검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 21

        1.
        2024.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The ductility of the system based on the capacity of each structural member constituting the seismic force-resisting system is a significant factor determining the structure’s seismic performance. This study aims to provide a procedure to supplement the current seismic design criteria to secure the system’s ductility and improve the seismic performance of the steel ordinary moment frames. For the study, a nonlinear analysis was performed on the 9- and 15-story model buildings, and the formation of collapse mechanisms and damage distribution for dynamic loads were analyzed. As a result of analyzing the nonlinear response and damage distribution of the steel ordinary moment frame, local collapse due to the concentration of structural damage was observed in the case where the influence of the higher mode was dominant. In this study, a procedure to improve the seismic performance and avoid inferior dynamic response was proposed by limiting the strength ratio of the column. The proposed procedure effectively improved the seismic performance of steel ordinary moment frames by reducing the probability of local collapse.
        4,000원
        2.
        2022.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        New buildings have been designed using different seismic design standards that have been revised. However, the seismic performance of existing buildings is evaluated through the same performance evaluation guidelines. Existing buildings may not satisfy the performance targets suggested in the current guidelines, but there are practical limitations to discriminating the existing buildings with poor seismic performance through a full investigation. In this regard, to classify buildings with poor seismic performance according to the applied standard, this study aimed to evaluate performance-based investigation of the seismic design proposals of buildings with different design standards. The target buildings were set as RC ordinary moment frames for office occupancy. Changes in seismic design criteria by period were analyzed, and the design spectrum changes of reinforced concrete ordinary moment resisting frames were compared to analyze the seismic load acting on the building during design. The seismic design plan was derived through structural analysis of the target model, compared the member force and cross-sectional performance, and a preliminary evaluation of the seismic performance was performed to analyze the performance level through DCR. As a result of the seismic performance analysis through the derived design, the reinforced concrete ordinary moment frame design based on AIK 2000 has an insufficient seismic performance level, so buildings built before 2005 are likely to need seismic reinforcement.
        4,000원
        3.
        2020.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In a previous paper, ambient vibration tests were conducted on a cable stayed bridge with resilient-friction base isolation systems (R-FBI) to extract the dynamic characteristics of the bridge and compare the results with a seismic analysis model. In this paper, a nonlinear seismic analysis model was established for analysis of the bridge to compare the difference in seismic responses between nonlinear time history analysis and multi-mode spectral analysis methods in the seismic design phase of cable supported bridges. Through these studies, it was confirmed that the seismic design procedures of the “Korean Highway Bridge Design Code (Limit State Design) for Cable Supported Bridges” is not suitable for cable supported bridges installed with R-FBI. Therefore, to reflect the actual dynamic characteristics of the R-FBI installed on cable-supported bridges, an improved seismic design procedure is proposed that applies the seismic analysis method differently depending on the seismic isolation effect of the R-FBI for each seismic performance level.
        4,000원
        4.
        2020.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, a field bridge test was conducted to find the dynamic properties of cable supported bridges with resilient-friction base isolation systems (R-FBI). Various ambient vibration tests were performed to estimate dynamic properties of a test bridge using trucks in a non-transportation state before opening of the bridge and by ordinary traffic loadings about one year later after opening of the bridge. The dynamic properties found from the results of the tests were compared with an analysis model. From the result of the ambient vibration tests of the cable supported bridge with R-FBI, it was confirmed that the dynamic properties were sensitive to the stiffness of the R-FBI in the bridge, and the seismic analysis model of the test bridge using the effective stiffness of the R-FBI was insufficient for reflecting the dynamic behavior of the bridge. In the case of cable supported bridges, the seismic design must follow the “Korean Highway Bridge Design Code (Limit State Design) for Cable supported bridges.” Therefore, in order to reflect the actual behavior characteristics of the R-FBI installed on cable-supported bridges, an improved seismic design procedure should be proposed.
        4,200원
        5.
