of making images of brain by recording variations in the intensity of ultrasonic beam from head in 1937. In this paper an acoustical image is reconstructed with the power spectra analysed by impulse ultrasound wave generated by electrodynamic transducer(EDT). The EDT generates the impulse ultrasound of 77KHz in center frequency and 120KHz in bandwidth at -20dB by 1200V exciter in this experiment. The impulse ultrasound has the dominant frequency components of 47KHz, 177KHz, 110KHz and 155KHz. The U shape object is adopted in making an acoustical image. The resulted spectral acoustical images are different from the optical view of the U shape object. However the image reconstructed from 110KHz spectrum is very similar to the original optical shape of the object. Even KHz level impulse sound of 70μsec pulse width is found to be useful in reconstructing acoustical imaging improvement.
        4,000원
        94.
        2020.02 KCI 등재 서비스 종료(열람 제한)
        본 연구의 목적은 콘크리트 재료 및 구조물의 균열 특성 평가에 활용되고 있는 확산초음파 기법의 적용 가능성을 검토하는데 있다. 이를 위한 첫 단계로 외부 환경에 따라 변화하는 콘크리트의 수분 함유량 변화를 묘사하여, 확산초음파 파라미터와 콘크리트 수분 함유량 사이의 상관관계 분석을 수행하였다. 실험실 환경에서 완전 건조된 실험체를 수중에서 포화시켜가며 콘크리트 함수율의 차이를 묘사하였으며, 콘크리트 내부에서 초음파의 산란 현상이 충분히 발생하는 500 kHz 주파수 대역대의 신호를 가진 및 분석하여 확산초음파 파라미터인 초음파 확산계수와 초음파 에너지 소산계수를 산정하였다. 콘크리트의 수분 함유량은 확산초음파 실험 시 실험체의 무게 변화를 통해 추정하였으며, 수분 함유량 증가에 따라 실험체에서 무게가 약 2.5 % 가량 증가한 것으로 나타났다. 콘크리트 실험체의 포화정도에 따라 초음파 확산계수는 지속적으로 증가하는 것으로 나타났으나, 변화율은 확산초음파 기법의 계측 오차 범위 내에 있었다. 반면에, 초음파 에너지 소산계수는 완전 포화된 콘크리트에서 완전 건조된 콘크리트 대비 약 120 % 증가하여, 수분함유량에 대해 민감한 것으로 나타났다. 따라서, 추후 확산초음파 기법을 활용하여 콘크리트 재료 및 구조물의 균열 특성 평가 시 함수율에 대한 고려가 필요할 것으로 사료된다.
        95.
        2019.11 KCI 등재 서비스 종료(열람 제한)
        초음파는 인체에 무해하다고 알려져 산부인과에서 태아의 진단 및 발육상태 확인을 위해 널리 이용되고 있다. 진단 초음파의 장시간 사용은 체온 변화를 야기할 수 있지만 초음파로 인한 임신부의 자궁온도 변화에 대한 연구가 부족한 실정이다. 이에 본 연구에서는 자체 제작한 자궁모형팬텀을 이용하여 초음파 주사 시간에 따른 온도 변화를 알아보고자 하였다. 조직등가 물질인 아크릴과 돼지 자궁을 이용하여 인체 자궁과 유사한 자궁모형팬텀을 자체 제작하였으며 초음파 장비와 4㎒ convex probe를 사용하였다. 아크릴 수조 내부, 자궁내부, 대기온도 측정을 위해 3개의 탐침형 온도계를 설치하였고 측정대상의 온도를 분단위로 6 시간, 총 361회 측정한 결과 자궁모형팬텀의 온도가 상승되었음을 확인하였다. 본 연구를 통해 초음파로 인한 인체 체온 상승의 가능성을 확인 할 수 있었고 본 연구가 초음파 열 흡수효과 연구의 기초자료로 활용 될 것이라 사료된다.
        96.
