        61.
        2022.10 구독 인증기관·개인회원 무료
        Some Spent Fuel Pools (SFPs) will be full of Spent Nuclear Fuels (SNFs) within several years. Because of this reason, building interim storage facilities or permanent disposal facilities should be considered. These storage facilities are divided into wet storage facilities and dry storage facilities. Wet storage facility is a method of storing SNF in SFP to cool decay heat and shielding radiation, and dry storage facility is a method of storing SNF in a cask and placing on the ground or storage building. However, wet storage facilities have disadvantages in that operating costs are higher than that of dry storage facilities, and additional capacity expansion is difficult. Dry storage facilities have relatively low operating costs and are relatively easy to increase capacity when additional SNFs need to be stored. For this reason, since the 1990s, the number of cases of applying dry storage facilities has been increasing even abroad. Dry storage facilities are divided into indoor storage facilities and outdoor storage facilities, and outdoor storage facilities are mostly used to take advantage of dry storage facilities. In the case of outdoor storage facilities, the cask in which SNFs are stored is placed on a designed concrete pad. During this storage, the boring heat generated by SNFs cools into natural convection and the cask shields the radiation that SNFs generates. However, if an accident such as an earthquake occurs and the cask overturns during storage, there may be a risk of radiation leakage. Such a tip-over accident may be caused by the cask slipping due to the vibration of an earthquake, or by not supporting the cask properly due to a problem in the concrete pad. Therefore, in the case of outdoor dry storage facilities, it is necessary to evaluate the seismic safety of concrete pads. In this paper, various soil conditions were applied in the seismic analysis. Soil conditions were classified according to the shear wave velocity, and the shear wave velocity was classified according to the ground classification criteria according to the general seismic design (KDS 17 10 00). The concrete pad was designed with a size that 8 casks can be arranged at regular intervals, and 11# reinforcing bars were used for the design of the internal reinforcement of the concrete pad according to literature research. The cask was designed as a rigid body to shorten the analysis time. The soil to which the elastic model was applied was designed under the concrete pad, and infinite elements were applied to the sides and bottom of the soil. The effect on the concrete pad and cask by applying a seismic wave conforming to RG 1.60 to the bottom of the soil was analyzed with a finite element model.
        62.
        2022.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Unlike the CFT retrofit method, The EPFT retrofit method, which fills the steel tube with engineering plastic, does not require a separate concrete forming work and is a lightweight seismic Retrofit Method. In this study, an prototype model of the EPFT was proposed, and to analyze the seismic performance, an independent specimens and a reinforced concrete column were fabricated to conduct a seismic performance test. As a result of loading test of the independent specimens, the strength was increased compared to the steel tube column without internal filling, and the ductility ratio did not significantly increase due to the falling off of the weld. As a result of loading test of the concrete reinforcement specimen, the strength, ductility ratio, and energy dissipation were increased, and the number of cracks by loading step decreased compared to the non-reinforced specimen.
        4,000원
        63.
        2022.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Tuned mass damper (TMD) is widely used to reduce dynamic responses of structures subjected to earthquake loads. A smart tuned mass damper (STMD) was proposed to increase control performance of a traditional passive TMD. A lot of research was conducted to investigate the control performance of a STMD based on analytical method. Experimental study of evaluation of control performance of a STMD was not widely conducted to date. Therefore, seismic response reduction capacity of a STMD was experimentally investigated in this study. For this purpose, a STMD was manufactured using an MR (magnetorheological) damper. A simple structure presenting dynamic characteristics of spacial roof structure was made as a test structure. A STMD was made to control vertical responses of the test structure. Two artificial ground motions and a resonance harmonic load were selected as experimental seismic excitations. Shaking table test was conducted to evaluate control performance of a STMD. Control algorithms are one of main factors affect control performance of a STMD. In this study, a groundhook algorithm that is a traditional semi-active control algorithm was selected. And fuzzy logic controller (FLC) was used to control a STMD. The FLC was optimized by multi-objective genetic algorithm. The experimental results presented that the TMD can effectively reduce seismic responses of the example structures subjected to various excitations. It was also experimentally shown that the STMD can more effectively reduce seismic responses of the example structures conpared to the passive TMD.
        4,000원
        64.
