검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 563

        41.
        2023.05 구독 인증기관·개인회원 무료
        The organic complexing agents such as ethylenediaminetetraacetic acid (EDTA), nitrilotriacetic acid (NTA), and isosaccharinic acid (ISA) can enhance the radionuclides’ solubility and have the potential to induce the acceleration of radionuclides’ mobility to a far-field from the radioactive waste repository. Hence, it is essential to evaluate the effect of organic complexing agents on radionuclide solubility through experimental analysis under similar conditions to those at the radioactive waste disposal site. In this study, five radionuclides (cesium, cobalt, strontium, iodine, and uranium) and three organic complexing agents (EDTA, NTA, and ISA) were selected as model substances. To simulate environmental conditions, the groundwater was collected near the repository and applied for solubility experiments. The solubility experiments were carried out under various ranges of pHs (7, 9, 11, and 13), temperatures (10°C, 20°C, and 40°C), and concentrations of organic complexing agents (0, 10-5, 10-4, 10-3, and 10-2 M). Experimental results showed that the presence of organic complexing agents significantly increased the solubility of the radionuclides. Cobalt and strontium had high solubility enhancement factors, even at low concentrations of organic complexing agents. We also developed a support vector machine (SVM) model using some of the experimental data and validated it using the rest of the solubility data. The root mean square error (RMSE) in the training and validation sets was 0.012 and 0.016, respectively. The SVM model allowed us to estimate the solubility value under untested conditions (e.g., pH 12, temperature 30°C, ISA 5×10-4 M). Therefore, our experimental solubility data and the SVM model can be used to predict radionuclide solubility and solubility enhancement by organic complexing agents under various conditions.
        42.
        2023.05 구독 인증기관·개인회원 무료
        In response to a regulatory mandate, all nuclear licensees are obligated to establish an information system that can provide essential information in the event of a radiation emergency by connecting the monitoring data of the Safety Parameter Display System (SPDS) or equivalent system to the Korea Institute of Nuclear Safety (KINS). Responding to this responsibility, the Korea Atomic Energy Research Institute (KAERI) has established the Safety Information Transmission System (SITS), which enables the collection and real-time monitoring of safety information. The KAERI monitors and collects safety information, which includes data from the HANARO Operation Work Station (OWS) and the HANARO & HANARO Fuel Fabrication Plant (HFFP) Radioactivity Monitoring System (RMS), and the Environmental Radiation Monitoring System (ERMS) & meteorological data. Currently, the transmission of this safety information to the AtomCARE server of the KINS takes place via the SITS server located in the Emergency Operations Facility (EOF). However, the multi-path of transmission through SITS has caused problems such as an increase in data transmission interruptions and errors, as well as delays in identifying the cause and implementing system recovery measures. To address these issues, a new VPN is currently being constructed on the servers of nuclear facilities that generate and manage safety information to establish a direct transmission system of safety information from each nuclear facility to the AtomCARE server. The establishment of a direct transmission system that eliminates unnecessary transit steps is expected to result in stable information transmission and minimize the frequency of data transmission interruptions. As of the improvement progress, a security review was conducted in the second and third quarters of 2022 to evaluate the security of newly introduced VPNs to the nuclear facility server, and based on the results of the review, security measures were strengthened. In the fourth quarter of 2022, the development of a direct transmission system for safety information began, and it is scheduled to be completed by the fourth quarter of 2023. The project includes the construction of the transmission system, system inspection, and comprehensive data stability testing. Afterward, the existing SITS located in the EOF will be renamed as the Safety Information Display System (SIDS), and there are plans to remove any unused servers and VPNs.
        43.
        2023.05 구독 인증기관·개인회원 무료
        Decommissioning plan of nuclear facilities require the radiological characterizations and the establishment of a decommissioning process that can ensure the safety and efficiency of the decommissioning workers. By utilizing the rapidly developed ICT technology, we have developed a technology that can acquire, analyze, and deliver information from the decommissioning work area to ensure the safety of decommissioning workers, optimize the decommissioning process, and actively respond to various decommissioning situations. The established a surveillance system that monitors nuclide inventory and radiation dose distribution at dismantling work area in real time and wireless transmits data for evaluation. Developed an evaluation program based on an evaluation model for optimizing the dismantling process by linking real-time measurement information. We developed a technology that can detect the location of dismantling workers in real time using stereovision cameras and artificial intelligence technology. The developed technology can be used for safety evaluation of dismantling workers and process optimization evaluation by linking the radionuclides inventory and dose distribution in dismantling work space of decommissioning nuclear power plant in the future.
