검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 80

        21.
        2023.05 KCI 등재 서비스 종료(열람 제한)
        Eight years (2014–2021) of climate data were collected from an automatic weather observation system installed at the foot of Mt. Geumo in Chilgok, Gyeongbuk. Using these data, we investigated local bio-climatological indices (warmth index, WI; coldness index, CI; and effective accumulated temperature, EAT) of the mountain region adjacent to the Keimyung Dongyeong forest. The study area’s WI and CI were 109.3℃ and –11.3℃ per month, respectively, averaged across 8 years. These values are indicative of an evergreen broad-leaved forest in the warm temperate climate zone, suitable for cultivating sweet persimmons and figs. Additionally, EAT in Dongyeong was 2,113.7℃, averaged across 8 years, suitable for growing crops such as corn, soybean, and potato.
        22.
        2021.10 KCI 등재 서비스 종료(열람 제한)
        The relationship between night cooling rate and meteorological elements was investigated over the past five years (2016-2020), using weather data from the new (Daegu(143)) and old (Shinam(860)) Daegu Regional Meteorological Agency located in the suburban and urban regions, respectively. There was a correlation between the total daily amount of solar radiation (Stot) and the night cooling rate in the both regions. However, a higher correlation was observed at the new Daegu Regional Meteorological Agency station (Daegu(143)). In particular, data from the new Daegu Regional Meteorological Administration's observatory, which experiences a low thermal storage effect caused by artificial structures, showed a higher correlation between nighttime cooling and weather factors. The reason for this is that the lesser the heat storage effect caused by the artificial structures, the better the effect of surface radiation cooling on temperature reduction. These findings confirm that the correlation between night cooling and weather factors can be used to assess the impact of artificial structures in cities.
        23.
        2021.08 KCI 등재 서비스 종료(열람 제한)
        The characteristics of time changes in air temperature, DI (discomfort index) and WBGT (wet-bulb globe temperature) were investigated for inland city (daegu) and coastal city (pohang) of Gyeongbuk Province during the 2018 consecutive heat wave season. The time when the temperature dropped below 33℃ was around 19h in both regions. As such, the two regions were similar with respect to the time up to which the heatwave warning levels continued. However, the discomfort index (DI) was higher than 27 in Pohang. Most people feel unpleasant when an discomfort index of 27 or higher appears. The results indicated that Korea's night-time thermal environment during the summers is particularly poor in the southern coastal areas. WBGT began at 09:00 and lasted until 21:00, with a score of 31 or higher; this score, in principle, corresponded with the duration of outdoor activity in both regions. Therefore, it was found that outdoor work was at a level where all day long had to be stopped in both areas during the heat wave. Although time changes in temperature and WBGT were similar in both regions, Discomfort Index (DI) differed significantly. The difference refers to the fact that Pohang is strongly affected by the high heat capacity effect and the supply of water vapor from the sea.
        24.
        2020.07 KCI 등재 서비스 종료(열람 제한)
        In order to protect the lives and property of citizens, the central and local governments are responding by enacting municipal ordinances and regulations as the frequency of extreme weather conditions due to climate change increases and intensity increases gradually. Accordingly, the basic contents and strategies of domestic and foreign policies to cope with cold and heat waves were reviewed, referring to measures suitable for application to the Daegu metropolitan area. In addition, it is intended to provide a policy alternative to Daegu metropolitan area to minimize damage from extreme weather by identifying the current status, characteristics, and future prospects of extreme weather in Daegu metropolitan area. Since the damage caused by the cold wave in Daegu area is not as great as that of other regions, it is urgent to come up with cold wave measures for the health and transportation sectors, and to come up with measures against the heat wave as the damage caused by the heat wave is the most serious in the country. Also we will identify spatial characteristics so that the districts and counties with high vulnerability to extreme weather can be identified and implemented first, and present civic life-oriented facilities and civic action guidelines to overcome cold and heat waves.
        25.
        2018.03 KCI 등재 서비스 종료(열람 제한)
        We studied the warming effect induced by Photovoltaic(PV) power plants in rural areas during summer daytime using a simple analytical urban meteorological model. This analysis was based on observed meteorological elements and the capacity of the PV power plant was 10 MWp. The major axis length of the PV power plant was assumed to be 1km. Data of the necessary meteorological elements were obtained from a special meteorological observation campaign established for a over a PV power plant. We assumed that the wind flowed along the major axis of the PV power plant(1 km). As a result, the air temperature on the downwind side of the PV power plant was estimated to invrease by about 0.47 °C.