        2022.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to evaluate seismic performances of a modular house system developed by a simple 4-clip fastening method and double metal assembly made of lightweight metals. In order to evaluate structural and non-structural seismic performances of the system. Shaking table test was carried out with full-scale modular units, and a nonlinear pushover analysis was performed to obtain suitable seismic responses for story drifts, displacements, force resistances and dynamic properties of the system. Through 3D analysis and shaking table test, the current method of lightweight modular metal unit assembly and systems with seismic performance of a 4-clip fastening type modular house were demonstrated safe and effective to seismic design.
        4,000원
        65.
        2022.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        New buildings have been designed using different seismic design standards that have been revised. However, the seismic performance of existing buildings is evaluated through the same performance evaluation guidelines. Existing buildings may not satisfy the performance targets suggested in the current guidelines, but there are practical limitations to discriminating the existing buildings with poor seismic performance through a full investigation. In this regard, to classify buildings with poor seismic performance according to the applied standard, this study aimed to evaluate performance-based investigation of the seismic design proposals of buildings with different design standards. The target buildings were set as RC ordinary moment frames for office occupancy. Changes in seismic design criteria by period were analyzed, and the design spectrum changes of reinforced concrete ordinary moment resisting frames were compared to analyze the seismic load acting on the building during design. The seismic design plan was derived through structural analysis of the target model, compared the member force and cross-sectional performance, and a preliminary evaluation of the seismic performance was performed to analyze the performance level through DCR. As a result of the seismic performance analysis through the derived design, the reinforced concrete ordinary moment frame design based on AIK 2000 has an insufficient seismic performance level, so buildings built before 2005 are likely to need seismic reinforcement.
        4,000원
        66.
        2022.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In assessing the seismic safety of nuclear power plants, it is essential to analyze the structures using the observed ground motion. In particular, spatial variation in which the characteristics of the ground motion record differ may occur if the location is different within the site and even if the same earthquake is experienced. This study analyzed the spatial variation characteristics of the ground motion observed at the structure and site using the earthquake records measured at the Hamaoka nuclear power plant. Even if they were located on the same floor within the same unit, there was a difference in response depending on the location. In addition, amplification was observed in Unit 5 compared to other units, which was due to the rock layer having a slower shear wave velocity than the surrounding bedrock. Significant differences were also found in the records of the structure’s foundation and the free-field surface. Based on these results, the necessity of considering spatial variation in the observed records was suggested.
        4,000원
        67.
        2022.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        시공 중인 건물은 시공이 완료된 건물과는 다르게 콘크리트의 강도발현이 충분히 이루어지지 않았기 때문에 지진과 같은 자연재해 에 더 취약한 모습을 가질 수 있다. 현재 국내 기준은 건축물의 내진등급별 최소성능 목표를 제시하고 있지만, 설계를 위한 지진하중은 재현주기 2,400년의 지진위험도를 기반으로 한다. 하지만 건물의 시공기간은 건물의 사용기간보다 훨씬 짧기 때문에 재현주기 2,400 년의 지진을 시공 중인 건물에 적용하는 것은 과도하다. 따라서 이 연구는 주거용으로 사용되는 철근콘크리트 건물의 시공 중 지진하 중을 분석하기 위해 5층, 15층, 25층, 60층 건물의 시공단계모델을 작성하고 재현주기에 따라 저감한 지진하중을 적용하여 구조적 안 정성을 확인하였다. 그 결과, 시공기간에 따라 선정한 재현주기의 지진을 적용할 때 구조적 안정성을 확인하였으며, 건물의 규모의 따 라 구조적 안전성을 확보할 수 있는 지진재현주기를 확인하였다.
        4,000원
        68.
        2022.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 기존 이력댐퍼와 프리스트레트 철계 형상기억합금(Fe SMA)을 결합한 새로운 하이브리드 댐퍼를 제안하고 이용가능성을 해석적으로 평가한다. 하이브리드 댐퍼는 강진 발생 시 모멘트 프레임의 에너지소산능력을 향상시키고 잔류변형 을 감소시키기 위한 목적으로 제안되었다. 구조해석 프로그램인 OpenSees를 통해 댐퍼의 각 요소에 대한 해석모델을 구축하였 고, 세가지 형식의 강재 가새프레임에 대해 시간이력해석을 수행하였다. 해석결과, 제안된 댐퍼는 모멘트 프레임의 최대 및 잔 류변형을 줄이는데 우수한 것으로 나타났다. 본 연구에 사용된 Fe SMA는 니켈-티타늄(Ni-Ti) 형상기억합금에 비해 5-10%에 해 당하는 낮은 재료 비용을 가지면서도 지진에 취약한 프레임 구조의 내진보강에 효과적인 결과를 보였다.
