This study aimed to apply rice flour Baromi 2 (B2) varieties developed by the Rural Development Administration in low-sugar baguette products. To achieve this, baguettes were produced using B2 at 10%, 20%, and 30% levels. As the content of B2 increased, the mixing time decreased, and the dough became sticky. Additionally, the dough fermentation ability was reduced. The finished products showed no significant difference in the external structure with varying B2 contents. However, the crust color containing B2 was darker than that of the control. In color value, the L* value decreased as the amount of added B2 increased, while the a* value and b* value increased. Furthermore, the sensory evaluation revealed that baguettes with a higher amount of B2 had a softer crumb and a crunchy crust, and with 20% substituted for B2, the sample obtained the highest score. From these results, it has been determined that B2 can substitute for up to 20% of wheat flour in bakery products.
최소 배지에 여러 아미노산을 첨가하여 배양시킨 Serratia marcescens ATCC 25419 세포 추출물에서 threonine dehydratase의 비활성을 조사한 결과 이소루신은 1∼4mM에서 효소의 비활성을 100∼140% 정도 증가시킨 반면 15∼30mM에서 25∼80% 정도 감소시켰다. 루신은 효소의 비활성을 1∼20mM에서 60%이상 감소시켰다. 한편, 발린은 효소의 비활성을 1∼4mM에서 20% 정도, 8∼10mM에서 10%정도 감소시켰으나 20mM에서 효소의 비활성을 원래대로 회복시켰다. 각 2mM 농도의 이소루신과 발린 그리고 이소루신과 루신은 효소의 비활성을 각각 75, 50%씩 증가시킨 반면 세 아미노산을 각각 2과 10mM씩 동시 첨가했을 경우에는 각각 25, 58%씩 감소시켰다. 글리옥실산은 효소의 비활성을 75%, 이마다졸, 피루브산, α-아미노부티르산 그리고 AMP는 모두 50%씩, 호모세린, α-케토글루타르산, α-케토부티르산 및 IPTG를 첨가했을 경우는 모두 25%씩 감소시켰다. cAMP는 표소의 비활성을 1∼2mM에서 10∼40%정도 감소시킨 반면 10mM에서 80% 증가시켰다. 이러한 결과들로부터 S. marcescens threonine dehydratase는 E. coli K-12 효소와는 다르게 낮은 농도의 이소루신에 의해 효소의 비활성이 증가되고, 높은 농도의 이소루신(10∼30mM)에 의해서는 감소되는 s등 이소루신 생합성 과정에서 조절 역할을 하는 것으로 생각된다.
Biomass-fired power plants produce electricity and heat by burning biomass in a boiler. However, one of the most serious problems faced by these plants is severe corrosion. In biomass boilers, corrosion comes from burnt fuels containing alkali, chlorine, and other corrosive substances, causing boiler tube failures, leakages, and shorter lifetimes. To mitigate the problem, various approaches implying the use of additives have been proposed; for example, ammonium sulfate is added to convert the alkali chlorides (mainly KCl) into the less corrosive alkali sulfates. Among these approaches, the high temperature corrosion prevention technology based on ammonium sulfate has few power plants being applied to domestic power plants. This study presents the results obtained during the co-combustion of wood chips and waste in a circulating fluidized bed boiler. The aim was to investigate the characteristics of pollution load in domestic biomass power plants with ammonium sulfate injection. By injecting the ammonium sulfate, the KCl content decreased from 68.9 to 5 ppm and the NOx were reduced by 18.5 ppm, but SO2 and HCl were increased by 93.3 and 68 ppm, respectively.
