검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 8

        1.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the types of thermal breakers applied to structures to prevent thermal bridges were identified. Condensation prevention performance was evaluated for apartment houses with standard floor structures to which a thermal breaker was applied. In addition, the effect of thermal cross-blocking was compared by calculating the total heat and equivalent U-value through the wall. (1) As a result of the evaluation of anti-condensation performance, when “가” grade insulation was applied, the surface temperature increased by about 1K due to the application of the thermal breaker. The TDR value increased by about 0.06 to 0.07. When "나" grade insulation was applied, the minimum surface temperature increased by about 1K, and the TDR value increased by about 0.05~0.06. (2) As a result of the evaluation of total heat and U-equivalent, it was possible to reduce the total heat by 38.5~44.9% and U-equivalent by 38.5~45.0% for the "가" grade insulation to which the thermal breaker was applied. In addition, the "나" grade insulation to which the thermal breaker was applied can reduce total heat by 38.9 to 43.6%, and reduce the Uequivalent by 38.9 to 43.7%.
        4,000원
        2.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, an accelerated weathering test was performed to examine the variation of thermal insulation performance according to the service life. A widely used class 1 thermal screen (matt georgette + polyethylene (PE) foam + chemical cotton + felt + matt georgette) was selected as the target thermal screen. The ultraviolet irradiation that reached the target thermal screen specimen (60 x 60cm) was 5mW/cm2. Thus, the ultraviolet irradiance was set to 5mW/cm2, and the exposure periods of accelerated weathering conditions on the specimens were set to 0, 282, 847, and 1412h. The radiation exposure periods of the weathering conditions for 0, 282, 847, and 1412h indicate the amount of ultraviolet accumulation for 0, 1, 3, and 5years, respectively. In the accelerated weathering test, the target specimens that completed each exposure phase were subjected to the hotbox test to analyze their thermal insulation performances. Consequently, the thermal insulation performance of the multi-layer thermal screen was estimated to degrade rapidly after approximately two years. In the accelerated weathering condition, a quadratic function model was used to calculate the expected service life, since it adequately described the variation in thermal insulation of the thermal screen according to time. The results showed that when the thermal insulation performance degraded by 5, 10, 20, and 30%, the expected service lives were 2.5, 3.3, 4.5, and 5.5years, respectively.
        4,000원
        3.
        2018.04 구독 인증기관 무료, 개인회원 유료
        The office building more than 3,000㎡ of the total floor area should be needed to improve the energy efficiency based on government's recommendation. In this study, the new composite panel with structural function is conducted to check the thermal conductivity for application of exterior wall. The thermal transmittance was calculated by dynamic analysis to consider the thickness of insulation only per locations based on design criteria. The simulation program for the analysis was used TRISCO Radcon module, which has a function of a steady-state 3-dimensional heat transfer analysis.
        3,000원
        4.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Numerical models of composite floor systems with various thickness of phase change material and sizes of circular spacers were developed based on finite element analysis. In order to perform a heat transfer analysis, thermal properties of steels were determined and those of phase change material were estimated from experiment results. In addition, the thermal insulation performance of composite floor systems with respect to different thickness of phase change material and sizes of circular spacers was predicted. To verify the validity of analysis, analysis results were compared with vertical furnace fire test results of equivalent conditions. As a result, available thicknesses of phase change material and sizes of circular spacers were proposed to satisfy the thermal insulation criteria of Korean Standards.
        4,000원
        5.
        2014.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 졸-겔, 용매치환, 표면개질, 상압건조 공정과 계면활성제에 의한 템플레이팅(templating) 공법 및 소결 공정을 이용하여 실리카 에어로겔 모노리스와 메조포러스 실리카 모노리스를 각각 합성하였다. 제조된 두 종류의 실리카 모노리스는 균열이 없이 비교적 투명하였으며, 매우 높은 기공율(92-94%) 및 비표면적(800 - 840 m²/g)과 수 십 nm 수준의 기공 크기를 갖는 것으로 확인되었다. 표면개질을 적용한 실리카 에어로겔 샘플이 스피링백 효과로 인하여 메조포러스 실리카 모노리스에 비해 더욱 미세하고 균질한 나노 기공 구조를 보였을 뿐만 아니라, 그 단열 성능도 더욱 우수한 것으로 나타났다. 본 연구를 통해 합성된 두 종류의 실리카 모노리스를 중간층으로 적용한 복층 창유리의 단열성능을 측정된 모노리스의 열전도도와 이론식을 근거로 조사한 결과, 기존의 상업적으로 응용되는 공기층 삽입 복층 창유리에 비해 우수한 단열 성능을 보이는 것으로 나타났다.
        4,000원
        6.
        2016.02 KCI 등재 서비스 종료(열람 제한)
        구명 조끼는 익수자의 부력을 유지시키는 기능을 가지며, 낮은 해수 온도에서 저체온증에 빠지는 시간을 단축 시킬 수 있는 역 할을 할 수 있다. 본 논문은 서멀 마네킹 실험과 수치적 방법을 적용하여 단열성능을 향상 시키기 위해서 개발된 팽창형 구명 조끼와 폼형 구명 조끼의 단열성능 및 저체온증 방지 효과를 평가하였다. 단열성능 평가를 위해서 서멀마네킨을 이용하여 열유속 및 열저항을 계측하였으 며, 본 연구에서 제시된 구명 조끼의 단열성능을 기존의 제품과 비교하여 검토하였다. 또한 저체온증에 빠지는 정도를 상대적으로 파악하기 위해서 유한요소해석을 이용하여 구명 조끼의 종류에 따른 체온 저감 시간을 예측하고 이를 비교 평가하였다. 저체온증 예측모델은 Pennes의 신체 열전달 해석 모델을 기반으로 작성되었으며, 실험으로부터 계측한 열저항 값을 이용하여 대류 열전달 조건을 환산하여 계산되었다. 그 결과 본 연구에서 단열성능을 향상시키기 위해서 제시된 하는 구명 조끼가 기존 제품에 비해 단열성능이 우수하게 평가됨을 확인하였다.
        7.
        2014.07 KCI 등재 서비스 종료(열람 제한)
        건설구조물 상부의 단열은 에너지 절약 건설구조물에 있어서 중요한 요건 중 하나이다. 건설구조물 최상부는 단열성뿐만 아니라 방수성능도 중요하다. 이와 같은 이유로 단열성을 확보한 방수공법의 개발이 요구된다. 본 연구에서는 최근 일정 단열성능을 확보한 단열 보완형의 복합방수공법이 개발되어 해당 공법에 대한 단열성능을 평가하고자 하였다. 방수성 시험결과, 모든 시험체는 KS 표준 이상의 성능을보여주었다. 단열성 시험결과, 스티로폼 박스가 가장 높은 온도인 25.91℃, 버블시트 박스가 17.28℃, 단열시트 박스가 15.47℃, 단열보완형 방수시트가 24.11℃로 확인되었다. 시트 접합부의 열교현상을 관찰한 결과 열교현상은 발생하지 않았다. 단열보완형 복합방수공법은 단열성능을 확보하고 있는 것으로 판단된다.
        8.
        2013.04 서비스 종료(열람 제한)
        The energy consumption by buildings approximately reaches 25% of total korea energy consumption. The greatest part in the buildings of the energy consumption is building facade. but a few research projects on concrete comprising more than 70% of outsider of buildings has been tried. This research structural insulation concrete what improved insulation performance using insulation performance improve material