        2019.10 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 20대 초반의 남, 여를 대상으로 초음파 방식으로 측정된 골밀도와 신체조성 및 배근력의 관계에 대해 알아보았다. D대학에 재학 중인 61명의 학생에 대해 IRB 승인과 참여자 동의 후 설문조사, 초 음파방식 골밀도 및 신체조성, 배근력을 측정하였다. 골밀도는 주로 사용하는 측 종골을 측정하여 T-값을 두 그룹(T-score≥-1.0; T-score<-1.0)으로 나누었다. 생체전기 저항법을 이용하여 신체조성을 측정하였고, 배근력은 2회 측정하여 평균값을 구하였다. 모든 통계분석은 SPSS ver. 22.0 을 사용하여 실시하였다. 신체 활동 또는 체질량지수가 증가할수록 골밀도 및 신체조성의 근육량도 증가하였다. T-값이 높은 그룹이 낮은 그룹 보다 신체조성의 근육량 및 골격근량, 신체발달이 높았지만 통계학적인 유의성은 없었다(p>0.05). 배 근력에서도 T-값이 높은 그룹이 낮은 그룹 보다 높았다(101.1 vs. 92.1, p=0.308). 남, 여그룹에서 골밀도 T- 값과 신체조성의 골격근과 근육량은 보통 수준의 유의한 양의 상관성을 보였고(p<0.05), 배근력은 신체조성의 골격근과 근육량, 신체발달에서 골밀도 보다 높은 유의한 양의 상관성을 보였다(p<0.001). 여자그룹이 남자그룹 보다 골밀도 T-값과 신체조성의 골격근과 신체발달에서 높은 상관성을 보였다. 남자 그룹에서 배근력과 골밀도의 T-값과는 유의한 상관성을 보이지 않았지만(r=0.176, p=0.319), 여자 그룹에서는 보통 수준의 유의한 상관성을 보였다(r=0.591, p=0.001). 이상과 같이 초음파 방식으로 측정된 골밀도와 신체조성, 배 근력은 상호 유의한 관련성을 보였다.
        97.
        2019.04 KCI 등재 서비스 종료(열람 제한)
        본 논문은 초음파 검사 및 판독에 사용되는 CRT, LCD 모니터에서 영상검사와 판독 시 적절한 시각화에 대한 최적의 주변 조도 수준을 제안하고자 하였다. 평가자들은 4그룹 20명(Ultra-sonographer 20명(4 groups; ultra-sonographer 1~5 years 5명, ultra-sonographer 6~10 years 5명, ultra-sonographer 11~15 years 5명, ultra-sono grapher 16~20 years 5명)을 대상으로 하였으며, 문항수는 32문항이었다. 평가방법은 10, 25, 100 Lux 3가지 주변광 조도에서 초음파 soft copy 영상을 1문항 당 30초간 영상 평가하였으며, 평가 결과를 6점 척도로 1 점=Normal (Definitely no lesion), 2점=possibly not a lesion, 3점=probably not a lesion, 4점=possibly a lesion, 5 점=probably a lesion, 6점=Definitely a lesion으로 나타내었다. 본 연구에서 주변광에 따른 초음파 영상들에 대한 병변 감지에 사용되는 소프트 카피(soft copy) 영상 판독 ROC분석 결과는 10 Lux에서 높은 민감도, 특이도, 곡선하면적 결과를 나타내었다. 주변광 조도로 10 Lux를 이용한다면 초음파(ultrasound) 소프트 카피(s oft copy) 영상의 병변 탐지에 있어 최적의 효과를 얻을 수 있음을 알 수 있었다. 추후 연구 자료를 기초로 하여 초음파 영상 검사실 및 판독실의 주변광 조명밝기를 설계하면서 기초자료로 제시될 것으로 생각한다.
        98.