        26.
        2017.12 KCI 등재 서비스 종료(열람 제한)
        We compared the spatial distribution of several heat stress indices (the Wet-Bulb Globe Temperature(WBGT) index, Environmental Stress Index (ESI), and Modified Discomfort Index(MDI)) for the heat wave of June 6 ~August 26, 2016, in Daegu. We calculated the heat stress indices using data from the high density urban climate observation network in Daegu. The observation system was established in February. 2013. We used data from a total of 38 air temperature observation points (23 thermometers and 18 automatic weather stations). The values of the heat stress indices indicated that the danger level was very high from 0900-2000h in downtown Daegu. The daily maximum value of the WBGT was greater than or equal to 35℃ The differences in the heat stress indices from downtown and rural areas were higher in the daytime than at nighttime. The maximum difference was about 4 before and after 1400h, and the time variations of the heat stress indices corresponded well. Thus, we were able to confirm that the ESI and MDI can be substituted with the WBGT index.
        27.
        2017.09 KCI 등재 서비스 종료(열람 제한)
        We studied the distribution of air temperature using the high density urban climate observation network data of Daegu. The observation system was established in February 2013. We used a total of 38 air temperature observation points (23 thermometers and 18 AWSs). From the distribution of monthly averaged air temperatures, air temperatures at the center of Daegu were higher than in the suburbs. The daily minimum air temperature was more than or equal to 25℃ and the daily maximum air temperature was more than or equal to 35℃ at the elementary school near the center of Daegu. Also, we compared the time elements, which are characterized by the diurnal variation of surface air temperature. The warming and cooling rates in rural areas were faster than in urban areas. This is mainly due to the difference in surface heat capacity. These results indicate the influence of urbanization on the formation of the daily minimum temperature in Daegu.
        28.
        2016.11 KCI 등재 서비스 종료(열람 제한)
        From December 2014 to November 2015, an automatic weather system (AWS) was installed over a wide road of Daegu to continuously measure meteorological factors and surface temperature. We investigated the effective operating period of the clean-road system using the daily maximum and minimum air and asphalt surface temperatures, with the aim of creating an optimum thermal environment. The clean-road system was installed over a part of the broad way of Dalgubul(Dalgubul-Daero) by Daegu Metropolitan City in 2011. Until now, the clean-road system has been operated from the middle of April to the end of September. We assumed that it was desirable that the clean-road system could be operated when the discomfort index was above 55. In conformity with the conditions, we concluded that the optimum operation period of the clean-road system is from the end of March to about the middle of October.
        29.
        2016.08 KCI 등재 서비스 종료(열람 제한)
        The heat budget is investigated in the Gumi Reservoir of the Nakdong river. In warm climate season, solar radiation effects play a important role in the change of water temperature. The features of the surface heat balance are almost derived by the latent heat flux and the solar radiation flux. On the other hand, in cold climate season, change of heat stored in the water is mainly dominated by latent and sensible heat transfer between water and air, since flux of solar radiation and loss of outgoing long wave radiation balance approximately. For the annual averages, net flux of radiation, evaporation(latent heat) loss are dominant in the Gumi reservoir. The evaporation losses are dominant from spring to early winter. This means that the Gumi reservoir rolls like a lake of thermal medium or deep depth.
        30.
        2016.06 KCI 등재 서비스 종료(열람 제한)
        We investigated the local climatological characteristics of the mountain adjacent the Dongyeong herb garden in Chilgok. We established one set of automatic weather system (AWS) on a hill where development of herb garden is in progress. The observations were continued for 2 years(2013. 07-2015.06). In this study, we analyzed the observed data comparing the data of Gumi meteorological observatory (GMO). The results showed that the air temperature(relative humidity) of Dongyeong herb garden were lower(higher) than those of GMO. Especially the differences are more during warm climate season. It means that the gaps of thermal environment between two points are mainly caused by the evaporation effects of forest. In addition, we analyzed the warmth indices(warmth index and coldness index) with the observed air temperature. The warmth and coldness indices indicate about 107 and –12, respectively. The values correspond to warm temperature climate.
        31.
        2016.03 KCI 등재 서비스 종료(열람 제한)
        We analyzed the micro-meteorological characteristics during typical steam fog over the Gumi Reservoir of Nakdong river with the field observation data for recent 2 year(1 April 2013~31 March 2015) collected by the national institute of meteorological research, KMA. Steam fog occur when the cold drainage flows over the warm water surface. As the sensible and latent heat from water are provided to the air, the instability of lower atmosphere is increased. The resultant vertical mixing of warm, moist air near water surface and cold air aloft causes the formation of status cloud. The convection strengthened by radiative cooling of the upper part of the stratus causes the fog to propagate downward. Also, the temperature at the lowest atmosphere is increased rapidly and the inversion near surface disappear by these processes when the fog forms. The increase of wind speed is observed because the downward transportation of momentum is caused by vertical mixing.