        2018.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        One of engineered woods, glued laminated timber (GLT), can provide a constant level of performance and desired strength even if the quality of wood is low. Due to this fact, there is a growing interest in GLT using domestic species and related research has been carried out continuously. In addition, GLT is popularly being applied to the long-span or high-rise structures overseas. However, KBC 2016 does not allow the engineered woods to be used for middle and high-rise buildings by limiting height. Therefore, a proper design procedure and rationale should be clearly presented by the help of performance-based seismic design. With this background, the goal of this study is to establish a specific procedure for design of a 9-story building with RC shear walls and GLT frames according to the performance-based design of KBC 2016. The performance objectives were set according to KBC and the acceptance criteria for each goal were defined. The RC shear walls and GLT frames were designed by concrete and wood structure requirements, respectively. Analytical models were developed to reflect their nonlinear features, and both nonlinear static and dynamic analyses were conducted. Performance evaluation results showed that the shear walls have insufficient shear strength, so they were re-designed. Consequently, it has been confirmed that GLT frames can be applied to a 9-story office building with the assistance of RC shear walls and performance-based seismic design.
        4,000원
        6.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, performance based seismic design was performed on the shear wall structural system and the beam-column system as a variable general rebar and seismic rebar, and comparing the capacity of the two models of each system. From nonlinear analyses, the capacity of the shear wall structural system applying seismic rebar has shown a stable behavior after the maximum strength, but there is little difference. Furthermore, both models showed similar capacity between story drift and story shear force and capacity of members. These results are attributed to the fact that the seismic rebar, which is highly ductile under the seismic load applied to the target structure, does not render sufficient capacity.
        4,000원
        7.
        2016.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The objective of this study is to apply performance-based seismic design to high-rise apartment buildings in Korean considering collapse prevention level. The possible issues during its application were studied and the suggestions were made based on the findings from the performance-based seismic design of a building with typical residential multi-unit layout. The lateral-force-resisting system of the building is ordinary shear walls system with a code exception of height limit. In order to allow the exception, the serviceability and the stability of the ordinary shear wall structure need to be evaluated to confirm that it has the equivalent performance as the one designed under the Korean Building Code 2009. The structure was evaluated whether it satisfied its performance objectives to withstand Service Level and Maximum Considered Earthquake.
        4,000원
        8.
        2016.04 구독 인증기관·개인회원 무료
        This study describes the seismic performance evaluation of bridge structures located in Daegu. Structure design criteria focuses on the collapse or brittle fracture of the bridges when the earthquake situation is given. Thus, this study describes the seismic safety evaluation based on the design of a spectrum of ASCE-7 KBC2009 of the United States, South Korea architectural structure was based on using 3D linear elastic finite element model using the ABAQUS platform bridges. If the target structure was found to be vulnerable to tensile stress than compressive stress appeared to be a case of displacement Z-axis displacement is dominant.
        9.
        2013.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        비정형 초고층 구조물은 골조 직교성이 해제되고, 형상이 복잡해 기존 설계방식보다 많은 문제점이 발생된다. 비정형성으로 인한 문제점은 설계안을 지속적으로 변경시켜 프로젝트의 효율성을 저하시킨다. 또한 해외프로젝트의 경우 해당업체 간혹은 해당국가 간 의견차로 국내보다 더욱 많은 변경상황이 발생되고 있다. 따라서 지속적인 변경상황에 전산플랫폼을 사용할 경우 효율적으로 설계변경업무에 대처할 수 있다. 파라메트릭 기반의 전산플랫폼인 StrAuto를 이용할 경우 최적의 구조 설계대안을 신속히 선정할 수 있다. 특히 StrAuto는 비선형 내진성능평가를 위한 해석 툴 간의 신속한 모델링 연동도 효율적으로 가능하다. 그래서 본 연구에서는 지진하중 변경에 따른 전산플랫폼을 이용한 내진성능평가 프로세스를 현재 구조설계가 진행 중인 몽골지역 최고층 빌딩 프로젝트에 적용하고 검증하려 한다.
        4,000원
        10.
