We examine a single machine scheduling problem with step-improving jobs in which job processing times decrease step-wisely over time according to their starting times. The objective is to minimize total completion time which is defined as the sum of completion times of jobs. The total completion time is frequently considered as an objective because it is highly related to the total time spent by jobs in the system as well as work-in-progress. Many applications of this problem can be observed in the real world such as data gathering networks, system upgrades or technological shock, and production lines operated with part-time workers in each shift. Our goal is to develop a scheduling algorithm that can provide an optimal solution. For this, we present an efficient branch and bound algorithm with an assignment-based node design and tight lower bounds that can prune branch and bound nodes at early stages and accordingly reduce the computation time. In numerical experiments well designed to consider various scenarios, it is shown that the proposed algorithm outperforms the existing method and can solve practical problems within reasonable computation time.
The genus Peromitra Enderlein is a small group of phorid flies, including two European parasitic species known to parasitize larval bibionid flies. In this study, specimens of the Peromitra species collected from South Korea are examined morphologically on the basis of characteristics on ocellar region, leg chaetotaxy and hypopygium. As a result, four species are described new to science and two species, viz. P. fimbriata and P. multisetalis are newly recorded from South Korea. Photographs of diagnostic characters and a key to males of South Korean species are provided.
The genus Conicera Meigen is a group of necrophagous phorid flies mostly associated with carrion, including C. tibialis, commonly known as the “coffin fly” that breeds in buried corpses. In this study, specimens of the Conicera species collected from South Korea are examined morphologically on the basis of characteristics on male antennae, sensory organ on midfemora, and left and right surstyli on hypopygium. As a result, five species, viz. C. dauci, C. gracilis, C. orientalis, C. pacifica, C. quadrata are newly recorded from South Korea. Photographs of diagnostic characters, a distribution map and a key to males of South Korean species are provided.
In gamma-ray spectrometry for volume samples, the self-attenuation effect should be considered in the case of differences in chemical composition and density between the efficiency calibration source for quantitative analysis of sample and the sample actually measured. In particular, the lower the gamma-ray energy, the greater the gamma-ray attenuation due to the self-attenuation effect of the sample. So, the attenuation effect of low-energy gamma-rays in the sample should be corrected to avoid over- or under-estimation of its radioactivity. One of the most important factors in correcting the self-attenuation effect of the sample is the linear attenuation coefficient for the sample, which can be directly calculated using a collimator. The larger the size of the collimator, the more advantageous it is to calculate the linear attenuation coefficient of the sample, but excessive size may limit the use of the collimator in a typical environmental laboratory due to its heavy weight. Therefore, it is necessary to optimize the collimator size and structure according to the measurement environment and purpose. This study is to optimize a collimator that can determine the effective linear attenuation coefficient of low-energy gamma-rays, and verify its applicability. The overall structure of the designed collimator was optimized for gamma-ray energy of less than 100 keV and cylindrical plastic bottle with diameter of 60 mm and a height of 40 mm. The materials of optimized collimator consisted of tungsten. Acryl and acetal were used to form the housing of the collimator, which fixes the central axis of the bottle, collimator and point-like source. In addition, using the housing, the height of the tungsten is adjusted according to the height of the sample. For applicability evaluation of the optimized collimator, IAEA reference material in solid form were used. The sample was filled in the bottle with heights of 1, 2, 3 and 4 cm respectively. Using the collimator and point-like source of 210Pb (46.5 keV), 241Am (59.5 keV), and 57Co (121.1 keV), the linear attenuation coefficient and the radioactivity for the samples were calculated. As a result, to calculate the linear attenuation coefficient using the optimized collimator, a relatively high sample height is required. However, the optimized collimator can be used to determine the linear attenuation coefficients of low-energy gamma-rays for the self-attenuation correction regardless of the sample height. It is concluded that the optimized collimator can be useful to correct the sample selfattenuation effect.
컴퓨터 성능의 발전으로 빅데이터의 효율적인 사용이 가능해지면서, 심층 학습(deep learning)은 다양한 의료 분야에 활용할 수 있는 핵심적인 인공지능(artificial intelligence, AI) 기법으로 각광받고 있다. 이에 본 종설은 뇌종양 진단과 치료에 사용되는 자기공명영상(magnetic resonance imaging, MRI)의 심층 학습 기법을 소개하고자 하였다. 먼저 국내 AI의 의료 분야 도입의 동향을 분석하고, 이를 바탕으로 MRI를 활용한 뇌종양의 진단과 치료에 적용할 수 있는 심층 학습 기법과 그 결과들을 기술하였다. 뇌종양 진단과 치료 시, 심층 학습을 이용한 최근 사례는 영상 분류, 영상 품질 개선, 영상 분할로 나타났으며, 질병의 진단과 치료에 적용할 수 있는 객관적이고 높은 성능 수치를 나타내면서 그 유용성을 확인 할 수 있었다. 종합하자면, 심층 학습은 질병의 진단과 치료에 적용할 수 있는 유용한 지표이며, AI 역량을 지닌 의료진의 지도하에 점진적인 도입이 이뤄진다면 질병의 진단과 치료에 큰 도움을 주는 훌륭한 소프트웨어로 활용될 것으로 여겨진다. 본 종설이 심층 학습을 이해할 때 많은 도움이 되길 바라며, 향후 관련 연구를 수행할 때 가이드라인으로 활용될 것을 기대 한다.
