검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 454

        261.
        2016.04 서비스 종료(열람 제한)
        When substation structures are designed, it is important to investigate the design, construction and maintenance plans to enhance the endurance for chloride environment, freezing and electrochemical attack. The research is conducted to investigate intended service life of reinforced concrete substation structures.
        262.
        2016.04 서비스 종료(열람 제한)
        Concrete behaves as a brittle material with low tensile strain capacity. By adding fibers, the cracking in concrete matrix is controlled, and the durability is improved. In this study, the microstructure and Chloride diffusion resistance of fiber reinforced concrete are compared with fiber type and fiber volume fraction. From the results, the fiber mixed in concrete must be at least 0.5% regardless fiber type, in order to ensure the chloride diffusion coefficient higher than OPC at 91days. However, the micro structure distribution is affected with fiber volume fraction and fiber type at range 10~100nm.
        263.
        2016.04 서비스 종료(열람 제한)
        In this research, we carried out design and analysis with joint of concrete supporting structure for offshore wind energy. We developed load transfer mechanism about applied load induced from steel tower to concrete foundation. Also, a commercially available finite element program, ABAQUS 6.10, is used to analyze behavior of structure.
        264.
        2016.04 서비스 종료(열람 제한)
        The purpose of this study is to estimate structural integrity evaluation of the concrete pontoon structure when the boundary condition and time changes. The structural integrity evaluation is conducted through the system identification method using dynamic properties. Dynamic properties are extracted with the structures when it is located on the ground and submerged in the sea. The variation of the structural stiffness due to a certain period time is discussed.
        266.
        2016.01 KCI 등재 서비스 종료(열람 제한)
        이 연구의 목적은 개착식 전력구 콘크리트에 발생하는 부등건조수축에 의한 균열특성을 파악하고, 그 제어방법을 제시하는데 있 다. 건조수축균열은 콘크리트 내부의 수분확산계수의 영향을 크게 받으며, 수분확산계수는 콘크리트 내부에서의 수분이동속도를 결정하는 주요인자이다. 수분확산계수와 더불어 콘크리트 표면의 표면계수와 외부의 상대습도는 콘크리트 내부에서 외부로의 수분이동에 영향을 미친 다. 따라서 이 연구에서는 전력구 박스형 콘크리트 구조물의 부등건조수축에 의한 균열특성을 파악하기 위하여 세 가지 주요영향인자를 고려 한 수치해석을 수행하였다. 수치해석 결과, 수분확산계수와 표면계수가 증가할수록 상부슬래브의 부등건조수축에 의한 균열발생시점이 빨라 지며, 세 가지 요인 중에 콘크리트의 부등건조수축에 의한 균열발생 특성에 가장 큰 영향을 미치는 것은 외기습도인 것으로 나타났다. 이 연구 결과를 분석한 결과, 개착식 전력구 시공시에 콘크리트 타설 후 표면보습이나 살수양생과 같이 외기습도를 증가시키는 것이 부등건조수축에 의한 균열제어에 가장 효과적인 것으로 판단되며, 콘크리트 재료적 측면의 균열저감방법으로 수분확산계수와 표면계수를 결정하는 콘크리트 의 배합이나 재료특성을 적절히 선정함으로써 균열의 진전속도나 발생시점을 제어할 수 있을 것으로 판단된다.
        267.
        2015.11 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 유황을 폴리머화하여 콘크리트 표면보호재로 활용가능성을 검토하기 위하여 내구성능 및 생물독성 평가를 실시하 였다. 평가 결과, 콘크리트 표면보호재의 내화학성능은 산, 알칼리 용액에 대하여 화학저항성이 우수한 것으로 나타났다. 배합조건별 촉진내후 성 실험 후 부착강도평가 결과 규사분말 및 플라이애시를 동시에 혼합한 배합에서 가장 우수한 강도특성을 나타내었다. 콘크리트용 표면보호 재 시험체의 온냉반복 후에도 모든 배합조건에서 부착강도 1 MPa을 상회하였고, SFS배합에서 가장 높은 부착강도를 나타내었다. 표면보호재 를 도포한 콘크리트의 촉진탄산화 및 염소이온침투저항성을 검토한 결과, 규사분말을 채움재로 사용한 표면보호재를 도포한 시험체에서 가장 우수한 내구성능을 나타내었다. 유황폴리머를 콘크리트 표면보호재로 사용시 생물독성 검토를 위해 어독성 실험을 수행한 결과, 유황폴리머 는 생물에 미치는 영향은 없는 것으로 나타났다. 표면보호재의 내화학성, 동결융해저항성, 탄산화, 염소이온침투저항성 등을 모두 고려하여 볼 때, 본 연구범위에서는 유황폴리머에 채움재로서 규사분말과 플라이애시를 각각 20%씩 대체하는 것이 적절한 수준인 것으로 판단된다.
