검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 8

        1.
        2008.02 구독 인증기관 무료, 개인회원 유료
        The average BOD concentration was found to be about 269mg/L before a process innovation, but after the innovation, it became 30mg/L, which satisfied the effluent standard of 120mg/L. The removal effluent standard of 120mg/L. The removal efficiency was about 60~80%, and the concentration of the treated water was found th be low. after the process innovation, the average COD concentration was 29mg/L, and the CODmn removal efficiency became low to the level of about 65~76%, which was found lower than the effluent standard of 130mg/L. After the process innovation the SS average concentration of the treated water was 13mg/L, which was lower than that before the innovation (32mg/L). By the activated sludge process innovation, the SS removal efficiency was improved to be 30~70%. The average concentration of total coliform before the process innovation was 6100 count/mL because an Activated sludge process only occasionally pass over the allowed standard(The average number of the total coliform of Activated sludge process treated water was about 8100 count/mL), UV disinfection process was introduced. after the introduction, the average number of the total coliform was 1800 count/mL, which satisfied the allowed effluent standard of 3000 count/mL.
        4,300원
        2.
        2019.10 서비스 종료(열람 제한)
        「시설물의 안전 및 유지관리에 관한 특별법(이하 ‘시설물안전법’」에서는 제1종 및 제2종시설물에 대하여 안전점검 및 정밀안전진단을 통하여 시설물의 안전 및 유지관리를 실시하고 있으며, 종외 시설물의 노후화에 따른 안전관리 문제가 제기됨에 따라 제3종시설물을 지정하여 안전관리를 할 수 있도록 시설물안전법을 전부개정(’18.1.18.)하여 시설물 전반에 대한 안전관리를 하고 있다. ‘제3종시설물 안전등급 평가 매뉴얼(이하 ‘매뉴얼’)에서는 교량, 터널, 건축물 등 시설물에 대한 정기안전점검 기준 및 방법에 대하여 평가 등급기준을 3단계로 제시하고 있다. 본 연구에서는 기존 매뉴얼의 3단계 평가체계에서 5단계 평가체계로의 전환을 위해 평가등급별 기준을 도출하였으며, 현장적용성 검토를 통해 평가지 표의 적정성을 확보하고자 한다.
        3.
        2018.04 서비스 종료(열람 제한)
        We have identified the subway of structures as subway station users complained of vibrations from a structures when they walked through middle stairs of escalator. As a result of converting the vibration level to the conversion rate, it was measured at 3.846mm/s(82.7dB) on the B1st floor and 0.966mm/s(70.7dB) on the B2nd floor. These results are higher than the domestic standard of 65dB and lower than the international standard of under 5mm/s. It is felt well with the human body, but the structure is considered to be harmless. Therefore, it is deemded the structure is safe to usue. As the result of measuring the national frequency, the stairs on the B1st floor to be 3.01Hz and the stairs B2nd floor to be 5.36Hz. We consider that the users feel discomfort and anxiety on the B1st floor, where displacement and vibrations are higher.
        4.
        2017.06 KCI 등재 서비스 종료(열람 제한)
        Biomass adsorbents were prepared from fallen oak leaves. In the activation process for fallen oak leaves, various operating parameters such as the activation temperature (600-900°C), steam injection rate (5-15 cc/hr), and steam injection time (1- 3 hr) were adopted. For analyses of the manufactured adsorbent, various methods such as scanning electron microscope (SEM), measurements of the BET surface area and chemical composition analyses were adopted. Regarding major adsorption characteristics, the adsorption equilibrium capacity was measured using batch type experimental apparatus for various biomass adsorbents. The experimental result showed that the H2S adsorption equilibrium capacity of the adsorbent made from fallen oak leaves decreased as the activation temperature and steam injection rate increased for a given range.
        5.
        2017.04 서비스 종료(열람 제한)
        The condition assessment of the road tunnel is based on the judgment of the responsible engineer about the expansion joint. The evaluation result is divided into the span unit or the sheet unit when calculating the evaluation result. Therefore, it was divided into span units and sheet units and the actual difference was compared.
        6.
        2016.10 서비스 종료(열람 제한)
        In this study, ultrasonic detection device was applied to investigate connection part of concrete structure. Result of test, the internal void of connection part can be detected and it was possible to adopt the ultrasonic detection method to the maintenance of concrete structure.