        4,000원
        69.
        2022.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        배관시스템은 대표적인 사회기반시설이다. 지진으로 인한 배관 손상은 심각한 피해를 초래할 수 있으므로 배관시스 템은 지진으로부터 반드시 보호되어야 할 필요가 있다. 지진은 설계기준을 초과하는 상대변위를 동반할 수 있다. 이러한 지진의 거동은 배관 이음부에 손상을 줄 수 있다. 배관시스템에서 과도한 변형이 발생할 수 있는 위치에 지진분리이음을 적용하면 내 진성능을 향상시킬 수 있다. 적층형 금속 벨로우즈는 지진과 같은 저주기 피로 하중에 대한 내구성이 우수하다. 따라서 다중 적층 형 금속 벨로우즈는 파이프의 면진 이음새로 사용할 수 있을 것으로 판단된다. 본 연구에서는 지진분리이음의 하나인 다중 적 층형 금속 벨로우즈에 대한 실험적 연구를 수행하였다. 2종류의 다중 적층형 벨로우즈 신축관이음에 대하여 단조하중 및 반복 하중재하시험을 수행하고 손상모드와 한계상태를 추정하였다. 그리고 단조재하시험과 반복재하시험의 결과를 비교 분석하였다.
        4,000원
        70.
        2022.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Most of the drinking water dams managed by the local governments in Korea are earthfill dams, and these dams have almost no geotechnical property information necessary for seismic performance evaluation. Nevertheless, in the rough planning stage for improving seismic safety for these dams, it is necessary to classify their relative seismic hazard against earthquakes and conduct an additional ground investigation. The zero seismic failure probability curve is a curve suggested in this study in which the probability of failure due to an earthquake becomes ‘0’ regardless of the geotechnical properties of the earthfill dam. By examining the method and procedure for calculating failure probability due to an earthquake suggested in previous researches, the zero seismic failure probability curves for an earthquake in 1,000-year and 2,400-year return periods in Korea were presented in the form of a hyperbola on the plane of the dam height versus freeboard ratio (ratio of freeboard to dam height), respectively. The distribution characteristics of the dam height and the freeboard ratio of 81 Korean earthfill dams were presented. The two proposed zero seismic failure probability curves are shown on the plane of the dam height versus freeboard ratio, and the relative seismic hazard of 81 dams can be classified into three groups using these curves as boundaries. This study presented the method of classifying the relative seismic hazard and the classification result.
        4,000원
        71.
        2022.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study is conducted to verify the seismic reinforcement effects of internally inserted buckling-restrained braces supported laterally by buckling-restrained rings for the seismic reinforcement of existing reinforced concrete buildings with non-seismic details. First, to evaluate the performance of KDS, the hysteretic characteristics of buckling-restrained braces are verified, and it is discovered that they satisfy the conformance criteria of the displacement-dependent damping device. Three full-scale, two-story reinforced concrete framework specimens are prepared to verify the seismic reinforcement effects, and the proposed buckling-restrained braces are bolstered with single diagonal and V-shaped braces to be compared with non-reinforced specimens. By performing a comparison with non-reinforced specimens that present intensive shear cracks at the bottom of first-floor columns, it is revealed that the maximum load and energy dissipation of specimens reinforced with the proposed buckling restrained braces, in which the structural damage extends evenly throughout the system, are approximately 4 and 6.2 times higher, respectively, which proves the effectiveness of the proposed seismic reinforcement method.
        4,000원
        72.
