검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 2,342

        303.
        2020.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to optimize the composition of the medium for turmeric fermentation and to select competent turmeric fermentation strains using bacterial isolates from kimchi. Initially, 30 isolates from kimchi were cultured in 5% (w/v) yeast extract and 1% (w/v) maltodextrin to determine viability. As a result, eight strains showed a tendency to maintain viability until the fifth day of fermentation. Subsequently, the eight isolates were fermented in an optimum medium for turmeric fermentation, 5% (w/v) yeast extract, 1% (w/v) maltodextrin, and 5% (w/v) turmeric for seven days to determine the viable cell count and antioxidant capacity. The antioxidant capacities of turmeric fermented by the eight isolates were similar or higher than turmeric fermented by Lactococcus lactis KCTC 2013, while maintaining high viable cell counts of both the eight isolates and L. lactis KCTC 2013 until the seventh day of fermentation. The antioxidant capacities of the selected five strains during fermentation might increase possibly due to the biological conversion of active compounds in turmeric by fermentation. Consequently, a total of five strains of the isolates showing higher antioxidant capacity (4.81±0.19-5.81±0.04 VCE/mL) than fermentation day 0 were selected for fermentation of turmeric.
        4,000원
        304.
        2020.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to optimize the rice starch and rice protein content ratio for the replacement of fish paste in eomuk using a response surface methodology. The experiment was designed based on the independent variables. The rice starch content (X1: 10, 20, 30%) and rice protein content (X2: 1, 3, 5%) were examined, along with the viscosity (Y1), color (Y2: L, Y3: a, Y4: b), and sensory evaluation of the dough (Y5: Color, Y6: Flavor, Y7: Off flavor, Y8: Taste, Y9: Hardness, Y10: Cohesiveness, Y11: Springiness, Y12: Chewiness, Y13: Overall acceptance), with the results being set as dependent variables. The p value of Y1, Y2, Y5, Y7, Y9, Y10, Y11, Y12, and Y13 showed a level of <0.05 excluding Y6 and Y8. R2 value was high at 0.80-0.95 so that these rice starch and rice protein contents were significantly affected in terms of the quality and sensory preference of eomuk; therefore, the optimal conditions of X1 and X2 were 19.99% and 2.91%, respectively. Under these optimal conditions, the predicted values of acceptance were Y5 (5.44), Y7 (5.36), Y9 (5.22), Y10 (5.46), and Y13 (6.11). These results will be the basis for building a method for obtaining a rice material. Also, they are expected to promote rice consumption through the development of processed foods using rice material.
        4,000원
        310.
        2020.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The battle vehicle has six types of indicators attached to the instrument panel in consideration of the special battlefield environment. However, many problems of moisture occurred during the operation of combat vehicles. These moisture phenomena can adversely affect aesthetics and functionality. Moisture is generated on the instrument panel due to the inflow of external moist air, the desorption of the moist air inside the parts, and the fluctuation of the dew point temperature. In this paper, we try to derive the root cause of various moisture generation and provide an improvement measures for moisture control. Therefore, the failure mechanism of the instrument panel may be analyzed and the design may be changed depending on the failure factor. Furthermore, the effect of the design change is verified, and the humidity performance is evaluated.
        4,000원
        311.
        2020.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, a smart skin system that combines SPD (suspended particle display) and LGG (Lighting Guide Glass) and its optimal control method was developed for the purpose of simultaneously reducing the lighting load and cooling load in office buildings. And a demonstration site was built to test the results. The demonstration site was constructed as an experimental group with a smart skin system installed and a control group with a general window system installed. When the cooling energy consumption of the experimental group to which the smart skin system was applied was reduced by about 36.9% compared to the control group, the lighting energy was also reduced by 54.4%.
        4,000원
        312.
        2020.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper is about the selection of the optimum position of the driving system and the analysis of the load at that position in order to safely drive an object with heavy load on the turret with a linear actuator. Usually, linear actuator is required the greatest force when first lifting or pushing a structure, and it is determined by the initial angle and positions. After all, the optimal position of the linear actuator in a limited turret space is closely related the required load and driving performance of the linear actuator. Therefore, this paper contains the contents of securing the driving stability and performance at optimum position on the turret by considering the two cases of linear actuator position arrangement.
        4,000원
        313.
        2020.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, a model to optimize residual chlorine concentrations in a water supply system was developed using a multi-objective genetic algorithm. Moreover, to quantify the effects of optimized residual chlorine concentration management and to consider customer service requirements, this study developed indices to quantify the spatial and temporal distributions of residual chlorine concentration. Based on the results, the most economical operational method to manage booster chlorination was derived, which would supply water that satisfies the service level required by consumers, as well as the cost-effectiveness and operation requirements relevant to the service providers. A simulation model was then created based on an actual water supply system (i.e., the Multi-regional Water Supply W in Korea). Simulated optimizations were successful, evidencing that it is possible to meet the residual chlorine concentration demanded by consumers at a low cost.
        4,200원
        314.
        2020.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근, L형 도로측구 상 열화, 균열로 인한 유지보수 작업이 빈번해지고 있다. 본 논문에서는 쐐기 앵커를 이용한 L형 도로측구의 최적 설계에 대해 제시하고자 하였다. 해석 결과, 두 개의 쐐기앵커를 350mm로 관입시킨 경우에서 구조적 안정성을 충분히 확보하는 것을 확인하였다. 또한 3%의 개질유황 콘크리트 배합이 압축강도, 동결융해 등의 내구성 기준을 만족하였다. 반복하중에 대한 수치해석과 현장 평가가 수행 중에 있으며, 추후 해당 시스템의 적용성을 평가하기 위한 추적 조사가 이루어져야 할 것이다.
        4,000원
        320.
        2020.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study analyzed the appropriate placement method by floor for evacuating all occupants during the nighttime through evacuation simulation. The analysis results are as follows. First, when non-self evacuating patients were placed on the first floor, 266 patients and 6 workers were found to be evacuated after 460 seconds. This result shows that it is meaningful to place non-self evacuating patients on the lower floor with a time that is faster than 540 seconds, which is an evaluation criterion set using life Safety standards for human. This result is a time faster than the evaluation criteria of 540 seconds, which is set using the life safety standards, and it can be confirmed that it is meaningful to place non-self evacuating patients on the lower floor. Next, as a result of placing non-self evacuating patients from the first floor to the fourth floor, it was found that evacuation of all occupants required 460 seconds for the first floor, 834 seconds for the second floor, 1,508 seconds for the third floor, and 1,915 seconds for the fourth floor. These results indicate that the placement of non-self evacuating patients on the rest of the floors, except for the first floor, can lead to dangerous results in excess of 540 seconds, which is a flashover time. As a result, it is necessary to place non-self evacuating patients on a lower floor for safe evacuation. The study has limitations except for comparative analysis of changes in evacuation time due to changes in the number of workers at eldery care hospitals and situations in which fire-fighting facilities such as sprinkler facilities operated. It is necessary to study the evacuation time linked to the operation of the fire-fighting facilities and the evacuation time according to the change in the number of workers in the future.
        4,000원