        7.
        2013.11 서비스 종료(열람 제한)
        산업의 발전과 경제규모의 팽창에 따라 에너지소비가 크게 증가되는 가운데 대기오염물질배출이 크게 늘어나면서 심각한 환경문제를 야기하고 있다. 이중에서 황화수소(H₂S)는 계란 썩는 냄새가 나는 무색의 유독한 기체로서 인체의 위장이나 폐에 흡수되어 질식, 폐 질환, 신경중추마비 등을 발생시키고 있다. H₂S 가스는 폐기물 매립장, 석유 정제업, 펄프공업, 도시가스 제조업, 암모니아공업, 하수처리장 등 다양한 곳에서 발생하고 있으며, 이를 처리하기 위하여 심냉법, 흡수법, 막분리법, 흡착법 등 여러 가지 처리방법이 제시되었다. 본 연구에서는 실험실규모의 장치를 이용하여 낙엽부산물을 활용한 악취저감용 흡착소재개발을 위해 플라타너스 낙엽을 대상으로 탄화, 스팀활성처리등의 과정을 거쳐 흡착제를 제조하였으며, BET분석, SEM등을 이용한 물성분석과 회분식의 흡착평형실험을 통한 흡착특성을 고찰하였다. 실험결과, 플라타너스 건조낙엽을 활용하여 탄화 및 활성처리과정을 거치면서 얻을 수 있는 흡착제의 수율은 20 ~ 30%에 해당되는 것으로 밝혀졌다. 또한, 플라타너스 낙엽은 스팀을 이용한 활성처리 과정에서 온도가 증가할수록. 시간이 증가할수록 스팀-탄소 화학반응에 의해 내부기공이 커지면서 비표면적이 증가되는 것으로 밝혀졌다. 아울러, 플라타너스 낙엽을 소재로한 흡착제의 황화수소 평형흡착능은 활성탄 대비 80 ~ 90%의 우수한 성능을 보임으로써, 악취제거용 흡착소재로 활용성이 클 것으로 예상되었다.
        8.
        2013.11 서비스 종료(열람 제한)
        우리나라의 정수처리장에서 발생하는 정수슬러지는 2008년말 기준 1일 평균 1,800톤에 달하고 있으며, 정수장의 증설 및 상수도 보급율의 증가, 고도정수처리시설의 도입등으로 정수슬러지의 발생은 계속 증가되고 있다. 이들의 처리는 대부분 매립과 해양투기에 의존해 왔으나 기존 매립장의 포화에 따른 새로운 부지확보의 어려움, 침출수배출에 따른 민원발생등의 문제를 안고 있으며, 런던협약에 따라 2007년부터 해양투기가 금지됨에 따라 새로운 정수슬러지처리의 필요성이 고조되면서 친환경적이고 경제성있는 정수슬러지 재활용기술개발이 시급히 요청되고 있다. 본 연구에서는 정수슬러지를 활용한 악취저감용 흡착소재개발을 위해 정수슬러지를 대상으로 탄화, 스팀활성처리, 약품활성처리등 다양한 조건으로 슬러지흡착제를 제조하였으며, BET분석, SEM등을 이용한 물성분석과 회분식의 흡착평형실험을 통한 소재별 흡착특성을 고찰하였다. 실험결과, 정수슬러지는 탄화 및 스팀활성화과정을 통해 기공의 확대와 함께 비표면적이 증가되는 것을 알 수 있었고, 약품처리할 경우 정수슬러지 내부구조상에 약품의 함침으로 기공이 막히는 현상이 일어나 비표면적이 감소하는 것을 알 수 있었다. SEM분석을 통하여 건조된 정수원슬러지는 단단하면서 치밀한 표면구조를 보이지만, 탄화슬러지는 느슨하면서 헝클어진 표면구조를 나타내고, 석회석이 첨가된 경우에는 슬러지성분과 석회석이 물리적으로 혼합되어 표면에 산재해 있는 것으로 나타났다. 정수슬러지를 스팀이나 약품으로 활성처리할 경우 악취(황화수소)에 대한 흡착능이 10 ~ 35% 범위에서 향상되는 것으로 나타났으며, 전체적으로 활성탄대비 70 ~ 90%에 해당되는 비교적 양호한 평형흡착능을 갖는 것을 알 수 있었다.