세기변조방사선치료와 입체적세기조절회전치료 시 조사체적과 선량 퍼짐 현상을 줄이기 위한 방법으로 조사 각도를 제한하는 부분 각도에 의한 회전치료 기능을 적용하여 표적체적과 주변 정상장기의 선량에 대해 입체조형방사선치료와 비교 분석하였다. 치료계획에 따른 표적체적의 선량분포는 통계적으로 유의한 차이를 확인할 수 없었으며, 폐의 5 Gy(V5) 체적에서 입체조형방사선치료 56.53%, 세기변조방사선치료 52.03%, 입체적세기조절회전치료 47.84%를 나타내어 유의한 차이를 나타내었다(CRT-IMRT p=0.035, CRT-VMAT p<0.001, IMRT-VMAT p<0.001). 10 Gy 체적(V10)에서는 입체조형방사선치료 35.12%, 세기변조방사선치료 34.04%, 입체적세기조절회전치료 33.28%를 보여, 입체조형방사선치료와 세기변조방사선치료(p=0.018), 입체적세기 조절회전치료(p=0.035)에서 유의한 차이를 나타내었으나 20 Gy 체적(V20)에서는 유의한 선량 차이를 확인 할 수 없었다. 심장의 평균선량과 20 Gy 체적은 치료계획에 따라 유의한 차이를 확인할 수 없었으나, 30, 40 Gy 체적은 입체적세기조절회전치료에서 37.16%, 22.46%를 나타내어 입체조형방사선치료와 비교에서 유의한 차이(p=0.028)를 보였다. 이와 같이 조사체적 감소에 따른 폐의 저 선량 체적(V5, V10)의 감소를 확인할 수 있었으며, 세기변조방사선치료와 입체적세기조절회전치료 시 조사 각도를 일부 제한함으로써 표적체적의 선량분포는 동일하게 유지함과 동시에 조사체적을 줄일 수 있었다. 이로 인해 폐의 선량 퍼짐 현상의 감소로부터 폐의 독성을 낮추는데 기여할 수 있을 것으로 사료된다.
스텐트 삽입술을 시행한 환자에게 ASL 방법 중 pCASL을 이용한 관류영상에서 나타난 인공물을 보고하고 이에 대한 해결방법을 제시하고자 한다. pCASL데이터는 구조적 이미지와 함께 스텐트를 피해 표지 펄스(labeling pulse)의 위치를 변경하여 획득하였다. 데이터는 ASLtbx를 이용하여 처리하였다. pCASL을 이용하여 관류영상을 획득하였을 때 기존의 표지 펄스(표지 간격(labeling gap) 24 mm)의 위치가 스텐트의 위치와 겹쳐져서 우뇌 조직의 신호강도가 비어있는 것처럼 나타났다. 스텐트를 피해 표지 펄스(표지 간격 15 mm)를 위치시킬 때 높은 신호강도의 영상을 획득 할 수 있었으며, 표지 펄스(표지 간격 170 mm)에서는 labeled 혈액이 영상절편에 도달하기 전에 이완이 되어 낮은 신호 강도의 영상을 획득 하였다. pCASL은 조영제를 사용하지 않기 때문에 안정적으로 반복측정이 가능하며 양질의 영상 획득을 위해서는 알맞은 영상획득인자와 방법들이 선택되어야 한다.
이 연구의 목적은 6 MV 광자 빔에 대한 광자극형광나노닷선량계(OSLnD)의 교정을 조사하는 데 있다. OSLnD의 선량반응 분석으로부터 선형 및 비선형 교정의 선량범위들은 결정을 하였다. 교정 및 교정식의 정확성을 평가하기 위하여 교정 및 품질관리선량계의 세트들은 만들어서 사용하였다. 교정들은 각각 0~300 cGy 및 20~1300 cGy 선량범위에서 선형 및 비선형적으로 수행하였다. 교정의 오차들은 선형 및 비선형 교정에 대하여 품질관리선량계들의 측정으로부터 각각 0.1% 이하로 얻었다. 이 연구는 6 MV 광자 빔에 대한 OSLnD의 교정식을 제공한다.
최근 건설 산업에서 CFRP는 재료적 장점들 때문에 구조물의 보강재로서 많이 사용되어 지고 있다. 본 논문에서 CFRP Plate가 보강된 철근콘크리트 보의 보강 효율과 설계 기초자료를 제공하려 한다. 정적 실험은 실험체의 파괴양상, 보강성능을 평가하였으며, 피로 실험은 처짐, 철근 변형률, CFRP Plate의 변형률을 분석하고, 에너지 소산과 보강성능을 평가하였다. 실험한 결과, 보강량이 증가할수록 단부 박리 파괴를 일으켰다. 그리고, 단부를 보강한 경우는 휨균열로 인한 박리파괴를 나타내는 파괴양상을 보였다. 피로 실험을 통하여 일정한 반복하중 횟수가 되면 처짐, 철근 변형률, CFRP Plate의 변형률 값이 일정한 값으로 수렴하였다. CFRP Plate가 보강된 보는 피로하중에 대해 사용성 확보가 가능했다.