        2012.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 변위기반 성능설계 개념에 의해 기존 철근콘크리트 기둥과 콘크리트에 강재를 매입한 SRC 합성기둥에 대하여 최대 설계지진 가속도에 대한 내진성능개선의 성능설계을 비교하였다. SRC 합성기둥은 구조물의 강도를 증가시킬 뿐 아니라 연성도를 증가시키는 효과가 있다. SRC 합성기둥의 단면은 H형 강재와 원형의 중공 강관을 매입한 형태로 구성되어 있다. SRC 합성기둥에 대한 P-M상관도와 단면 공칭휨모멘트를 분석하고 이를 바탕으로 SRC 합성기둥에 대한 설계 변위 추정을 위해 변위기반 내진 설계 알고리즘을 제시하였다. 성능기반설계에 의한 성능개선설계를 위하여 목표성능변위 및 설계지진가속도 조건에 대해 직접변위 기반 설계방법 및 변위계수법에 의한 내진성능개선 설계 방법을 제시하였다. SRC 합성기둥은 기존 RC 기둥과 비교하여 성능개선 설계 결과 변위 연성비 및 변위성능에서 크게 개선된 성능설계 결과를 나타내었다.
        4,000원
        11.
        2010.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 기존 철근콘크리트 구조물에 대하여 대표적인 변위-기반 설계법인 Chopra&Goel 이 제안한 직접변위-기반 설계법의 기본개념을 적용하여 최대 설계지반 가속도에 대한 보강 Steel Jacket의 두께를 결장하고, 결정된 보강 두께를 적용하여 보강전 후 성능설계기법에 의한 비선형 해석 및 보강설계법에 의한 보다 개선된 알고리즘 및 프로그램을 제시하였다. Steel Jacket 보강된 철근콘크리트 기둥에 대한 설계 변위 추정을 위해 Steel Jacket 보강된 철근콘크리트 부재의 비선형 층상화 세그멘트 해석 모델을 제시하고, 성능기반설계에 의한 성능개선설계를 위하여 목표성능변위 및 설계자전가속도 조건에 대해 직접 변위-기반 설계 방법 및 변위계 수법에 의한 내진성능개선 설계 방법을 제시하였다. 적용 예에서 본 방법은 기존 철근콘크리트 기둥과 비교하여 성능개선설계 결과 보강 전에 비해 변위 연성비 및 변위성능에서 크게 개선된 성능설계 결과를 제공해 주었다.
        4,000원
        12.
        2007.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는, 기존 철근 콘크리트 구조물에 적용된 직접 변위-기반 설계법을 적용 FRP 피복 보강된 성능개선 콘크리트 부재에 대한 정밀 비선형 휨 해석 및 내진성능설계의 구체적 알고리즘을 제시하였다. 비선형 휨 해석의 정밀 예측을 위하여 콘크리트 및 FRP 복합재료의 다축 구성관계를 고려하였으며, Chopra 등 (1999)이 제안한 직접 변위-기반 설계법(DDM)을 개선하여 철근콘크리트 기둥에 대한 성능개선을 위한 FRP 피복 보강을 위한 성능설계 알고리즘을 제시하였다. 제시된 직접 변위-기반 설계법은, 변위계수법과 비교하여, 비선형 거동이 큰 경우에도 목표 변위 성능 값에 대한 정확한 추정을 해준다. 이는 변위계수법이 항복 이전의 유효탄성계수를 사용하는 반면, 직접 변위-기반 설계법은 유효탄할선탄성계수를 고려하고 있어, 목표 변위에 따른 성능설계 평가에 있어서 보다 높은 연성비의 거동을 반영하고 있기 때문인 것으로 평가된다.
        4,000원
        13.
        2007.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        공간구조물의 성능기초 내진설계를 위한 기초연구의 하나로 강구조 골조막 구조의 탄소성 지진응답 특성을 분석하였다. 하부 골조의 가새의 선행좌굴을 유도하여 상부에의 지진 에너지 전달을 저감할 수 있음을 보여주고 있다.
        4,000원
        14.