In this work, we introduce a 100 kW class mobile plasma melting system designed for non-combustible radioactive wastes treatment. To ensure mobility, the designed system consists of two 24-ft commercial containers, each in charge of the plasma utilities and melting process. In the container for plasma utilities, a 100 kW class DC power supply is installed together with a chiller and gas supply system whereas the container for melting process has a transferred type arc melter as well as off-gas treatment system consisting of a heat exchanger, filtrations, scrubber and NOx removal system. As a heat source for a transferred type arc melter, we adopted a hollow electrode plasma torch with reverse polarity discharge structure. Detailed design for a 100 kW class mobile plasma melting system will be presented together with the main specifications of the components. In addition, the basic performance data of the melting system is also presented and discussed.
자기공명영상(MRI) 장비의 조영제로 흔히 사용되는 가돌리늄(Gd)은 매우 안정된 상태로 하수처리과정에서 거의 제거되지 않고 수환경으로 유입된다고 알려져 있다. 따라서 본 연구에서는 세 가지의 공법으로 하수처리를 하는 부산 수영 하수처리장에서 채취한 하수 시료의 공정별 용존 희토류 원소의 제거율 및 수환경으로 배출되는 인위적 기원 Gd (Gdanth)의 배출량을 평가하고자 하였다. 용존 희토류 원소는 공정별 처리 단계에 따라 무거운 희토류 원소(Tb-Lu)에 비 해 가벼운 희토류 원소(La-Eu)에서 농도가 감소하는 경향을 보였다. 또한 일부 시료에서 나타난 음의(negative) Sm anomaly (<1)는 생물학적 제거 과정에서 Sm이 입자나 인산염과 흡착되어 함께 제거되었을 가능성을 시사한다. 모든 시 료에서 양의(positive) Gd anomaly (149±50, n=9)를 보였으며, 공정별로 측정된 Gd의 총 농도 중 Gdanth은 약 97% 이 상을 차지하는 것으로 나타났다. 이는 하수처리과정에서 Gdanth 이 거의 제거되지 않고 수영강 하류로 배출된다는 것을 의미한다. 일별 처리용량을 고려하여 각 공정에서 배출되는 Gdanth의 배출량은 259 mmol/day로 추정할 수 있다. 본 연 구의 결과는 하수처리장을 통해 수영만 연안으로 Gdanth이 지속적으로 배출될 것으로 예상되며, 향후 Gd의 중장기적인 관측이 필요함을 시사한다.
2-에티닐-N-노나노일피리디늄 클로라이드를 치환기로 갖는 새로운 폴리아세틸렌 유도체를 합성하였다. 반응초기에 2-에티닐피리딘과 노나노일 클로아이드의 4차염화반응으로 생성된 단량체 종인 2-에티닐-N-노나노일피리디늄 클로라이드 는 별도의 촉매 없이도 중합반응이 잘 진행되었으며, 그결과 89%의 수율로 폴리아세틸렌계 이온성 공액구조 고분자를 합 성할 수 있었다. 여러 가지 분석장비를 이용하여 고분자 구조를 분석한 결과 설계한 치환기를 갖는 폴리아세틸렌 유도체 가 합성되었음을 확인할 수 있었다. 본 고분자는 메탄올, DMF, DMAc, DMSO, NMP 와 같은 극성 용매에 완전히 용해하였 으며, 이온성 측쇄 부분을 갖는 특성으로 다루는 과정에서 공기중 수분을 흡수하는 경향이 강했다. 고분자의 광흡수 및 전 기화학적 특성을 측정하고 분석하였다. 본 고분자는 산화-환원 피크 사이에 비가역적 전기화학적 거동을 보였으며 다른 이 온성 공액구조 고분자의 경우와 유사하게 전기화학적 스캔수를 증가한 실험에서 50회까지도 안정된 산화-환원 거동을 보 였다.