        2019.04 KCI 등재 서비스 종료(열람 제한)
        본 연구는 갑상샘 초음파에서 K-TIRADS 분류와 K-TIRADS 분류에 따른 Different risk group의 조합을 이용한 방법이 양성과 악성 결절의 감별진단에 유용한지를 평가하였다. 갑상샘 초음파를 시행한 210명을 대상으로 하였으며, 세침흡인세포검사 결과를 바탕으로 후향적인 분석을 하였다. 갑상샘 결절의 양성과 악성에 따른 K-TIRADS와 Different risk group의 점수체계의 차이 분석은 카이제곱 검정을 하였다. ROC 곡선 분석을 통해 악성 결절의 예측을 위한 K-TIRADS 점수와 Different risk group의 최적 cut off 값을 결정하였다. 양성과 악성 결절 군의 분류에 따른 K-TIRADS와 Different risk group의 차이검증 결과에서 각각 통계적으로 유의한 차이를 보였다(p=.001). ROC 곡선 분석에서 양성과 악성 결절의 예측을 위한 K-TIRADS에 따른 점수분류에서는 AUC 0.786, Cut-off value> 2를 나타내었으며, Different risk group에서는 AUC 0.640, Cut-off value> 2로 결정되었다(p=.001). 갑상샘 초음파에서 결절을 발견했을 때 양성과 악성 갑상샘 결절을 감별하는 데 도움을 주는 K-TIRADS에 따른 분류체계가 Different risk group에 따른 분류체계보다 갑상샘 결절의 감별진단에 도움을 줄 것으로 생각하며 K-TIRADS에 따른 분류체계를 적용하면, 불필요한 세포 검사를 줄일 수 있고, 악성 결절의 조기발견에 도움이 될 것으로 생각된다.
        99.
        2019.02 KCI 등재 서비스 종료(열람 제한)
        본 실험의 목적은 SonoVue를 이용하여 장비 간 MI 값 및 시간 변화에 따른 관계를 유추해 보고, 신호 차이를 비교 분석하는 것이다. 비교 장비 모두 MI 값 증가에 따라 초기에 강한 신호 값을 보였다. 시간의 경과에 따라 장비 간 신호 값은 RS85A의 MI 0.1의 조건의 10분경과를 제외한 모든 조건에서 신호 감소를 보였다. 장비 간 비교에서 EPI Q7, RS85A, E9순으로 높은 값이 나왔고, RS85A와 E9의 SNR과 CNR의 정량적 평가에서 모두 p-value<0.05 로 통계적으로 유의하였다. EPIQ7에서의 MI 값의 SNR을 제외한 CNR과 시간에 따른 SNR, CNR 모두 통계적으로 유의하였다. 이를 통해 조영 증강 초음파 검사에 있어 낮은 MI 값 (MI<0.5)이더라도 장비 간 신호 강도 차이가 있으므로 MI 값과 시간을 조절하여 검사하는 것이 권고된다.
        100.
        2019.02 KCI 등재 서비스 종료(열람 제한)
        본 연구는 유방 초음파 검사 시 S-detect 성능에 관한 내용을 알아보고 이에 따라 조직 검사와 비교하여 불필요한 조직 검사를 줄일 수 있는 방안을 알아보고자 하였다. 2018년 8월에서 10월까지 유방초음파 검사 를 시행한 환자 중 유방결절이 발견되어 조직 검사가 계획된 30명의 환자를 대상으로 후향적으로 분석하 였다. S-detect 방법에서의 악성 감별과 Biopsy에서의 악성감별에 유의한 차이가 있는지 알아보기 위해 Mc Nemar test 분석을 실시하였다. S-detector 방법의 분석 결과 민감도는 90.9 %, 특이도 84.21 %, 정확도 86.66 %, 양성예측도 76.92%, 음성예측도 94.11 %로 나타났다. S-detect 방법과 Biopsy 방법 간에 일치도 분석 결과 kappa 값이 0.724(p<0.05)로 높게 나타났으며, 두 방법 간에 좋은 일치도를 보였다. 유방초음파 검사 시 S-detect를 활용한 검사 방법에 있어서 유방 종괴에 악성과 양성 감별 진단에 있어서 진단적으로 가치가 있 었으며, 유방조직 검사 실시 전 적절히 활용한다면 불필요한 조직 검사를 줄일 수 있는데 도음을 줄 것이 다.
        1 2 3 4 5