검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 67

        1.
        2023.11 구독 인증기관·개인회원 무료
        In nuclear power plant environments, the analysis of gamma-emitting waste materials with complex shapes can be challenging. ISOCS (In-Situ Objective Counting System) is employed to measure the gamma-emitting radionuclide concentrations. However, it is crucial to validate the accuracy of ISOCS measurements. This study aims to validate the accuracy of ISOCS measurement results for spent filters. The ISOCS measurement process begins with modeling and efficiency calculations of the target spent filters using ISOCS software. ISOCS offers the advantage of direct measurement assessment by incorporating shielding materials and collimators into the detector efficiency calculation during the modeling process, without the need for separate efficiency correction sources. To validate the accuracy of ISOCS measurement results, the measured radioactivity values were used as input data for the MicroShield computer code to derive dose rates. These dose rates were then compared to the dose rates measured on-site, confirming the reliability of ISOCS measurements. In the field, ISOCS gamma measurements and surface dose rates were measured for three Cavity filters and four RCP Seal Injection filters. The measured dose rate for the Cavity filters was around 270 Svhr, and the computed values using MicroShield showed an error of approximately 12%. Despite modeling and calculation errors in computer analysis and potential uncertainties in the measurement environment and instrument, the computed values closely matched the measured values. However, the measured dose rate for the RCP Seal Injection filters ranged 2.9~8 Svhr, which is very low and close to background levels. When compared to the results of computer analysis, an error ranging from 27% to 97% was observed. It is concluded that validating the accuracy in the low dose rate range close to background levels is challenging through a comparison of calculated and measured dose rates.
        2.
        2023.10 구독 인증기관·개인회원 무료
        Until now, in case of Palaearctic region, only one species, Nesendaeus monochrous in this genus was recorded from China. but the biology and life cycle are not clearly known, yet. This species collected from the bud of Glochidion chodoense in Korea for the first time and closely related to Heterochyromera imerodeus Kojima & Morimoto which was recorded only in Japan,. But Nesendaeus monochrous is easily distinguishable from H. imerodeus by the relatively longer elytra with bisinuately round apices. Heterochyromera imerodeus Kojima & Morimoto can be found from Eurya emarginata and Glochidion obovatum in Japan. So, this two species are closely related each other and need more taxonomic study about the generic synonymy or changing the generic position.
        3.
        2023.05 구독 인증기관·개인회원 무료
        Wolsong unit 1, the first PHWR (Pressurized Heavy Water Reactor) in Korea, was permanent shut down in 2019. In Korea, according to the Nuclear Safety Act, the FDP (Final Decommissioning Plan) must be submitted within 5 years of permanent shutdown. According to NSSC Notice, the types, volumes, and radioactivity of solid radioactive wastes should be included in FDP chapter 9, Radioactive Waste Management, Therefore, in this study, activation assessment and waste classification of the End shield, which is a major activation component, were conducted. MCNP and ORIGEN-S computer codes were used for the activation assessment of the End shield. Radioactive waste levels were classified according to the cooling period of 0 to 20 years in consideration of the actual start of decommissioning. The End shield consists of Lattice tube, Shielding ball, Sleeve insert, Calandria tube shielding sleeve, and Embedment Ring. Among the components composed for each fuel channel, the neutron flux was calculated for the components whose level was not predicted by preliminary activation assessment, by dividing them into three channel regions: central channel, inter channel, and outer channel. In the case of the shielding ball, the neutron flux was calculated in the area up to 10 cm close to the core and other parts to check the decrease in neutron flux with the distance from the core. The neutron flux calculations showed that the highest neutron flux was calculated at the Sleeve insert, the component closest to the fuel channel. It was found that the neutron flux decreased by about 1/10 to 1/20 as the distance from the core increased by 20 cm. The outer channel was found to have about 30% of the neutron flux of the center channel. It was found that no change in radioactive waste level due to decay occurred during the 0 to 20 years cooling period. In this study, activation assessment and waste classification of End Shield in Wolsong unit 1 was conducted. The results of this study can be used as a basis for the preparation of the FDP for the Wolsong unit 1.
        4.
