검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 1,823

        321.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, refined finite element (FE) analyses intended to evaluate the capacity of the existing water purification plant structures against seismic force are conducted with an aim to predict possibility generating tension crack and compression crushing. The FE models for three types of main plant structures were constructed to take ground condition, boundary condition, and water interaction into consideration for advanced simulation. The nonlinear dynamic analyses were performed by using ground motion data which have been used for seismic design. Both compression crushing and tention crack, which are distributed over concrete plant structures during peak ground acceleration (PGA), are investigated by analyzing failure possibility controlled with the strain limits. After observing FE analysis results, it is possible to predict tenstion cracking which can be found at some parts of the main structure.
        4,000원
        322.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Fiber-reinforced polymer (FRP) bars have advantages as a construction material, including corrosion resistance, lightweight and high tensile strength. However, FRP rebars have shortcomings, such as low elastic modulus comparing to the steel rebar. With these reasons, FRP bars have not been widely used to reinforced-concrete (RC) structures. To overcome these shortcomings, the steel-hybrid GFRP rebars were developed by the authors at Korea Institute of Civil Engineering and Building Technology (KICT). Mechanical properties of the developed steel-hybrid GFRP rebars were experimentally evaluated through this study. Both tensile and bonding tests were conducted and the mechanical performance was investigated as well as corrosion resistance. As a result of all tests, elastic modulus, tensile strength and boding strength of the steel-hybrid GFRP rebars were all improved in comparison with fully GFRP rebars.
        4,000원
        323.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Lifting plan in the large spacial structure is an important factor influencing the efficiency and economy of the construction process. The purpose of this study was deriving the requirements for lifting techniques as the basic research in the double spoke wheel roof structure construction. In the lift up erection method, management plan of the interference error in the column and outer-ring was needed that occur during lifting roof structure. In the bent erection method, material usage reduction plan was required by the structural design of the temporary bent. In the hybrid erection method, lifting plan was needed that minimizes weather condition and crane usage. All lifting techniques were required Value Engineering model for reduction of cost and construction period.
        4,000원
        324.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A retractable-roof spatial structure is frequently used for a stadium and sports hall. A retractable-roof spatial structure allows natural lighting, ventilation, optimal conditions for grass growth with opened roof. It can also protects users against various weather conditions and give optimal circumstances for different activities. Dynamic characteristics of a retractable-roof spatial structure is changed based on opened or closed roof condition. A tuned mass damper (TMD) is widely used to reduce seismic responses of a structure. When a TMD is properly tuned, its control performance is excellent. Opened or closed roof condition causes dynamic characteristics variation of a retractable-roof spatial structure resulting in off-tuning. This dynamic characteristics variation was investigated. Control performance of a passive TMD and a smart TMD were evaluated under off-tuning condition.
        4,000원
        325.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The seismic isolation system reduces the seismic vibration that is transmitted from foundation to upper structure. This seismic isolation system can be classified into base isolation and mid-story isolation by the installation location. In this study, the seismic behavior of dome structure with mid-story isolation is analyzed to verify the effect of seismic isolation. Mid-story isolation is more effective than base isolation to reduce the seismic responses of roof structure. Also, this isolation would be excellent in structural characteristics and construction.
        4,000원
        327.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        After an earthquake occurred in the Gyeongju, 2016, many low-story buildings have been questioned in terms of the seismic performance since mostly they have been exempted from the seismic design requirement since 1988. In this study, a 3-story moment resisting frame (MRF) building was analyzed and evaluated the seismic performance. Due to the insufficient seismic performance required for the seismic performance levels, three different seismic retrofit schemes were proposed and their seismic performances were re-evaluated. While steel brace and open shear wall retrofit systems mainly focused on the strength retrofit, the VES damper retrofit system is mainly to enhance the energy dissipation capacity of the system and resultes in the increased ductility. The original building and 3 retrofitted buildings were evaluated using the nonlinear static and nonlinear dynamic analyses and suggestions were proposed. Through the analysis of nonlinear time history and push-over using MIDAS/Gen program, damages of the building in terms of top story and average story drift and effect of reinforcement were analyzed.
        4,000원
        328.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, effectiveness of seismic retrofitting methods using passive damping devices was investigated through numerical analyses of short-period structures under earthquakes which have short-duration and high-frequency impulse characteristics similar to Geyongju earthquakes. Displacement spectra of elastic systems and ductility demand of inelastic systems were evaluated by increasing viscous or friction damping. The damping devices could reduce responses of the structures with shorter structural period than 0.2s. The earthquakes similar to impulse load did not induce the responses of the structures with longer period than 0.4s, and the effects of the damping devices which generates damping forces proportional to structural responses became insignificant.
