검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 819

        1.
        2024.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Efforts have been extensively undertaken to tackle overheating problems in advanced electronic devices characterized by high performance and integration levels. Thermal interface materials (TIMs) play a crucial role in connecting heat sources to heat sinks, facilitating efficient heat dissipation and thermal management. On the other hand, increasing the content of TIMs for high thermal conductivity often poses challenges such as poor dispersion and undesired heat flow pathways. This study aims to enhance the through-plane heat dissipation via the magnetic alignment of a hybrid filler system consisting of exfoliated graphite (EG) and boron nitride (BN). The EG acts as a distributed scaffold in the polymer matrix, while the BN component of the hybrid offers high thermal conductivity. Moreover, the magnetic alignment technique promotes unidirectional heat transfer pathways. The hybrid exhibited an impressive thermal conductivity of 1.44 W m− 1 K− 1 at filler contents of 30 wt. %, offering improved thermal management for advanced electronic devices.
        4,000원
        2.
        2024.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In order to overcome the limitations of linear vibration energy harvesters and those using mechanical plucking, magnetic plucking vibration energy harvesters (MVEs) have garnered significant interest. This paper presents parametric studies aimed at proposing design guidelines for MVEs and compares two magnetic force models that describe interactions between two permanent magnets. A mathematical model describing the energy harvester is employed, followed by the introduction of two magnetic force models: an analytic model and an inverse square model. Subsequently, numerical simulations are conducted to investigate dynamic characteristics of MVEs, analyzing results in terms of tip displacement, voltage output, and harvested energy. Parametric studies vary the distance between magnets, the speed of the external magnet, and the beam shape. Results indicate that reducing the distance between magnets enhances energy harvesting effectiveness. An optimal velocity for the external magnet is observed, and studies on beam shape suggest greater energy harvesting when the shape favors deflection.
        4,000원
        3.
        2024.08 구독 인증기관 무료, 개인회원 유료
        This research investigates into using a highly efficient magnetic abrasive finishing (MAF) method to refine the surface of an Inconel 625 bar intended for use as a stem in a hydrogen solenoid valve. In contrast to the previous choice of STS 316 material, Inconel 625 was selected due to its superior properties. The cylindrical surface of Inconel 625 bars underwent polishing using the super-fast MAF process, employing varying rotational speeds ranging from 1000 to 25,000 RPM and a potent magnetic field of 550 mT. The study evaluated the polishing outcomes concerning abrasive type, rotational speeds, and processing duration. The results demonstrated the achievement of an exceptionally smooth surface on the Inconel 625 bar, with the surface roughness (Ra) reduced significantly, reaching 0.03 μm under optimal conditions. These conditions included employing carbon nanotube (CNT) particles of 0.04g, PCD diamond abrasive of 1g, Fe of 9g, 0.5g of light oil, and a processing time of 16 minutes at 15,000 RPM. Furthermore, Ansys analysis confirmed the mechanical integrity of the polished Inconel 625 bar, exhibiting suitable strain, equivalent stress, and safety factors. This substantiates the feasibility of employing Inconel 625 bars in hydrogen tanks, surpassing the conventional STS 316L bars.
        3,000원
        4.
        2024.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The intensive development of the petrochemical industry globally reflects the necessity of an efficient approach for oily sludge and wastewater. Hence, for the first time, the current study utilized magnetic waxy diesel sludge (MWOPS) to synthesize activated carbon coated with TiO2 particles for the removal of total petroleum hydrocarbons (TPH) and COD from oily petroleum wastewater (OPW). The photocatalyst was characterized using CHNOS, elemental analysis was performed using X-ray fluorescence spectroscopy (XRF), field emission scanning electron microscope (FESEM), high-resolution transmission electron microscope (HR-TEM), X-ray diffraction analysis (XRD), Fourier transform infrared spectrometer (FTIR), Raman, energy dispersive X-ray spectroscopy (EDX), X-ray photoelectron spectroscopy (XPS), MAP thermo-gravimetric analysis/ differential thermo-gravimetric (TGA–DTG), Brunauer–Emmett–Teller (BET), diffuse reflectance spectroscopy (DRS), and vibrating sample magnetometer (VSM). The optimization of synthesized highly porous AC/Fe3O4/TiO2 photocatalyst was conducted considering the impacts of pH, temperature, photocatalyst dosage, and UVA6W exposure time. The results demonstrated the high capacity of the MWOPS with inherent magnetic potential and desired carbon content for the removal of 91% and 93% of TPH and COD, respectively. The optimum conditions for the OPW treatment were obtained at pH 6.5, photocatalyst dosage of 250 mg, temperature of 35 °C, and UVA6W exposure time of 67.5 min. Moreover, the isotherm/kinetic modeling illustrated simultaneous physisorption and chemisorption on heterogeneous and multilayer surfaces. Notably, the adsorption efficiency of the AC/Fe3O4/TiO2 decreased by 4% after five adsorption/desorption cycles. Accordingly, the application of a well-designed pioneering photocatalyst from the MWOPS provides a cost-effective approach for industry manufacturers for oily wastewater treatment.