        2023.05 구독 인증기관·개인회원 무료
        CANDU Spent Fuel (CSF) dry storage system, SILO, has been operated from 1992 at Wolsung under 50 year operating license. As of 2023, this system has been operated for over 30 years and its licensed remaining operation time is less than 20 years. When it faces the final stage of operation, it has only two options; moving to a centralized away-from-reactor storage or extending its license atreactor. These two options have an inevitable common duty of confirming the CSF integrity by a “demonstration test”. Since the degradation of CSF and structural materials in the SILO are critically dependent on temperature, two important goals of the ‘DEMO test’ were set as follows. 1. Design of ‘DEMO SILO’: Development of internal monitoring technology by transforming SILO design. 2. Accurate measurement and evaluation of the three-dimensional temperature distribution in the ‘DEMO SILO’ Based on operating real commercial SILO dimension, a conceptual “DEMO SILO” design has been developed from 2022. Because, unlike with commercial Silo, ‘Demo Silo’ must be disassembled and assembled, and have penetration holes. Safety evaluation technologies like structural, thermal and radiation protection analysis also have been developed with design work. ‘Demo SILO’ should evaluate an accurate 3D temperature distribution with minimal number of thermocouples and penetration holes to avoid disruption of internal flow and temperature distribution. For this reason, a ‘Best Estimate Thermal-Hydraulics evaluation system for SILO’ is under development and it will be essential for ensuring temperature prediction accuracy. Construction of a full-scale test apparatus to validate this technology will begin in 2024. In order to supply power to many heaters and monitor temperature gradient inside of this apparatus, it has modular design concept by dividing its whole body to axial 9 sub-bodies which looks like a donut containing a basket at center position.
        10.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        뇌 3차원 T1 관상면 검사 시 ENCASE를 적용했을 때 CS 계수의 증가 시 영상획득 시간 변화와 영상의 질의 변화에 따른 유용성에 관하여 알아보고자 한다. 연구 대상은 본원을 내원한 30명의 환자를 대상으로 하였고, 1.5T MRI 장치로 진행하였으며, 24채널 두경부 코일을 사용하였다. 획득한 영상의 상대적신호강도비(rSI)와 상대적대조도비(rC)를 구하였으 며, MIPAV로 뇌실질과 뇌실의 체적을 측정하여 One-way Anova를 사용하여 정량적 분석을 하였고, p<0.05일 때 통계 적으로 유의한 것으로 해석하였다. 또한, 5점 리커트 척도를 이용하여 영상의 질에 대하여 정성적 분석을 하였고, 측정자 내 신뢰도를 확인하기 위해 ICC가 0.75 이상 나오면 측정자간 신뢰성이 높은 것으로 간주하였다. rSI와 rC 모두 p<0.05로 통계적으로 유의미한 차이를 보였고, 급내 상관계수가 0.75이상(p<0.05)으로 통계적으로 매우 높은 신뢰도를 나타냈다. MIPAV를 이용한 체적측정에서는 뇌실질과 뇌실의 체적의 차이는 p=1.000으로 통계학적으로 유의미한 차이는 없었고, 사후분석결과 또한 유의미한 차이를 보이지 않았으며. 급내 상관계수가 0.75이상(p<0.05)으로 통계적으로 매우 높은 신뢰도를 나타냈다. 또한, 정성적 평가에서는 CS 계수가 증가함에 따라 유의미한 차이가 있는 것으로 나타났다(p<0.001). 따라 서 ENCASE 기법을 이용한 3차원 T1 TFE 관상면 검사 시 CS 계수를 증가시킨다면 뇌의 체적 변화 없이 3차원 T1 시상면 영상보다 짧은 150초로 기존의 뇌 3차원 시상면 T1 기본 검사시간 260초 보다 짧은 영상획득 시간으로 진단적 가치가 높은 영상을 제공할 수 있을 것으로 사료된다.
        4,000원
        20.
        2017.04 구독 인증기관·개인회원 무료
        As the hangover relieving drink market has been expanded, there have been efforts to produce traditional drinks that can be easily taken through reducing material costs after finding materials with high alcohol-degrading activity from agricultural products and manufacturing drinks in a way to produce sikhye. Studies were made to know quality, the ability to relieve hangover and preference of drinks for which seven kinds of agricultural products, including shiitake mushrooms, were added in the forms of fresh juice, extracts and powder. Farm products showed the highest acetaldehyde dehydrogenase (ALDH) when they were added in the form of powder before saccharification and shiitake mushrooms showed the highest enzyme activity when they were added in the form of powder. When added in the form of powder, people showed the lowest preference except when radish and hericium erinaceum were added. When bear puree was added to a mixture of powdered shiitake mushrooms, radish, bean sprouts and dadagi cucumber, enzyme activity got higher and people showed higher preference. An experiment of animal behaviors showed that the mixture had a high ability to relieve hangover in one or two hours after 10% or 40% alcohol was orally administered to mice due to long traveling distance of mice.
        1 2 3 4