        32.
        2016.02 KCI 등재 서비스 종료(열람 제한)
        In this study, changes in daily temperature range were investigated using daily maximum and minimum temperatures of Busan and Daegu for last 81 years (1934-2014), and also characteristics of daily temperature range and seasonal fluctuations by urbanization were examined. First, elapsing changes showed a lower decreasing trend in Busan (0.32℃) than Daegu (1.2 8℃) for last 81 years. Daily temperature range showed the highest rise in winter in both Busan and Daegu. Second, daily temperature range due to urbanization showed that Busan had a pronounced decreasing trend before urbanization meanwhile Daegu showed the same trend after urbanization. On seasonal changes, the results of Busan showed a decreasing trend in summer before urbanization, and in autumn after urbanization. For Daegu, the results showed a decreasing trend in spring before urbanization, and in winter after urbanization. Seasonal fluctuations of Busan showed little difference in the pre and post-urbanization, except in winter and summer. There was large difference in daily temperature range in winter after urbanization, and in summer before the urbanization. The results in Daegu showed that there was decreasing trend of daily temperature range in all seasons after urbanization.
        33.
        2016.02 KCI 등재 서비스 종료(열람 제한)
        We analyzed diurnal variations in the surface air temperature using the high density urban climate observation network of Daegu in summer, 2013. We compared the time elements, which are characterized by the diurnal variation of surface air temperature. The warming and cooling rates in rural areas are faster than in urban areas. It is mainly due to the difference of surface heat capacity. In addition, local wind circulation also affects the discrepancy of thermal spatiotemporal distribution in Daegu. Namely, the valley and mountain breezes affect diurnal variation of horizontal distribution of air temperature. During daytimes, the air(valley breeze) flows up from urban located at lowlands to higher altitudes of rural areas. The temperature of valley breeze rises gradually as it flows from lowland to upland. Hence the difference of air temperature decreases between urban and rural areas. At nighttime, the mountains cool more rapidly than do low-lying areas, so the air(mountain breeze) becomes denser and sinks toward the valleys(lowlands). As the result, the air temperature becomes lower in rural areas than in urban areas.
        34.
        2016.01 KCI 등재 서비스 종료(열람 제한)
        We analyzed the characteristics of fog formation in the Gumi Reservoir of Nakdong river with the field observation data for recent 2 years (1 April 2013~31 March 2015) collected by the national institute of meteorological research, KMA. In early morning, we frequently observe the steam rising from the water surface. The fog occurs from adding water vapor into the air. We call the fog as steam fog. Steam fogs occur when cold, dry air mixes with warm, moist air above a water surface. The steam fog appears mainly in autumn under the following conditions; (1) sensible heat is positive values (10~20 W/m2), (2) latent heat is more positive values (25~35 W/m2) than sensible heat, (3) cloudless nights with light winds (about 1.5 m/s), (4) under condition(3), mountainous winds easily blows into the reservoir.
        35.
        2015.12 KCI 등재 서비스 종료(열람 제한)
        In this study, the wind direction and the wind speed of the nearest temperature observations point of the National Weather Service was analyzed in order to investigate the rapid rise and drop of water temperature in the East Coast appeared after passing of the 2015 typhoon No. 9 and 11. Then the figures were simulated and analyzed using the WRF(weather research and forecast) model to investigate in more detailed path of the typhoon as well as the changes in the wind field. The results were as follows. A sudden drop of water temperature was confirmed due to upwelling on the East coast when ninth typhoon Chanhom is transformed from tropical cyclones into extra tropical cyclone, then kept moving eastwards from Pyongyang forming a strong southerly wind after 13th and this phenomenon lasted for two days. The high SST(sea surface temperature) is confirmed due to a strong northerly wind by 11th typhoon Nangka. This strong wind directly affected the east coast for three days causing the Ekman effect which transported high offshore surface waters to the coast. The downwelling occurred causing an accumulation of high temperature surface water. As a results, the SST of 15m and 25m rose to that of 5m.
        36.