        5,400원
        5.
        2024.07 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        We investigated dynamic interaction between adjacent magnetic loops in the solar atmosphere, which is a process of volume shrinkage with nonuniform acceleration caused by Lorentz force. When these loops locally have different thermal and dynamic properties, a significant discrepancy between their translational motions driven by means of that force may arise, leading to the dynamic interaction. We use both numerical simulation and analytic model of magnetic piston-driven wave to evaluate how much a single event of the interaction contributes to increasing the temperature in the upper chromosphere. The model shows a possibility that a chromospheric plasma is heated by the single event to have transition region temperature, which is typically several tens of times higher than chromospheric temperature. The model also provides an insight into the formation height of the transition region.
        4,000원
        6.
        2024.06 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        The structure and magnetic properties of composite powders prepared by ball milling a mixture of Fe2O3 ‧ (0.4-1.0)Fe were investigated. Hysteresis loops and differential scanning calorimetry (DSC) curves are used to characterize the materials and to examine the effect of the solid state reaction induced by ball milling. The results showed that a solid state reaction in Fe2O3 ‧ (0.4-1.0)Fe clearly proceeds after only 1 h of ball milling. The system is characterized by a positive reaction heat of +2.23 kcal/mole. The diffraction lines related to Fe2O3 and Fe disappeared after 1 h of ball milling and, instead, diffraction lines of the intermediate phase of Fe3O4 plus FeO formed. The magnetization and coercivity of the Fe2O3 ‧ 0.8Fe powders were changed by the solid state reaction process of Fe2O3 by Fe during ball milling. The coercivity of the Fe2O3 ‧ 0.8Fe powders increased with increasing milling time and reached a maximum value of 340 Oe after 5 h of ball milling. This indicates the grain size of Fe3O4 was clearly reduced during ball milling. The magnetic properties of the annealed powders depend on the amount of magnetic Fe and Fe3O4 phases.
        4,000원
        13.
        2024.03 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        This work focuses on the fabrication of excellent magnetic structures for trapping breast cancer cells. Micromagnetic structures were patterned for trapping cancer cells by depositing 30 nm of permalloy on a silicon substrate. These structures were designed and fabricated using two fabrication techniques: electron beam lithography and laser direct writing. Two types of magnetic structures, rectangular wire and zig-zagged wire, were created on a silicon substrate. The length of each rectangular wire and each straight line of zig-zagged wire was 150 μm with a range of widths from 1 to 15 μm for rectangular and 1, 5, 10 and 15 μm for zigzag, respectively. The magnetic structures showed good responses to the applied magnetic field despite adding layers of silicon nitride and polyethylene glycol. The results showed that Si + Si3N4 + PEG exhibited the best adhesion of cells to the surface, followed by Si + Py + Si3N4 + PEG. concentration of 5-6 with permalloy indicates that this layer affected silicon nitride in the presence of Polyethylene glycolPEG.
        4,000원
        14.