        44.
        2023.05 구독 인증기관·개인회원 무료
        The treatment of waste generated during operation as a part of preparation for decommissioning is coming to the fore as a pending issue. Non-fuel waste stored in the spent fuel pool (SFP) of PWRs in Korea includes Dummy fuel, damaged fuel rod storage container, reactor vessel specimen cask, spent in-core instrumentation, spent control element assemblies, spent neutron source assemblies, burnable poison rods, etc. In order to treat such waste, it is necessary to classify radioactive waste level and analyze kinds of nuclide in accordance with legal requirements. In order to solve the problem, the items that KHNP-CRI is trying to conduct like followings. First, KHNP-CRI will identify the current status of non-fuel waste stored in the SFP of all domestic nuclear power plants. In order to consider the treatment of non-fuel waste, it is essential to know what kind of items and how many items are stored in the SFP. Second, to identify the dimension and characteristics of non-fuel waste stored in the SFP would be conducted. The configuration of non-fuel waste is important information to handle them. Third, the way to handle non-fuel waste would be deduced including analysis of their dimension, whether the equipment should be developed to handle each kind of non-fuel waste or not, how to transport them. In order to classify radioactive waste level and analyze the nuclide for the non-fuel waste, handling tools and the cask to transport them into the facility which nuclide analysis is able to be performed would be required. Fourth, the nuclide analysis technology would be identified. Also, domestic holding technology would be identified and which technology should be developed to classify the radioactive waste level for the non-fuel waste would be deduced. This preliminary study will provide KHNP-CRI with the insight for the nuclide analysis technology and future work which is following action for the non-fuel waste. Based on the result of above preliminary study, the feasibility of the research for the treatment of non-fuel waste would be evaluated and research plan would be established. In conclusion, the treatment of non-fuel waste stored in the spent fuel pool of domestic PWR should be considered to prepare the decommissioning. KHNP-CRI will identify the quantity, the dimension and kinds of non-fuel waste in the SFP of domestic PWR. Also, the various nuclide analysis technology would be identified and the technology which should be developed would be defined through this preliminary study.
        45.
        2023.05 구독 인증기관·개인회원 무료
        Bentonite has been considered as a potential buffer material in the engineering barriers of highlevel radioactive waste disposal systems. The intrusion of groundwater and heat from the waste change the temperature of the bentonite, which can alter the hydraulic properties of the bentonite. In this study, temperature effects on permeability were observed in two Ca-type bentonites. Laboratory tests were conducted on two types of block that were compacted using Korean Gyeongju bentonite and bentonil-WRK at different dry densities. Permeability tests were conducted at three different temperatures, namely 30°C, 60°C, and 90°C, using deionized water. Moreover, comparison between two Ca-type bentonites is carried out.
        46.