        268.
        2015.11 KCI 등재 서비스 종료(열람 제한)
        이 연구의 목표는 학교 건물과 같은 저층 보-기둥 철근콘크리트 구조 건물에서 프리캐스트 벽패널을 사용한 새로운 내진보강 방법 을 개발하는데 있다. 1개의 무 보강 보-기둥 실험체와 U형 PC 패널로 보강한 2개의 보강 보-기둥 실험체에 대한 정적 이력 하중실험을 진행하 였다. 앵커 접합부 실험체는 전단 파괴될 것으로 해석되었고 철판 용접 접합부 실험체는 휨 파괴할 것으로 예측되었다. 실험체의 종국 내력은 상부 접합부의 전단 내력과 PC 패널 절곡 부 휨 위험단면에서 휨 내력 중 약한 것으로 결정되었다. 이 실험체에서, 한쪽 RC기둥이 가 하중(미는 실험 하중)을 받아 PC 패널 부재를 밀게 된다면, 다른 쪽 내부 수직부재는 상부 전단 접합부로부터 부 하중(당기는 실험 하중)을 받게 되어있었 다. 가 하중을 받는 2개의 부재는 합성 휨 거동이 지배적이므로 합성단면의 휨 내력이 실험체의 최종 내력을 결정하게 되지만, 이 경우 최종 내 력에 대하여 상부 전단 접합부 강도의 직접적인 영향은 없다고 볼 수 있다. 그러나 부 하중(당기는 하중)을 받는 RC 기둥과 PC 패널 부재는 비 합성 거동이 지배적이고 실험체의 최종 내력은 상부 전단 접합부 전단내력의 크기에서 직접 영향을 받는 것으로 파악되었다. ACI 318M-11 Appendix-D 앵커 전단설계에 기초한 전단내력 그리고 실험에서 얻은 최대하중을 적용하여 마이다스 젠 탄성설계에 의하여 계산한 전단 외력 에 대한 비교 해석결과는 실험결과와 일치하는 해석결과를 보여주었다.
        269.
        2015.10 서비스 종료(열람 제한)
        The present study concerns a measurement of porosity at the nano-fibre interface in concrete. Concrete cast with a centrally located nano-fibre (Ø0.39 × 15.0 mm) was segmented for microscopic observation at a bascattered electron (BSE) image. As a result, it was found that the pores generated in the vicinity of the nano-fibre ranged from 5.40 to 11.45%, equivalent to 0.51 - 1.08% of air void in a bulk concrete.
        270.
        2015.10 서비스 종료(열람 제한)
        In the current concrete structure of the highway is still the major problem most of concrete deterioration caused by the freeze-thaw and de-icing salt, which is of issues that are not completely resolved. In particular, a single freezing event does not cause much harm, durability of concrete under multi-deterioration environment by repeated freeze-thaw and de-icing salt is rapidly degraded and reduce its service life. In this study, to considering environmental characteristics when design and construction of concrete structures, the exposure environmental guidelines were established by investigation the application rates of de-icing salt, temperatures and snowfall characteristics during five years (2004∼2008) by regions. Also, damage condition and chloride content of the structural at regions of moderate and severe environmental exposures were investigated.
        272.
        2015.10 서비스 종료(열람 제한)
        Traditional methods for concrete structure demolition is not adequate specially for urban areas and historical places due to hazard of explosive and noise. Therefore, Soundless Chemical Demolition Agents (SCDA) is useful in urban area and historical places. In this study, a analysis for SCDA is performed depending on boundary conditions.
        273.
        2015.10 서비스 종료(열람 제한)
        A new approach to evaluate the durability of concrete structures was proposed in this study, which additionally considered the time-dependent and environmental effects, especially freezing-thawing and salt attack. This might have a potential for the reasonable durability evaluation with the systematic management of SOC facilities.
        274.
        2015.10 서비스 종료(열람 제한)
        This study aimed to propose a reasonable performance evaluation process of freeze-thaw and carbonation depth on concrete structures, especially considering the time-dependent and environmental effects, to develop a long-term maintenance plan in Korea.
        275.