        4,000원
        329.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, time and frequency domain characteristics of Gyeong-ju earthquakes were investigated, and nonlinear time history analyses were conducted for bi-linear hysteretic structures excited by short-duration ground accelerations. Previous studies showed that larger inelastic displacements than the peak displacement of the corresponding elastic system were observed especially for the structures with structural period shorter than 0.3s, and the similar results could be obtained when long-duration ground accelerations were used as excitation loads. For the short-duration earthquakes, however, the inelastic displacements were not so large and almost identical to the peak elastic displacements.
        4,000원
        330.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The Gyeong-Ju earthquake in the magnitude of 5.8 on the Richter scaleoccurred in September 12, 2016. Because there are many nuclear power plants (NPP) near the epicenter of the Gyeong-Ju earthquake, the seismic stability of nuclear power plants is becoming a social problem. In order to evaluate the safety of seismically isolated NPP, the seismic response of a NPP subjected to the Gyeong-Ju earthquake was compared with those of 30 sets of artificial earthquakes corresponding to the nuclear standard design spectrum (NSDS). A 2-node model and a simple beam-stick model were used for the seismic analysis of seismically isolated NPP structures. Using 2-node model, the effect of internal temperature rise, decrease of shear stiffness, increase of lateral displacement and decrease of vertical stiffness according to nonlinear behavior of lead-rubber bearing (LRB) were evaluated. The displacement response, the acceleration response, and the shear force response of the seismically isolated nuclear containment structure were evaluated using the simple beam-stick model. It can be observed that the seismic responses of the isolated nuclear structure subjected to Gyeong-Ju earthquake is significantly less than those to the artificial earthquakes corresponding to NSDS.
        4,000원
        334.
        2016.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study intends to evaluate the conservativeness of the fixed-base analysis as compared to the soil-structure interaction (SSI) analysis for the seismically isolated model of a nuclear power plant in Korea. To that goal, the boundary reaction method (BRM), combining frequency-domain and time-domain analyses in a twofold process, is adopted for the SSI analysis considering the nonlinearity of the seismic base isolation. The program KIESSI-3D is used for computing the reaction forces in the frequency domain and the program MIDAS/Civil is applied for the nonlinear time-domain analysis. The BRM numerical model is verified by comparing the results of the frequency-domain analysis and time-domain analysis for the soil-structure system with an equivalent linear base isolation model. Moreover, the displacement response of the base isolation and the horizontal response at the top of the structure obtained by the nonlinear SSI analysis using BRM are compared with those obtained by the fixed-base analysis. The comparison reveals that the fixed-base analysis provides conservative peak deformation for the base isolation but is not particularly conservative in term of the floor response spectrum of the superstructure.
        4,200원
        335.
        2016.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 연구에서는 p-version 동적무한요소법을 도입함으로써 FE-IE 기법에 기반한 KIESSI-3D 프로그램의 속도향상에 역점 을 두었다. KIESSI-3D의 성능을 평가하기 위해 8가지 실규모 SSI 문제에 대한 수치해석을 수행하였다. 이를 위해 근역지반 모델의 반경( r0 )이 구조물기초 반경(R)의 1.2배, 1.5배, 3.0배인 KIESSI-3D 해석모델을 고려하였다. 또한 SASSI2010 프로그 램을 이용한 SSI 해석을 수행하였으며, 이 결과를 KIESI-3D에 의한 결과와 정확성 및 계산속도를 비교하였다. 수치해석 결 과, 인 KIESI-3D 모델을 사용하면 정확한 해석을 수행할 수 있음을 알 수 있었다. 계산속도 측면을 보면, 새로운 KIESSI-3D의 해석속도는 기존 KIESSI-3D에 비해 최대 25배 빠른 것으로 나타났다.
        4,300원
        336.