        2024.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 3D 프린팅 기술과 인체공학 순설계를 이용하여 턱관절 자기공명영상 동적 턱관절 검사 보조기구를 개발하고자 하였다. 3D 프린팅 기술 재료는 3D 프린터(Sindo, 3DWOX1, Korea), 3D 모델러 프로그램(Fusion 360, autodesk, USA), PLA(polylactic Acid) 필라멘트 소재를 이용하였고, 영상 검사는 3.0T 자기공명영상 장비 (Magnetom Vida, Siemens, Germany)를 사용하였다. 개발 방법은 성인 30명(남:13명, 여:17명, 평균나이 22.9±2.0세)의 안면뼈 CT(computed tomography) 검사의 단면 영상을 역학적으로 실측하여 상/하악궁의 형상을 모델링하였다. 모델링된 파일은 FDM(fused deposition modeling) 방식으로 3D 프린팅하였다. 출력된 보조기구는 자화 감수성 인공물 실험, 동적 영상 비교, 만족도 평가로 성능을 평가하였다. 그 결과, 자화감수성 인공물 발생은 개발된 개구 보조 장비와 비교하여 모든 영상에서 유의한 차이가 없었다. 동적 비교 영상에서는 TSE 기법이 모든 평가 법에서 가장 우수한 영상 품질을 보였다. 만족도 평가에서는 피검자는 평균 4.3점, 방사선사는 평균 4.4점으로 높은 만족도를 보였다. 결론적으로 인공물 발생이 없는 환자 맞춤형 보조기구에 개구의 동적 기능이 탑재된 보조기구 를 개발하였다.
        4,200원
        15.
        2024.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 자기공명영상검사실 방사선사의 환자안전 문화 인식을 분석하고자 하였다. 수도권 자기공명영상검사 실에서 근무하는 방사선사 109명을 대상으로 일반적인 특성, 실태조사, 환자안전 문화 인식에 대해 설문 조사하였 다. 의료종사자들을 대상으로 개발된 한국형 환자안전문화 측정 도구에서 최상위 리더십을 경영진으로, 부서장이라 는 단어를 파트장으로 수정하였고 전문가 5인에게 내용 타당도를 검증받았다. 결과적으로 자기공명영상검사실에서 근무하는 방사선사의 환자안전 문화 인식 점수는 평균 3.97로 높았지만, 안전사고경험 비율이 65.1%로 높게 나타났 다. 따라서 정기적으로 이루어지고 있는 자기공명영상검사 안전교육의 효율성 제고를 위한 연구가 필요하며 본 연구 가 기초자료를 제공할 것이라 사료된다.
        4,000원
        16.
        2024.01 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        A force-free field (FFF) is determined solely by the normal components of magnetic field and current density on the entire boundary of the domain. Methods employing three components of magnetic field suffer from overspecification of boundary conditions and/or a nonzero divergence-B problem. A vector potential formulation eliminates the latter issue, but introduces difficulties in imposing the normal component of current density at the boundary. This paper proposes four different boundary treatment methods within the vector potential formulation. We conduct a comparative analysis of the vector potential FFF solvers that we have developed incorporating these methods against other FFF codes in different magnetic field representations. Although the vector potential solvers with the new boundary treatments do not outperform our poloidal-toroidal formulation code, they demonstrate comparable or superior performance compared to the optimization code in SolarSoftWare. The methods developed here are expected to be readily applied not only to force-free field computations but also to time-dependent data-driven simulations.
        4,300원
        17.
        2024.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, a low-cost and easily recyclable porous green adsorbent (magnetic porous loofah biochar, MPLB) was synthesized by modifying the almost zero-cost loofah biochar material with Fe3O4. The successful synthesis of the material was demonstrated by XRD, FTIR, SEM, VSM, and BET. In addition, the material exhibits outstanding magnetic separation performance (40.01 umg/g) allowing for rapid recovery within just 90 s. The adsorption process of phenol on MPLB was found to be spontaneous and endothermic. The experimental data fit exceptionally well with the pseudo-second-order kinetic model and Langmuir model (R2 > 0.99), indicating that the dominant adsorption mechanisms involved monolayer adsorption and chemisorption. These interactions were attributed to host–guest interaction, π–π conjugation, hydrogen bonding, and pore filling. The maximum adsorption capacity calculated using the Langmuir model at 298 K is 39.4 mg/g. Importantly, even after undergoing seven cycles of recycling, MPLB retained 78% of its initial adsorption capacity. In simulated experiments employing MPLB for phenol removal in actual wastewater, an impressive removal rate of 96.4% was achieved. In conclusion, MPLB exhibits significant potential as an effective adsorbent for phenol removal in wastewater.