        2002.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 구조물의 설계방법에 국한되어 있는 직접 변위설계법을 응용하여 기존 구조물의 성능점을 산정하는 방법에 관하여 연구하였다. 개발된 방법을 이용하여 단자유도 구조물의 주기, 항복 후 강성비, 요구되는 탄성강도에 대한 항복강도비 등의 설계변수를 변화시키며, 지진 하중에 대한 응답을 구하고 그 결과를 분석하였다. 또한 10층 철골 골조의 내진성능 평가에 적용하였다. 제안된 방법의 정확성을 검증하기 위하여 기존의 내진성능 평가방법인 능력스펙트럼법과 시간이력해석법에 의한 결과와 비교하였다. 제안된 방법은 능력스펙트럼법과 동일한 결과를 보였으며 시간이력해석 결과와도 비교적 잘 일치하였다.
        4,000원
        15.
        1998.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A performance-based seismic design method for reinforced concrete building structures being developed in Japan is outlined. Technical and scientific background of the performance-based design philosophy as well as recently developed seismic design guidelines are is presented, in which maximum displacement response to design earthquake motion is used as the limit-state design criteria. A method of estimating dynamic response displacement of the structures based on static nonlinear analysis is described. A theoretical estimation of nonlinear dynamic response considering the characteristics of energy input to the system is described in detail, which may be used as the standard method in the new performance-based code. A desing philosophy not only satisfying the criteria but also evaluating seismic capacity of the structures is also introduced.
        4,200원
        16.
        1998.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, the necessity of developing effective nondestructive testing and monitoring techniques for the evaluation of structural integrity and performance is described. The evaluation of structural integrity and performance is especially important when the structures and subject to abrupt external forces such as earthquake. A prompt and extensive inspection is required over a large area of earthquake-damaged zone. This evaluation process is regarded as a part of performance-based design. In the paper, nondestructive testing and monitoring techniques particularly for concrete structures are presented as methods for the evaluation of structural integrity and performance. The concept of performance-based design is first defined in the paper followed by the role of evaluation of structures in the context of overall performance=based design concept. Among possible techniques for the evaluation, nondestructive testing methods for concrete structures using radar and a concept of using fiber sensor for continuous monitoring of structures are presented.
        4,000원
        17.
        2019.10 서비스 종료(열람 제한)
        우리나라의 경우 한정적인 대지조건으로 인해 고층 건축물의 수요가 증가하고 있으며 세계 각국을 포함한 국내의 지진 피해를 토대로 기존의 내진설계 기준은 강도설계법에서 성능기반설계법으로 적용되고 있다. 여기서 지진하중에 대응하는 구조물의 목표 성능수준을 각 부재의 비선형특성에 기반하여 만족하도록 설계하는 성능기반설계법 중에서도 목표성능수준을 변위에 맞추어 주어진 목표변위 이내로 응답이 제어될 수 있도록 설계하는 변위기반설계법을 다룬다. 특히 특수전단벽체 적용 연구자료를 구축하기 위해 두께 200mm를 갖는 22층 철근콘크리트 전단벽체구조에 대해 변위기반설계법을 토대로 내진성능 개선을 위한 내진성능 평가를 실시하고자 한다.
        18.
        2016.04 서비스 종료(열람 제한)
        In order to understand the seismic performance of weir structure under seismic events, concrete weir structure with infinite foundations was modeled in ABAQUS. Additionally, this study conducted the three different design response spectra based on KBC 2009, ASCE 7-05, and EuroCode 8. The results from numerical analyses showed that the seismic behavior of weir structure subjected to seismic ground motions was sensitive to natural frequency and mass participation factors.
        19.
        2016.04 서비스 종료(열람 제한)
        This study presented the seismic performance of weir structures with infinite foundations subjected to seismic ground motions, rather than finite soil foundation to avoid the reflection of seismic wave propagation at the mesh boundaries. The analytical model of weir structures was developed in ABAQUS platform and then the seismic performance of concrete weir structure was evaluated through design response spectrum (KBC 2009). It was revealed that the maximum stresses obtained from infinite models was significantly increased, in comparison to the finite models.
        20.
        2015.04 서비스 종료(열람 제한)
        The purpose of this study is to apply performance-based seismic design guideline to high-rise shear wall building. According to PEER TBI Guideline, the building is evaluated whether it satisfies the performance objectives which is to be capable of elastic response under Service Level shaking having a return period of 43years and to withstand Maximum Considered Earthquake shaking with prevention collapse.
        1 2