        2016.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        1970년대 이후 한국의 빠른 경제성장 동안에 수로나 철도 등 많은 지중구조물들이 건설되었다. 1988년에 내진설계가 의무 화되었으나, 1988년 이전의 지중 구조물들은 내진설계가 반영되지 않았다. 따라서, 이러한 지중 구조물들은 지진이 일어났을 때 안전성을 확보하기 위해 효과적인 내진 보강방법이 필요하다. 그러한 이유로, 본 연구에서는 새롭게 개발된 보강재를 이 용한 RC 박스 지중 구조물 우각부 보강공법의 내진성능에 대하여 분석하였다. 이 공법은 박스구조물 우각부에 Pre-flexed member를 설치하여 외력에 저항력을 증대시키는 원리이다. 타당성을 검증하기 위해서 새로이 개발된 보강재와 기존의 보강 재를 실험과 유한요소해석으로 비교하였다. 유한요소모델에서 강재의 비선형 모델은 J2 Plasticity Model을 기초로 하고 콘 크리트는 CEB-FIP MODEL CODE 1990로 모델링되었다. 또한, 설계반영을 위한 박스 구조물과 보강재와의 합성률을 산정 하였다. 보강재와 박스구조물은 Tie에 의해 완전 부착된 상태의 연결조건 하에서 해석이 수행되었으며, 하중-변위곡선에서 실험과 유한요소해석의 결과가 서로 일치하였다.
        4,000원
        337.
        2016.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 연구는 기초의 묻힘이 면진 원전구조물의 응답에 미치는 효과를 지표기초와 비교하여 평가하였다. 면진장치의 비선형 성을 고려한 비선형 SSI 해석은 진동수영역해석과 시간영역해석의 복합법인 경계반력법(BRM)을 이용하여 수행하였다. BRM 해석모델은 BRM을 이용한 등가선형 SSI 해석결과를 재래의 주파수영역 SSI 해석결과와 비교함으로 검증하였다. 마 지막으로 비선형 SSI해석에 의한 묻힌기초 모델의 면진장치의 변위 및 구조물 응답을 지표기초의 해석결과와 비교하였다. 비교결과, 면진장치의 변위응답은 묻힌기초효과를 고려할 경우 감소할 수 있음을 알 수 있었다.
        4,300원
        338.
        2016.10 구독 인증기관 무료, 개인회원 유료
        In this study, the fracture property of the bonded structure with aluminum foam is analyzed by using the closed aluminium foam for impact absorber. DCB and TDCB specimens manufactured with the single lap joint method of mode 3 are designed by varying the thickness. The static analysis through ANSYS finite element program is carried out on the specimen model due to each thickness. Also, the static experiment is performed in order to verify the analysis result. This study aims at comparing the shear strengths of the bonded structures of DCB and TDCB made with aluminum foam and investigating the mechanical properties.
        3,000원
        339.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Cable network system is a flexible lightweight structure which curved cables can transmit only tensile forces. The weight of cable roof dramatically can reduce when the length becomes large. The cable network system is too flexible, most cable systems are stabilized by pretension forces. The tensile force of cable system is greatly influenced by the sag ratio and pretension forces. Determining initial sag ratio of cable roof system is essential in a design process of cable structures. Final sag ratio and pretension depends on initial installed sag and on proper handling during installation. The design shape of cable system has an affect on the sag and pretension, and must be determined using well-defined design philosophy. This paper is carried out the comparative data of the deflection and tensile forces on the geometric non-linear analysis of cable network systems according to sag ratio. The study of cable network system is provided to technical informations for the design of a large span cable roof, analytical results are compared with the results of other researchers. Structural nonlinear analysis of systems having cable elements is relatively complex than other rigid structural systems because displacements are large as a reason of flexibility, initial prestress is applied to cables in order to increase the rigidity, and then divergence of nonlinear analysis occurs rather frequently. Therefore, cable network systems do not exhibit a typical nonlinear behavior, iterative method that can handle geometric nonlinearities are necessary.
        4,300원
        340.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The Eradi Quake System (EQS) is a seismic isolation bearing system designed to minimize forces and displacements experienced by structures subjected to ground motion. The EQS dissipates seismic energy through friction of Poly Tetra Fluoro Ethylene (PTFE) disk pad. In general, a force-displacement relationship of EQS has post yield stiffness hardening during large inelastic displacement. In this study, seismic responses of seismically isolated nuclear power plant (NPP) subjected to design basis earthquake (DBE) and beyond design basis earthquakes (150% DBE and 167% DBE) are compared considering the post yield stiffness hardening effect of EQS. From the results, it can be observed that if the post-yield stiffness hardening effect of EQS is increased, the displacement response of EQS is reduced, and the acceleration and shear responses of containment structures of NPP is increased.
        4,200원