        2015.11 KCI 등재 서비스 종료(열람 제한)
        In this study we were to explore the seasonal variation of water temperature distributions before and after weir construction at Gumi, Chilgok, Gangjung(Goryung), Dalsung in the Nakdong River using Landsat satellite images. Relationship between in-situ water temperature and radiance values of Landsat-5, 7, 8 satellite images showed high correlation. Seasonal variation of water temperature in Nakdong River showed that the fluctuation ranges of water temperature before weir construction were larger than those after weir construction. This indicated that the variation of water temperature is due to the difference of heat storage volume by weir construction and dredging work. In particular, the water temperature after weirs construction in autumn was 4-8 times lower than that before weirs construction. Water temperature after weir construction decreased in spring and summer at the downstream of Gumi weir and Gangjung(Goryung) weir, and the upstream of Dalsung weir. In autumn and winter, the water temperature after weir construction increased in the upstream and downstream of the whole weirs except upstream of Gumi weir. Relationship between water temperature and meteorological elements (air temperature, wind speed, sunshine, radiation) showed high correlation of above 94% in air temperature, and then radiation was high correlation before and after 65%.
        37.
        2015.09 KCI 등재 서비스 종료(열람 제한)
        To investigate thermal environment and effect of clean-road system over a broad way, we conducted the filed meteorological observation during 12~13 August 2014. The clean-road system was employed over a part of the broad way of Dalgubul(Dalgubul-Daero) by Daegu Metropolitan city in 2011. The clean–road system in general is operated two times(4 am, 2 pm) during summertime. In case of scorching alert, the system is operated 3 times a day(4 am, 2 pm and 4 pm). To evaluate the present thermal condition and the improvement effects due to the system, we analyzed the time variation of discomfort index and WBGT(wet-bulb and globe temperature). WBGT was more than 25 during 8 a.m. ~ 9 p.m. And discomfort index was more than 75 during 8 a.m. ~ 11 p.m. The thermal improvement effect of the clean-road system was restrictive during daytime.
        38.
        2015.06 KCI 등재 서비스 종료(열람 제한)
        Surface heat balance of the Gangjeong-Goryung Reservoir is analyzed for 12-17 August 2013. Each flux elements at the water surface is derived from the special field observations with application of an aerodynamical bulk method for the turbulent heat fluxes and empirical formulae for the radiation heat fluxes. The rate of heat storage in the reservoir is estimated by using estimated by surface heating rate and the vertical water temperature data. The flux divergence of heat transport is estimated as a residual. The features of the surface heat balance are almost decided by the latent heat flux and the solar radiation flux. On average for 12-17 August 2014 in the Gangjeong- Goryung Reservoir, if one defines the insolation at the water surface as 100 %, 94 % is absorbed in the reservoir; thereafter the reservoir loses about 30~50% by sensible heat, latent heat and net long-wave radiation. The residue of 50~80 % raises the water temperature in the reservoir or transported away by the river flow during the daytime.
        39.
        2014.12 KCI 등재 서비스 종료(열람 제한)
        Analyzing the observational data of volcanic activities around the northern part of Korean peninsula, the odds of volcano eruption increases continuously. For example, the cumulative seismic moment and frequence observed near Mt. Baekdu show a sudden increased values. In this study, predicting the diffusion of volcanic ash for two cases were carried out by using interactive realtime simulator, which was developed during last 2 years as a research and development project. The first case is Sakurajima volcano (VEI=3) erupted in August 2013. The second case is assumed as the volcanic eruption at Mt. Baekdu (VEI=7) under landing circumstance of typhoon Maemi (August 2003) in Korean peninsula. The synoptic condition and ash diffusion for the two cases were simulated by WRF(Weather Research and Forecast) model and Lagrangian dispersion model, respectively. Comparing the simulated result of the first case (i.e., Sakurajima volcano) with satellite image, the diffusion pattern show acceptable result. The interactive realtime simulator can be available to support decision making under volcanic disaster around East Asia by predicting several days of ash dispersion within several minutes with ordinary desktop personal computer.
        40.
        2014.12 KCI 등재 서비스 종료(열람 제한)
        To improve air quality around a broad way, Daegu Metropolitan city employed the clean-road system at a part of the broad way of Dalgubul (Daigubul-daero) in 2011. The clean–road system in general is operated two times (4 am, 2 pm) during summertime. In case of scorching alert, the system is operated 3 times a day (4 am, 2 pm and 4 pm). To evaluate the effect of air quality improvement due to the system, we analyzed the time variation of monthly mean particulate matter (PM10) concentration in recent 3 years (2011-2013). The improvement of air quality was estimated at about 5~15 % under the system.
        1 2 3 4