        2022.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        교량은 사용년한이 증가함에 따라 노후화로 인해 역학적인 성질과 구조적인 성능이 저하되고, 이로 인해서 강진 시에 내진성능이 저하된다. 교각과 교량받침에 대한 노후화를 몇 가지 단계로 정량화하여 해석모델에 반영하였고, 노후화된 교각과 교량받침에 대하 여 부재-수준의 지진취약도를 평가하였다. 교량 시스템의 파괴 메카니즘을 직렬시스템으로 가정하여, 부재-수준의 지진취약도 해석 결과로부터 시스템-수준의 지진취약도를 평가하는 방법을 제안하였다. 노후도에 취약한 부재인 교각과 교량받침에 대하여 5가지 정 량적인 노후도(0, 5, 10, 25, 40%)를 가정하여 부재-수준의 지진취약도를 평가하였고, 이 결과로부터 시스템-수준의 지진취약도 평가 를 수행하였다. 시스템-수준의 지진취약도는 교량받침 보다는 교각이 지배적인 영향을 줌을 알 수 있었다. 이는 보다 취약한 구조부재 의 지진취약도가 전체 교량시스템의 지진취약도에 지배적인 영향을 주는 것을 의미한다.
        4,000원
        73.
        2022.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 경주, 포항에 연이은 지진 발생으로 인하여 내진설계에 관심이 높아지고 있다. 다가구주택 필로티기둥은 수직 비정형 시스템으로 상,하부층의 강성 차이로 인하여 지진 발생 시 막대한 피해가 예상되기 때문에 다가구주택 필로티기둥의 내 진보강이 필요하다. 그러나 민간 소유인 다가구주택의 경우 막대한 비용과 시간으로 인하여 보강이 어려운 실정이다. 이에 따 라, 복합섬유패널로 에폭시 접착제 미사용으로 건식시공이 가능한 전단보강공법을 제안하고자 한다. 본 연구에서는 복합섬유패 널 보강 유무에 따른 내진보강공법의 전단내력을 실험을 통하여 검증하였고, 에폭시를 사용하지 않아 일체화 거동을 하지는 않 지만 복합섬유패널의 영향으로 전단내력은 1.46∼1.49배 증가하는 것으로 평가되었다. 따라서 다가구주택 필로티기둥의 내진보 강효과가 있을 것으로 판단된다.
        4,000원
        74.
        2022.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study investigated the seismic performance of reinforced concrete (RC) wall-slab frames with masonry infills. Four RC wall-slab frames with or without masonry infill were tested under cyclic loading. The RC frames were composed of in-plane and out-of-plane walls and top and bottom slabs. For masonry infill walls, cement bricks were stacked applying mortar paste only at the bed joints, and, at the top, a gap of 50 mm was intentionally left between the masonry wall and top RC slab. Both sides of the masonry walls were finished by applying ordinary or fiber-reinforced mortars. The tests showed that despite the gap on top of the masonry walls, the strength and stiffness of the infilled frames were significantly increased and were different depending on the direction of loading and the finishing mortars. During repeated loading, the masonry walls underwent horizontal and diagonal cracking and corner crushing/spalling, showing a rocking mode inside the RC wall-slab frame. Interestingly, this rocking mode delayed loss of strength, and as a result, the ductility of the infilled frames increased to the same level as the bare frame. The interaction of masonry infill and adjacent RC walls, depending on the direction of loading, was further investigated based on test observations.
        4,200원
        75.
        2022.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, an unprecedented emerging infectious disease has rapidly spread, causing a global shortage of wards. Although various temporary beds have appeared, the supply of wards specializing in infectious diseases is required. Negative pressure isolation wards should maintain their function even after an earthquake. However, the current seismic design standards do not guarantee the negative pressure isolation wards’ operational (OP) performance level. For this reason, some are not included in the design target even though they are non-structural elements that require seismic design. Also, the details of non-structural elements are usually determined during the construction phase. It is often necessary to complete the stability review and reinforcement design for non-structural elements within a short period. Against this background, enhanced performance objectives were set to guarantee the OP non-structural performance level, and a computerized tool was developed to quickly perform the seismic design of non-structural elements in the negative pressure isolation wards. This study created a spreadsheet-based computer tool that reflects the components, installation spacing, and design procedures of non-structural elements. Seismic performance review and design of the example non-structural elements were conducted using the computerized tool. The strength of some components was not sufficient, and it was reinforced. As a result, the time and effort required for strength evaluation, displacement evaluation, and reinforcement design were reduced through computerized tools.
        4,000원
        76.