        2015.10 서비스 종료(열람 제한)
        This study relates to a crack repair techniques in the concrete structure. In order to develop repair material containing self-healing agents, smart repair methods were investigated. For the micro cracks of less than 0.3 ㎜, new repair method of surface treatment was suggested by the simple crack repair stick. In case of over 0.3 ㎜ cracks, injection method using inorganic materials was suggested for drying shrinkage and water leakage.
        276.
        2015.10 서비스 종료(열람 제한)
        In this research, we used half model instead of full model in order to consider convergence and analysis running time. We carried out nonlinear analysis on the joints between steel tower to concrete supporting structure of the 5MW offshore wind turbine applying only half of the load on the joint.
        277.
        2015.10 서비스 종료(열람 제한)
        From the previous research, as a solution of carbonation of high-volume SCM concrete, outstanding performance of emulsified refined cooking oil with applying on the surface of the concrete was suggested. As a comparative study, the aim of this research is evaluating carbonation resistance and pore structure of high-volume SCM concrete depending on the painting substances of emulsified refined cooking oil and modified silicate base permeating paint, which is commercial product by mock-up test.
        278.
        2015.09 KCI 등재 서비스 종료(열람 제한)
        콘크리트 표면의 상태에 따라 염화물은 증가 또는 감소하게 되며 이는 철근부식 및 내구수명에 매우 중요한 인자가 된다. 콘크리트의 내구성 저하를 방지하기 위해 표면함침과 같이 많은 표면강화 기술이 개발되었으나 이중 콘크리트 구조와 확산계수의 시간의존성을 고려한 염화물 해석방법은 매우 제한적이다. 본 논문에서는 표면 강화된 이중구조 콘크리트에 대해 시간의존성 확산계수를 도입하여 염화물 해석기법을 제안하였으며, 역해석을 통하여 기존의 실험결과와 비교하였다. 2년간 비말대, 해수중, 조석대 상태에 노출된 표면 함침된 콘크리트 시편에 대해 표면염화물량과 확산계수를 도출하고 Life-365에서 제안한 확산계수 식과 비교 분석하였다. 시간의존성을 고려한 결과 비말대 시편의 오차는 0.28에서 0.20 수준으로, 조석대 시편은 0.29에서 0.11 수준으로, 해수중에서는 0.54에서 0.40 수준으로 오차가 감소함을 알 수 있었다. 또한 Life365에서 사용되는 확산계수식을 사용할 경우, 과다한 확산계수로 인해 상대오차가 커지고 높은 침투깊이(e)와 낮은 확산계수비(D1/D2)를 필요로 함을 알 수 있다.
        279.
        2015.09 KCI 등재 서비스 종료(열람 제한)
        이 연구의 목표는 학교 건물과 같은 저층 보-기둥 철근콘크리트 구조 건물에서 프리캐스트 벽패널을 사용한 새로운 내진보강 방법을 개발하는 것이다. 1개의 무 보강 보-기둥 실험체와 U형 PC 벽패널로 보강한 2개의 보강 보-기둥 실험체에 대한 정적 이력 하중실험을 진행하였다. 앵커접합 PR1-UA 실험체와 철판접합 PR1-UP 실험체는 무 보강 실험체보다 평균 2.8배(평균 591.8 kN)의 강도 증가를 보여 주었다. 최대 변위비도 1.4%에서 2.7%사이 값을 보여주었다. RC 골조 우측 상단에서 좌측방향으로 가력 할 때 우측에 있는 RC 기둥과 보강 PC 패널의 수직 요소는 완전 합성상태로 가정하였고, 좌측에 있는 RC 기둥과 PC 패널은 완전 비 합성 거동하는 것으로 가정하여 해석한 결과 전체적인 휨 거동은 실험 결과와 대체적으로 부합하는 것으로 판단되었다.
        280.
        2015.04 서비스 종료(열람 제한)
        Chloride attack, one of the reasons for early deterioration of concrete, is a phenomenon where detrimental ions such as chlorine ion penetrate into concrete from outside to diffuse and corrode the steel rebar, greatly deteriorating the durability of RC members or structures. Sources of chloride attack can be divided into the direct / indirect influence caused by seawater or its splash in the maritime environment and the de-icing salts used for the purpose of thawing the ice on the wintry road. Most notably, the usage of de-icing salts is essential for the safety of drivers and smooth traffic flows in expressways. However, they also quicken the deterioration of concretes, necessitating the countermeasures for the problem. This paper discusses the early deterioration and measurements of RC Structures under de-icing salts environments.