        2023.05 구독 인증기관·개인회원 무료
        An important goal of dismantling process is the disassembling of a spent nuclear fuel assembly for the subsequent extraction process. In order to design the rod extractor and cutter, the major requirements were considered, and the modularization design was carried out considering remote operation and maintenance. In order to design the rod extractor and cutter, these systems were analyzed and designed, also the concept on the rod extraction and cutting were considered by using the solid works tool. The main module consists of five sub-modules, and the function of each is as follows. The clamping module is an assembly fixing module using a cylinder so that the nuclear fuel assembly can be fixed after being placed. The Pusher module pushes the fuel rods by 2 inches out of the assembly to grip the fuel rods. The extraction module extracts the fuel rods of the nuclear fuel assembly and moves them to the consolidation module. The consolidation module collects and consolidates the extracted fuel rods before moving them to the cutting device. And the support module is a base platform on which the modules of the main device can be placed. The modules of level 2 can be disassembled or assembled freely without mutual interference. For the design of fuel rods cutter, the following main requirements were considered. The fuel rod cut section should not be deformed for subsequent processing, and the horizontally mounted fuel rods must be cut at regular intervals. The cutter should have the provision for aligning with the fuel rod, and the feeder and transport clamp should be designed to transfer the fuel rods to the cutting area. The main module consists of 6 sub-modules, and function of each is as follows. The cutting module is a device that cuts the fuel rods to the appropriate depth for notching. The impacting module is a device that impacts the fuel rods and moves them to the collection module. The transfer module is a device that moves the fuel rods to the cutting module when the aligned fuel rods enter the clamp module. The clamping module is a device to clamp the fuel rods before moving them to the cutting module. The collection module is a container where the rod-cuts are collected, and the support module is a base platform on which the modules of the main device can be placed. The module of level 3 can be disassembled or assembled after the cutting module of level 2 is installed, and the modules of level 2 can be disassembled or assembled freely without mutual interference.
        47.
        2023.05 구독 인증기관·개인회원 무료
        In this paper, a basic study was conducted to observe the temperature inside the tube according to the heating temperature of the tube furnace. In a tube furnace, a tube is inserted, and the air space outside the tube is heated to increase the temperature of the gas inside the tube through conduction of the tube. Tube furnaces are widely used in research to capture volatile nuclides. In this case, a volatile nuclide capturing filter is inserted inside the tube, and an appropriate temperature is required to capture it. Since the tube furnace heats the air space outside the tube to the target temperature, a difference from the temperature inside the tube occurs. In particular, if a flow of gas occurs inside the tube, a larger temperature difference may occur. In order to confirm this temperature difference, an experimental device was constructed, and basic data was produced through several experiments. The following studies were conducted to produce data. First, the temperature of the air layer of the heating unit and the temperature inside the tube were measured in real time in the absence of gas flow inside the tube. Second, the temperature of the air layer of the heating unit and the temperature inside the tube were measured in real time while air having a certain temperature was flowing inside the tube. As a result of the experiment, when there is no flow inside the tube, when the heating target temperature is low, the temperature inside the tube is significantly lower than the target temperature, and when the target temperature is high, the temperature inside the tube approaches the target temperature. It was found that when there is about 20°C air flow inside the tube, the temperature inside the tube is significantly lowered even if the heating target temperature is high. In the future, additional research on changing the temperature of the gas flowing inside the tube will be conducted, and the results of this study are expected to greatly contribute to the design of a tube furnace that captures volatile nuclides.
        60.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Influenza A viruses (IAVs) are members of the family Orthomyxoviridae and genus Orthomyxovirus. Avian and mammalian species are the host of IAVs, which includes humans and dogs. Canine influenza virus (CIV) is an emerging pathogen that causes severe and acute respiratory diseases in dogs. This study monitored the antigen and antibody against CIV in dogs in the Republic of Korea (ROK) from 2016 to 2021. One thousand and seventy-two nasal swabs and 1,545 blood samples were collected from animal hospitals and animal shelters. Five nasal swabs in 2017 and seven in 2018 from stray dogs were positive for CIV according to RT-PCR. The prevalence of H3N2 CIV ranged from 9.5% to 24.8%, according to the hemagglutination inhibition (HI) assay. On the other hand, none of the serum samples from 2018 to 2021 showed seropositivity against the avian H5, H7, and H9 viruses. The HI titers for H3N2 ranged from 16 to 512. The distribution of HI titer 16–32 was 57.6% in seropositive samples. The pet dogs were vaccinated against CIV, but the stray and military dogs were unvaccinated. In 2017 and 2018, the seroprevalence of CIV in stray dogs was higher than in the other years, and viral RNA was detected in nasal swabs. It may mean previous exposure of stray dogs to CIV. With the increasing number of pet dogs and the close contact between humans and dogs, canines could serve as an intermediate host for transmitting IAVs to humans. Therefore, continuous surveillance of CIV is needed for public health and the potential emergence of novel zoonotic viruses.
        4,000원
        1 2 3 4 5