        2022.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, centrifuge model tests were performed to evaluate the seismic response of multi-DOF structures with shallow foundations. Also, elastic time history analysis on the fixed-base model was performed and compared with the experimental results. As a result of the centrifuge model test, earthquake amplification at the fundamental vibration frequency of the soil (= 2.44 Hz) affected the third vibration mode frequency (= 2.50 Hz) of the long-period structure and the first vibration mode (= 2.27 Hz) of the short-period structure. The shallow foundation lengthened the periods of the structures by 14-20% compared to the fixed base condition. The response spectrum of acceleration measured at the shallow foundation was smaller than that of free-field motion due to the foundation damping effect. The ultimate moment capacity of the soil-foundation system limited the dynamic responses of the multi-DOF structures. Therefore, the considerations on period lengthening, foundation damping, and ultimate moment capacity of the soil-foundation system might improve the seismic design of the multi-DOF building structures.
        4,000원
        77.
        2022.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Seismic demand on nonstructural components (NSCs) is highly dependent on the coupled behavior of a combined supporting structure- NSC system. Because of the inherent complexities of the problem, many of the affecting factors are inevitably neglected or simplified based on engineering judgments in current seismic design codes. However, a systematic analysis of the key affecting factors should establish reasonable seismic design provisions for NSCs. In this study, an idealized 2-DOF model simulating the coupled structure-NSC system was constructed to analyze the parameters that affect the response of NSCs comprehensively. The analyses were conducted to evaluate the effects of structure-NSC mass ratio, structure, and NSC nonlinearities on the peak component acceleration. Also, the appropriateness of component ductility factor (R p) given by current codes was discussed based on the required ductility capacity of NSCs. It was observed that the responses of NSCs on the coupled system were significantly affected by the mass ratio, resulting in lower accelerations than the floor spectrum-based response, which neglected the interaction effects. Also, the component amplification factor (a p) in current provisions tended to underestimate the dynamic amplification of NSCs with a mass ratio of less than 15%. The nonlinearity of NSCs decreased the component responses. In some cases, the code-specified R p caused nonlinear deformation far beyond the ductility capacity of NSCs, and a practically unacceptable level of ductility was required for short-period NSCs to achieve the assigned amount of response reduction.
        4,300원
        78.
        2022.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        원자력발전소 기기 내진설계 및 지진해석은 비연계모델을 대상으로 수행된다. 그러나 이러한 비연계해석은 실제 구조물-기기 간 상호작용 등의 실제 현상을 모사할 수 없기 때문에 연계해석에 비하여 정확하지 못한 결과를 발생시키게 된다는 한계를 가진다. 이러 한 배경 아래 이 연구는 실제 원전 격납건물 구조물 및 관련 부계통을 대상으로 질량비와 고유진동수비를 고려하여 지진 연계해석과 비연계해석을 수행하고, 이를 바탕으로 부계통에서의 응답을 비교 분석하였다. 결과적으로 지진 연계해석 결과가 비연계해석 결과보 다 대다수 작은 값을 주는 것을 확인하였다. 이러한 결과는 기존 연구인 단순한 연계모델에 대한 해석 결과와 유사하지만, 부계통 응답 차이는 훨씬 더 두드러지게 나타나는 것을 확인하였다. 또한, 이는 지진파의 입력 주파수의 영향보다는 부계통의 설치위치에 영향을 받는 것으로 확인되었다. 마지막으로 비연계 및 연계 지진해석의 차이가 부계통의 질량비가 크고, 고유진동수가 거의 일치하는 영역 에서 발생하는 이유는 이 영역에서 주계통과 부계통 동적 상호작용이 크게 나타나기 때문인 것으로 보인다.
        4,000원
        79.
        2022.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 기존 비내진설계 콘크리트 기둥의 내진성능 개선을 위해 기둥 면적의 80% 영역을 12K 능직 카본 섬 유(CFRP sheet)와 카본용 에폭시 수지를 사용하여 보강한 후 보강량에 따른 내진성능을 실험적으로 평가하였다. 실험을 위해 실 험실 단위에서의 준실대형 기둥을 제작하였으며, 유압 풀링잭을 이용하여 약 10%만큼의 일정한 축력을 가력한 다음 변위제어를 통해 최대 10%의 변위비만큼 각 변위 사이클당 2회씩 반복 재하하여 가력을 수행하였다. 실험 결과 2겹의 12K CFRP sheet 보 강의 경우 누적에너지소산이 6.6배 증가하였으며, 4겹의 경우 9.6배 증가하였다.
        4,000원