대기오염물질 감축에 대한 국제적인 인식이 높아짐에 따라 친환경 선박에 대한 수요가 증가하고 있어 각국에서 전기추진선박 개발을 활발하게 수행하고 있다. 현재 전기추진선박에 대해서는 주로 전기추진시스템 및 전동기 연구를 주로 수행하고 있으며, 선박 관점 에서 전기추진시스템 및 배터리의 탑재를 고려한 국내 연안 차도선 개념설계 연구는 수행된 바가 없다. 본 연구에서는 배터리 차량 기반의 이동식 전원공급시스템을 주전원으로 하는 순수전기추진차도선의 개념설계 과정에서의 주요 고려사항에 대하여 검토하였다. 100척 이상의 국내 연안차도선의 제원을 분석하여, 요구사항 만족을 위한 선박의 주요제원 선정과 이동식 배터리 차량 탑재를 고려한 비손상, 손상 복원성능 검토를 수행하였고, 개념설계 과정에서 발생하는 문제의 원인분석을 통해 해결방안을 모색하였다.
This study investigated the residue of tulathromycin (TLM) on the lung tissue of pigs intramuscularly injected with 2.5 mg/kg body weight as a single dose. Nine healthy cross swine were intramuscularly injected with the drug. Three treated animals were arbitrarily selected to be sacrificed at 7, 10 and 14 days after treatment. TLM residue concentrations in lung tissue were determined using liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). The drug was extracted from lung samples using acetonitrile followed by clean-up with n-hexane. The analyte was separated on a Hypersil GOLDTM liquid chromatography column using 0.1% formic acid in deionized distilled water and acetonitrile. The correlation coefficient (R2) of the calibration curve was 0.9981, and the limits of detection and quantification were 10 and 50 μg/kg, respectively. Recoveries at three spiking levels ranged between 95.0-98.2%, and relative standard deviations were less than 3.95%. In TLM-treated group, the concentration of TLM on 7, 10 and 14 days post-treatment was 627.3, 496.9, 259.1 μg/kg, respectively. The developed method is sensitive and reliable for detection of TLM in porcine lung tissues. In addition, it can detect below the maximum residue limits in animal-derived food products destined for human consumption.
Basaloid squamous cell carcinoma (BSCC) is a rare and aggressive variant of squamous cell carcinoma arising in various anatomical sites. This article describes a case history of BSCC of the floor of mouth with mandibular involvement, and further discusses the appropriate management of such case with reference to the literature review. A 52-year-old male patient was referred to our clinic from another university hospital. Segmental mandibulectomy with supraomohyoid neck dissection and mandible reconstruction with left fibular free flap under general anesthesia was performed, followed by radiotherapy. Histopathological examination on the tumor lesion revealed features of squamous cell carcinoma with comedo-type necrosis. A diagnosis of BSCC was given by the oral pathology specialist. Basaloid squamous cell carcinoma (BSCC) is a biphasic variant of SCC with both basaloid and squamous cell histology. A recent report showed that there is no significant difference in the prognosis. Due to the lack of accumulated research, close follow-up and continuous research are deemed necessary. Treatment that focuses on the stage of the tumor is appropriate. A periodic follow-up observation is also very important due to the occurrence of distant metastasis to the lungs.
본 연구에서는 원자력 사고 또는 방사선 비상 시 지표면에 침적될 수 있는 감마선방출 핵종의 방사능을 신속하게 평가하기 위해 이용될 수 있는 NaI(Tl), LaBr3(Ce) 및 CeBr3 섬광검출기의 성능을 비교 평가하였다. 검출성능은 최소검출가능방사능 (MDA, Minimum Detectable Activity)을 통해 평가하였으며, 각 검출기의 지표면 침적 감마선방출 핵종에 대한 검출효율은 수학적 모델링과 점선원을 이용하여 반실험적으로 산출하였다. MDA 평가를 위한 백그라운드 감마선에너지스펙트럼은 비교적 넓고 평탄한 초지에서 측정되었으며, 원자력 사고 시 방출될 수 있는 주요 핵종에 대한 각 검출기의 MDA를 산출하였다. 그 결과 일반 환경방사능 준위에서 지표면 침적 감마핵종에 대한 각 검출기의 MDA 크기는 대체로“NaI(Tl)> LaBr3(Ce)> CeBr3”로 평가되었으며, 백그라운드 준위가 유사한 에너지 영역에서는 분해능이 가장 우수한 LaBr3(Ce)에서 최소 값을 보였다. 이는 관심 핵종의 감마선에너지 영역에 대한 각 검출기의 자체 및 측정 환경 백그라운드, 측정 효율, 그리고 에너지 분해능 특성을 바탕으로 비교 분석되었다.