        4,000원
        18.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study investigates the enhancement of surface precision and dimensional accuracy in STS 316L oval pipes through the application of magnetic abrasive finishing. The experiment involves the modification magnetic pole shapes(A, B, C, D) and a comprehensive analysis of their impact on surface quality. Key parameters include magnetic abrasive KX#320, iron powder, aluminum oxide, light oil, a test specimen rotating at 600rpm, and periodic injection of polishing liquid, a permanent magnet Nd-Fe-B, and magnetic pole steel 1018, reciprocating distance 20mm, and a feed rate 1mm/sec over a 32minutes duration with measurements every 4minutes. The results demonstrate significant variations in surface quality based on magnetic pole shape, with specific configurations demonstrating superior precision and smoothness from the initial surface 0.32μm to 0.06μm.
        4,000원
        19.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        자기공명(magnetic resonance, MR)영상에서 주로 발생하는 Rician 노이즈는 영상의 화질을 저하하는 주요 요소 중의 하나이다. 본 연구에서는 노이즈 제거에 효율적이라고 잘 알려진 총변이(total variation, TV) 알고리즘을 모 델링하여 Rician 노이즈 레벨에 따른 파라미터를 최적화하고자 한다. 시스템은 8채널 기반의 3.0 T 장치를 활용하였 고 물 팬텀 영상을 획득하여 각각 Rician 노이즈를 0.05, 0.10, 0.15, 그리고 0.20 값을 부가하였다. TV 알고리즘 은 Rudin-Osher-Fatemi 모델을 기반으로 모델링하였고 최적화를 수행하기 위하여 반복수 파라미터를 조정하여 획득된 영상에 적용하였다. 결과적으로 Rician 노이즈 레벨을 0.05, 0.10, 0.15, 그리고 0.20을 사용하였을 때 각 각 30, 40, 80, 그리고 120 반복수를 기반으로 한 TV 노이즈 알고리즘에서 가장 우수한 신호 대 잡음비(signal to noise ratio, SNR)와 대조도 대 잡음비(contrast to noise ratio, CNR) 결괏값이 도출되었다. 또한, 최적화된 반복수를 적용한 TV 알고리즘을 사용한 MR 영상에서 기존의 위너 및 중간값 필터를 사용하였을 때 비하여 SNR과 CNR 모두 우수한 값을 획득할 수 있었다. 특히 기본적으로 획득된 MR 영상보다 최적화된 TV 알고리즘을 적용한 영상의 평균 SNR과 CNR은 각각 3.11 및 3.31배 향상됨이 증명되었다. 결론적으로, 노이즈 제거 효율이 우수한 TV 알고리즘의 최적화된 파라미터를 활용한다면 MR 영상에서의 활용 가능성이 클 것으로 기대한다.
        4,000원
        20.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        압축센스(Compressed SENSE) 기법은 검사 시간을 획기적으로 단축할 수 있으나, 시간 단축을 위한 기법적용 시 가속계수를 증가시키면 인공물의 발생이 영상에서 증가하는 문제점이 있다. 이에 인공물이 발생하지 않으면서 검사 시간을 최대한 단축할 수 있는 최적의 압축센스 가속계수를 제시하고자 하였다. 연구 방법은 인공물이 발생하지 않는 가속계수 1.0을 기준으로 0.5 간격씩 5.0까지 무릎관절 자기공명영상의 팬텀 실험과 임상실험 영상을 획득한 후, 방사선사 10명이 5점 척도로 영상을 평가하여 유의한 차이가 있는지 판단하였다. 연구 결과 T1 강조영상과 T2 강조 영상 모두 팬텀 실험은 가속계수 2.0 이하로 하였을 때 임상실험은 3.0 이하로 하였을 때 기준이 되는 1.0 영상과 차이가 없었다. 결론적으로 무릎관절 자기공명영상 검사 시 인공물이 발생하지 않으며 검사 시간을 최대로 단축할 수 있는 최적의 압축센스 가속계수는 팬텀 실험의 경우 2.0, 임상실험의 경우 3.0이 적정하리라 판단된다.
        4,200원
        1 2 3 4 5